• Title/Summary/Keyword: Wind energy penetration

Search Result 69, Processing Time 0.021 seconds

Effect of water jetting parameters on the penetration behavior of jack-up spudcan in surficial sand condition

  • Han, Dong-Seop;Kim, Seung-Jun;Kim, Moo-Hyun
    • Ocean Systems Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-19
    • /
    • 2015
  • The water jetting system for a jack-up spudcan requires the suitable design considering the platform/spudcan particulars, environments, and soil conditions, either the surficial clay or surficial sand. The usage of water jetting depends critically on soil conditions. The water jetting is usually used for the smooth and fast extraction of the spudcan in the surficial clay condition. It is also required for inserting spudcan up to the required depth in the surficial sand condition, which is investigated in this paper. Especially, it should be very careful to use the water jetting during an installation of spudcan in the surficial sand condition, because there is a risk of overturning accident related to the punch-through. Therefore, in this study, the effect of water jetting flow rate and time on the change of soil properties and penetration resistance is analyzed to better understand their interactions and correlations when inserting the spudcan with water jetting in surficial sand condition. For the investigation, a wind turbine installation jack-up rig (WTIJ) is selected as the target platform and the multi layered soil (surficial sand overlaying clays) is considered as the soil condition. The environmental loading and soil-structure interaction (SSI) analysis are performed by using CHARM3D and ANSYS. This kind of investigation and simulation is needed to decide the proper water jetting flow rate and time of spudcan for the given design condition.

Effect of plate slope and water jetting on the penetration depth of a jack-up spud-can for surficial sands

  • Han, Dong-Seop;Kim, Seung-Jun;Kim, Moo-Hyun
    • Ocean Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.263-278
    • /
    • 2014
  • The spudcan requires the suitable design considering the soil, platform, and environmental conditions. Its shape needs to be designed to secure sufficient reaction of soil so that it can prevent overturning accidents. Its shape also has to minimize the installation and extraction time. Even in the same soil condition, the reaction of soil may be different depending on the shape of spud can, mainly the slope of top and bottom plates. Therefore, in this study, the relation between the slope of plates and the reaction of soil with and without water jetting is analyzed to better understand their interactions and correlations. For the investigation, a wind turbine installation jack-up rig (WTIJ) is selected as the target platform and the Gulf of Mexico is considered as the target site. A multi layered (sand overlying two clays) soil profile is applied as the assumed soil condition and the soil-structure interaction (SSI) analysis is performed by using ANSYS to analyze the effect of the slope change of the bottom plate and water jetting on the reaction of soil. This kind of investigation and simulation is needed to develop optimal and smart spudcan with water-jetting control in the future.

Flexible Voltage Support Control with Imbalance Mitigation Capability for Inverter-Based Distributed Generation Power Plants under Grid Faults

  • Wang, Yuewu;Yang, Ping;Xu, Zhirong
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1551-1564
    • /
    • 2016
  • The high penetration level of inverter-based distributed generation (DG) power plants is challenging the low-voltage ride-through requirements, especially under unbalanced voltage sags. Recently, a flexible injection of both positive- (PS) and negative-sequence (NS) reactive currents has been suggested for the next generation of grid codes. This can enhance the ancillary services for voltage support at the point of common coupling (PCC). In light of this, considering distant grid faults that occur in a mainly inductive grid, this paper proposes a complete voltage support control scheme for the interface inverters of medium or high-rated DG power plants. The first contribution is the development of a reactive current reference generator combining PS and NS, with a feature to increase the PS voltage and simultaneously decrease the NS voltage, to mitigate voltage imbalance. The second contribution is the design of a voltage support control loop with two flexible PCC voltage set points, which can ensure continuous operation within the limits required in grid codes. In addition, a current saturation strategy is also considered for deep voltage sags to avoid overcurrent protection. Finally, simulation and experimental results are presented to validate the effectiveness of the proposed control scheme.

A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types (케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구)

  • Choi, Taehwoan;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.57-62
    • /
    • 2007
  • At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.

A Study on Simplified Robust Optimal Operation of Microgrids Considering the Uncertainty of Renewable Generation and Loads (신재생에너지와 부하의 불확실성을 고려한 마이크로그리드의 단순화된 강인최적운영 기법에 관한 연구)

  • Lee, Byung Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.513-521
    • /
    • 2017
  • Robust optimal operation of a microgrid is required since the increase of the penetration level of renewable generators in the microgrid raises uncertainty due to their intermittent power output. In this paper, an application of probabilistic optimization method to economical operation of a microgrid is studied. To simplify the treatment of the uncertainties of renewable generations and load, the new 'band of virtual equivalent load variation' is introduced considering their uncertainties. A simplified robust optimization methodology to generate the scenarios within the band of virtual equivalent load variation and to obtain the optimal solution for the worst scenario is presented based on Monte Carlo method. The microgrid to be studied here is composed of distributed generation system(DGs), battery systems and loads. The distributed generation systems include combined heat and power(CHP) and small generators such as diesel generators and the renewable energy generators such as photovoltaic(PV) systems and wind power systems. The modeling of the objective function for considering interruption cost by the penalty function is presented. Through the case study for a microgrid with uncertainties, the validity of proposed robust optimization methodology is evaluated.

A Study on Decision Plan of Hosting Capacity for Distribution Feeder (배전선로 연계용량 선정방안에 관한 연구)

  • Kim, Seong-Man;Oh, Joon-Seok;Kim, Ok-Hee;Lim, Hyeon-Ok;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.653-660
    • /
    • 2021
  • Renewable energy resources are rapidly becoming an integral part of electricity generation portfolios around the world due to declining costs, government subsidies, and corporate sustainability goal. Interacting wind, solar, and load forecast errors can create significant unpredictable impacts on the distribution system, feeder congestion, voltage standard and reactive power stability margins. These impacts will be increasing with the increasing penetration levels of variable renewable generation in the power systems. There is a limit to the maximum amount of renewable energy sources that can be connected in a distribution feeder by the connection rule of transmission & distribution facility in Korea. This study represents the decision plans of hosting capacity for distribution feeders without the need for significant upgrades to the existing transmission infrastructure. Especially, the paper suggests and discusses the hosting capacity standard of feeder cables and minimum load calculation of distribution feeders.

Impact of aggressive exposure conditions on sustainable durability, strength development and chloride diffusivity of high performance concrete

  • Al-Bahar, Suad;Husain, A.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.1
    • /
    • pp.35-48
    • /
    • 2015
  • The main objective of this study is to evaluate the long-term performance of various concrete composites in natural marine environment prevailing in the Gulf region. Durability assessment studies of such nature are usually carried out under aggressive environments that constitute seawater, chloride and sulfate laden soils and wind, and groundwater conditions. These studies are very vital for sustainable development of marine and off shore reinforced concrete structures of industrial design such as petroleum installations. First round of testing and evaluation, which is presented in this paper, were performed by standard tests under laboratory conditions. Laboratory results presented in this paper will be corroborated with test outcome of ongoing three years field exposure conditions. The field study will include different parameters of investigation for high performance concrete including corrosion inhibitors, type of reinforcement, natural and industrial pozzolanic additives, water to cement ratio, water type, cover thickness, curing conditions, and concrete coatings. Like the laboratory specimens, samples in the field will be monitored for corrosion induced deterioration signs and for any signs of failureover initial period ofthree years. In this paper, laboratory results pertaining to microsilica (SF), ground granulated blast furnace slag (GGBS), epoxy coated rebars and calcium nitrite corrosion inhibitor are very conclusive. Results affirmed that the supplementary cementing materials such as GGBS and SF significantly impacted and enhanced concrete resistivity to chloride ions penetration and hence decrease the corrosion activities on steel bars protected by such concretes. As for epoxy coated rebars applications under high chloride laden conditions, results showed great concern to integrity of the epoxy coating layer on the bar and its stability. On the other hand corrosion inhibiting admixtures such as calcium nitrite proved to be more effective when used in combination with the pozzolanic additives such as GGBS and microsilica.

Demand Shifting or Ancillary Service?: Optimal Allocation of Storage Resource to Maximize the Efficiency of Power Supply (Demand Shifting or Ancillary Service?: 효율적 재생발전 수용을 위한 에너지저장장치 최적 자원 분배 연구)

  • Wooyoung Jeon
    • Environmental and Resource Economics Review
    • /
    • v.33 no.2
    • /
    • pp.113-133
    • /
    • 2024
  • Variable renewable energy (VRE) such as solar and wind power is the main sources of achieving carbon net zero, but it undermines the stability of power supply due to high variability and uncertainty. Energy storage system (ESS) can not only reduce the curtailment of VRE by load shifting but also contribute to stable power system operation by providing ancillary services. This study analyzes how the allocation of ESS resources between load shifting and ancillary service can contribute to maximizing the efficiency of power supply in a situation where the problems caused by VRE are becoming more and more serious. A stochastic power system optimization model that can realistically simulate the variability and uncertainty of VRE was applied. The analysis time point was set to 2023 and 2036, and the optimal resource allocation strategy and benefits of ESS by varying VRE penetration levels were analyzed. The analysis results can be largely summarized into the following three. First, ESS provides excellent functions for both load shifting and ancillary service, and it was confirmed that the higher the reserve price, the more limited the load shifting and focused on providing reserve. Second, the curtailment of VRE can be a effective substitute for the required reserve, and the higher the reserve price level, the higher the curtailment of VRE and the lower the required amount of reserve. Third, if a reasonable reserve offer price reflecting the opportunity cost is applied, ESS can secure economic feasibility in the near future, and the higher the proportion of VRE, the greater the economic feasibility of ESS. This study suggests that cost-effective low-carbon transition in the power system is possible when the price signal is correctly designed so that power supply resources can be efficiently utilized.

Shape Optimization of a Hole for Water Jetting in a Spudcan for a Jack-up Rig (잭업리그 스퍼드캔의 물 분사용 홀 형상 최적화)

  • Seong, Jeong Hyeon;Han, Dong Seop;Park, Young Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.4
    • /
    • pp.337-342
    • /
    • 2016
  • A spudcan is mounted on the lower leg of the jack-up rig, a device for preventing a rollover of a structure and to support the structure in a stable sea floor. At the time of inserting the surface of the spud can to penetrate when the sand layer is stable and smoothly pulled to the clay layer, and at that time of recovery when uploading the spud can is equipped with a water injection device. In this study, it is significant to optimize the shape of pipelines holes for water injection device and it was set in two kinds of shape, the oval and round. Interpretation of the subject into the site of Gulf of Mexico offshore Wind Turbine Installation Vessels (WTIV) was chosen as a target platform. Using the ANSYS Workbench commercial programs, optimal design was conducted. The results of this study can be applied to the hole-shaped design of various marine structures.