• Title/Summary/Keyword: Wiener noise

Search Result 146, Processing Time 0.027 seconds

Efficiency of Median Modified Wiener Filter Algorithm for Noise Reduction in PET/MR Images: A Phantom Study (PET/MR 영상에서의 팬텀을 활용한 노이즈 감소를 위한 변형된 중간값 위너필터의 적용 효율성 연구)

  • Cho, Young Hyun;Lee, Se Jeong;Lee, Youngjin;Park, Chan Rok
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.225-229
    • /
    • 2021
  • The digital image such as medical X-ray and nuclear medicine field mainly contains noise distribution. The noise degree in image degrades image quality. That is why, the noise reduction algorithm is efficient for medical image field. In this study, we confirmed effectiveness of application for median modified Wiener filter (MMWF) algorithm for noise reduction in PET/MR image compared with median filter image, which is used as conventional noise redcution algorithm. The Jaszczak PET phantom was used by using 18F solution and filled with NaCl+NiSO4 fluids. In addition, the radioactivity ratio between background and six spheres in the phantom is maintained to 1:8. In order to mimic noise distribution in the image, we applied Gaussian noise using MATLAB software. To evlauate image quality, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used. According to the results, compared with noise image and images with MMWF algorithm, the image with MMWF algorithm is increased approximately 33.2% for CNR result, decreased approximately 79.3% for COV result. In conclusion, we proved usefulness of MMWF algorithm in the PET/MR images.

X-Ray Image Enhancement Using a Boundary Division Wiener Filter and Wavelet-Based Image Fusion Approach

  • Khan, Sajid Ullah;Chai, Wang Yin;See, Chai Soo;Khan, Amjad
    • Journal of Information Processing Systems
    • /
    • v.12 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • To resolve the problems of Poisson/impulse noise, blurriness, and sharpness in degraded X-ray images, a novel and efficient enhancement algorithm based on X-ray image fusion using a discrete wavelet transform is proposed in this paper. The proposed algorithm consists of two basics. First, it applies the techniques of boundary division to detect Poisson and impulse noise corrupted pixels and then uses the Wiener filter approach to restore those corrupted pixels. Second, it applies the sharpening technique to the same degraded X-ray image. Thus, it has two source X-ray images, which individually preserve the enhancement effects. The details and approximations of these sources X-ray images are fused via different fusion rules in the wavelet domain. The results of the experiment show that the proposed algorithm successfully combines the merits of the Wiener filter and sharpening and achieves a significant proficiency in the enhancement of degraded X-ray images exhibiting Poisson noise, blurriness, and edge details.

Wiener Filter Based Denoising Algorithm for Demosaicking (디모자이킹을 위한 Wiener Filter 기반의 디노이징 알고리듬)

  • Lee, Rok-Kyu;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.5C
    • /
    • pp.286-294
    • /
    • 2011
  • In most digital cameras, images are obtained by a sensor overlaid by the color filter array (CFA) such as Bayer, demanding a demosaicking procedure to rebuild the full resolution color images. However, due to the nature of sensor, it is necessary to consider denoising step to remove the noise. In this paper, we analyze demosaicking and denoising jointly and show that the proposed method can solve the denoising issue by simple manner, well suppress different level of noises. The proposed algorithm yields comparable performances measured by several image quality assessment (CPSNR, SCIELAB, and FSIM), while the computational cost is low.

Restoration of Bi-level Images via Iterative Semi-blind Wiener Filtering (반복 semi-blind 위너 필터링을 이용한 이진영상의 복원)

  • Kim, Jeong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1290-1294
    • /
    • 2008
  • We present a novel deblurring algorithm for bi-level images blurred by some parameterizable point spread function. The proposed method iteratively searches unknown parameters in the point spread function and noise-to-signal ratio by minimizing an objective function that is based on the binariness and the difference between two intensity values of restoring image. In simulations and experiments, the proposed method showed improved performance compared with the Wiener filtering based method in terms of bit error rate after segmentation.

Robust Multi-channel Wiener Filter for Suppressing Noise in Microphone Array Signal (마이크로폰 어레이 신호의 잡음 제거를 위한 강인한 다채널 위너 필터)

  • Jung, Junyoung;Kim, Gibak
    • Journal of Broadcast Engineering
    • /
    • v.23 no.4
    • /
    • pp.519-525
    • /
    • 2018
  • This paper deals with noise suppression of multi-channel data captured by microphone array using multi-channel Wiener filter. Multi-channel Wiener filter does not rely on information about the direction of the target speech and can be partitioned into an MVDR (Minimum Variance Distortionless Response) spatial filter and a single channel spectral filter. The acoustic transfer function between the single speech source and microphones can be estimated by subspace decomposition of multi-channel Wiener filter. The errors are incurred in the estimation of the acoustic transfer function due to the errors in the estimation of correlation matrices, which in turn results in speech distortion in the MVDR filter. To alleviate the speech distortion in the MVDR filter, diagonal loading is applied. In the experiments, database with seven microphones was used and MFCC distance was measured to demonstrate the effectiveness of the diagonal loading.

Enhancement of Evoked Potential Waveform using Delay-compensated Wiener Filtering (지연보상 위너 필터링에 의한 유발전위 파형개선)

  • Lee, JeeEun;Yoo, Sun K.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.261-269
    • /
    • 2013
  • In this paper, the evoked potential(EP) was represented by additive delay model to comply with the variational noisy response of stimulus-event synchronization. The hybrid method of delay compensated-Wiener filtered-ensemble averaging(DWEA) was proposed to enhance the EP signal distortion occurred during averaging procedure due to synchronization timing mismatch. The performance of DWEA has been tested by surrogated simulation, which is composed of synthesized arbitrary delay and arbitrary level of added noise. The performance of DWEA is better than those of Wiener filtered-ensemble averaging and of conventional ensemble averaging. DWEA is endurable up to added noise gain of 7 for 10 % mean square error limit. Throughout the experimentation observation, it has been demonstrated that DWEA can be applied to enhance the evoked potential having the synchronization mismatch with added noise.

Image quality enhancement using signal subspace method (신호 부공간 기법을 이용한 영상화질 향상)

  • Lee, Ki-Seung;Doh, Won;Youn, Dae-Hee
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.11
    • /
    • pp.72-82
    • /
    • 1996
  • In this paper, newly developed algorithm for enhancing images corrupted by white gaussian noise is proposed. In the method proposed here, image is subdivided into a number of subblocks, and each block is separated into cimponents corresponding to signal and noise subspaces, respectively through the signal subspace method. A clean signal is then estimated form the signal subspace by the adaptive wiener filtering. The decomposition of noisy signal into noise and signal subspaces in is implemented by eigendecomposition of covariance matrix for noisy image, and by performing blockwise KLT (karhunen loeve transformation) using eigenvector. To reduce the perceptual noise level and distortion, wiener filtering is implementd by adaptively adjusting noise level according to activity characteristics of given block. Simulation results show the effectiveness of proposed method. In particular, edge bluring effects are reduced compared to the previous methods.

  • PDF

Usefulness of Median Modified Wiener Filter Algorithm for Noise Reduction in Liver Cirrhosis Ultrasound Image (간경변 초음파 영상에서의 노이즈 제거를 위한 Median Modified Wiener Filter 알고리즘의 유용성)

  • Seung-Yeon Kim;Soo-Min Kang;Youngjin Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.911-917
    • /
    • 2023
  • The method of observing nodular changes on the liver surface using clinical ultrasonography is useful for diagnosing cirrhosis. However, the speckle noise that inevitably occurs in ultrasound images makes it difficult to identify changes in the liver surface and echo patterns, which has a negative impact on the diagnosis of cirrhosis. The purpose of this study is to model the median modified Wiener filter (MMWF), which can efficiently reduce noise in cirrhotic ultrasound images, and confirm its applicability. Ultrasound images were acquired using an ACR phantom and an actual cirrhotic patient, and the proposed MMWF algorithm and conventional noise reduction algorithm were applied to each image. Coefficient of variation (COV) and edge rise distance (ERD) were used as quantitative image quality evaluation factors for the acquired ultrasound images. We confirmed that the MMWF algorithm improved both COV and ERD values compared to the conventional noise reduction algorithm in both ACR phantom and real ultrasound images of cirrhotic patients. In conclusion, the proposed MMWF algorithm is expected to contribute to improving the diagnosis rate of cirrhosis patients by reducing the noise level and improving spatial resolution at the same time.

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

Bird sounds classification by combining PNCC and robust Mel-log filter bank features (PNCC와 robust Mel-log filter bank 특징을 결합한 조류 울음소리 분류)

  • Badi, Alzahra;Ko, Kyungdeuk;Ko, Hanseok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.1
    • /
    • pp.39-46
    • /
    • 2019
  • In this paper, combining features is proposed as a way to enhance the classification accuracy of sounds under noisy environments using the CNN (Convolutional Neural Network) structure. A robust log Mel-filter bank using Wiener filter and PNCCs (Power Normalized Cepstral Coefficients) are extracted to form a 2-dimensional feature that is used as input to the CNN structure. An ebird database is used to classify 43 types of bird species in their natural environment. To evaluate the performance of the combined features under noisy environments, the database is augmented with 3 types of noise under 4 different SNRs (Signal to Noise Ratios) (20 dB, 10 dB, 5 dB, 0 dB). The combined feature is compared to the log Mel-filter bank with and without incorporating the Wiener filter and the PNCCs. The combined feature is shown to outperform the other mentioned features under clean environments with a 1.34 % increase in overall average accuracy. Additionally, the accuracy under noisy environments at the 4 SNR levels is increased by 1.06 % and 0.65 % for shop and schoolyard noise backgrounds, respectively.