• Title/Summary/Keyword: Wet test

Search Result 790, Processing Time 0.024 seconds

The Frost and Defrost Performances of Fin-and-Tube Heat Exchangers with Different Surface Treatment Characteristics (서로 다른 표면특성을 갖는 핀-관 열교환기의 착상과 제상 성능평가)

  • 최봉준;황준현;신종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.781-785
    • /
    • 2002
  • The effects of different surfaces on dry and wet frosting test were experimentally investigated. The results of experiment were compared by the performance evaluation coefficient (PEC). Results showed that the air-side pressure drop of lacquer coated evaporator increased by 5% as compared to the plasma treated one. It was also found that the Plasma coated evaporator is lower than lacquer coated one in the PEC ratio.

Evaluation of Corrosion Protective System for Reinforced Concrete Structures Constructed With Sea Sand (해사 혼입된 콘크리트 구조물의 부식도 평가)

  • 김웅희;홍기섭;오승모;장지원;최응규;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.203-209
    • /
    • 1997
  • An experimental study to evaluate to evaluate corrosion protection systems was undertaken with 44 reinforced concrete slab specimens subjected to cyclic wet and dry saltwater exposure. Corrosion measurements included monitoring macrocell corrosion currents, which are genrerally accecpted in United States practice. Test results indicate that specimens containing 2 kg/$\textrm{m}^3$ of NaCl and exposed to wet(outdoor) and dry(indoor) conditions but not to saltwater show very low values of corrosion measurements regardless applying any corrosion protective systems. Corrosion currents of the specimens exposed at 10 percent of NaCl were higher than that of the specimen exposed at 5 percent of NaCl, so the density of the salt water had an influential effect on the test. For the specimens with water repellent membrane currents kept relatively low numerical values, but test specimens with surface corrosion inhibitor protective system showed high values of corrosion current. It would be expected that evaluation of the corrosion protective systems need long-term measurement.

  • PDF

Mobility Evaluation of Popular Firefighting Protective Gloves in Domestic and Foreign Countries -Don-Doff Test, Dexterity Test, and Torque Test- (국내외 보급형 소방용 보호장갑의 동작성 평가 -착탈 시험, 기민성 시험, 회전력 시험을 중심으로-)

  • Kim, Dami;Lee, Inseong;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.5
    • /
    • pp.921-935
    • /
    • 2016
  • This research analyzed the manual performance of firefighting protective gloves on global markets in order to suggest an evaluation method for firefighting protective gloves wearing comfort. We collected 13 types of firefighting gloves from domestic and international markets (7 types from Korea, 3 types form Europe, 2 types from the U.S and 1 type from Japan). We set the Don-Doff test as a basal requirement for moving toward to further manual performance tests that consist of: ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. All gloves were evaluated in dry and wet conditions, we included eight current male firefighters ($43.4{\pm}7.0yr$ in age, $173.1{\pm}4.4cm$ in height, $79.9{\pm}9.2kg$ in body mass) for the tests. Four gloves (1 Korea, 1 U.S, 1 Germany, and 1 Japan) out of thirteen firefighting gloves passed the Don-Doff test and had great subject preferences. There was no significant difference between dry and wet conditions on the ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. However, Japanese gloves had the greatest score and showed 3-4 times faster completion time on the ASTM dexterity test (p<.05), 1.2-1.5 times faster on the Minnesota dexterity test (p<.05), as fast as the bare hand on Bennett hand tool test (p<.05), and greater performance on the ASTM torque test compared to bare hand. In conclusion, Don-Doff test in wet conditions should be the first step for a mobility evaluation of domestic firefighting protective gloves; subsequently, a comprehensive test assorting ASTM, Minnesota, and Bennett test should be developed as a second step. The current ASTM torque test can be adopted as a third step. This three-step-method for evaluating firefighting protective glove mobility can be expected to expand into surveys of other safety gloves in Korea.

Experimental Performance Characteristics of Crumb Rubber-Modified(CRM) Asphalt Concrete (폐타이어활용 아스팔트 콘크리트의 실험적 공용특성)

  • Kim, Nak-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.2 s.9
    • /
    • pp.89-97
    • /
    • 2003
  • Indirect tensile strength(IDT) test and resilient modulus(Mr) test were performed to evaluate experimental performance characteristics for the conventional and crumb rubber-modified(CRM) asphalt concrete using dry and wet processes asphalt. The IDT test was conducted under three temperatures(5, 10, 20$^{\circ}C$). According to the test results, it was shown that indirect tensile strength of CRM asphalt concrete was lower than that of the conventional one. However, toughness and maximum vortical strain of the CRM asphalt concrete were higher than those of the conventional one. The results of Mr test were presented that Mr of CRM asphalt concrete was higher than that of the conventional one. In addition, it was revealed that the overall laboratory performance characteristics of the wet-processed CRM asphalt concrete was better than those of the dry-processed one.

Experimental Study on Capacity Variation of Paving Materials with TiO2 in Wet Condition (광촉매 이산화티타늄(TiO2)을 혼합한 도로 포장재의 습윤 조건에서의 성능 변화에 관한 실험적 연구)

  • Seo, Dawa;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.5
    • /
    • pp.49-55
    • /
    • 2016
  • This study aims to present the practical Nitrogen monoxide (NO) removal capacity of cement mortar with Titanium dioxide ($TiO_2$) which is one of the paving materials by considering the environment of pavement in urban areas. NO removal capacity test under designated conditions of humidity of inflow gas and the test with variation of the degree of saturation of specimen were conducted. In the test for humidity, dry specimen is subject to the test and NO removal ratio was observed. Humidity-NO removal ratio curve is a log normal distribution in shape, and the maximum NO removal ratio appears at specific humidity. NO removal capacity test relying on the degree of saturation was carried out with wet specimen to reflect the unsaturated pavement by rainfall and domestic sewage. Wet specimen presents less NO removal capacity than dry specimen and the recovering evolution of NO removal capacity follows evaporation. Moreover, $TiO_2$ under the specific depth of specimen hardly contributes to NO removal capacity.

Estimation of Chloride Corrosion Threshold Value in Concrete by Using Electrochemical and Cyclic Wet and Dry Seawater Method (전기화학적 및 해수 건습반복 방법에 의한 콘크리트 내의 임계 염화물량 평가)

  • Bae Su Ho;Lee Kwang Myong;Chung Young Soo;Kim Jee Sang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.245-248
    • /
    • 2005
  • It should be noted that the critical chloride threshold level is not considered to be a unique value for all conditions. This value is dependent on concrete mixture proportions, cement type and constituents, presence of admixtures, environmental factors, steel reinforcement surface. conditions, and other factors. In this study, the accelerated corrosion test for reinforcing steel was conducted by electrochemical and cyclic wet and dry seawater method, respectively and during the test, corrosion monitoring by half cell potential method was carried out to estimate the chloride corrosion threshold value when corrosion for reinforcing steel in concrete was perceived. For this purpose, lollypop and right hexahedron test specimens were made for 31.4$\%$, 41.5$\%$ and 49.7$\%$ of w/c, respectively and then the accelerated corrosion test for reinforcing steel was executed. It was observed from the test that the time to initiation of corrosion was found to be different with water-cement ratio and accelerated corrosion test method, respectively and the chloride corrosion threshold value was found to range from 0.91 to 1.43 kg/$m^{3}$.

  • PDF

Identification, Characteristics, and Growth Inhibition of the Strain Isolated from Spoiled Wet Noodle

  • Kim, Hyeong-Hyoi;Jeong, Eun-Jeong;Jeong, Do-Yeong;Kim, Yong-Suk;Shin, Dong-Hwa
    • Food Science and Biotechnology
    • /
    • v.14 no.4
    • /
    • pp.461-465
    • /
    • 2005
  • To determine the cause of wet noodle spoilage, microorganisms isolated from wet noodles were identified and characterized. In addition, the growth inhibitory effects of organic acid mixture (OA: lactic acid 27.8%, acetic acid 12.0%, succinic acid 1.0%) and sodium dehydroacetate (SD) on the isolated strain were estimated in nutrient broth medium. The isolated strain was Gram-positive, rod shaped, motile, and spore forming. Based on physiological characteristics and the API 50 CHB-kit test results for the assimilation of 49 carbohydrates, the isolated strain was identified as Bacillus amyloliquefaciens (92.6%), which is able to degrade starch. Decimal reduction times (D-values) at 100, 105, and $110^{\circ}C$ for spores of B. amyloliquefaciens were 8.5, 5.1, and 2.5 min, respectively, and the z-value was $12.8^{\circ}C$. We estimated that B. amylo-liquefaciens isolated from spoiled wet noodles was a thermophilic species having high heat-resistance. Viable cell numbers in wet noodles and broth medium inoculated with B. amyloliquefaciens were decreased by 2-4 log cycles by combined treatment with 0.03 or 0.05% OA and 0.3% SD. These results revealed that OA combined with SD could be used as a potential agent to inhibit B. amyloliquefaciens in wet noodles.

Wet Damping Estimation of the Segmented Hull Model using the Random Decrement Technique (랜덤 감쇠기법을 이용한 분할모형의 접수 감쇠계수 추정)

  • Kim, Yooil;Park, Sung-Gun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.4
    • /
    • pp.217-223
    • /
    • 2013
  • This paper presents the wet damping estimation of the segmented hull model using the random decrement technique together with the continuous wavelet transform. The tested 16 sea states are grouped together based on the speed of the ship in order to figure out the possible influence of the ship speed on the damping ratio. The measured time histories of vertical bending moment for each tested sea state were processed with random decrement technique to derive the free decay signal, from which the damping ratios are estimated. Also, the autocorrelation functions of the filtered signal were calculated and comparison was made with the free decay signal obtained from the random decrement technique. Then the wet damping ratios for each sea state group, as well as precise wet natural frequencies, are estimated by using continuous wavelet transform. It turned out that the wet natural frequencies derived from the measured signal did not show any significant discrepancy compared with those obtained by wet hammering test, whereas the damping ratio did. It was considered that the discrepancy of the damping ratio between in calm and moving water may be attributed to the viscous effects caused by dramatically different flow pattern and relative velocity between the vibrating structure and surrounding fluid particles.

A Study on Low Residue Flux for Improving Flip Chip Non-wet and Reliability (Flip Chip Non-wet 개선 및 신뢰성 향상을 위한 Low Residue Flux 구현 방안 연구)

  • Lee, Hyunsuk;Kim, Minseok;Kim, Taehoon;Moon, Kiill
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.2
    • /
    • pp.45-50
    • /
    • 2021
  • As the difficulty of flip chip products increases, there is a growing interest in the material of flux, which is safe from the solder wetting and reliability. In the case of no clean flux, there is merit in terms of process efficiency because there is no cleaning process. But Cu migration and delamination can be occurred if the residue remains after the reflow process. In this study, major element materials, solvent and activator, are changed and confirmed effect of non-wet and reliability in the package environment. Stability of materials were secured through storage stability evaluation, and we found out non-wet zero materials through the application of two types of solvent and activator with different boiling point and the increase of activator content. After reliability test, no delamination was found in the plane analysis, which secured the final composition of low residue flux.