• 제목/요약/키워드: Wet Bulb Temperature

검색결과 86건 처리시간 0.027초

도로변 가로녹지 유형이 기상에 미치는 영향 (A Study on the Temperature Reduction Effect of Street Green Area)

  • 김정호;최원준;윤용한
    • 한국환경과학회지
    • /
    • 제26권12호
    • /
    • pp.1363-1374
    • /
    • 2017
  • Global climate change caused by industrialization has caused abnormal weather conditions such as urban temperatures and tropical nights, urban heat waves, heat waves, and heavy rains. Therefore, the study tried to analyze climate conditions and weather conditions in the streets and analyze climate factors and meteorological factors that lead to inconvenience to citizens. In the case of trees, the overall temperature, surface temperature, solar irradiance, and net radiation were measured low, and the temperature was lower in the Pedestrian road than in roads. The dry bulb temperature, the black bulb temperature, and the wet bulb temperature for the thermal evaluation showed the same tendency. In the case of thermal evaluation, there was a similar tendency to temperature in WBGT, MRT, and UTCI, and varied differences between types. Although the correlation between the meteorological environment and the thermal environment showed a statistically significant significance, the difference between the measured items was not significant. The study found that the trees were generally pleasant to weather and thermal climate in the form of trees, and the differences were mostly documented.

가소화(可塑化)된 파스타의 건조(乾燥) (The Drying of Plasticized Pasta)

  • 헨리지슈와츠버그;김공환
    • Applied Biological Chemistry
    • /
    • 제24권1호
    • /
    • pp.29-39
    • /
    • 1981
  • 삶은 스파게티를 10%, 20%와 40% 글리세린 수용액에 10분간 담가둔결과 차후의 건조 과정에서 가소화(可塑化)시키는데 충분한 글리세린을 흡수했다. 글리세린의 가소화작용으로 높은 건조온도와 건습구온도의 큰차에서도 스파게티가 균열되고 표면에 주름지는 것이 방지되었다. 그러한 보호가 가능한 건조온도와 건습구온도차는 글리세린의 농도가 높을수록 높아졌다. 건조속도의 감소에도 불구하고 스파게티의 수분활성도를 0.65로(저장안정성에 필요한 수준) 내리는데 필요한 건조시간은 글리세린양이 증가함에 따라 짧아졌다. 글리세린의 첨가로 늪은 건조온도에서 스파게티의 갈변화 정도가 심해졌고 갈변화를 유도하는 기간이 짧아졌으나 갈 변화는 모든 경우에 스파게티의 수분활성 가 건조완성에 필요한 0.65에 도달한 훨씬 후에 시작되었다. 글리세린의 첨가로 건조시간을 단축하고 더 높은 온도에서 건조할 수 있기 때문에 약간의 글리세린을 (0.15 kg glycerine/ kg dry spaghetti) 첨가함으로써 스파게티의 건조시간을 약 80%에서 93%까지 단축시킬 수 있다.

  • PDF

A Study on The Counter-Flow Cooling Tower Performance Anaysis and Experiments

  • Seo, Moo-Gyo;Kim, Young-Soo;Kim, Eun-Pil;Yoon, Jung-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권1호
    • /
    • pp.50-57
    • /
    • 2001
  • The thermal performance of cooling towers is affected by the temperature of inlet water, wet bulb temperature of entering air and water-air flow rate. In this stud${\gamma}$, the effects of these variables are simulated using NTU-method and experimentally investigated for the counter-flow cooling towers. The simulation program to evaluate these variables which affect the performance of cooling tower was developed. The maximum errors between the results of simulations and experiments were 3.8% under the standard design conditions and 5.4% under the other conditions. The performance was increased up to 46~50% as the water loading was increased from 6.8$m^3/hr{\cdot}m^2$ to 159$m^3/hr{\cdot}m^2$. The range was reduced up to 56~42% when the wet bulb temperature of the entering air was increased from 22${\circ}C$ to 29${\circ}C$.

  • PDF

대구의 2016년 폭염시기 열 스트레스 지표의 비교 (Comparison of Several Heat Stress Indices for the 2016 Heat Wave in Daegu)

  • 김지혜;김해동
    • 한국환경과학회지
    • /
    • 제26권12호
    • /
    • pp.1399-1405
    • /
    • 2017
  • We compared the spatial distribution of several heat stress indices (the Wet-Bulb Globe Temperature(WBGT) index, Environmental Stress Index (ESI), and Modified Discomfort Index(MDI)) for the heat wave of June 6~August 26, 2016, in Daegu. We calculated the heat stress indices using data from the high density urban climate observation network in Daegu. The observation system was established in February. 2013. We used data from a total of 38 air temperature observation points (23 thermometers and 18 automatic weather stations). The values of the heat stress indices indicated that the danger level was very high from 0900-2000h in downtown Daegu. The daily maximum value of the WBGT was greater than or equal to $35^{\circ}C$. The differences in the heat stress indices from downtown and rural areas were higher in the daytime than at nighttime. The maximum difference was about 4 before and after 1400h, and the time variations of the heat stress indices corresponded well. Thus, we were able to confirm that the ESI and MDI can be substituted with the WBGT index.

가정용 흡수식 냉온수기용 냉각탑의 성능특성 (Performance Characteristics of Cooling Tower on Small Absorption Chiller)

  • ;김은필;정석권;민경현;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1145-1151
    • /
    • 2004
  • The experiment of thermal performance about cross flow type cooling tower was conducted in this study. Generally the ambient air condition can affect the thermal performance of cooling tower to improve or not. However it is hard to control the cooling water temperature that we want under bad air condition or during rainy season. In this paper, the effect of variables, which the ambient air have. especially wet-bulb temperature, are experimentally investigated for controlling the cooling water temperature more successfully. The result is that there is appropriate air flow rate in respective air condition to preserve the cooling performance in the cooling tower and the maximum air flow rate can't overcome the approach under bad air condition.

태양열 이용 소용량 제습냉방시스템 (Small-Capacity Solar Cooling System by Desiccant Cooling Technology)

  • 이대영;권치호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.154-156
    • /
    • 2008
  • A prototype of the desiccant cooling system with a regenerative evaporative cooler was built and tested for the performance evaluation. The regenerative evaporative cooler is to cool a stream of air using evaporative cooling effect without an inc6rease in the humidity ratio. It is comprised of multiple pairs of dry and wet channels and the evaporation water is supplied only to the wet channels. By redirecting a portion of the air flown out of the dry channel into the wet channel, the air can be cooled down to a temperature lower than its inlet wet-bulb temperature at the outlet end of the dry channels. Incorporating a regenerative evaporative cooler eliminates the need for deep dehumidification in the desiccant rotor that is necessary to achieve low air temperature in the system with a direct evaporative cooler. Subsequently, the regenerative evaporative cooler enables the use of low temperature heat source to regenerate the dehumidifier permitting the desiccant cooling system more beneficial compared with other thermal driven air conditioners. At the ARI condition with the regeneration temperature of $60^{\circ}C$, the prototype showed the cooling capacity of 4.4 kW and COP of 0.75.

  • PDF

신규 고열 위험 업종 선정을 위한 우선순위 및 온열 위험 평가 (Prioritizing for Selection of New High-heat Risk Industries and Thermal Risk Assessment)

  • 신새미;이혜민;기노성;박정민;변상훈;김성호
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.230-246
    • /
    • 2023
  • Objectives: The climate crisis has arrived and heat-related illnesses are increasing. It is necessary to discover new high-heat risk industries and understand the environment . It is also necessary to prioritize risks of industries that have not been included in the management target to date. The study was intended to monitor and evaluate the thermal risk of high-priority workplaces. Methods: A prioritization method was developed based on five factors: occurrence of and death due to heat-related illnesses, work environment monitoring, indoor work rate, small heat source, and limited heat dissipation. it, was applied to industrial accidents caused by heat-related illnesses. Wet bulb temperature index and apparent temperature were measured in July and August at 24 workplaces in seven industries and assessed for thermal risk. Results: The wet bulb temperature index was in the range of 23.8~31.9℃, and exposure limits were exceeded in the growing of crops, food services activities and accommodation, and building construction. The apparent temperature was in the range of 26.8~36.7℃, and exceeded the temperature standard for issuing heatwave warnings in growing of crops, food services activities and accommodation, warehousing, welding, and building construction. Both temperature index in growing of crops and building construction were higher than the outside air temperature. Conclusions: In the workplace, risks in industries that have not be controlled and recognized through existing systems was identified. it is necessary to provide break times according to the work-rest time ratio required during dangerous time period.

루버형 휜을 가진 휜관형 열교환기의 착상현상 연구 (Study on the Frosting Phenomenon of the Fin and Tube Heat Exchanger with a Louvered Fin)

  • 김정국;코야마 시게루;쿠와하라 켄;박병덕
    • 한국산업융합학회 논문집
    • /
    • 제11권4호
    • /
    • pp.157-163
    • /
    • 2008
  • The present study investigated the pressure drop and the total frost mass of the louvered fin type heat exchanger, which is widely used at the air-conditioning system. The pressure drop due to the frosting phenomenon and the total frost mass were investigated by changing the wet bulb temperature condition of the inlet air. Hence the brain of 55wt% was used as a cooling solution instead of a common refrigerant. The temperature difference between the brine and the tube outside wall at the outlet of heat exchanger was $10^{\circ}C$, at maximum, higher than that at the inlet of heat exchanger. As the wet bulb temperatures were increased, the pressure drop was linearly increased due to the increment of frost mass. And the increment of heat exchange rate was smaller than that of inlet air enthalpy due to the increment of frost mass. The pressure drop of air side was rapidly increased due to the progress of frosting phenomena. The run time that the pressure drop occurred rapidly was decreased by the growth of frost.

  • PDF

Optimization of Several Environmental Factors to Human Performance by Using Taguchi Method

  • Ismail, A.R.;Haniff, M.H.M.;Yusof, M.Y.M.;Rahman, M.N.A.;Ghani, J.A.
    • Industrial Engineering and Management Systems
    • /
    • 제9권2호
    • /
    • pp.157-164
    • /
    • 2010
  • The objective of this study is to determine the dominance effects of environmental factors such as Illuminance, humidity and Wet Bulb Globe Temperature (WBGT) on the operators' productivity at Malaysian electronic industry. A case study was carried out at an electronic components assembly factory. The environmental factors examined were the Illuminance (lux), humidity and WBGT of the surrounding workstation area. Two sets of representative data including the illuminance, humidity and WBGT level and production rate were collected during the study. The production rate data were collected through observations and survey questionnaires while the illuminance level was measured using photometer model RS 180-7133, the humidity and WBGT level were measured by using Quest Temp apparatus and humidity. Taguchi Method was utilized to find the sequence of dominant factors that contributed to the productivity of operator at that specified production workstation. The study reveals that the dominant factor contributed to the productivity was WBGT, followed by illuminance and humidity.

수평형 재생증발식 냉방기의 성능시험 (Performance Test for a Horizontal Regenerative Evaporative Cooler)

  • 송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF