• Title/Summary/Keyword: Wind Generation Systems

Search Result 264, Processing Time 0.026 seconds

Design of Wind Turbines for Reducing Interference to Radar Signals (레이더 신호 간섭의 최소화를 위한 풍력 발전기 설계)

  • Park, Kang-Kook;Chin, Hui-Cheol;Kim, Kyung-Tae;Kim, Hyo-Tae;Kim, Jin-Bong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.4
    • /
    • pp.533-540
    • /
    • 2012
  • The use of wind energy is gaining importance because of its many advantages. Nations worldwide are promoting the installation of wind farms to produce electricity in an attempt to tackle climate change and increasing oil costs. But, wind turbines can generate undesired signals which disturb the performance of military radar systems. Because the current generation of on and off-shore three bladed wind turbines have radar signatures consistent with their very large physical size. So this study considers the options available for the reduction of wind turbine radar signature and presents solutions for each of the main external turbine components. The radar signature reduction approaches are based on existing technologies developed for aerospaces stealth applications. However, the realization of these for the purposes of reduction wind turbine radar signatures is a novel development, particularly in the solutions proposed. This paper is presented techniques which reduce radar signatures of wind turbine. We know that radar signatures of wind turbine reduce by using these techniques.

Analyzing Site Characteristics and Suitability for Wind Farm Facilities in Forest Lands (산지 내 풍력발전단지 입지 특성 및 적합성 분석)

  • Kwon, Soon-Duk;Joo, Woo-Yeong;Kim, Won-Kyung;Kim, Jong-Ho;Kim, Eun-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.4
    • /
    • pp.86-100
    • /
    • 2014
  • The purposes of this study are to provide a guideline for the suitability of wind farm facilities in forest lands and to suggest improvement plans of policies and systems to minimize the damage of forest lands. First, we implemented a literature review and field surveys to examine and select factors for the suitability of wind farm facilities in forest lands. Spatial database for selected location factors of wind farm facilities in forest lands was constructed to develop the suitability model for locating wind farm facilities focusing on Gangwon-do. Data used in this study include wind power resource, legal mountainous preserved area, forest roads, developed areas, forest class, and other spatial data. In order to find specific-sized potential areas for a certain number of wind farm turbines, we used block statistics and focal statistics methods. As a result, the areas for potential wind farm locations were 1,261ha from a block statistics method and 1,411ha from a focal statistics method. Based on the outputs of this research, it is required to make an urgent solution for the prevention of forest disaster and to prepare reduction measures for the destruction of ridge landscape.

Compensation of Voltage Variation Using Active Power-Dependent Reactive Power Control with Multiple VRE Systems Connected in a Distribution Line (배전 선로에 연계된 다수대의 변동성 재생에너지 발전 시스템의 출력 유효전력 변동에 따른 무효전력 제어를 이용한 전압 변동 보상)

  • Lee, Sang-Hoon;Kim, Soo-Bin;Song, Seung-Ho
    • Journal of Wind Energy
    • /
    • v.9 no.4
    • /
    • pp.47-56
    • /
    • 2018
  • This paper introduces an active power dependent standard characteristic curve, Q(P) to compensate for voltage variations due to the output of distributed generation. This paper presents an efficient control method of grid-connected inverters by comparing and analyzing voltage variation magnitude and line loss according to the compensation method. Voltage variations are caused not only by active power, but also by the change of reactive power flowing in the line. In particular, the system is in a relatively remote place in a coastal area compared with existing power plants, so it is relatively weak and may not be suitable for voltage control. So, since it is very important to keep the voltage below the normal voltage limit within the specified inverter capacity and to minimize line loss due to the reactive power. we describe the active power dependent standard characteristic curve, Q(P) method and verify the magnitude of voltage variation by simulation. Finally, the characteristics of each control method and line loss are compared and analyzed.

The Investigation of Problems for Next Generation Energy System during Existing Urban Plan Stage (기존 도시계획 단계에서 차세대에너지시스템 적용시 문제점 검토)

  • Park, Jin-Young;Kim, Sam-Uel;Park, Yool;Lee, Sang-Jin;Lee, Jurng-Jae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.190-195
    • /
    • 2009
  • Since the industrial revolution, the global environmental problems such as greenhouse gas accumulation and the average temperature increase have caused people's attention. 'Low Carbon, Green Growth' was presented to cope with these global concerns, as one of main policies of 2008 in Korea. The paradigm of a green urban development is started to concern the whole city's energy problems owing to realize 'Low Carbon, Green Growth' in the urban side. The government established a nation's basic energy plan for 20 years, and some local cities made efforts to develop new renewable energy such as the solar, wind and water energy which are suitable to each city's character. As a part of these efforts, the concept of U-Eco city is newly appeared to reflect upon ubiquitous technique, urban ecology and the next generation energy system. However, urban plan is difficult to adopt this next generation energy system with existing laws, regulations and technical systems. The new executive and systematic system is needed to realize the U-Eco city U-Eco for the management of an efficient city. In this study, the authors investigate the concept of the next generation energy system and U-Eco city to realize the energy-efficient city plan and analyze problems to occur during the application of them in an existing city plan. Then, the authors show the remedies to deal with occurred problems.

  • PDF

Measurement of Dust Concentration in a Mechanically Ventilated Broiler House and Analysis of Dust Generation from Ground Beds (강제환기식 계사의 공기 중 분진 농도 측정 및 바닥재로부터의 분진 발생량 분석)

  • Kwon, Kyeong Seok;Jo, Ye Seul;Lee, In Bok;Ha, Tae Hwan;Hong, Se Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.31-43
    • /
    • 2014
  • Confined and mechanically ventilated broiler house has been recently come into wide use to increase productivity and control rearing conditions. However, high dust concentration inside facility can threaten respiratory welfare of farmers and broilers. In Korea, there is no regulation in terms of air quality control inside agricultural facilities and sufficient data is not available. To cope with these, periodic monitoring of inhalable and respirable dust concentration were conducted according to season, broiler's activity and specific events such as shipment work for broilers in mechanically ventilated broiler house. Chamber experiment was also designed to analyze mechanism of dust generation from ground beds according to water contents and surrounding wind environment. Results showed that significant increase of inhalable (p=0.002) and respirable (p=0.03) dust were observed when activity of broilers was high according to entrance of the workers. Even shipment work for matured broilers, high level of dust were observed; inhalable dust was exceeded the threshold limit over maximum 303 % and respirable dust was over maximum 1,550 %, implying that acute respiratory symptoms could be manifested for the workers. From the chamber experiment, critical water contents for interrupting of dust generation were measured; about 45 % for inhalable dust and about 50 % for respirable dust. These results can be a trigger for designing plan of dust control however it still needs consideration of various environmental conditions, hygiene problems, etc.

Development of Operation Control and AC/DC Conversion Integrated Device for DC Power Application of Small Wind Power Generation System (소형 풍력발전시스템의 직류전원 적용을 위한 운전제어 및 AC/DC변환 통합장치 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.179-184
    • /
    • 2019
  • In many countries, such as developing countries where electricity is scarce, small wind turbines in the form of Off Grid are an effective solution to solve power supply problems. In some countries, the expansion of power systems and the decline of electricity-intensive areas have led to the use of small wind power in urban road lighting, mobile communications base stations, aquaculture and seawater desalination. With this change, the size of the small wind power industry is expected to have greater potential than large-scale wind power. In the case of small wind power generators, the generator is controlled at a variable speed, and the voltage and current generated by the generator have many harmonic components. To solve this problem, the AC to DC converter to be studied in this paper is a three-phase step-up type converter with a single switch. The inductor current is controlled in discontinuous mode, and has a characteristic of having a unit power factor by eliminating the harmonic of the input current. The proposed converter is composed of LCL filter and three phase rectification boost converter at the input stage and a single phase full bridge for grid connection. It is a control system with energy storage system(ESS) that the system stabilization can be pursued against the electric power.

Global Environmental Impacts Assessment of Power Generation Technologies with LCA Method (LCA를 통한 국내 발전기술의 글로벌 환경성 평가)

  • Chung Whan-Sam;Kim Seong-Ho;Kim Tae-Woon
    • Journal of Energy Engineering
    • /
    • v.14 no.2 s.42
    • /
    • pp.140-146
    • /
    • 2005
  • In this study, a quantitative environmental impacts assessment was performed for various power technologies with a lift cycle assessment (LCA) method. The LCA is regarded as a useful tool far analyzing diverse environmental impacts at a local, regional, and global aspect. The investigated power plants such as nuclear, coal, and LNC power systems were selected because they took share over $90\%$ of domestic elec-tricity supply in Korea. Furthermore, a wind power technology was included as a representative energy source out of Korean renewable energy systems. According to the three geological aspects, environmental impacts had been categorized into eight types. For these impact categories, characterization had been carried out for comparing environmental burdens of power systems under consideration. Then, normalization had been done in order to gain a better understanding of the relative size among impact categories.

Evaluation Method for Protection Coordination of PV Systems Interconnected with Primary Feeders (태양광전원이 연계된 고압배전선로의 보호협조 평가 방안에 관한 연구)

  • Kim, Byungki;Kim, Sohee;Ryu, Kyungsang;Rho, Daeseok
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.4
    • /
    • pp.29-37
    • /
    • 2011
  • Dispersed generation (DG) such as wind power (WP) and Photovoltaic systems (PV) that has been promoted at the national level recently is mainly being introduced into distribution systems adjacent to consumers because it is generation on a small scale when compared to current generation. Due to its characteristics, DG can be operated by interconnection with distribution systems to present security of more stable power and efficient use of power facilities and resources. Problems on protection coordination of distribution systems by reverse flow of DG can roughly be divided into three possibilities: excess in rated breaking capacity (12.5KA) of protective devices by a fault in DG current supply, failure to operate protective devices by an apparent effect that can occur by reduction in impedance parallel circuit fault current due to interconnection of DG, and malfunction of protective devices by interconnection transformer connection type. The purpose of this study is to analyze problems in protection coordination that can occur when DG is operated by interconnection with distribution systems by conducting modeling and simulations by using theoretical symmetrical components and MATLAB/SIMULINK to present methods to improve such problems.

Wind load analysis of Structure for Folding Solar Power System (접이식 태양광 발전 구조물의 풍하중해석)

  • Son, Chang-Woo;Kim, Tae-Kyun;Seo, Tae-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.1-7
    • /
    • 2018
  • A folding solar power system is a stand-alone system and is a structure with solar panels attached. It consists of supporting parts and folding parts for ease of movement. While the efficiency of solar panels is also important to produce electricity by maximizing the power efficiency of solar panels, the most important thing is structure stability. The folding solar power structure intended to be developed in this study is a collapsible structure that is easy to move and install into systems that can produce electricity from grid to independent. Since these structures are installed outdoors, wind loads, snow cover, etc. In this paper, the wind loads most affected by the folding solar power generation structure were obtained using the MeshFree Finite Element Method. MeshFree is a program that makes it easier for users to interpret by simplifying the mesh tasks required by an existing analysis. The analysis showed that the greater the angle of inclination of the wind to the ground, the greater the wind load. In addition, reliability was ensured by wind load testing.

Long term monitoring of a cable stayed bridge using DuraMote

  • Torbol, Marco;Kim, Sehwan;Shinozuka, Masanobu
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.453-476
    • /
    • 2013
  • DuraMote is a remote sensing system developed for the "NIST TIP project: next generation SCADA for prevention and mitigation of water system infrastructure disaster". It is designed for supervisory control and data acquisition (SCADA) of ruptures in water pipes. Micro-electro mechanical (MEMS) accelerometers, which record the vibration of the pipe wall, are used detect the ruptures. However, the performance of Duramote cannot be verified directly on a water distribution system because it lacks an acceptable recordable level of ambient vibration. Instead, a long-span cable-stayed bridge is an ideal test-bed to validate the accuracy, the reliability, and the robustness of DuraMote because the bridge has an acceptable level of ambient vibration. The acceleration data recorded on the bridge were used to identify the modal properties of the structure and to verify the performance of DuraMote. During the test period, the bridge was subjected to heavy rain, wind, and a typhoon but the system demonstrates its robustness and durability.