• Title/Summary/Keyword: Whole body imaging

Search Result 166, Processing Time 0.03 seconds

Comprehensive Updates in the Role of Imaging for Multiple Myeloma Management Based on Recent International Guidelines

  • Koeun Lee;Kyung Won Kim;Yousun Ko;Ho Young Park;Eun Jin Chae;Jeong Hyun Lee;Jin-Sook Ryu;Hye Won Chung
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1497-1513
    • /
    • 2021
  • The diagnostic and treatment methods of multiple myeloma (MM) have been rapidly evolving owing to advances in imaging techniques and new therapeutic agents. Imaging has begun to play an important role in the management of MM, and international guidelines are frequently updated. Since the publication of 2015 International Myeloma Working Group (IMWG) criteria for the diagnosis of MM, whole-body magnetic resonance imaging (MRI) or low-dose whole-body computed tomography (CT) and 18F-fluorodeoxyglucose positron emission tomography/CT have entered the mainstream as diagnostic and treatment response assessment tools. The 2019 IMWG guidelines also provide imaging recommendations for various clinical settings. Accordingly, radiologists have become a key component of MM management. In this review, we provide an overview of updates in the MM field with an emphasis on imaging modalities.

Localized MR Imaging Technique by Using Locally-Linear Gradient Field (부분적 경사자계를 이용한 국부자기공명 영상촬영기법)

  • Yang, Y.J.;Lee, J.K.;Jeong, S.T.;Cho, Z.H.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.247-249
    • /
    • 1995
  • A new localized imaging technique of reduced imaging time using a locally-linear gradient is proposed. Since most fast MR imaging methods need the whole k-space data corresponding to the whole imaging area, there are limitations in reducing the minimum imaging time. The imaging method proposed in this paper uses a specially-made gradient coil generating a local ramp-shape field and uniform field outside of the imaging area. Conventional imaging sequences can be used without any RF/gradient pulse sequence modifications. The proposed localized imaging technique has been implemented on a 2.0 Tesla whole-body system at KAIST and the imaging results show the utility of the proposed technique.

  • PDF

Research about Hyperspectral Imaging System for Pre-Clinical testing of Small Animal (소형동물 전임상실험을 위한 하이퍼스펙트럼 영상장비 연구)

  • Lee, kyeong-Hee;Choi, Young-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2208-2213
    • /
    • 2007
  • In this study we have developed a hyperspectrum imaging system for highly sensitive and effective imaging analysis. An optical setup was designed using acoustic optical tunable filter (AOTF) for high sensitive hyperspectrum imaging. Light emitted by mercury lamp gets split in to diffracted and undiffracted beams while passing though AOTF. GFP transfected HEK-293 cell line was used as a model for in vitro imaging analysis. Cells were first, analyzed by fluorescence microscope followed by flow cytometric analysis. Flow cytometric analysis showed 66.31% transfection yield in GFP transfected HEK-293 cells. Various images of GFP transfected HEK-293 cell were grabbed by collecting the diffracted light using a CCD over a dynamic range of frequency of 129-171 MHz with an interval of 3 MHz. Subsequently, for in vivo image analysis of GFP transfected cells in mouse, a whole-body-imaging system was constructed. The blue light of 488 nm wavelength was obtained from a Xenon arc lamp using an appropriate filter and transmitted through an optical cable to a ring illuminator. To check the efficacy of the newly developed whole-body-imaging system, a comparative imaging analysis was performed on a normal mouse in presence and absence of Xenon arc irradiation. The developed hyperspectrum imaging analysis with AOTF showed the highest intensity of green fluorescent protein at 153 MHz of frequency and 494 nm of wavelength. However, the fluorescence intensity remained same as that of the background below 138 MHz (475 nm) and above 162 MHz (532 nm). The mouse images captured using the constructed whole-body-imaging system appeared monochromatic in absence of Xenon arc irradiation and blue when irradiated with Xenon arc lamp. Nevertheless, in either case mouse images appeared clearly.

Body Height Effect on Brain Volumes in Youth Decreases in Old Age in Koreans

  • Koh, In-Song
    • Interdisciplinary Bio Central
    • /
    • v.3 no.3
    • /
    • pp.11.1-11.5
    • /
    • 2011
  • The MRI (magnetic resonance imaging) volumetric analysis of the brain was performed in 59 healthy elderly Koreans (aged 62-76 years; 34 male, 25 female) to investigate whether the previously reported significant correlations between body height and brain volumes in the young aged Koreans (20's) still exist in the old aged Koreans (60's and 70's). Unlike previously reported significant correlations in the young aged Koreans, neither the correlation between whole brain volume and body height in male nor the correlation between cerebellar volume and body height in female show any significance in the old aged Koreans. The significant correlation between body height and whole brain volume was still observed when both male and female data were combined (r=0.27, P<0.05), but the correlation coef-ficient and the level of significance markedly decreased from those of previously reported Korean youth data (r=0.67, P<0.01). Simple linear regression analysis shows decrease of explanatory power of height (measured in $r^2$) from 44% in the youth group to 7% in the old age group on the variance of whole brain volume. Multiple linear regression analysis shows that age and sex, rather than height, are major explanatory variables for whole brain volume in the old aged Koreans. The loss of correlations in the aged group is suspected to be mainly due to age related brain volume changes.

In Vivo Non Invasive Molecular Imaging for Immune Cell Tracking in Small Animals

  • Youn, Hyewon;Hong, Kee-Jong
    • IMMUNE NETWORK
    • /
    • v.12 no.6
    • /
    • pp.223-229
    • /
    • 2012
  • Clinical and preclinical in vivo immune cell imaging approaches have been used to study immune cell proliferation, apoptosis and interaction at the microscopic (intra-vital imaging) and macroscopic (whole-body imaging) level by use of ex vivo or in vivo labeling method. A series of imaging techniques ranging from non-radiation based techniques such as optical imaging, MRI, and ultrasound to radiation based CT/nuclear imaging can be used for in vivo immune cell tracking. These imaging modalities highlight the intrinsic behavior of different immune cell populations in physiological context. Fluorescent, radioactive or paramagnetic probes can be used in direct labeling protocols to monitor the specific cell population. Reporter genes can also be used for genetic, indirect labeling protocols to track the fate of a given cell subpopulation in vivo. In this review, we summarized several methods dealing with dendritic cell, macrophage, and T lymphocyte specifically labeled for different macroscopic whole-body imaging techniques both for the study of their physiological function and in the context of immunotherapy to exploit imaging-derived information and immune-based treatments.

Preliminaly Result of Whole-body Slotted Tube Resonator for 3.0T MRI

  • Kim, Kyoung-Nam;Park, Bu-Sick;Chung, Sung-Taek
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.151-151
    • /
    • 2001
  • Purpose: 3.0 Tesla whole-body resonator provides a potential to have significant increase in imag quality and resolution in high resolution application such as cardiac, spine and extremit imaging. The aim of this study is to design an optimized 3.0T whole-body coil to produce high sensitivity and quality using slotted tube resonator.

  • PDF

  • Willinek, Winfried A.
    • Proceedings of the KSMRM Conference
    • /
    • 2004.09a
    • /
    • pp.87-87
    • /
    • 2004
  • PDF

Interleaved Spiral Scan Imaging (Interleaved 나선 주사 영상)

  • Ahn, C.B.;Kim, H.J.;Shin, J.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.98-99
    • /
    • 1998
  • In this paper, an interleaved spiral scan imaging is investigated for an ultra fast MR imaging. The interleaved spiral technique has relative advantage over single shot spiral imaging with improved resolution and less inhomogeneity-related artifact. An improved reconstruction algorithm is devised with DC-offset correction. Some preliminary experimental results are shown at 1.0 Tesla and 3.0 Tesla whole body MRI system.

  • PDF

Generalized Lymphangiomatosis: A Case Report (전신성 림프관종증: 증례 보고)

  • Cha, Jang-Gyu;Park, Jai-Soung;Paik, Sang-Hyun;Kim, Hee-Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.190-194
    • /
    • 2009
  • Generalized lymphangiomatosis is a rare congenital malformation of the lymphatics. CT and MR scan have been used to evaluate lymphangiomas, which appear as large multicystic fluid-filled masses. CT and MR Imaging findings are often helpful in distinguishing lymphangiomas from various vascular disorders. We report the findings of CT, MRI and bone scan in a patient with generalized cystic lymphangiomatosis. Whole body 3.0-T MR scan using STIR sequence with a larger FOV could detect the additional lesions that were not seen at other imaging modalities. We believe that whole body 3.0 T MR imaging is a good modality to evaluate the extent of the disease and following up the patients with the generalized cystic lymphangiomatosis.

  • PDF