• 제목/요약/키워드: Wind farm control

검색결과 104건 처리시간 0.029초

한우 및 젖소농장 발생 악취의 확산특성 연구 (A Study on Dispersion Characteristics of Odor from Hanwoo and Dairy Farms)

  • 김두환;하덕민;이재영;김희호;송준익
    • 한국축산시설환경학회지
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2015
  • This study was conducted to investigate the dispersion prediction of odor from Hanwoo and dairy farms. Gaussian Plume model used in considering of farm size, wind velocity, atmospheric stability and threshold odor unit to prediction of odor dispersion based on the survey on current state of odor emission and control from 9 site of Hanwoo and 9 site of dairy farms. Farm size, wind velocity and atmospheric stability were affected the distance of odor dispersion, showed longer distance in cases of large farm, low wind velocity and stable atmospheric condition. We will suggestion the adjusted distance of odor dispersion according to farm size was estimated to 50~100 m in Hanwoo farm and 50~150 m in dairy farm when apply the 3OU, 5 m/s wind velocity and stable atmospheric condition.

양돈장 발생 악취의 확산특성 연구 (A Study on Dispersion Characteristics of Odor from Swine Farms)

  • 김두환;하덕민;이인복;최동윤;송준익
    • 한국축산시설환경학회지
    • /
    • 제20권2호
    • /
    • pp.41-48
    • /
    • 2014
  • This study was conducted to investigate the dispersion prediction of odor from swine farms in Korea. Gaussian Plume model used in considering of farm size, wind velocity, atmospheric stability and threshold odor unit to prediction of odor dispersion based on the survey on current state of odor emission and control from 48 site of swine farms. Farm size, wind velocity and atmospheric stability were affected the distance of odor dispersion, showed longer distance in cases of large farm, low wind velocity and stable atmospheric condition. We will suggestion the adjusted distance of odor dispersion according to farm size was estimated to 180 m in small farm and 320 m in large farm when apply the 3 OU, 5 m/s wind velocity and stable atmospheric condition.

파워 조절 방법에 따른 풍력 터빈의 방사 소음 특성 (Characteristics of Noise Emission from Wind Turbine According to Methods of Power Regulation)

  • 정철웅;정완섭;신수현;전세종;최용문;정성수
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.864-871
    • /
    • 2006
  • In the development of electricity generating wind turbines for wind farm application, only two types have survived as the methods of power regulation; stall regulation and full span pitch control. The main purpose of this paper is to experimentally identify the characteristics of noise emission of wind turbines according to the power regulation types. The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbines (WT) utilizing the stall regulation and the pitch control for the power regulation, respectively. Apparent sound power level, wind speed dependence, third-octave band levels and tonality are evaluated for both of WTs. It is observed that equivalent continuous sound pressure levels (ECSPL) of the stall control type of WT continue to increase with increasing wind speed whereas those of the pitch control type of WT show less correlation with wind speed. These observed characteristics are believed to be due to the different airflow patterns around the blade between the stall regulation and the pitch control types of WT; the airflow on the suction side of blade in the stall types of WT are separated at the high wind speed. It is also found that the 1.5 MW WT using the stall control emits lower sound power than 660 kW one using the pitch control at wind speeds below 8m/s, whereas sound power of the former becomes higher than that of the latter in the wind speed over 8m/s. This wind-speed dependence of sound power leads to the very different noise omission characteristics of WTs depending on the seasons because the average wind speed in summer is lower than 8m/s whereas that in summer is higher. Based on these experimental observations, it is proposed that, in view of environmental noise regulation, the developer of wind farm should give enough considerations to the choice of power regulation of their WTG based on the weather conditions of potential wind farm locations.

Remote Monitoring with Hierarchical Network Architectures for Large-Scale Wind Power Farms

  • Ahmed, Mohamed A.;Song, Minho;Pan, Jae-Kyung;Kim, Young-Chon
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1319-1327
    • /
    • 2015
  • As wind power farm (WPF) installations continue to grow, monitoring and controlling large-scale WPFs presents new challenges. In this paper, a hierarchical network architecture is proposed in order to provide remote monitoring and control of large-scale WPFs. The network architecture consists of three levels, including the WPF comprised of wind turbines and meteorological towers, local control center (LCC) responsible for remote monitoring and control of wind turbines, and a central control center (CCC) that offers data collection and aggregation of many WPFs. Different scenarios are considered in order to evaluate the performance of the WPF communications network with its hierarchical architecture. The communications network within the WPF is regarded as the local area network (LAN) while the communication among the LCCs and the CCC happens through a wide area network (WAN). We develop a communications network model based on an OPNET modeler, and the network performance is evaluated with respect to the link bandwidth and the end-to-end delay measured for various applications. As a result, this work contributes to the design of communications networks for large-scale WPFs.

이중여자 유도발전기에 의한 가변속 풍력 발전시스템의 동특성 해석 (Dynamic Analysis of Variable Speed Wind Power Systems with Doubly-Fed Induction Generators)

  • 최장영;장석명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권6호
    • /
    • pp.325-336
    • /
    • 2006
  • This paper deals with the dynamic analysis of variable speed wind power systems with doubly-fed induction generators (DFIG). First, the mathematical modeling of wind farm which consists of turbine rotor, DFIG, rotor side and grid side converter and control systems is presented. In particular, the equation for dynamic modeling of the DFIG and the AC/DC/AC converter is expressed as dq reference frame. And then, on the basis of mathematical modeling for each component of wind farm, dynamic simulation algorithms for speed and pitch angle control of wind turbine and generated active and reactive power control of the DFIG and the AC/DC/AC converter are established. Finally, Using the MATLAB/SIMULINK, this paper presents dynamic simulation model for 6MW wind power generation systems with the DFIG considering distribution systems and performs the dynamic analysis of wind power systems in steady state. Moreover, this paper also presents the dynamic performance for the case when the voltage sag in grid source and phase fault in bus are occurred.

Development of Modular Control System Based on Closed-Loop Control for Wind Farms

  • Ji, Hyunho;Kim, Taehyoung;Lim, Jeongtaek;Ham, Kyung Sun
    • 인터넷정보학회논문지
    • /
    • 제22권6호
    • /
    • pp.17-24
    • /
    • 2021
  • The use of renewable energy sources for power generation has been steadily increasing. Power generation using renewable energy has the advantage of not generating carbon but has the disadvantage of high volatility depending on the weather. This volatility makes stable power supply difficult. Curtailment is occurring to address volatility. Various facilities are operated together to solve the loss caused by the curtailment. The existing SCADA must be modified for turbine control reflecting the conditions of various facilities. However, since it is difficult to modify SCADA, a modular control system is required. In this study, we propose Modular Control System Based on Closed-Loop Control for Wind Farms. Since the control logic can be changed without modifying SCADA, it is easy to respond to changes. The developed modular control system was evaluated as a lab test and confirmed to operate smoothly. Through future research, the experiment will be conducted by applying a modular control system to the actual wind farm.

풍력기반 하이브레드 풍력발전기의 원격 정전압 변동률 분석 장치에 관한 연구 (A Study of the Analysis System of Remote Control a Voltage Fluctuation of a Based Wind Turbine)

  • 장미혜;선민영;이종조;임재규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.456-459
    • /
    • 2009
  • we studied a data acquisition and control system of a wind turbine for measuring and controlling a voltage fluctuations of a wind turbine system. The wind turbine system is installed out control area. So, it is so important for supervising to wind turbine of a maintenance, wind speed, optical resources wind turbine output, wind speed, wind direction, over voltage of a generator. This system can be supplied a data of over voltage, under voltage, voltage fluctuations of a wind turbine for controlling an EMS : Energy Management System or a SCADA : Supervision Control and Data Acquisition at a constitute of a wind farm. The of voltage fluctuation system of a wind turbine is improving an electric power supply power quality of a distribution line and unspecified individuals of used wind turbine.

  • PDF

STATCOM과 조상설비를 이용한 풍력단지가 연계된 전력계통의 전압제어 (Voltage Control of Power System Connected to a Wind Farm by Using STATCOM and Reactive Power Compensators)

  • 서규석;박지호
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2737-2743
    • /
    • 2015
  • 풍력발전은 풍력단지가 전력계통과 접속되는 모선의 전압을 유지 또는 제어하기 위한 충분한 무효전력을 공급할 수 있어야 한다. 하지만 풍력단지와 계통 접속점(POI - Point of Interconnection) 모선을 연결하는 선로의 무효전력 손실 때문에 풍력터빈의 무효전력공급은 접속점의 전압을 제어하기에는 불충분하다. 이 문제는 접속점에 STATCOM(Static Synchronous Compensator)과 같은 부수적인 무효전력 보상장치를 설치하여 해결할 수 있다. 본 논문에서 제시하는 STATCOM과 Switched-Shunt, 탭변환 변압기와 같은 기존의 무효전력 보상장치의 협조제어를 사용하면 더욱 효과적으로 접속점 모선의 전압을 제어할 수 있다. 본 논문에서 제시한 방법을 이용하여 초기부하에 대하여 임의의 부하 변동률을 가지는 모의 시스템에 적용한 결과 접속점 모선의 전압강하는 60%이상 개선되었고 부하 모선의 전압은 정격전압의 95%이상을 유지하였다.

Hybrid Secondary Voltage Control combined with Large-Scale Wind Farms and Synchronous Generators

  • Kim, Jihun;Lee, Hwanik;Lee, Byongjun;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.399-405
    • /
    • 2014
  • For stable integration of large-scale wind farms, integration standards (Grid codes) have been proposed by the system operator. In particular, voltage control of large-scale wind farms is gradually becoming important because of the increasing size of individual wind farms. Among the various voltage control methods, Secondary Voltage Control (SVC) is a method that can control the reactive power reserve of a control area uniformly. This paper proposes hybrid SVC when a large-scale wind farm is integrated into the power grid. Using SVC, the burden of a wind turbine converter for generating reactive power can be reduced. To prove the effectiveness of the proposed strategy, a simulation study is carried out for the Jeju system. The proposed strategy can improve the voltage conditions and reactive power reserve with this hybrid SVC.

EPON을 기반으로 한 해상 풍력 단지 통신망 구조 (EPON Based Communication Network Architecture for Offshore Wind Power Farm)

  • 정진효;양원혁;김영천
    • 한국통신학회논문지
    • /
    • 제38B권2호
    • /
    • pp.130-139
    • /
    • 2013
  • 최근 풍력 발전 단지가 대형화 해상화됨에 따라 이를 모니터링하고 제어하기 위한 통신망의 중요성이 높아지고 있다. 본 논문에서는 해상 풍력 단지에서 사용하는 기존 Ethernet 기반의 통신망의 문제점인 지연시간, 데이터 처리 오버헤드 및 풍력 발전기간 데이터 전송의 공평성 문제를 해결하기 위하여 EPON(Ethernet Passive Optical Network) 기반의 통신망 구조를 제안하고 성능 평가를 수행한다. 제안한 구조는 OLT(Optical Line Terminal)를 중앙 제어 센터에 설치하고 해상의 풍력 발전기에 ONU(Optical Network Unit)를 설치하여 점 대 다점 통신망을 구성하는 토폴로지이다. EPON 기반 토폴로지는 수동소자를 사용함으로써 망 구성 비용이 저렴하고 관리가 용이하며 높은 신뢰성과 데이터 전송의 공평성을 보장할 수 있다. 제안한 통신망 구조의 성능을 평가하기 위하여 OPNET Modeler를 이용하여 IEC 61850 표준을 기반으로 한 풍력단지를 모델링한다. 시뮬레이션 결과는 기존 이더넷 기반의 통신망과 지연시간, 오버헤드 및 전송의 공평성 관점에서 비교 분석한다.