• Title/Summary/Keyword: Wide Range Monitoring

Search Result 270, Processing Time 0.03 seconds

Sensing Data Management System Using LoRa Based on Mobius Platform (모비우스 플랫폼 기반 LoRa 통신을 이용한 센싱 데이터 관리 시스템)

  • Park, Hwan;Kim, Mi-sun;Seo, Jae-hyun
    • Smart Media Journal
    • /
    • v.8 no.4
    • /
    • pp.9-16
    • /
    • 2019
  • In order to realize IoT(Internet of Things) service, it is necessary to manage sensing data and build a service with respect to its scalability. However, existing internet services use unique protocols and non-standardized functions for each service provider, and it is difficult to provide data management and service because they use short-range communication technology such as Bluetooth. In addition, plurality of APs and gateways must be taken into consideration in establishing a wide area network. In this paper, we propose a sensing data management system using LoRa(Long Range) communication based on Mobius platform. The end device that drives Tas is configured to collect sensing data, configure an application gateway that drives &Cube, and transmit sensing data to the server. In addition, a server that manages the Mobius is configured to handle the sensing data transmitted from the application gateway to provide a monitoring service. We establish a wide area network through LoRa communication between the end device and the gateway and provide data management and service corresponding to the internet through the Mobius platform.

An Optical Design of Off-axis Four-mirror-anastigmatic Telescope for Remote Sensing

  • Li, Xing Long;Xu, Min;Ren, Xian Dong;Pei, Yun Tian
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.243-246
    • /
    • 2012
  • An off-axis four-mirror-anastigmatic telescope is presented here which is composed of two aspheric surfaces and two spherical surfaces. The entrance pupil diameter is 290 mm and the stop is located at the primary mirror. The effective focal length is 900 mm. The strip field of view for the telescope is $15^{\circ}{\times}0.2^{\circ}$ and if the telescope is launched into an orbit about 400 km altitude, the observed range width will be more than 105 km within a scene without any other auxiliary scanning instrument. The spectral range can be as wide as from visual wave band to infrared wave band in the mirror system. This telescope can be used for environmental monitoring with different detectors whose pixel is adapted to the optical resolution. In this paper, the spectral range is chosen as 3.0 -5.0 ${\mu}m$, and center distance of the pixel is 30 ${\mu}m$. And the image quality is near the diffraction limit.

Experimental Study on Temperature Dependence of Nitrate Sensing using an ISE-based On-site Water Monitoring System

  • Jung, Dae-Hyun;Kim, Dong-Wook;Cho, Woo Jae;Kim, Hak-Jin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.122-122
    • /
    • 2017
  • Recently, environmental problems have become an area of growing interests. In-situ monitoring of water quality is fundamental to most environmental applications. The accurate measurement of nitrate concentrations is fundamental to understanding biogeochemistry in aquatic ecosystems. Several studies have reported that one of the most feasible methods to measure nitrate concentration is the use of Ion Selective-electrodes (ISEs). The ISE application to water monitoring has several advantages, such as direct measurement methodology, high sensitivity, wide measurement range, low cost, and portability. However, the ISE methods may yield inconsistent results where there was a difference in temperature between the calibration and measurement solutions, which is associated with the temperature dependence of ionic activity coefficients in solution. In this study, to investigate the potential of using the combination of a temperature sensor and nitrate ISEs for minimizing the effect of temperature on real-time nitrate sensing in natural water, a prototype of on-site water monitoring system was built, mainly consisting of a sensor chamber, an array of 3 ISEs, an waterproof temperature sensor, an automatic sampling system, and an arduino MCU board. The analog signals of ISEs were obtained using the second-order Sallen-key filter for performing voltage following, differential amplification, and low pass filtering. The performance test of the developed water nitrate sensing system was conducted in a monitoring station of drinking water located in Jeongseon, Kangwon. A temperature compensation method based on two-point normalization was proposed, which incorporated the determination of temperature coefficient values using regression equations relating solution temperature and electrode signal determined in our previous studies.

  • PDF

Multiplexed Hard-Polymer-Clad Fiber Temperature Sensor Using An Optical Time-Domain Reflectometer

  • Lee, Jung-Ryul;Kim, Hyeng-Cheol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Optical fiber temperature sensing systems have incomparable advantages over traditional electrical-cable-based monitoring systems. However, the fiber optic interrogators and sensors have often been rejected as a temperature monitoring technology in real-world industrial applications because of high cost and over-specification. This study proposes a multiplexed fiber optic temperature monitoring sensor system using an economical Optical Time-Domain Reflectometer (OTDR) and Hard-Polymer-Clad Fiber (HPCF). HPCF is a special optical fiber in which a hard polymer cladding made of fluoroacrylate acts as a protective coating for an inner silica core. An OTDR is an optical loss measurement system that provides optical loss and event distance measurement in real time. A temperature sensor array with the five sensor nodes at 10-m interval was economically and quickly made by locally stripping HPCF clad through photo-thermal and photo-chemical processes using a continuous/pulse hybrid-mode laser. The exposed cores created backscattering signals in the OTDR attenuation trace. It was demonstrated that the backscattering peaks were independently sensitive to temperature variation. Since the 1.5-mm-long exposed core showed a 5-m-wide backscattering peak, the OTDR with a spatial resolution of 40 mm allows for making a sensor node at every 5 m for independent multiplexing. The performance of the sensor node included an operating range of up to $120^{\circ}C$, a resolution of $0.59^{\circ}C$, and a temperature sensitivity of $-0.00967dB/^{\circ}C$. Temperature monitoring errors in the environment tests stood at $0.76^{\circ}C$ and $0.36^{\circ}C$ under the temperature variation of the unstrapped fiber region and the vibration of the sensor node. The small sensitivities to the environment and the economic feasibility of the highly multiplexed HPCF temperature monitoring sensor system will be important advantages for use as system-integrated temperature sensors.

Log Count Rate Circuits for Checking Electronic Cards in Low Frequency Band Reactor Power Monitoring (저주파수대의 원자로 출력신호 점검을 위한 대수 카운트레이트 회로)

  • Kim, Jong-ho;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.557-565
    • /
    • 2020
  • In order for thermal degradationIn, excore nuclear flux monitoring system, as a monitoring and signal processing methodology of reactor power, monitors neutron pulses generated during nuclear fission as frequency status, and converts them into DC voltage, and then log values resultantly. The methods realy applied in the nuclear power plant are to construct combination of counters and flip-flops, or diodes and capacitors up to now. These methodes are reliable for relative high frequencies, while not credible for reasonable low frequencies or extreme low values. Therefore, we developed the circuit that converts frequencies into DC voltages, into and into log DC values in the wide range from low Hz to several hundred high kHz. We proved their validities through testing them using real data used in nuclear power plant and analyzed their results. And, these methods will be used to measure the neutron level of excore nuclear flux monitoring system in nuclear power plant.

Pesticide Residue Monitoring and Environmental Exposure in Paddy Field Soils and Greenhouse Soils (전국 논토양과 시설하우스 토양 중 잔류농약 모니터링과 환경 노출성)

  • Park, Byung-Jun;Lee, Ji-Ho
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.2
    • /
    • pp.134-139
    • /
    • 2011
  • To investigate an amount of pesticide residue in rice paddy field soils and greenhouse soil, this monitoring was carried out pesticide detection frequency and concentrations collected samples from 150 rice paddy field soils and 152 greenhouse soils of nationwide in the year of 2007, and 2008, respectively. The detection limit of pesticides of this experiment were ranged 0.001~0.005 ppm. In 2007, One hundred fifty samples were collected from rice paddy field soils in April and monitored for 120 wide-used pesticides. A total of 11 pesticides were detected four fungicides, four insecticides and three herbicides in paddy field soils. The highest concentration levels of pesticide detected were 0.84 ppm as herbicide oxadiazon, 0.81 ppm as fungicide isoprothiolane and 0.50 ppm as insecticide buprofezin. The detection frequencies range were 0~19.3%, and the frequency was 2.7% as isoprothiolane and 19.3% as oxadiazon in paddy field soils. In 2008, One hundred fifty two samples were collected from greenhouse soils in April and monitored for 120 wide-used pesticides. A total of 29 pesticides were detected six fungicides, sixteen insecticides and seven herbicides in greenhouse soils. high concentration levels of pesticide detected levels were 5.09 ppm as insecticide chlorfenapyr, 2.57 ppm as fungicide chlorothalonil and 0.72 ppm as herbicide oxadiazon. The detection frequencies range were 0~38.8%, and high frequencies were 38.8% as insecticide endosulfan, 13.2% as oxadiazone, 10.5% as fungicide hexaconazole and 7.2% as isoprothiolane in greenhouse soils, Total endosulfan and oxadiazon were showed high detection frequency of 38.8% and 13.2%, respectively.

Development of Smart Remote Terminal Unit for Water Treatment SCADA System (상하수도 원격감시제어 시스템 구현을 위한 스마트 RTU의 개발 및 적용)

  • Jang, Sang-Bok;Lee, Ho-Hyun;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • In this paper, a new remote terminal unit(hereafter RTU) is proposed to manage a wide range of applications and a variety of sensors (eg, pressure, water quality, temperature and humidity sensors, the amount of pollutants, $CO_2$, etc.) to monitor and control the facility such as water treatment plant, intake and effluent pumping station, water tank and distribution network. Fault status of local sensor devices and network are alerted by using the embedded fault handling capabilities of the RTU in the system and also sent to the fault handling server, by which fault can be easily monitored to users. The developed system was applied to one of K-water branch offices in Geoje city and improved its reliability and stability for controlling and monitoring water facility.

Health-monitoring and system-identification of an ancient aqueduct

  • Chrysostomou, Christis Z.;Stassis, Andreas
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.183-194
    • /
    • 2008
  • An important historical monument of Cyprus is an aqueduct that was built in 1747 to provide water to the city of Larnaca and to its port. Because of its importance to the cultural heritage of Cyprus, the aqueduct has been selected as one of the case-study monuments in the project Wide-Range Non-Intrusive devices toward Conservation of Historical Monuments in the Mediterranean Area (WIND-CHIME). Detailed drawings of the aqueduct obtained from the Department of Antiquities of Cyprus have been used for the development of a computational model. The model was fine-tuned through the measurement of the dynamic characteristics of the aqueduct using forced and ambient vibrations. It should be noted that measurement of the dynamic characteristics of the structure were performed twice in a period of three years (June of 2004 and May of 2007). Significant differences were noted and they are attributed to soil structure interaction effects due to seasonal variations of the water-level in a nearby salt-lake. The system identification results for both cases are presented here. This monument was used to test the effectiveness of shape memory alloy (SMA) pre-stressed devices, which were developed during the course of the project, in protecting it without spoiling its monumental value.

Development of Dark-striped Field Mice, Apodemus agrarius, as a Biological Dosimeter in a Radio-ecological Monitoring System 3. Radio-sensitivity between A. agrarius and ICR Mice

  • Kim Hee-sun;Nishimura Y.;Jin Young-Woo;Kim Chong-Soon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.513-517
    • /
    • 2005
  • This study examined the possibility of using striped field mice as a biological dosimeter or indicator for the environmental radio-surveillance. For this study, the external morphological characteristics and isoenzymic types of dark-striped field mice were studied after they were captured. Among the morphological external characteristics, the dark-brown coat, dark back stripe, head-to-tail length, tail length, and ear length matched the taxonomical characteristics of dark-striped field mice. The analyses on L-lactate dehydrogenase, aspartate aminotransferase, and malate dehydrogenese revealed that one species of dark-striped field mice, called Apodemus agrarius, was inhabitated throughout a wide range of Korea. On the other hand, A. agrarius and ICR mice to analyze their survival rate and frequency of micronuclei in peripheral polychromatic erythrocytes after irradiation (0, 0.5, 1, 3, 5, 7, 9 Gy). The $LD_{50/30}$ of A. agrarius and ICR mice were approximately 5 Gy and 7Gy, respectively. The results of the study reveal that wild A. agrarius have a high potential as a biological monitoring system to determine the impact of radiation effect in areas such as those within the vicinity of nuclear power plants.

  • PDF

Small size IoT Device Monitoring System Modeling applying DEVS methodology

  • Lee, Se-Han;Seo, Hee-Suk;Choi, Yo-Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.2
    • /
    • pp.45-51
    • /
    • 2018
  • In this paper, we propose a Designed and Developed home router management system. Through the fourth industrial revolution and development of IoT technology, now people can experience a wide range of IoT related services at their workplace or daily lives. At the industrial site, IoT devices are used to improve productivity such as factory automation, and at home, IoT technology is used to control home appliances from a remote distance. Usually IoT device is integrated and controlled by the router. Home router connects different IoT devices together at home, however when security issues arise, it can invade personal privacy. Even though these threats exist, the perception for home router security is still insufficient. In this paper, we have designed and developed home router management system using DEVS methodology to promote the safe use of home router. Through the DEVS methodology, we have designed the system and developed the mobile application. This management system enables users to set up security options for home router easily.