Combined MRI and Relaxogram: A New Method of Fat Study (MRI와 Relaxogram을 이용한 지질 연구의 새로운 기법에 관한 연구)

  • Yongmin Chang;Yoo, Done-Sik;Kim, Tae-Hun;Kim, Yong-Joo;Kang, Duk-Sik;Robert B. Clarkson
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.23-32
    • /
    • 1999
  • Combined MRI and Relaxogram approach was introduced as a very useful tool for fat study. The phantoms simulating homogeneous mixture of fat and non-fat environments were measured with spin echo pulse sequence on a 0.15 T whole body imager. From 45 scans, the Tl values were obtained by fitting the data to continuous distribution (CONTIN) of relaxation time. This relaxogram gives broad distributions of relaxation time, which are characterized by a number of peaks with characteristic T1 values. Two distinct peaks in relaxogram were observed and identified as signals from com oil and gelatin gel. This model system can be served as simulating the distribution of fat in muscle. Also the relative ratio of two components, which is proportional to the area under the peak, is estimated and compared to nominal values. Based on the good agreement between two predictions, the values from our proposed method agreed with nominal values within $\pm$7 % error. The effects of different concentration of contrast agent and different region of interest are presented. To optimize total scan times, the minimum required data points and so further reduction in total scan times are discussed.

  • PDF

Contrast-enhanced Magnetic Resonance Imaging of Brain Metastases at 7.0T versus 1.5T: A Preliminary Result

  • Paek, Sun Ha;Kim, Jhi-Hoon;Choi, Sung-Hong;Yoon, Tae-Jin;Son, Young Don;Kim, Dong Gyu;Cho, Zang-Hee;Sohn, Chul-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.1
    • /
    • pp.31-36
    • /
    • 2015
  • Purpose: To compare the depiction of brain metastases on contrast-enhanced images with 7.0 tesla (T) and at 1.5T MRI. Materials and Methods: Four consecutive patients with brain metastases were scanned on 7.0T whole-body scanner and 1.5T MRI. A 3D T1-weighted gradient echo sequence (3D T1-GRE) at 1.5T (voxel size = $0.9{\times}0.9{\times}1.5mm^3$ after double-dose, gadoterate meglumine, Gd-DOTA) was compared to a 7.0T 3D T1-GRE sequence (voxel size = $0.4{\times}0.4{\times}0.8mm^3$, single-dose Gd-DOTA) in four patients after a 5 minute delay. The number of contrast-enhancing metastases in MPRAGE images was compared in each patient by two radiologists in consensus. We measured contrast ratio of enhancing brain metastases and white matter in 1.5T and 7.0T. Results: In all four patients 7.0T 3D T1-GRE images after single-dose Gd-DOTA and 1.5T after double-dose Gd-DOTA depicted 11 brain metastases equally. In the quantitative analysis of contrast ratios of enhancing brain metastases and white matter, the 1.5T 3D T1-GRE after double-dose showed an increased contrast ratio compared to 7.0T 3D T1-GRE after single-dose ($0.961{\pm}0.571$ versus $0.885{\pm}0.494$; n = 11 metastases). But this difference was not statistically significant (P = 0.711). Conclusion: Our preliminary results indicate that 7.0T single-dose Gd-enhanced images were not different to 1.5T double-dose Gd-enhanced images for the detection of brain metastases.

Projection-type Fast Spin Echo Imaging (프로젝션 타입 고속 스핀 에코 영상)

  • 김휴정;김치영;김상묵;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.42-51
    • /
    • 2000
  • Purpose: Projection-type Fast Spin Echo (PFSE) imaging is robust to patient motion or flow related artifact compared to conventional Fast Spin Echo (FSE) imaging, however, it has difficulty in controlling $T_2$ contrast. In this paper, Tz contrast in the PFSE method is analyzed and compared with those of the FSE method with various effective echo times by computer simulation. The contrasts in the FSE and PFSE methods are also compared by experiments with volunteers. From the analysis and simulation, it is shown that ${T_2}-weighted$ images can well be obtained by the PFSE method proposed. Materials and methods: Pulse sequence for the PFSE method is implemented at a 1.0 Tesla whole body MRI system and $T_2$ contrasts in the PFSE and FSE methods are analyzed by computer simulation and experiment with volunteers. For the simulation, a mathematical phantom composed of various $T_2$ values is devised and $T_2$ contrast in the reconstructed image by the PFSE is compared to those by the FSE method with various effective echo times. Multi-slice ${T_2}-weighted$ head images of the volunteers obtained by the PFSE method are also shown in comparison with those by the FSE method at a 1.0 Tesla whole body MRI system. Results: From the analysis, $T_2$ contrast by the PFSE method appears similar to those by the FSE method with the effective echo time in a range of SO-lOOms. Using a mathematical phantom, contrast in the PFSE image appears close to that by the FSE method with the effective echo time of 96ms. From experiment with volunteers, multi-slice $T_2-weighted$ images are obtained by the PFSE method having contrast similar to that of the FSE method with the effective echo time of 96ms. Reconstructed images by the PFSE method show less motion related artifact compared to those by the FSE method. Conclusion: The projection-type FSE imaging acquires multiple radial lines with different angles in polar coordinate in k space using multiple spin echoes. The PFSE method is robust to patient motion or flow, however, it has difficulty in controlling $T_2$ contrast compared to the FSE method. In this paper, it is shown that the PFSE method provides good $T_2$ contrast (${T_2}-weighted$ images) similar to the FSE method by both computer simulation and experiments with volunteers.

  • PDF

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

Metabolic Abnormalities in Patients with Mitochondrial Myopathy Evaluated by In Vivo $^{31}$P Magnetic Resonance Spectroscopy (인($^{31}$P) 자기공명분광법을 사용하여 사립체 근질병환자와 정상인과의 대사물질 비교조사)

  • Bo-Young Choe
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.89-95
    • /
    • 1998
  • Purpose : To investigate the phosphorus metabolic abnormalities in skeletal muscle of patients with mitochondrial myopathy using in vivo $^{31}P$ magnetic resonance spectroscopy(MRS). Materials and Methods : Patients with mitochondrial myopathy(N=10) and normal control subjects (N=10) participated. All in vivo $^{31}P$ MRS examinations were performed on 1.5T whole-body MRI/MRS system by using an image selected in vivo spectroscopy (ISIS) pulse sequence that provided a $4{\times}4{\times}4{\;}cm^{3}$ volume of interest (VOI) in the right thigh muscle tissue. Peak areas for each phophorus methabolite were measured using a Marquart algorithm. Results : The specific features in patients with mitochondrial myopathy were a significant increase of Pi/PCr ratio (p=0.003) and a significant decrease of ATP/PCr ratio (p=0.004) as compared with normal controls. In particular, the ${\beta}-ATP/PCr$ ratio between controls and patients with mitochondrial myopathy was predominantly altered. Conclusions : In vivo $^{31}P$ MRS may be a useful modality in the clinical evaluation of patients with mitochondrial myopathy based on ATP/PCr and Pi/PCr ratios in skeletal muscle tissue and provides a valuable information in further understanding disorders of muscle metabolism.

  • PDF

A Case of Spinal Cord Compression Caused by Rhabdomyosarcoma of the Mediastinum Associated with Type I Neurofibromatosis(NF Type I) - Case Report - (제 I 형 신경섬유종증에 병발하였던 종격동내 횡문근육종에 의한 척수압박 1례 - 증례보고 -)

  • Kim, Sei-Yoon;Whang, Kum;Hong, Soon-Ki;Pyen, Jhin-Soo;Hu, Chul;Kim, Hun-Joo;Han, Young-Pyo;Lee, Myoung-Sup;Lee, Chong-Kook;Cho, Mee-Yon
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.5
    • /
    • pp.642-646
    • /
    • 2001
  • A 12-years-old female admitted to the hospital with the complaint of pain on the right upper chest area which persisted about 1 month prior to admission. $Caf{\acute{e}}$-au-lait spots of various size laying on a whole body and freckling on the axilla were found on physical examination. A huge mass was found on the plain chest X-ray and on chest MRI. The mass encroached thoracic spine, posterior rib, back muscles, and then into the neural canal and compressed thoracic spinal cord. On the 5th day of hospitalization, the patient complained tingling on the both legs and 2 days later, monoparesis on the right leg. Open thoracotomy and decompressive laminectomy was done to remove mass. Pathologic reports confirmed rhabdomyosarcoma, embryonal type.

  • PDF

A Case Report of Liposarcoma on the Neck in an Adult (성인에 발생한 경부 지방육종의 증례보고)

  • Joo, Jae Ok;Hong, Seong Hee;Lee, Jong Hoon;Kim, Dong Hoon
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.119-122
    • /
    • 2007
  • Purpose: Although liposarcoma is the second most common soft tissue sarcoma in adults, the incidence of liposarcoma of the head and neck is rare. There is only one reported case in Korea and moreover, only in adolescence. We report a case of liposarcoma on the neck in a 32-year-old male in adult. Methods: The patient had a slow growing, none tender mass on the posterior neck without lymphadenopathy, which has been present for 3 years and recurred twice during that time. MRI showed a 1.5 cm sized ovoid, well demarcated mass that was located in the subcutaneous layer of the posterior neck. Results: The mass was surgically removed. The resection margin was free of tumor on frozen biopsy and histopathologic examination indicated myxoid and round cell liposarcoma. The whole body F-18 FDG PET-CT applied on the fourteenth day postoperatively, revealed a moderate FDG-uptaking soft tissue lesion showing postoperative wound healing process on the posterior neck region and there was no distant metastasis. Conclusion: Liposarcoma is the second most common soft tissue sarcoma in adults. But, it rarely involves the head and neck region. Prognosis is principally dependent on histologic subtype and grade. Low grade liposarcoma such as well differentiated and myxoid liposarcoma tend to recur locally, rarely metastasize. On the other hand, high grade liposarcoma such as round cell and pleomorphic liposarcoma have higher rates of local recurrence and distant metastasis. Complete surgical excision provides the most effective means of treatment. Radiotherapy or chemotherapy can be used as an asjunctive treatment modality.

Effects of Low Grade Axial Loading on Discogenic Low Back Pain: A Case Report

  • Chang, Duncan;Boby, Arantxa;Madonna, James
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.9 no.4
    • /
    • pp.1683-1686
    • /
    • 2018
  • Low back pain (LBP) is the most common reason for seeking physical therapy (PT) care. Recent studies suggest that axial loading can have a positive impact on the intervertebral disc by improving its tensile strength. Further, whole body vibration (WBV) appears to improve spinal muscle relaxation. Therefore, this case study describes the use of axial loading using a mini-trampoline in a female with chronic LBP. This case report is a single subject design. This patient is a 29-year-old female with a six-month history of low back pain following a motor vehicle accident. MRI found herniated discs at L4 and L5, clinical tests were positive for pain in the L4 and L5 dermatome and myotome the slump test was positive for neural tension, and LBP was constant at 4-6/10 over the past four months. She received axial loading exercises using a mini-trampoline and performed six sessions that were, scheduled twice a week for three weeks. Her Oswestry Disability Index (ODI) score improved from 40% at the time of her first visit to 22% at her final visit. Pain measure on the Numeric Pain Rating Scale (NPRS) after the first treatment was 7/10, and her pain after the final treatment was 0/10. These changes in the pain scores are clinically significant and exceed the minimal clinically important difference (MCID). This patient had a significant improvement in her pain using the NPRS and the ODI. This case study suggests that axial loading may be an effective treatment for some individuals with discogenic chronic low back pain.

Production and Usage of Korean Human Information in KISTI (KISTI에 있어서 한국인 인체정보의 생산과 활용)

  • Lee, Sang-Ho;Lee, Seung-Bock
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.416-421
    • /
    • 2010
  • The KISTI (Korea Institute of Science and Technology Information) began to produce the Korean human information called Visible Korean and Digital Korean since 2000 because there was no human information in Korea which could represent the physical characteristics of Korean human body. The Visible Korean consists of CT, MR, sectioned and segmented images of Korean human body. We obtained the serially sectioned images by grinding the Korean cadaver in horizontal direction and segmented these images by outlining the inner organs of human. We have produced the sectioned images of Korean male whole body, male head, and female pelvis in2008. The segmentation and 3D reconstruction of these images are now in proceeding. The Digital Korean consists of CT images of about 100 Korean cadavers. These CT images were segmented by individual bone, reconstructed to produce the 3D bone models and the skin surface model was also added. The mechanical properties of individual bones were obtained by measuring the property of individual bone sample. We have distributed these Korean human informations to users in domestic and abroad. About 70 institutes in domestic, and 20 institutes in abroad have used our data in research use and nearly 160 proceedings and articles were published since 2001. We think these human informations have a role of medical information infrastructure that could be used in the field of medical education, biomechanics, virtual reality etc.

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF