• Title/Summary/Keyword: Wilcoxon test

Search Result 942, Processing Time 0.021 seconds

Comparison of Serum Cytokines($IL-1{\beta}$, IL-6, and $TNF-{\alpha}$) between Terminal Cancer Patients Treated with Vitamin C and Them without Vitamin C Therapy (Anorexia-Cachexia Syndrome을 가진 말기 암 환자에서 비타민 C 사용여부에 따른 사이토카인 변화 비교)

  • Yeom, Chang-Hwan;Suh, Sang-Youn;Cho, Kyung-Hee;Sun, Young-Gyu;Park, Yong-Gyu;Lee, Hye-Ree
    • Journal of Hospice and Palliative Care
    • /
    • v.6 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Purpose : Anorexia-cachexia syndrome is one of the most common symptoms and main cause of death in terminal cancer patients. This symptom is due to the enlarged cancer mass as well as tumor released cytokines. Some doctors have suggested that vitamin C was preferentially toxic to tumor cells in vitro and in vivo, and improved clinical symptoms in terminal cancer patients. Therefore, we measured cytokines in serum of terminal cancer patients to determine whether vitamin C treatment improved the anorexia-cachexia syndrome. Methods : We investigated that 49 terminal cancer patients admitted to the department of family medicine, National Health Insurance Corporation Ilsan hospital from March 1, 2002 to August 31, 2002. The study was done on 22 patients who were given 10 g/day of vitamin C infusions during 1 week and 27 patients who were not infused. We measured the cytokines levels ($IL-1{\beta}$, IL-6, and $TNF-{\alpha}$) before and after 1 week between terminal cancer patients treated vitamin C and without vitamin C. Results : Out of 49 patients, patents treated with vitamin C infusions were 22 (12 male, 10 female), and these without vitamin C were 27 (18 male, 9 female). In patients treated with vitamin C, $IL-1{\beta}\;were\;6.19{\pm}5.17$ before day and $8.76{\pm}5.72$ after 1 week, IL-6 were $3.07{\pm}8.09$ before day and $1.31{\pm}2.36$ after 1 week, and $TNF-{\alpha}\;were\;2.74{\pm}14.24$ before day and $0.50{\pm}2.00$ after 1 week. In patients treated without vitamin C, $IL-1{\beta}\;were\;2.50{\pm}3.58$ before day and $6.49{\pm}12.01$ after 1 week, IL-6 were $1.00{\pm}2.19$ before day and $17.16{\pm}81.55$ after 1 week, and $TNF-{\alpha}\;were\;1.19{\pm}2.98$ before day and $1.27{\pm}1.52$ after 1 week. The level of cytokines in patients treated with vitamin C decreased more than those without vitamin C. However, this represented no statistical value (P=0.0598 in $IL-1{\beta}$, P=0.1664 in IL-6, and P=0.5395 in $TNF-{\alpha}$). Conclusion : In terminal cancer, even if there was no statistical difference in the cytokines levels between patients treated with vitamin C and those not treated, those who were treated had a decrease all cytokines levels. Vitamin C is very safe with almost no side effects. Therefore, vitamin C treatment in terminal cancer patients can be seen as beneficial and helpful for clinical symptoms.

  • PDF

Packing effects on the intracavitary radiation Therapy 3-Dimension plan of the uterine cervix cancer (자궁경부암 강내조사 3차원 치료계획 시 Packing의 유용성 분석)

  • Si, Chang-Keun;Jo, Jung-Kun;Lee, Du-Hyun;Kim, Sun-Yeung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Purpose : An effect of a packing to uterine treatment of a cervical cancer using a dose-volume histogram for a point dose and a volume dose of the bladder and the rectum was analyzed by establishing a three-dimensional treatment plan using a CT image. Materials and methods : Reference points of the bladder and the rectum were marked, respectively at a treatment plan device (plato brachytherapy V14.2.4) by photographing CT(marconi, USA) when the packing was used and removed under the same condition and a treatment plan was performed to Apoint depending on ICRU38. However, in case of the rectum, a maximum point was looked up and compared with the above point because the point presented from the ICRU is not proper as a representative value of a rectum point dose. Further, the volume dose depending on volume of $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder was measured. The measured values were used to analyze the effect of the packing through a Wilcoxon Signed Rank Test (a SAS statistical analysis process program). Result : The reference points at the bladder and rectum doses when the packing was removed were $116.94\;35.42\%$ and $117.59\;21.08\%$, respectively. The points when the packing was used were $107.08\;38.12\%$ and $95.19\;21.32\%$, respectively. After the packing was used, the reference points at the bladder and the rectum were decreased by $9.86\%$ and $22.4\%$, respectively. When the packing was removed, the maximum points at the bladder and the rectum were $164.51\;50.89\%,\;128.81\;33.05\%$, respectively. When the packing was used, the maximum points at the bladder and the rectum were $142.31\;44.79,\;110.08\;37.03\%$, respectively. After the packing was used, the maximum points at the bladder and the rectum were decreased by $22.2\%$ and $18.73\%$, respectively. When the packing was removed, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $48.62{\pm}18.09\%,\;16.12{\pm}11.15\%,\;and\;7.51{\pm}6.63\%$, respectively and its rectum volume were $23.41{\pm}14.44\%,\;6.27{\pm}4.28\%,\;2.79{\pm}2.27\%$, respectively. When the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $40.33{\pm}16.72,\;11.63{\pm}8.72,\;and\;4.87{\pm}4.75\%$, respectively and its rectum volume were $18.96{\pm}8.37\%,\;4.75{\pm}2.58\%,\;and\;1.58{\pm}1.06\%$, respectively. After the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were decreased by $8.29\%,\;4.49\%,\;and\;2.64\%$, respectively and its bladder volume were decreased by $4.45\%,\;1.52\%,\;and\;1.21\%$, respectively. Conclusion : Values at Reference point doses of the bladder and the rectum recommended from the ICRU 38 were 0.0781 and 0.0781, respectively and values of their maximum point doses were 0.0156 and 0.0156, respectively, as a result of which an effect of the packing using at the uterine intracavitary treatment of an uterine cervical cancer through the three-dimensional treatment plan used CT were measured. That is, the values at reference point doses and the values at maximum point doses show similar difference. However, P value was 0.15 at over $50\%,\;80\%,\;and\;100\%$ volume doses and the value shows no similar difference. In other words, the effect of the packing looks like having a difference at the point dose, but actually shows no difference at the volume dose. The reason is that the volume of the bladder and the rectum are wide but the volume of the packing is only a portion. Therefore, the effect of decreasing the point dose was not great. Further, the farer the distance is, the more weak the intensity of radiation is because the intensity of radiation is proportional to inverse square of a distance. Therefore, the effort to minimize an obstacle of the bladder and the rectum by using the packing should be made.

  • PDF