• Title/Summary/Keyword: Whole body imaging

Search Result 166, Processing Time 0.024 seconds

Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

Effects of Pinacidil, a Potassium-Channel Opener, on Biodistribution of Thallium-201 in Tumor-Bearing Mice ($K^+$ 통로개방제 Pinacidil이 종양이식 생쥐에서 Tl-201의 체내분포에 미치는 영향)

  • Lee, Jae-Tae;Chun, Kyung-Ah;Lee, Sang-Woo;Kang, Do-Young;Ahn, Byeong-Cheol;Jun, Soo-Han;Lee, Kyu-Bo;Ha, Jeoung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.303-311
    • /
    • 2000
  • Purpose: Thallium behaves similarly to potassium in vivo. Potassium channel opener (K-opener) opens ATP-sensitive $K^+$-channel located at cell membrane, resulting in potassium efflux from cytosol. We have previously reported that K-opener can alter biokinetics of Tl-201 in cultured cells and in vivo. Malignant tumor cells have high Na-K ATPase activity due to increased metabolic activities and dedifferentiation, and differential delineation of malignant tumor can be possible with Tl-201 imaging. K-opener may affect tumoral uptake of Tl-201 in vivo. To investigate the effects of pinacidil (one of the potent K-openers) on the localization of the tumor with Tl-201 chloride, we evaluated the changes in biodistribution of Tl-201 with pinacidil treatment in tumor-bearing mice. Materials and Methods: Baltic mice received subcutaneous implantation of murine breast cancer cells in the thigh and were used for biodistribution study 3 weeks later. $100{\mu}g$ of pinacidil dissolved in $200{\mu}l$ DMSO/PBS solution was injected intravenously via tail vein at 10 min after 185 KBq ($5{\mu}Ci$) Tl-201 injection. Percentage organ uptake and whole body retention ratio of Tl-201 were measured at various periods after injection, and values were compared between control and pinacidil-treated mice. Results: Pinacidil treatment resulted in mild decrease in blood levels of Tl-201, but renal uptakes were markedly decreased at 30-min, 1- and 2-hour, compared to control group. Hepatic, intestinal and muscular uptake were not different. Absolute percentage uptake and tumor to blood ratios of Tl-201 were lower in pinacidil treated mice than in the control group at all time points measured. Whole body retention ratio of Tl-201 was lower in pinacidil treated mice ($58{\pm}4%$ ), than in the control group ($67{\pm}3%$) at 24 hours after with injection of $100{\mu}g$ pinacidil. Conclusion: K-opener did not enhance, but rather decreased absolute tumoral uptake and tumor-to-blood ratios of Tl-201. Decreased whole body retention ratio and renal uptake were observed with pinacidil treatment in tumor-bearing mice.

  • PDF

Assessing Cerebral Oxygen Metabolism Changes in Patients With Preeclampsia Using Voxel-Based Morphometry of Oxygen Extraction Fraction Maps in Magnetic Resonance Imaging

  • Qihao Zhang;Chaofan Sui;Junghun Cho;Linfeng Yang;Tao Chen;Bin Guo;Kelly McCabe Gillen;Jing Li;Lingfei Guo;Yi Wang
    • Korean Journal of Radiology
    • /
    • v.24 no.4
    • /
    • pp.324-337
    • /
    • 2023
  • Objective: The objective of this study was to analyze the different brain oxygen metabolism statuses in preeclampsia using magnetic resonance imaging and investigate the factors that affect cerebral oxygen metabolism in preeclampsia. Materials and Methods: Forty-nine women with preeclampsia (mean age 32.4 years; range, 18-44 years), 22 pregnant healthy controls (PHCs) (mean age 30.7 years; range, 23-40 years), and 40 non-pregnant healthy controls (NPHCs) (mean age 32.5 years; range, 20-42 years) were included in this study. Brain oxygen extraction fraction (OEF) values were computed using quantitative susceptibility mapping (QSM) plus quantitative blood oxygen level-dependent magnitude-based OEF mapping (QSM + quantitative blood oxygen level-dependent imaging or QQ) obtained with a 1.5-T scanner. Voxel-based morphometry (VBM) was used to investigate the differences in OEF values in the brain regions among the groups. Results: Among the three groups, the average OEF values were significantly different in multiple brain areas, including the parahippocampus, multiple gyri of the frontal lobe, calcarine, cuneus, and precuneus (all P-values were less than 0.05, after correcting for multiple comparisons). The average OEF values of the preeclampsia group were higher than those of the PHC and NPHC groups. The bilateral superior frontal gyrus/bilateral medial superior frontal gyrus had the largest size of the aforementioned brain regions, and the OEF values in this area were 24.2 ± 4.6, 21.3 ± 2.4, and 20.6 ± 2.8 in the preeclampsia, PHC, and NPHC groups, respectively. In addition, the OEF values showed no significant differences between NPHC and PHC. Correlation analysis revealed that the OEF values of some brain regions (mainly involving the frontal, occipital, and temporal gyrus) were positively correlated with age, gestational week, body mass index, and mean blood pressure in the preeclampsia group (r = 0.361-0.812). Conclusion: Using whole-brain VBM analysis, we found that patients with preeclampsia had higher OEF values than controls.

FOREIGN BODIES IN MAXILLOFACIAL REGION (구강악안면부위에서 발견된 이물질)

  • Kim, Il-Kyu;Sihn, Joo-Ho;Oh, Sung-Seop;Choi, Jin-Ho;Oh, Nam-Sik;Rim, Young-Il;Kim, Wang-Sik
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.266-270
    • /
    • 2001
  • Foreign bodies in the maxillofacial area are not commonly seen. If occurred, the immediate removal of foreign bodies is recommended to avoid further complications. The most important thing is a exact localization of foreign bodies using X-rays such as plain radiography, computed tomography, magnetic resonance imaging and ultrasound before treatment. During removal of foreign bodies, tissue should be dissected carefully and complete exploration of the whole wound required.

  • PDF

Osteoporosis prediction from the mandible using cone-beam computed tomography

  • Barngkgei, Imad;Haffar, Iyad Al;Khattab, Razan
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.263-271
    • /
    • 2014
  • Purpose: This study aimed to evaluate the use of dental cone-beam computed tomography (CBCT) in the diagnosis of osteoporosis among menopausal and postmenopausal women by using only a CBCT viewer program. Materials and Methods: Thirty-eight menopausal and postmenopausal women who underwent dual-energy X-ray absorptiometry (DXA) examination for hip and lumbar vertebrae were scanned using CBCT (field of view: $13cm{\times}15cm;$ voxel size: 0.25 mm). Slices from the body of the mandible as well as the ramus were selected and some CBCT-derived variables, such as radiographic density (RD) as gray values, were calculated as gray values. Pearson's correlation, one-way analysis of variance (ANOVA), and accuracy (sensitivity and specificity) evaluation based on linear and logistic regression were performed to choose the variable that best correlated with the lumbar and femoral neck T-scores. Results: RD of the whole bone area of the mandible was the variable that best correlated with and predicted both the femoral neck and the lumbar vertebrae T-scores; further, Pearson's correlation coefficients were 0.5/0.6 (p value=0.037/0.009). The sensitivity, specificity, and accuracy based on the logistic regression were 50%, 88.9%, and 78.4%, respectively, for the femoral neck, and 46.2%, 91.3%, and 75%, respectively, for the lumbar vertebrae. Conclusion: Lumbar vertebrae and femoral neck osteoporosis can be predicted with high accuracy from the RD value of the body of the mandible by using a CBCT viewer program.

A Kinematical Analysis of Side Kick Motion in Taekwondo (태권도 옆차기 동작의 운동학적 분석)

  • Park, Kwang-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.49-63
    • /
    • 2003
  • For this study, four male university Taekwondo players were randomly chosen, between the weight categories of 60Kg and 80Kg. Their side kicks (yeop chagi), which are part of foot techniques, were kinematically analyzed in terms of the time, angle, and angular velocity factors involved with the kicks through the three-dimensional imaging. The results of the analysis are as fellows. 1. Time factor The first phase(preparation) was 0.48sec on average, accounting for 60% of the entire time spent; the second phase(the minimum angle of the knee joint) was 0.21sec on average, taking up 26% of the whole time spent; and the third phase(hitting) was 0.11sec on average, representing 14% of the entire time spent. 2. Angle factor In the first phase(preparation), rotating their bodies along the long axis, the players bended their hip and knee joints a lot, by moving fast in the vertical and horizontal directions, in the second phase(the minimum angle of the knee joint), the players continued to extend their bodies along the vertical axis, while pronating their lower legs and bending their hip and knee joints a lot to reduce the radius of gyration, and in the third phase(hitting), they extended their knee joints greatly so that the angle movements of their lower bodies shifted to circle movements. 3. Angular velocity factor In the first phase(preparation), the angular velocity of the hip and knee joints increased. while moving horizontally and rotating the body along the long axis; in the second phase(the minimum angle of the knee joint), the angular velocity increased by bending the hip and knee joints fast to reduce the rotation radios; and in the third phase(hitting), the angular velocity was found to have increased, by rotating the body along the long axis to increase the angular velocity and shifting the angular momentum of the pronated knee joint to the circular momentum.

Verification of the HWAW (Harmonic Wavelet Analysis of Waves) Method Using Multi Layered Model Testing Site (실대형 모형부지를 이용한 HWAW(Harmonic Wavelet Analysis of Waves) 기법의 검증)

  • Kim, Jong-Tae;Park, Hyong-Choon;Kim, Dong-Soo;Bang, Eun-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.33-46
    • /
    • 2007
  • HWAW (Harmonic Wavelet Analysis of Wave) method, which is non-destructive method using body and surface waves, has the advantages of obtaining 2D subsurface imaging because it uses a short receiver spacing to obtain the $V_s$ profile of whole depth. Even though the reliability of HWAW method has already been verified by using the numerical simulation in the various layered models, it is very difficult to evaluate the reliability of HWAW in the field because the exact $V_s$ values of the experimental site are unknown. In this study, a model testing site where the material properties and layer information could be controlled was constructed to verify the reliability of HWAW method. The detailed geometry of the testing site was strictly measured by surveying, and 140 vertical and horizontal geophones were established at the boundary of each layer to evaluate the dynamic material properties. Using the interval travel times between the upper and lower geophones, the body wave velocities of each layer were 2 dimensionally obtained as reference data, and comparative study using HWAW method was performed. By comparing 2D Vs profile obtained by HWAW method to the reference data, the reliability of HWAW method was verified.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Use of $^{18}F$-FDG PET/CT in Second Primary Cancer (이차성 원발암에서의 $^{18}F$-FDG PET/CT의 이용)

  • Choi, Joon-Young;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.185-193
    • /
    • 2007
  • This review focuses on the use of $^{18}F-FDG$ PET/CT to evaluate second primary cancers. The emergence of a second primary cancer is an important prognostic factor in cancer patients. The early detection of a second primary cancer and the appropriate treatment are essential for reducing the morbidity and mortality associated with these tumors. Integrated $^{18}F-FDG$ PET/CT, which can provide both the metabolic and anatomic information of a cancer, has been shown to have a better accuracy in oncology than either CT or conventional PET. The whole body coverage and high sensitivity of $^{18}F-FDG$ PET/CT along with its ability to provide both metabolic and anatomic information of a cancer make it suitable for evaluating a second primary cancer in oncology. Whole body $^{18}F-FDG$ PET/CT is useful for screening second primary cancers with a high sensitivity and good positive predictive value. In order to rule out the presence of a second primary cancer or an unexpected metastasis, further diagnostic work-up is essential when abnormal findings indicative of a second primary cancer are found on the PET/CT images. PET/CT is better in detecting a second primary tumor than conventional PET.

Gamma Ray Detection Processing in PET/CT scanner (PET/CT 장치의 감마선 검출과정)

  • Park, Soung-Ock;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • The PET/CT scanner is an evolution in image technology. The two modalities are complementary with CT and PET images. The PET scan images are well known as low resolution anatomic landmak, but such problems may help with interpretation detailed anatomic framework such as that provided by CT scan. PET/CT offers some advantages-improved lesion localization and identification, more accurate tumor staging. etc. Conventional PET employs tranmission scan require around 4 min./bed position and 30 min. for whole body scan. But PET/CT scanner can reduced by 50% in whole body scan. Especially nowadays PET scanner LSO scintillator-based from BGO without septa and operate in 3-D acquisition mode with multidetectors CT. PET/CT scanner fusion problems solved through hardware rather than software. Such device provides with the capability to acquire accurately aligned anatomic and functional images from single scan. It is very important to effective detection from gamma ray source in PETdetector. And can be offer high quality diagnostic images. So we have study about detection processing of PET detector and high quality imaging process.

  • PDF