• 제목/요약/키워드: Western Australia

검색결과 192건 처리시간 0.049초

Occurrence of acidic and arsenic-rich groundwater in suburban Perth, Western Australia

  • Ron-Watkins;John-Angeloni;Jones, Bobak-Willis;Steve-Appleyard
    • 대한자원환경지질학회:학술대회논문집
    • /
    • 대한자원환경지질학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.80-81
    • /
    • 2003
  • The Swan Coastal Plain, on which the City of Perth (pop. 1.32 million) is situated, is formed of aeolian sands of Pleistocene-Recent age. The mainly unconsolidated sediments build a series of dune lines paralleling the coastline. The near-surface water-table sees expression in numerous shallow freshwater lakes and marshes in the interdunal depressions. The sands are highly permeable, and 〉 70% of the city’s total water supply is derived from this local aquifer. (omitted)

  • PDF

Performance of novel dynamic installed anchors during installation and monotonic pullout

  • Kim, Youngho;Rosher, Lachlan Thomas
    • Geomechanics and Engineering
    • /
    • 제18권2호
    • /
    • pp.153-159
    • /
    • 2019
  • This paper examines the results from three-dimensional dynamic finite element analysis undertaken to develop a new dynamically installed anchor (DIA). Several candidate shapes of new DIAs were selected after an investigation into previous researches of existing DIA designs. The performances of selected DIAs during the installation and loading in non-homogeneous clay were investigated through large deformation finite element (LDFE) analyses. Findings were compared to the current anchors in operation (i.e., Torpedo and Omni-Max DIA) to assess the viability of the new designs in the field. Overall, the anchor embedment depths of the novel DIAs lied under the results of OMNI-Max DIA. And also, the tracked anchor trajectory confirmed that, the novel DIAs dove deeper with stiffer travelling angle, compared to the OMNI-Max DIA. These elements are more critical and beneficial especially in a field where the achieved embedment depths are generally low.

Mixed Model Reduction to Improve Steady-State Behaviour of RLC Circuits

  • Lee, Won-Kyu;Victor Sreeram
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.75.1-75
    • /
    • 2002
  • Several model order reduction methods for large RLC circuits have been developed in the last few years. Krylop subspace based methods are extremely effective for generating the low order models of large system but there is no optimal theory for the resulting models. Alternatively, methods based truncated balanced realization have an optimality property but are too computationally expensive to use on complicated problems such as large RLC circuits. In this paper, we present a method for improving time domain response of reduced order RLC circuits. The method used here is based on combing Krylop subspace based method and truncated balanced realization method plus residualization. The metho...

  • PDF

On-line Motion Adaptation : a Hybrid Approach

  • Lee, Won-Kyu;Sreeram, Victor
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.75.3-75
    • /
    • 2002
  • 1. introduction 2. Related Work 3. Overview of the Avatar Control System 4. A Hybrid Control Method 5. Motion Conversion 6. Experimental result and Conclusion References

  • PDF

Mechanical and durability properties of self-compacting concrete with blended binders

  • Xie, T.Y.;Elchalakani, M.;Mohamed Ali, M.S.;Dong, M.H.;Karrech, A.;Li, G.
    • Computers and Concrete
    • /
    • 제22권4호
    • /
    • pp.407-417
    • /
    • 2018
  • Over the past three decades, self-compacting concrete (SCC), which is characterized by its superior rheological properties, has been gradually used in construction industry. It is now recognized that the application of SCC using supplementary cementitious materials (SCM) is highly attractive and promising technology reducing the environmental impact of the construction industry and reducing the higher materials costs. This paper presents an experimental study that investigated the mechanical and durability properties of SCCs manufactured with blended binders including fly ash, slag, and micro-silica. A total of 8 batches of SCCs were manufactured. As series of tests were conducted to establish the rheological properties, compressive strength, and durability properties including the water absorption, water permeability, rapid chloride permeability and initial surface absorption of the SCCs. The influences of the SCC strength grade, blended types and content on the properties of the SCCs are investigated. Unified reactive indices are proposed based on the mix proportion and the chemical composition of the corresponding binders are used to assess the compressive strength and strength development of the SCCs. The results also indicate the differences in the underlying mechanisms to drive the durability properties of the SCC at the different strength grades.

Durability assessment of self-compacting concrete with fly ash

  • Deilami, Sahar;Aslani, Farhad;Elchalakani, Mohamed
    • Computers and Concrete
    • /
    • 제19권5호
    • /
    • pp.489-499
    • /
    • 2017
  • Self-Compacting Concrete (SCC) is a new technology capable to flow without segregation or any addition of energy which leads to efficient construction and cost savings. In this study, the effect of replacing the Ordinary Portland Cement (OPC) with Fly Ash (FA) on the strength, durability of the concrete was investigated experimentally, and carbon footprint and cost were also assessed. Four different replacement FA ratios (0%, 20%, 40% and 60%) were used to create four SCC mixes. Standard test methods were used to determine the workability, strength, and durability of the SCC mixes including resist chloride ion penetration, water permeability, water absorption, and initial surface absorption. The axial cube compressive strength tests were performed on the SCC mixes at 1, 7, 14, 28 and 35 days. Replacing the OPC with FA had a significant positive impact on chloride iron penetration resistance and water absorption but had a considerable negative impact on the compressive strength. The SCC mix with 60% FA had 36.7% and 15.8% enhancement in the resistance to chloride ion penetration and water absorption, respectively. Evaluation of the carbon footprint and the cost of each SCC mixes showed the $CO_2$ emissions mixes 1, 2, 3 and 4 were significantly reduced by increasing the FA content from 0% to 60%. Compared with the control mix, the cost of all mixes increased when the FA content increased, but no significant differences were seen between the estimated costs of all four mixes.

Push-out resistance of concrete-filled spiral-welded mild-steel and stainless-steel tubes

  • Loke, Chi K.;Gunawardena, Yasoja K.R.;Aslani, Farhad;Uy, Brian
    • Steel and Composite Structures
    • /
    • 제33권6호
    • /
    • pp.823-836
    • /
    • 2019
  • Spiral welded tubes (SWTs) are fabricated by helically bending a steel plate and welding the resulting abutting edges. The cost-effectiveness of concrete-filled steel tube (CFST) columns can be enhanced by utilising such SWTs rather than the more conventional longitudinal seam welded tubes. Even though the steel-concrete interface bond strength of such concrete-filled spiral-welded steel tubes (CF-SWSTs) is an important consideration in relation to ensuring composite behaviour of such elements, especially at connections, it has not been investigated in detail to date. CF-SWSTs warrant separate consideration of their bond behaviour to CFSTs of other tube types due to the distinct weld seam geometry and fabrication induced surface imperfection patterns of SWTs. To address this research gap, axial push-out tests on forty CF-SWSTs were carried out where the effects of tube material, outside diameter (D), outside diameter to wall thickness (D/t), length of the steel-concrete interface (L) and concrete strength grade (f'c) were investigated. D, D/t and L/D values in the range 102-305 mm, 51-152.5 and 1.8-5.9 were considered while two nominal concrete grades, 20 MPa and 50 MPa, were used for the tests. The test results showed that the push-out bond strengths of CF-SWSTs of both mild-steel and stainless-steel were either similar to or greater than those of comparable CFSTs of other tube types. The bond strengths obtained experimentally for the tested CF-SWSTs, irrespective of the tube material type, were found to be well predicted by the guidelines contained in AISC-360.