• 제목/요약/키워드: Whole-body scan

검색결과 179건 처리시간 0.021초

갑상선암 환자에서 I-131의 진단적 전신스캔과 치료후 전신스캔의 비교 (Comparision of I-131 Diagnostic Scan and Therapeutic Scan in Thyroid Carcinoma)

  • 이범우;이동수;문대혁;정준기;이명철;조보연;고창순
    • 대한핵의학회지
    • /
    • 제24권1호
    • /
    • pp.80-86
    • /
    • 1990
  • Fifty seven patients with differentiated thyroid carcinoma were performed radioactive iodine-131 whole body scans after administration of diagnostic dose $(2\sim10\;mCi)$ and therapeutic dose $(30\sim150\;mCi)$ within three months. We evaluated the state of radioactive iodine-131 uptakes in whole body scan to detect correct metastasis of thyroid carcinoma. The results are as follows: 1) In 20 of the 57 patients (35%), the therapeutic scan showed the additional uptakes that were not seen in the diagnostic scan. 2) In 9 (64.2%) of the 14 patients who had been received the thyroid ablation theraphy with I-131 previously, new additional lesions were found in the therapeutic scan but only 11 (25%) of the 32 patients who had not been received the thyroid ablation theraphy disclosed new uptake lesions (p < 0.01). 3) The additional uptake lesions of therapeutic scan were significantly more common in the bony metastatic foci (55.7%) than other areas (p < 0.01). In 11 (55%) of 20 patients, additional uptake regions were anterior neck areas (thyroid bed or regional lymph node). We conclude that diagnostic scan with $2\sim5$ mCi I-131 is inadequate in evaluating residual iodine avid tissues of patients with thyroid carcinoma. Also post-theraphy I-131 whole body scan would be important to evaluate the correct staging and prognosis of thyroid carcinoma, and to follow-up patients.

  • PDF

Oncoflash를 적용한 전신 뼈 영상 검사의 스캔 속도 결정에 관한 연구 (A Study on the Determination of Scan Speed in Whole Body Bone Scan Applying Oncoflash)

  • 양광길;정우영
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.56-60
    • /
    • 2009
  • 전신 뼈 영상 검사에서 영상의 질을 유지하면서 검사 시간 단축을 위해 oncoflash와 같은 프로그램을 사용하고 있는데, 이를 임상에 적용할 때 영상의 질과 검사 시간 단축의 두 가지 측면을 동시에 고려해야 하며, 적합한 스캔 속도의 결정에 대한 기준 설정이 필요하여 본 연구를 시행하였다. 서울아산병원 핵의학과에서 전신 뼈 영상 검사를 시행한 환자를 대상으로 하여 분당 30 cm의 스캔 속도로 검사한 영상의 총 계수를 각각 800 K 이하, 800 K, 900 K, 1000 K, 1500 K, 2000 K 이상으로 구분하여 영상의 질을 정성적 분석하고, 전신 총 계수가 1000 K 미만인 비율을 분석하였다. 분당 30 cm의 스캔 속도로 검사한 전신 뼈 영상의 전신 총 계수의 기하학적 평균이 1000 K 미만인 비율을 분석한 결과, 전체 329명 중 58명(17.6%)이다. 전신 총 계수 별로 구분한 영상을 정성적으로 분석 결과, 전신 총 계수 1000 K 이하의 경우에 육안적으로 영상의 입자가 거칠고, 노이즈가 증가한 영상으로 평가되었다. 전신 총 계수의 양과 Oncoflash 적용 여부에 따른 해상력의 비교평가를 위해 전신 뼈 영상 검사의 계수율을 고려하여 2~5 mCi의 선량을 투여한 $^{99m}Tc$ Flood와 4-Quadrant bar phantom을 이용하여 영상을 획득 한 후, Oncoflash 적용 전과 후의 FWHM을 분석하였다. PPM 계수가 3.6 K 이하에서는 Oncoflash 적용 후의 FWHM이 전과 비교해서 높게 나왔으나, 3.6~4.0 K 이상에서는 Oncoflash 적용 전보다 적용 후에 낮거나 동등하게 측정되었다. 전신 뼈 영상 검사의 시작 시점인 두부와 흉부의 일부가 포함된 상태에서 감마카메라의 PPM (Patient Positioning Monitor) 계수를 측정하고, 분당 30 cm의 스캔 속도를 적용하여 획득한 전신 총 계수 사이의 상관 관계를 분석 결과는 PPM 계수가 각각 2.5~3.0 K일 때 전신 총 계수의 평균과 표준 편차는 $965{\pm}173\;K$ (17.8%), 3.1~3.5 K에서 $1,084{\pm}154\;K$ (22.4%), 3.6~4.0 K에서 $1,242{\pm}186\;K$ (18.4%), 4.1~4.5 K에서 $1,359{\pm}170\;K$ (17.1%), 4.6~5.0 K에서 $1,405{\pm}184$ K (10.5%), 5.1~6.0에서 $1,640{\pm}376\;K$ (10.5%), 6.1~7.0 K에서 $1,771{\pm}324\;K$ (1.3%), 7.1 K 이상에서 $1,972{\pm}385\;K$ (2.0%)으로, 매우 강한 양의 상관관계(상관계수 r=0.775, p<0.01)가 있었다. 전신 뼈 영상 검사 시작 시점의 PPM 계수가 3.6 K 이상일 경우에 분당 30 cm으로 스캔한 후 전신 총 계수가 1000 K 이상인 경우에 Oncoflash를 적용하면 검사 시간을 줄이면서도 기존의 분당 15 cm으로 획득한 영상 수준의 화질을 얻을 수 있었다. 그러나 분당 30 cm으로 스캔한 후 전신 총 계수 기준으로 1000 K 미만인 경우에는 Oncoflash를 적용하여도 영상의 질이 저하되므로, 기존의 분당 15 cm의 속도로 다시 시행하는 것을 고려해야 할 것이다.

  • PDF

전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구 (The Accuracy of the Table Movement During a Whole Body Scan)

  • 이주영;정우영;정은미;동경래
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.86-91
    • /
    • 2009
  • 전신 영상 검사는 일반적인 핵의학 검사에 적용되고 있는 가장 기본적인 촬영 방법 중 하나이다. 이 때 각 검사마다 규정화된 테이블 이동 속도는 다양하다. 본 연구에서는 감마카메라의 사용 기간에 따른 노후 상태와 감마카메라 테이블 위의 무게 변화에 따른 테이블 이동 속도를 측정하여 그 정확성을 분석하는데 그 목적이 있다. 2008년 12월부터 2009년 2월까지 서울아산병원 핵의학과내에서 전신 영상 검사를 주로 시행하는 SIEMENS 장비 중 가장 사용기간이 긴 ECAM plus와 가장 최근에 설치된 SYMBIA T2를 대상으로 연구를 실시하였다. 각 장비별로 테이블 이동속도를 10, 15, 30 cm/min으로 나누어 매 10 cm씩 마다 총 100 cm의 구간을 타이머를 이용해 테이블 이동 시간을 측정하였다. 또한 표준 체중을 60~70 kg으로 감안하여 0, 66, 110 kg으로 나누어 체중에 따른 테이블의 이동 속도를 동일한 방법으로 측정하여 비교 분석하였다. 본 연구에서는 10 cm/min, 15 cm/min, 30 cm/min의 변동계수가 ECAM plus에서 1.23, 1.42, 2.02이었고, SYMBIA T2에서 1.23, 1.83, 2.28이었으며 테이블 이동속도가 증가될수록 변동은 많았다. 또한 무게 변화에 따른 각각의 변동계수는 0 kg에서 0.96, 1.45, 2.08이었고, 66 kg에서 1.32, 1.72, 2.27이며, 110 kg에서 1.37, 1.73, 2.14로 무게에 따른 큰 차이는 없었다. 95% 신뢰수준에서 통계적으로 유의한 차이는 있지 않아(p>0.05) 두 장비 모두 허용할 수 있는 범위안에 있었지만, ECAM plus에 비해 SYMBIA T2의 변동계수가 비교적 크게 측정되었다. 이러한 결과를 미루어 볼 때 Onco. Flash와 같은 Half-time 검사법을 실시하기 전에는 테이블의 이동과 테이블 이동 속도, 감마카메라의 상태를 점검하고, 좀 더 관심을 기울여야 하며 정기적인 점검을 일반화시키는 것이 유용할 것이라고 생각된다.

  • PDF

3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교- (Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry-)

  • 백경자;이정란
    • 한국의류학회지
    • /
    • 제32권1호
    • /
    • pp.24-34
    • /
    • 2008
  • Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.

CNN 기반 전이학습을 이용한 뼈 전이가 존재하는 뼈 스캔 영상 분류 (Classification of Whole Body Bone Scan Image with Bone Metastasis using CNN-based Transfer Learning)

  • 임지영;도탄콩;김수형;이귀상;이민희;민정준;범희승;김현식;강세령;양형정
    • 한국멀티미디어학회논문지
    • /
    • 제25권8호
    • /
    • pp.1224-1232
    • /
    • 2022
  • Whole body bone scan is the most frequently performed nuclear medicine imaging to evaluate bone metastasis in cancer patients. We evaluated the performance of a VGG16-based transfer learning classifier for bone scan images in which metastatic bone lesion was present. A total of 1,000 bone scans in 1,000 cancer patients (500 patients with bone metastasis, 500 patients without bone metastasis) were evaluated. Bone scans were labeled with abnormal/normal for bone metastasis using medical reports and image review. Subsequently, gradient-weighted class activation maps (Grad-CAMs) were generated for explainable AI. The proposed model showed AUROC 0.96 and F1-Score 0.90, indicating that it outperforms to VGG16, ResNet50, Xception, DenseNet121 and InceptionV3. Grad-CAM visualized that the proposed model focuses on hot uptakes, which are indicating active bone lesions, for classification of whole body bone scan images with bone metastases.

전신 뼈검사에서의 영상 평가 연구 (Study on Image Quality Assessment in Whole Body Bone Scan)

  • 권오준;허재;이한울;김주연;박민수;노동욱;강천구;김재삼
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.30-36
    • /
    • 2015
  • 전신 뼈검사는 골수염과 골절 및 원발성 암의 조기 발견 등골 병변에 대해 높은 민감도와 해상도를 가진 검사이며, 핵의학 검사 중 가장 많은 비중을 차지하고 있다. 그러나 최저 계수치를 제외한 평가 기준이 마련되어 있지 않다. 따라서, 본 연구에서 전신 뼈검사에서 정량적인 평가 지표를 나타낼 수 있는 방법을 분석해보고자 하였다. 본 연구는 2014년 4월부터 2014년 9월까지 본원을 내원한 특이 골병변소견이 없는 환자 30명을 대상으로 GE INFINIA 장비에서 진행하였다. 환자의 전신계수와 허리뼈를 관심영역으로 하여, 계수치를 측정하였으며, 허리뼈 각각의 신호평균 값과 표준편차를 구하여, 대조도 대 잡음비(Contrast to Noise Ratio, CNR), 신호 대 잡음비(Signal to Noise Ratio, SNR)를 산출하였고, 팬텀 실험을 통해 검사 속도 변화에 따른 각각의 수치와 조직등가물질을 이용하여 복부 두께에 따른 수치를 비교 하였다. 그리고, 판독의 2명과 5년 이상의 경력을 가진 숙련된 방사선사 5명이 각각 10점 척도로 하여, Blind test로 육안적인 분석치와 정량적인 산출치 간의 상관관계를 분석하였다. 환자의 전신 계수치와 관심영역의 계수치는 Blind test를 통한 육안적인 분석치와 유의한 상관관계를 보이지 않았다(P>0.05). 대조도 대 잡음비와 신호 대 잡음비는 육안적인 분석치와 유의한 상관관계를 보였다(P<0.05). 팬텀 실험에서는 검사 속도가 느릴수록, 조직등가물질의 두께가 얇을수록 각 수치는 향상되는 것을 보였으며, 지연검사에서 영상의 질이 향상됨을 확인하였다. 현재 전신 뼈검사에서 최저 계수치를 제외한 평가 기준이 마련되어있지 않다. 이에 본 연구에서는 대조도 대 잡음비 및 신호 대 잡음비를 이용하여 Blind test와의 유의한 상관관계를 확인 할 수 있었으며, 검사 속도가 영상의 질을 좌우하는 인자라는 것을 수치를 통해 확인하였다. 본 연구에서는 동일한 주입량, 동일한 검사 속도 등 동등한 조건에서의 평가를 진행하였지만, 환자의 생리적 기능과 수분 섭취량 등에 따라 모든 특성을 고려하는 것에 한계가 존재한다. 그러나 객관적으로 정량적 수치를 제시하여, 유의한 평가 지표를 입증하였다는 데에 학술적 의미가 있을 것으로 사료된다.

  • PDF

F-18-FDG감쇠보정 전신 PET을 이용한 표준섭취계수 추정과 매개변수 영상의 구성 (Parametric Images of Standardized Uptake Values using P-18-FDG Attenuation Corrected Whole Body PET)

  • 김경민;곽철은;이동수;정재민;정준기;이명철;고창순;김영진
    • 대한핵의학회지
    • /
    • 제30권4호
    • /
    • pp.560-569
    • /
    • 1996
  • F-18-FDG 전신 PET을 촬영하여 분할/편평화 방법으로 감쇠보정한 전신 영상을 만들었으며 이어 SUV 매개변수 영상을 구성하여, 측정한 것을 그대로 사용한 방법과 분할/편평화 후에 감쇠보정하는 방법에 따라 SUV 추정 성능이 달라지는지 보았다. 모형실험의 결과 SUV 계산식이 적절함을 확인하였고 측정 감쇠보정 방법에 비해 분할/편평화 감쇠보정 방법을 이용하여 만든 영상이 화질이 우수하고, 구한 SUV 값은 국소스캔에 의한 SUV에 비해 측정 감쇠보정 방법은 SUV가 조금 높게, 분할/편평화 감쇠보정 방법은 조금 낮음을 알았다 환자를 대상으로 적용한 결과 분할/편평화 방법으로 감쇠보정한 전신 영상의 화질은 우수하여 판독에 적합하였다. 환자 국소 매개변수 영상과 전신 매개변수 영상에서 병소부위의 SUV는 감쇠방법에 따라 작은 차이가 있었다. 23명의 환자에서 전신 SUV는 분할/편평화 감쇠보정 방법을 사용한 경우 국소스캔에서 얻은 SUV보다 조금 낮았다. 전신SUV를 측정한 것을 그대로 사용하여 얻으면 국소스캔에서 얻은 SUV보다 조금 덜 낮았다. SUV를 측정할 때 개입하는 병변의 특성이 뚜렷한 차이를 보이는 것을 고려할 때 우리가 발견한 방법간 SUV값의 차이는 상대적으로 작아 분할/편평화 후 감쇠보정 방법을 이용한 전신 SUV 매개변수 영상에서 얻은 SUV를 국소스캔에서 측정한 SUV와 서로 바꾸어 사용하여도 좋다고 생각한다.

  • PDF

3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 - (The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner -)

  • 박선미;남윤자
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

유방암 환자에서 전신 뼈 검사 후 감시림프절 위치 파악 검사의 유용성 (Usefulness of Breast Lymphoscintigraphy after Whole Body Bone Scan)

  • 장동근;반영각;정석;박훈희;강천구;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.133-137
    • /
    • 2010
  • 유방암은 다른 장기에 비하여 뼈 전이와 임파절 전이가 잘 일어나는 질환으로 알려져 있으며, 유방암 수술 전, 후로 핵의학 검사인 전신 뼈 검사와 감시림프절 검사가 많이 시행되고 있다. 감시림프절 위치 파악 검사는 감시림프절에 정확 위치를 파악을 위해 시행되며, 유방암 수술 시 감시림프절을 파악 하는데 중요한 정보를 제공해 주게 된다. 본 연구에서는 감시림프절 위치 파악 검사 시 해부학적인 위치정보를 좀 더 명확하게 하기 위해 감시림프절 위치 파악 검사 전날 전신 뼈 검사를 시행하여 기존에 Flood 선원을 이용한 방법과 비교 평가하여 영상의 유용성에대해 알아보고자 하였다. 2009년 1월부터 12월까지 본원에서 전신 뼈 검사와 감시 림프절 검사를 2일에 걸쳐 시행한 환자 22명(평균나이 $52{\pm}7.2$세)을 대상으로 하였고, 대조군으로는 $^{57}Co$ flood phantom을 이용하여 감시림프절에 위치를 파악한 환자 22명(평균나이 $57{\pm}6.5$세)을 대상으로 하였다. 정량적인 분석 방법으로 전신 뼈 검사 후에 감시림프절 검사를 시행한 영상에 감시림프절과 배후방사능에 관심영역을 그려 상대적 비율을 측정하였으며, 육안적인 분석 방법으로 전신 뼈 검사 후 감시림프절 검사를 진행한 영상과 $^{57}Co$ flood phantom을 이용한 영상을 핵의학과 전문의와 5년 이상의 실무경험을 가진 방사선사가 각각 5점 척도로 하여, Blind test하였다. 정량적인 분석 결과 감시림프절에 대해 배후방사능이 미치는 영향은 전면상에서 최대 14.2:1, 평균 8:1(SD${\pm}$3.48), 측면상에서 최대 14.7:1, 평균 8.5:1(SD${\pm}$3.42)값으로 감시림프절에 대해 배후방사능에 차이가 크게 나타났고, 전면상과 측면상에서도 큰 차이가 없었다. 육안적인 분석 결과 $^{57}Co$ flood phantom 영상과 뼈가 포함된 영상을 비교한 결과 $^{57}Co$ flood phantom 영상 $3.86{\pm}0.35$점, 뼈 영상이 $4.09{\pm}0.42$점으로 $^{57}Co$ flood phantom 영상 보다 높은 점수를 나타내었다. 감시림프절 위치 파악 검사에 경우 검사 전날 전신 뼈 검사를 진행하였을 때에 뼈의 배후방사능과 감시 림프절에 비율차이가 평균 8:1 이상으로 림프절에 위치를 파악 하는데 문제가 없었다. 또한 전신 뼈 영상을 체표윤곽도로 이용하게 되면, 다른 선원을 이용하지 않고도 감시림프절에 위치정보를 나타낼 수 있어서 술자와 환자의 불필요한 피폭을 방지하며, 영상의 질적 향상을 기대할 수 있을 것으로 사료 된다.

  • PDF