• 제목/요약/키워드: Wet surface

검색결과 1,217건 처리시간 0.026초

새로운 건성 및 습성 침착 채취기의 개발 (Development of the Novel Dry and Wet Deposition Collector)

  • 이병규;이채복
    • 한국대기환경학회지
    • /
    • 제16권6호
    • /
    • pp.675-684
    • /
    • 2000
  • A novel dry and wet deposition collector, which can overcome the several problems such as water evaporation cartridge cracks and high costs founded in the previous collector systems, has been constructed. ENVI-18 SPE adsorption cartridge has been used to measure atmospheric deposition of polycylic aromatic hydrocarbons (PAHs). A surrogate surface, consisted of water and methanol, was filled in the dry deposition funnel to simulate dry deposition onto water surface. A water supply system in order to compensat evaporation of the surrogate surface was used and it was consisted of a piston pump, a tubing pump, a overflow tube and a chamber system. A novel water vaporizing system to supply water onto the wet SPE cartridge system with a constant flow rate was developed. The novel water vaporizing system, consisted of a vacuum pump, a water supply reserviour and tube and a mini space heater, could prevent the PAHs adsorption cartridge cracks occurred in the previous collector and effectively adsorb PAHs. The novel dry and wet deposition collector showed a good adsorption, desorption, and recovery rates of PAHs. By reducing the number of pumps used and employing polypyopylene (PP) instead of teflon as a material of collection funnel, the total construction costs were much reduced as compared with the previous dry and wet deposition collectors.

  • PDF

정점 기반 접착력 모델을 활용한 젖은 옷감 애니메이션 (Wet cloth animation with vertex based adhesion force model)

  • 박민주;변혜원
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제25권1호
    • /
    • pp.1-11
    • /
    • 2019
  • 책상 위에 놓인 젖은 옷감을 움직이기 위해서는 마른 옷감을 움직일 때와 비교하여 더 많은 힘이 필요하게 되는데, 그 이유는 젖은 옷감과 책상의 표면 사이의 위치한 유체가 접착력을 만들어내기 때문이다. 본 논문은 젖은 옷감이 물체의 표면에 달라 붙는 현상에 집중하여 젖은 옷감을 표현한다. 접착력을 계산하기 위해서 우리는 섬유 관련 연구 분야에서 실제 실험을 기반으로 모델링한 접착력 모델을 활용하였고, 기존 연구와 다르게 젖은 옷감이 물체와 닿아있는 부분에서도 자연스럽게 주름이 만들어지는 모습을 표현한다. 젖은 옷감이 물체에 달라 붙는 현상과 더불어 젖은 옷감끼리도 서로에게 달라 붙는 현상을 표현함으로써 보다 실제의 젖은 옷감과 유사한 결과를 보인다.

Investigation of Floor Surface Finishes for Optimal Slip Resistance Performance

  • Kim, In-Ju
    • Safety and Health at Work
    • /
    • 제9권1호
    • /
    • pp.17-24
    • /
    • 2018
  • Background: Increasing the slip resistance of floor surfaces would be desirable, but there is a lack of evidence on whether traction properties are linearly correlated with the topographic features of the floor surfaces or what scales of surface roughness are required to effectively control the slipperiness of floors. Objective: This study expands on earlier findings on the effects of floor surface finishes against slip resistance performance and determines the operative ranges of floor surface roughness for optimal slip resistance controls under different risk levels of walking environments. Methods: Dynamic friction tests were conducted among three shoes and nine floor specimens under wet and oily environments and compared with a soapy environment. Results: The test results showed the significant effects of floor surface roughness on slip resistance performance against all the lubricated environments. Compared with the floor-type effect, the shoe-type effect on slip resistance performance was insignificant against the highly polluted environments. The study outcomes also indicated that the oily environment required rougher surface finishes than the wet and soapy ones in their lower boundary ranges of floor surface roughness. Conclusion: The results of this study with previous findings confirm that floor surface finishes require different levels of surface coarseness for different types of environmental conditions to effectively manage slippery walking environments. Collected data on operative ranges of floor surface roughness seem to be a valuable tool to develop practical design information and standards for floor surface finishes to efficiently prevent pedestrian fall incidents.

식각액에 따른 용융실리카의 레이저 습식 식각가공 (Laser Induced Wet Etching of Fused Silica according to Etchant)

  • 이종호;이종길;전병희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.245-249
    • /
    • 2004
  • Transparent materials such as fused silica are important materials in optical and optoelectronics field because of its outstanding properties, such as transparency in a wide wavelength range, strong damage resistance for laser irradiation, and high thermal and chemical stability. However, these properties make it difficult to micromachine silica in micro-sized quantities. In this study, we fabricated a micro patterns on the surface of fused silica plate using laser induced wet etching. KrF excimer laser was used as a light source. There were no burrs and micro cracks on the etched surface of fused silica and the flatness of the etched surface was fairly good. We investigated the influence of etchant upon the etch rate and quality in laser induced wet etching. Pyrene-acetone, toluene, and pyrene-toluene solution were used as etchant. In the side of etch rate, toluene and pyrene-toluene solution were better than pyrene-acetone solution.

  • PDF

건습식 혼합공정을 이용한 유연소재 상 전자파 차폐용 다층막 코팅 (Multilayer Coatings on Flexible substrate for Electromagnetic Shielding by Using Dry/Wet Hybrid Processes)

  • 이훈성;이명훈
    • 한국표면공학회지
    • /
    • 제50권5호
    • /
    • pp.373-379
    • /
    • 2017
  • Dry processes like evaporation and sputtering in vacuum chamber are difficult to make a uniform, large area and high quality film on thin PET substrate because of PET degradation and bad adhesion. On the other hand, wet processes like electro or electroless plating have complex processes and require high environmental cost. In this study, we successfully prepared $2{\mu}m$ Zn/Cu/Ni multilayers coated on $12{\mu}m$ polyethylene terephthalate (PET) substrate by using dry-wet mixing processes. Their surface electric resistances were evaluated around $0.2{\Omega}$ by using 4 probe measurements. Furthermore, their corrosion resistance also evaluated by natural potential test and compared with other wet, dry and mixing process samples.

플라즈마 처리에 의한 마스크 특성 변화 (The Characteristic Variation of Mask with Plasma Treatment)

  • 김좌연;최상수;강병선;민동수;안영진
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.111-117
    • /
    • 2008
  • We have studied surface roughness, contamination of impurity, bonding with some gas element, reflectance and zeta potential on masks to be generated or changed during photolithography/dry or wet etching process. Mask surface roughness was not changed after photolithography/dry etching process. But surface roughness was changed on some area under MoSi film of Cr/MoSi/Qz. There was not detected any impurity on mask surface after plasma dry etching process. Reflectance of mask was increased after variable plasma etching treatment, especially when mask was treated with plasma including $O_2$ gas. Blank mask was positively charged when the mask was treated with Cr plasma etching gas($Cl_2:250$ sccm/He:20 $sccm/O_2:29$ seem, source power:100 W/bias power:20 W, 300 sec). But this positive charge was changed to negative charge when the mask was treated with $CF_4$ gas for MoSi plasma etching, resulting better wet cleaning. There was appeared with negative charge on MoSi/Qz mask treated with Cr plasma etching process condition, and this mask was measured with more negative after SC-1 wet cleaning process, resulting better wet cleaning. This mask was charged with positive after treatment with $O_2$ plasma again, resulting bad wet cleaning condition.

Impact of Wet Etching on the Tribological Performance of 304 Stainless Steel in Hydrogen Compressor Applications

  • Chan-Woo Kim;Sung-Jun Lee;Chang-Lae Kim
    • Tribology and Lubricants
    • /
    • 제40권3호
    • /
    • pp.71-77
    • /
    • 2024
  • Hydrogen has emerged as an eco-friendly and sustainable alternative to fossil fuels. However, the utilization of hydrogen requires high-pressure compression, storage, and transportation, which poses challenges to the durability of compressor components, particularly the diaphragm. This study aims to improve the durability of 304 stainless steel diaphragms in hydrogen compressors by optimizing their surface roughness and corrosion resistance through wet etching. The specimens were prepared by immersing 304 stainless steel in a mixture of sulfuric acid and hydrogen peroxide, followed by etching in hydrochloric acid for various durations. The surface morphology, roughness, and wettability of the etched specimens were characterized using optical microscopy, surface profilometry, and water contact angle measurements. The friction and wear characteristics were evaluated using reciprocating sliding tests. The results showed that increasing the etching time led to the development of micro/nanostructures on the surface, thereby increasing surface roughness and hydrophilicity. The friction coefficient initially decreased with increasing surface roughness owing to the reduced contact area but increased during long-term wear owing to the destruction and delamination of surface protrusions. HCl-30M exhibited the lowest average friction coefficient and a balance between the surface roughness and oxide film formation, resulting in improved wear resistance. These findings highlight the importance of controlling the surface roughness and oxide film formation through etching optimization to obtain a uniform and wear-resistant surface for the enhanced durability of 304 stainless steel diaphragms in hydrogen compressors.

코발트살리사이드를 위한 습식세정 공정 (Wet Cleaning Process for Cobalt Salicide)

  • 정성희;송오성
    • 한국표면공학회지
    • /
    • 제35권6호
    • /
    • pp.377-382
    • /
    • 2002
  • We investigated the appropriate wet cleaning process for Co-Ti-Si compounds formed on top of cobalt disilicide made from Co/Ti deposition and two rapid thermal annealing (RTA). We employed three wet cleaning processes, WP1 ($H_2$SO$_4$ etchant), WP2 ($NH_4$OH etchant), and WP3 which execute sequentially WP1 and WP2 after the first RTA. All samples were cleaned with BOE etchant after the second RTA. We characterized the sheet resistance with process steps by a four-point probe, the microstructure evolution by a cross detail sectional transmission electron microscope, a Auger depth profiler, and a X-ray diffractometer (XRD). We confirmed WP3 wet cleaning process were the most suitable to remove CoTiSi layer selectively.

초음파 습식 자기분류법을 이용한 MgxNiyZn1-x-yFe2O4 나노입자 제조 (Preparation of Nano-sized MgxNiyZn1-x-yFe2O4 by Ultrasonic Wet-Magnetic Separation Method)

  • 구문선;권혁주;최용
    • 한국표면공학회지
    • /
    • 제50권3호
    • /
    • pp.212-218
    • /
    • 2017
  • $Mg_xNi_yZn_{1-x-y}Fe_2O_4$ ferrite powders were prepared by self-propagating high temperature synthesis followed by classifying with an ultrasonic wet-magnetic separation unit to get high pure nano-sized particles. The $Mg_xNi_yZn_{1-x-y}Fe_2O_4$ ferrites were well formed by using several powders like iron, nickel oxide, zinc oxide and magnesium oxide at 0.1 MPa of oxygen pressure. The ultrasonic wet-magnetic separation of pre-mechanical milled ferrite powders resulted in producing the powders with average size of 800 nm. The addition of a surfactant during the wet-magnetic separation process improved productivity more than twice. The coercive force, maximum magnetization and residual magnetization of the $Mg_xNi_yZn_{1-x-y}Fe_2O_4$ nano-powders with 800 nm size were 3651 A/m, $53.92Am^2/kg$ and $4.0Am^2/kg$, respectively.

콘크리트 보수용 폴리머 복합재료의 접착강도 특성 (Adhesion Properties of Polymer Composite Materials for Concrete Repair)

  • 지경용;연규석;이윤수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.330-335
    • /
    • 1998
  • This research was conducted to evaluate the adhesion in tension of the polymer mortars for cement concrete repair. Various polymer types, binder ratios, and wet/dry conditions of the surface were considered in this study. Styrene-butadiene rubber (SBR) and ethylen vinyl acetate (EVA) used for polymer cement mortars. Epoxy resin (EP), and unsaturated polyester resin (UP) were used for polymer mertars. Adhesion in tension for the dry condition of the substrate surface was higher than that for the wet condition of the substrate surface under the same binder ratio. Therefore, in repairing concrete, the dry surface condition was effective on adhesion.

  • PDF