• 제목/요약/키워드: Wind Speed Data

검색결과 1,213건 처리시간 0.028초

대기안정도(大氣安定度)와 지형조건(地形條件)에 따른 풍향변동폭(風向變動幅)의 특성(特性) (Influence of Atmospheric Stability and Topography on the Wind Direction Fluctuations)

  • 김용국;이종범
    • 한국대기환경학회지
    • /
    • 제8권2호
    • /
    • pp.138-145
    • /
    • 1992
  • Dependence of the standard deviation of wind direction fluctuations, ${\sigma}_{\theta}$, on atmospheric stability, averaging time and topography were analysed with the data measured at three sites, Youngjongdo beach of the Yellow Sea, Chuncheon basin and Doam-Dam valley. The results show that the mean value of ${\sigma}_{\theta}$ is large in complex terrain, the Doam-Dam site. It is notable that the large value of ${\sigma}_{\theta}$ at night is associated with the low wind speed and the strong stable condition. In order to study the long-period fluctuations of the wind direction, ${\sigma}_{\theta}$ for longer than 10 minutes averaging time was further analysed using the data obtained at the Chuncheon basin. At the averaging time shorter than 60 minutes, larger ${\sigma}_{\theta}$ is associated with longer averaging time in the strong stable condition. However, ${\sigma}_{\theta}$ was not affected significantly by wind speed and averaging time in neutral conditions. The results of the spectrum analysis for the time series data of wind direction showed that low-frequency fluctuations ranging from 10 to 60 minutes were dominated at the Chuncheon basin in strong stable condition.

  • PDF

500kW급 풍력터빈의 성능평가에 관한 수치해석적 연구 (Estimate of the power characteristics of the 500kw wind turbine based on 3D numerical solutions)

  • 김범석;이진석;김정환;이도형;이영호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.140-145
    • /
    • 2002
  • The purpose of this 3-D numerical simulation is to calculate and examine a 500 kW Horizontal Axis Wind Turbine (HAWT) power performance and compare to calculation data(BEM method) from Delft University. The experimental approach, which has been the main method of investigation, appears to be reaching its limits, the cost increasing relate with the size of wind turbines. Hence, the use of Computational Fluid Dynamics (CFD) techniques and Navier-Stokes Solvers are considered a very serious contender. We has used the CFD software package CFX-TASC flow as a modeling tool to predict the power performance of a wind turbine on the basis of its geometry and operating data. The wind turbine with 40m diameters rotor, it was scaled to compare with the calculation data from delft university. The HAWT, which has eight-rpm variations are investigated respectively. The pitch angle is $+0.5^{\circ}$ and wind speed is fixed at 5m/s. The tip speed ratio (TSR) of the HAWT ranging from 2.89 to 9.63.

  • PDF

UHF 레이더 자료의 품질 평가 (Evaluation of UHF Radar Data)

  • 이경훈;권병혁;윤홍주
    • 한국전자통신학회논문지
    • /
    • 제16권3호
    • /
    • pp.423-428
    • /
    • 2021
  • 윈드프로파일러와 라디오존데 관측을 함께 하고 있는 북강릉과 창원의 윈드프로파일러에 대한 성능을 평가하였다. 2019년 12월부터 2020년 11월까지 1년간 고도별·월별 풍속 자료 수집률을 조사하고, 라디오존데의 풍속과 비교하였다. 두 관측 지점의 정상 자료 수집률은 최저 관측 고도에서 낮다가 증가하였고, 2 km 이상부터 다시 감소하였다. 여름철(6, 7, 8월)의 수집률이 높았고, 겨울철(12, 1, 2월)의 수집률이 낮았다. 라디오존데와 비교한 결과는 고층 모드에서 0.9, 저층 모드에서 0.8의 높은 상관관계를 보였다.

The effect of small embankments on wind speeds

  • Quinn, A.D.;Robertson, A.P.;Hoxey, R.P.;Short, J.L.;Burgess, L.R.;Smith, B.W.
    • Wind and Structures
    • /
    • 제1권4호
    • /
    • pp.303-315
    • /
    • 1998
  • Full-scale measurements have been made to determine the increase in wind speed over two exposed embankments, one of $23^{\circ}$ slope and 4.7 m in height, the other of $24^{\circ}$ slope and 7.3 m in height. Measurements were made at heights of 5, 10 and 15 m above the upper edge of each embankment and at the same heights approximately 100 m upwind in the lower-level approach fetch. Despite the modest sizes of the embankments, the maximum recorded increase in mean wind speed was 28% and the minimum was 13%; these increase relate to increases in wind loads on structures erected at the top of the embankments of 64% and 28% respectively. The associated increases in gust speeds are estimated at 33% and 18%, which imply increases in gust loading of 77% and 39% respectively. These experimental results are compared with predictions obtained from a computational fluid dynamics (CFD) analysis, using three high Reynolds number eddy-viscosity models and estimates from the UK wind loading code, BS 6399: Part 2. The CFD results are generally in agreement with the experimental data, although near-ground effects on the embankment crest are poorly reproduced.

제주 북동부 지역의 지형과 대기변수에 따른 AEP계산의 정확성에 대한 연구 (An Accuracy Estimation of AEP Based on Geographic Characteristics and Atmospheric Variations in Northern East Region of Jeju Island)

  • 고정우;이병걸
    • 한국측량학회지
    • /
    • 제30권3호
    • /
    • pp.295-303
    • /
    • 2012
  • 풍력발전 단지의 수익성 평가를 위해 연간 에너지 생산량(AEP ; Annual Energy Production)의 계산이 중요하다. AEP를 계산하기 위해서는 바람의 확률밀도함수(PDF ; Probability Density Function)와 풍력발전기의 발전곡선(PC; Power Curve)이 필요하며, AEP 예측의 정확성을 향상시키기 위해서는 허브 높이에서의 PDF예측과 그 높이의 공기밀도에 따른 풍력발전기 PC의 결정이 중요하다. 본 연구에서는 제주도 한동, 평대의 실관측 풍황탑(met mast) 자료를 이용하였으며 풍속의 PDF를 Weibull 분포 함수로 가정 하였고 Weibull 함수의 파라미터의 값이 높이에 따라 변화하는 양상을 확인하였다. Weibul 함수의 계산은 모멘트법과 LN-least법을 사용하였으며, 모멘트법과 LN-least법에 의한 형상계수의 경우 높이의 증가에 따라 변화를 보이지 않았고 평균값에서 ${\pm}0.1$의 변화 패턴을 보였다. 척도계수의 경우 높이가 증가함에 따라 선형적으로 증가하였으며 지형별 분류에 따른 높이별 척도계수의 기울기는 확연한 차이를 보이고 있었다. 60m 높이에서 관측된 바람의 상대도수와 관측 값의 높이 보정에 의한 공기밀도와 일반식에 의한 공기밀도를 각각 계산하여 그 결과에 대응하는PC를 선택하여 AEP차이를 계산하였다.

6kW 독립형 풍력발전기의 진동 모니터링 및 분석 (Vibration Monitoring and Analysis of a 6kW Wind Stand Alone Turbine Generator)

  • 김석현;남윤수;유능수;이정완;박무열;박해균;김태형
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.81-86
    • /
    • 2005
  • A vibration monitoring system for a small class of wind turbine (W/T) is established and operated. The monitoring system consists of monolithic integrated chip accelerometer for vibration monitoring, anemometers for wind data acquisition and auxiliary sensors for atmospheric data. Using the monitoring system, vibration response of a 6kW W/T generator is investigated. Acceleration data of the W/T tower under various operation condition is acquired in real time using LabVIEW and is remotely transferred from the test site to the laboratory in school by internet. Vibration state of the tower structure is diagnosed within the operating speed range. Resonance frequency range of the test model is investigated with the wind speed data of the test site.

  • PDF

단지교정을 위한 빈평균방법과 최소자승법의 비교 (Comparison of Bin Averaging Method and Least Square Method for Site Calibration)

  • 유능수;남윤수;이정완;이명재
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.157-164
    • /
    • 2005
  • Two methods, the bin averaging method and least square method, are often used in calibrating wind turbine test sites. The objective of this work was to determine a better method to predict the wind speed at wind turbine installing point. The calibration was done at the test site on a complex terrain located in Daegwallyeong, Korea. It was performed for two different cases based on the IEC 61400-12 power performance measurement standard. The wind speeds averaged for 10 minutes ranged between 4 m/s and 16 m/s. The wind-direction bins of each meteorological mast were 10 degrees apart, and only the bins having data measured for more than 24 hours were employed for the test site calibration. For both cases, the two methods were found to yield almost same results which estimated real wind speed very closely.

  • PDF

Wind Tunnel Testing Productivity at KARI LSWT

  • Chung, Jindeog;Cho, Taehwan;Sung, Bongzoo;Lee, Jangyeon
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제2권1호
    • /
    • pp.103-109
    • /
    • 2001
  • Productivity enhancement program of wind tunnel testing has begun at Korea Aerospace Research Institute Low Speed Wind Tunnel (KARI LSWT). A previous test record of a canard airplane model was adopted to examine the current status of wind tunnel testing efficiency. The time consumed to perform testing activities from the model preparation to data collection was broken down and the results were compared with those of the recent Boeing low speed test result. The efforts to improve the wind tunnel productivity consisted of the installation of mini crane underneath of test section, fabricating lift device for image fairings, model configuration changing rigs and the modifications of external balance system. Time reductions for changing strut interface platform and installation of image fairings. These effects showed more than 70% improvement over the previous test time. Integration of the new and modified systems will improve productivity of wind tunnel testing in KARI LSWT.

  • PDF

U57 풍력발전기 전력품질 실증연구 (Study of Power Quality Measurement U57 Windturbine)

  • 이병철;박희철;황진수;류지윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.310-314
    • /
    • 2008
  • The exploitation of the wind energy resource is a rapidly growing area world-wide. The number of installed units is continuously increasing, and it is important to respect and to deal with the impact of wind turbine. This paper addresses the power quality characteristics of U57 Wind Turbine. 750kW gearless type wind turbine for low wind speed, named U57, is developed by UNISON. The power quality measurement system consists of measuring WTG output current, line-to line voltage and wind speed signal. With using measured data, power quality measurement is evaluated about maximum power, reactive power, voltage fluctuation, harmonics according to IEC 61400-21.

  • PDF

생물생산시설의 구조설계에 관한 연구 I. 설계하중 산정을 위한 기상자료 빈도분석 (Studies on the Structural Design of Biological Production Facility I. Frequency Analysis of Weather Data for Design Load Estimation)

  • 김문기;손정익;남상운;이동근;이석재
    • 생물환경조절학회지
    • /
    • 제1권1호
    • /
    • pp.1-13
    • /
    • 1992
  • 본 연구는 생물생산시설의 안전구조설계기준 마련을 위한 기초자료를 제공하기 위하여, 우리나라의 60개 지역에 대한 기상자료를 사용하여 설계하중 산정에 필요한 재현기간별 설계풍속 및 설계 적설심을 구하고 등풍속선도 및 등적설심선도를 작성하였으며, 얻어진 결과를 요약하면 다음과 같다. 1. 년최고치 계열의 최대풍속 및 최대적설심 자료에 대한 Type-I 극치분포의 적정 확률분포형 검정을 위해 Chi-Square검정을 실시한 결과 대부분 지역에서 적합성이 인정되었다. 2. 적정 확률분포형으로 설정된 Type-I 극치분포에 의하여 재현기간별 표본 수에 따른 빈도계수를 구하고, 각 지역의 설계풍속 및 설계적설심을 구하였으며 결과는 Table 5와 Table 6, 그리고 Fig.3 및 Fig.4와 같다. 3. 최대풍속의 최빈풍향 분석결과 최대풍속의 약 46.4 %가 일정한 방향인 것으로 나타났으며, 지형이나 환경상의 문제가 없을 경우 최빈풍향을 고려해 주는 시설배치로 구조적 안전성을 향상시킬 수 있을 것으로 생각된다. 4. 우리나라의 풍속 및 적설심을 고려해 볼 때 울릉도 및 영동지방은 시설재배지역으로 매우 불리하며, 충남과 전북 서해안 지역은 적설에, 서남해안 지역은 바람에 강한 구조로 설계하는 것이 바람직하다는 것을 확인할 수 있었다.

  • PDF