• Title/Summary/Keyword: Wind tunnel design

Search Result 511, Processing Time 0.031 seconds

Simplified formulas for evaluation of across-wind dynamic responses of rectangular tall buildings

  • Liang, Shuguo;Li, Q.S.;Zou, Lianghao;Wu, J.R.
    • Wind and Structures
    • /
    • v.8 no.3
    • /
    • pp.197-212
    • /
    • 2005
  • Tall buildings under wind action usually oscillate simultaneously in the along-wind and across-wind directions as well as in torsional modes. While several procedures have been developed for predicting wind-induced loads and responses in along-wind direction, accurate analytical methods for estimating across-wind and torsional response have not been possible yet. Simplified empirical formulas for estimation of the across-wind dynamic responses of rectangular tall buildings are presented in this paper. Unlike established empirical formulas in codifications, the formulas proposed in this paper are developed based on simultaneous pressure measurements from a series of tall building models with various side and aspect ratios in a boundary layer wind tunnel. Comparisons of the across-wind responses determined by the proposed formulas and the results obtained from the wind tunnel tests as well as those estimated by two well-known wind loading codes are made to examine the applicability and accuracy of the proposed simplified formulas. It is shown through the comparisons that the proposed simplified formulas can be served as an alternative and useful tool for the design and analysis of wind effects on rectangular tall buildings.

Design of a Wind Tunnel for Plug Seedlings Production under Artificial Light and Aerodynamic Characteristics above Plug Stand (인공광하의 공정육묘용 풍동 설계 및 공정묘 개체군상의 공기역학적 특성)

  • 김용현;고재풍수
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.429-435
    • /
    • 1996
  • A wind tunnel consisting of two air flow conditioners with polycarbonate pipes, a plant growth room, a suction fan and fan controller, and fluorescent lamps, was designed to investigate the interactions between the growth of plug seedlings under artificial light and their Physical environments. Light transmissivities in the plant growth room based on the photosynthetic photon flux density and photosynthetically active radiation was appeared to be 96.3% and 96.8%, respectively. Measurement showed a uniformity in the vertical profiles of air current speed at the middle and rear regions of plug trays in wind tunnel. This result indicated that the development of a wind tunnel based on the design criteria of the American Society of Mechanical Engineers was adequate. Air current speed inside the plug stand was significantly decreased due to the resistance by the leaves of plug seedlings and boundary layer developed over and below the plug stand. Driving force to facilitate the diffusion of gas inside the plug stand might be regarded as extremely low. Aerodynamic characteristics above the plug stand under artificial light were investigated. As the air current speed increased, zero plane displacement decreased but roughness length and frictional velocity increased. Zero plane displacement linearly increased with the average height of plug seedlings. The wind tunnel developed in this study would be useful to investigate the effects of air current speed on the microclimate over and inside the plug stand and to collect basic data for a large-scale plug production under artificial light in a semi-closed ecosystem.

  • PDF

Wind-tunnel tests on high-rise buildings: wind modes and structural response

  • Sepe, Vincenzo;Vasta, Marcello
    • Wind and Structures
    • /
    • v.18 no.1
    • /
    • pp.37-56
    • /
    • 2014
  • The evaluation of pressure fields acting on slender structures under wind loads is currently performed in experimental aerodynamic tests. For wind-sensitive structures, in fact, the knowledge of global and local wind actions is crucial for design purpose. This paper considers a particular slender structure under wind excitation, representative of most common high-rise buildings, whose experimental wind field on in-scale model was measured in the CRIACIV boundary-layer wind tunnel (University of Florence) for several angles of attack of the wind. It is shown that an efficient reduced model to represent structural response can be obtained by coupling the classical structural modal projection with the so called blowing modes projection, obtained by decomposing the covariance or power spectral density (PSD) wind tensors. In particular, the elaboration of experimental data shows that the first few blowing modes can effectively represent the wind-field when eigenvectors of the PSD tensor are used, while a significantly larger number of blowing modes is required when the covariance wind tensor is used to decompose the wind field.

Experimental research on design wind loads of a large air-cooling structure

  • Yazhou, Xu;Qianqian, Ren;Guoliang, Bai;Hongxing, Li
    • Wind and Structures
    • /
    • v.28 no.4
    • /
    • pp.215-224
    • /
    • 2019
  • Because of the particularity and complexity of direct air-cooling structures (ACS), wind parameters given in the general load codes are not suitable for the wind-resistant design. In order to investigate the wind loads of ACS, two 1/150 scaled three-span models were designed and fabricated, corresponding to a rigid model and an aero-elastic model, and wind tunnel tests were then carried out. The model used for testing the wind pressure distribution of the ACS was defined as the rigid model in this paper, and the stiffness of which was higher than that of the aero-elastic model. By testing the rigid model, the wind pressure distribution of the ACS model was studied, the shape coefficients of "A" shaped frame and windbreak walls, and the gust factor of the windbreak walls were determined. Through testing the aero-elastic model, the wind-induced dynamic responses of the ACS model was studied, and the wind vibration coefficients of ACS were determined based on the experimental displacement responses. The factors including wind direction angle and rotation of fan were taken into account in this test. The results indicated that the influence of running fans could be ignored in the structural design of ACS, and the wind direction angle had a certain effect on the parameters. Moreover, the shielding effect of windbreak walls induced that wind loads of the "A" shaped frame were all suction. Subsequently, based on the design formula of wind loads in accordance with the Chinese load code, the corresponding parameters were presented as a reference for wind-resistant design and wind load calculation of air-cooling structures.

Evaluation of Wind Load and Drag Coefficient of Insect Net in a Pear Orchard using Wind Tunnel Test (풍동실험을 통한 배과원 방충망의 풍하중 및 항력계수 평가)

  • Song, Hosung;Yu, Seok-Cheol;Kim, Yu Yong;Lim, Seong-Yoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.1
    • /
    • pp.75-83
    • /
    • 2019
  • Fruit bagging is a traditional way to produce high-quality fruit and to prevent damage from insects and diseases. Growing pears by non-bagging is concerned about the damage from insect, it can be controlled by installing a insect net facility. Wind load should be considered to design the insect net facility because it has the risk of collapse due to the strong wind. So we carried out wind tunnel test for measurement of drag force, where the insect net with porosity about 65% is selected as an experimental subject. As a result of the test, drag force was measured to be 244.14 N when insect net area and wind speed are $1m^2$ and 22.7 m/s respectively. And, drag coefficients for the insect net were found to be about 0.55~0.57, which may be used as the preliminary data to design the insect net facilities at the orchard.

A study on the effect of gusty wind on smoke control performance in road tunnel (돌풍이 도로터널의 제연성능에 미치는 영향 연구)

  • Baek, Doo-San;Cho, Hyeon-Seok;Lee, Seung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.95-108
    • /
    • 2022
  • The increase in the use time of tunnel users due to the lengthening of the road tunnel may increase the evacuation time in case of fire, resulting in a large number of casualties. In order to reduce the casualties caused by fire, the "Road Tunnel Design Manual, Part 6 Tunnel" and "Road Tunnel Disaster Prevention Facility Installation and Management Guidelines" stipulate that ventilation facilities should be installed along with the extension of the tunnel. The ventilation system design factor considers the wind speed of the external natural wind to be at least 2.5 m/s, and it is applied upward according to the characteristics of the tunnel. As a result of analyzing the five-minute average wind speed data in the Daegwallyeong region for the past 6 years, it was analyzed that 15.8% of the windy days were winds of 10 m/s or more, and the maximum was 20 m/s. Therefore, in this study, when a fire occurs in a tunnel, the pattern of natural wind flowing into the tunnel and the backlayering distance of the tunnel fire smoke according to the maximum wind speed were analyzed. As a result, it was analyzed that a backflow of up to 490 m occurs when a gust of 20 m/s blows.

The numerical wind tunnel for industrial aerodynamics: Real or virtual in the new millennium?

  • Stathopoulos, T.
    • Wind and Structures
    • /
    • v.5 no.2_3_4
    • /
    • pp.193-208
    • /
    • 2002
  • Previous studies have shown that Computational Wind Engineering (CWE) is still in its infancy and has a long way to go to become truly useful to the design practitioner. The present work focuses on more recent studies to identify progress on outstanding issues and improvements in the numerical simulation of wind effects on buildings. The paper reviews wind loading and environmental effects; it finds that, in spite of some interesting and visually impressive results produced with CWE, the numerical wind tunnel is still virtual rather than real and many more parallel studies - numerical and experimental - will be required to increase the level of confidence in the computational results.

A Study on the Pollutant Dispersion over a Mountain Valley Region (I) : Wind Tunnel Experiments (산악 계곡지형에서의 오염확산에 관한 연구(I) :풍동실험)

  • Yoo Seong-Yeon;Shim Woo-Sup;Kim Seogcheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1050-1059
    • /
    • 2005
  • Heat and $SF_6$ gas dispersions over a complex terrain were investigated using wind tunnel. The wind speed, temperature and concentration profiles were measured for the 1/1000 scale complicated terrain model in an Eiffel type boundary layer wind tunnel with test section of 2.5m in height and 4.5m in width. The scale model was mounted on the top of a plate which can rotate with respect to the approaching wind. Dispersion processes from a continuous emission source driven by various wind direction were investigated, including plume climbing over the steep up-slope of the mountain and down-spreading toward the lower level of the valley. Extensive dispersion experiment data (wind speeds and concentration profiles) were provided for verification and validation of dispersion models. Under the identical flow and emission conditions, the independently measured profiles of the temperature and $SF_6$ concentration showed an excellent agreement which ensured the credibility of the results.

Distribution of Wind Pressure on Claddings of Apartment Buildings Affected by Neighboring Buildings (아파트 건축물 군(群)에 의한 건축물 외장재의 풍압분포)

  • Cho, Kang-Pyo;Hong, Sung-Il;Kim, Won-Sool
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.1 s.19
    • /
    • pp.91-99
    • /
    • 2006
  • This paper presents wind pressure distribution on high-rise apartment buildings through wind-tunnel tests. In order to investigate wind-induced interference efforts on building claddings an apartment complex, which was damaged on the claddings during typhoon attack, was exampled and constructed as a scaled model. A series of wind tunnel tests using pressure models were performed in a boundary layer wind tunnel. The test results with and without interfering buildings were compared and discussed. It is observed that the wind pressure on buildings 105 and 106 with surrounding buildings shows highly negative, while the pressure without surrounding buildings were positive. Therefore the wind-induced interference effects should be taken into account in the design of claddings through wind-tunnel tests.

  • PDF

Investigation on Severe Aerodynamic Load Condition about Pantograph (판토그래프 가혹공력하중에 대한 연구)

  • Hwang, Jae-Ho;Lee, Dong-Ho;Chung, Kyung-Ryul
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.361-366
    • /
    • 2001
  • The present study describes a practical estimation procedure about the pantograph under several severe aerodynamic load conditions. As the operating speed of the Korean Train Express(KTX) reaches 350km/h, structural safety at various conditions should be examined at the design stage. In the present study, a compact and reliable procedure is developed to get aerodynamic loads on each part of the pantograph regarding the typhoon condition, the train/tunnel interaction, the train/train interaction and the side wind condition. In the estimation procedure, 3-dimensional steady and unsteady CFD simulation around the high speed train facilitates assigning the external local flow condition around the pantograph. The procedure is verified using the results of the low speed wind tunnel test at JARI and applied to 7 flow conditions and 4 operation configurations.

  • PDF