• 제목/요약/키워드: Welded Beam

검색결과 312건 처리시간 0.024초

자동차용 강판의 $CO_2$ 레이저 빔 조사 강화 (Strengthening of Steel Sheets for Automobile by $CO_2$ Laser Beam Irradiation)

  • 서정;이제훈;김정오;오상진;조원석;이두환;신철수
    • 한국레이저가공학회지
    • /
    • 제4권2호
    • /
    • pp.21-28
    • /
    • 2001
  • The laser strengthening of 35kgf/㎟ and 60kgf/㎟ grade steel sheets is investigated by using CO$_2$ laser beam irradiation. The increase of tensile strength is dominated by the number of fully penetrated melting line. Also. the optimal laser input energy(hardness) and the number of melting line (melting width) are important variables for laser strengthening. Local strengthening by laser beam may be effective for the weight reduction of components where the tailored welded blank can not be applied.

  • PDF

2심 냉간성형 각형 CFT기둥-보 접합부의 구조거동 (Structural Behavior of Two-Seam Cold Formed Square CFT Column to Beam Connections)

  • 오헌근;김선희;박찬면;최성모
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.81-90
    • /
    • 2012
  • The concrete-filled tube (CFT) column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. Its Solution, 2 members of ㄷchennel in which Internal diaphragm is installed were welded beforehand and the method of making Rectangular Steel Tube was proposed. According to upside and downside junction shape, Internal diaphragm suggested as symmetric specimen and asymmetric specimen. The upper and lower diaphragm of the Symmetric specimen used the same horizontal and The upper diaphragm of the Asymmetric specimen used the horizontal plate and the lower diaphragm used the vertically plate. In this research, 4 T-shape column to beam steps connections were tested with cyclic loading experiment in order to evaluate the structural capability of the offered connection. Symmetric specimens be a failure in 0.03rad from beam flange. And Asymmetric specimens be a failure in 0.05rad from column interface. The comparison results of All specimens shown similar to energy absorption capacity in 0.02rad.

Cyclic tests on bolted steel and composite double-sided beam-to-column joints

  • Dubina, Dan;Ciutina, Adrian Liviu;Stratan, Aurel
    • Steel and Composite Structures
    • /
    • 제2권2호
    • /
    • pp.147-160
    • /
    • 2002
  • This paper summarises results of the research performed at the Department of Steel Structures and Structural Mechanics from the "Politehnica" University of Timisoara, Romania, in order to evaluate the performance of beam-to-column extended end plate connections for steel and composite joints. It comprises laboratory tests on steel and composite joints, and numerical modelling of joints, based on tests. Tested joints are double-sided, with structural elements realised of welded steel sections. The columns are of cruciform cross-section, while the beams are of I section. Both monotonic and cyclic loading, symmetrically and antisymmetrically, has been applied. On the basis of tested joints, a refined computer model has been calibrated using a special connection element of the computer code DRAIN 2DX. In this way, a static/dynamic structural analysis of framed structures with real characteristics of the beam to column joints is possible.

Numerical modelling of stress and deflection behaviour for welded steel beam-column

  • Soy, Ugur
    • Steel and Composite Structures
    • /
    • 제12권3호
    • /
    • pp.249-260
    • /
    • 2012
  • In this study, stress and deflection behaviours of T-type welding joint applied to HE200M steel beam and column were investigated in finite element method (FEM) under different distributed loads. In the 3D-FEM modelling, glue option was used to contact between steel materials and weld nuggets. Geometrical model was designed as 3-dimensional solid in ANSYS software program. After that, homogeneous, linear and isotropic properties were used to design to materials of model. Solid-92 having 3-dimensional, 4 faced and 10-noded was selected as element type. In consequence of mesh operation, elements of 13285 and nodes of 28086 were occurred. Load distribution was applied to top surface of steel beam to determine behaviours of stress and deflection. As a result of FEM analysis applied with the loads of 55,000 N, 110,000 N and 220,000 N, maximum values were obtained as 116 N/$mm^2$, 232 N/$mm^2$ and 465 N/$mm^2$ for stress and obtainedas 1,083 mm, 2,166 mm and 4.332 mm for deflection, respectively. When modelling results and classical calculation values were compared, it was obtained difference of 10 % for stress values and 2.5% for deflection values.

Influence of geometry and safety factor on fatigue damage predictions of a cantilever beam

  • Pecnik, Matija;Nagode, Marko;Seruga, Domen
    • Structural Engineering and Mechanics
    • /
    • 제70권1호
    • /
    • pp.33-41
    • /
    • 2019
  • The influence of two parameters on fatigue damage predictions of a variably loaded cantilever beam has been examined. The first parameter is the geometry of the cantilever beam and the weld connecting it to a rear panel. Variables of the geometry examined here include the cantilever length, the weld width on the critical cross-section and the angle of the critical cross-section. The second parameter is the safety factor, as set out by the Eurocode 3 standard. An analytical approach has been used to calculate the stresses at the critical cross-section and standard rainflow counting has been used for the extraction of the load cycles from the load history. The results here suggest that a change in the width and angle of the critical cross-section has a non-linear impact on the fatigue damage. The results also show that the angle of the critical cross-section has the biggest influence on the fatigue damage and can cause the weld to withstand fatigue better. The second parameter, the safety factor, is shown to have a significant effect on the fatigue damage calculation, whereby a slight increase in the endurance safety factor can cause the calculated fatigue damage to increase considerably.

철골 보-기둥 접합부의 내진성능 개선을 위한 실험적 연구 (An Experiemetal Study for Improvement of Seismic Performance of Steel Beam-to-Column Connections)

  • 이승준;김원기;이정웅
    • 한국지진공학회논문집
    • /
    • 제3권4호
    • /
    • pp.61-70
    • /
    • 1999
  • 1994년 Northridge 지진과 1995년 Kobe 지진에서 많은 철골구조물의 보-기둥 접합부에 발생한 규열은 내진성능이 우수한 것으로 알려진 모멘트 저항 철골골조의 내진성능 개선에 대한 연구필요성을 제시하였다 일반적으로 모멘트 저항 골조가 강한 지진을 받을 때 보-기둥 접합부는 강도의 저하없이 소성 회전변형능력이 0.015이면 만족할 수 있다고 한다. 본 연구의 목적은 강한 지진하중에서도 철골구조의 보-기둥 접합부에서 용접부의 균열이 방지되고 연성적으로 충분한 에너지를 흡수하고 소산할 수 있는 접합부의 형태를 제안하고 그 거동을 조사하는 것이다 본 연구에서는 접합부의 형태를 제안하였으며 실험을 통하여 그 거동을 분석하였다 제안된 접합부 시험체에 대한 실험결과는 용접부에 균열이 발생하지 않았으며충분한 변형능력을 나타냈다.

  • PDF

대형기둥 적용을 위한 철근콘크리트기둥-강재보 접합부의 내진성능 (Seismic Performance of RC Column-Steel Beam Connections for Large Columns)

  • 박홍근;이호준;김창수;황현종
    • 한국강구조학회 논문집
    • /
    • 제28권4호
    • /
    • pp.231-242
    • /
    • 2016
  • 대형기둥의 제작성과 시공성을 고려한 철근콘크리트기둥-강재보 접합부의 상세를 제안하였으며, 이를 적용한 접합부의 내진성능을 연구하였다. 접합부의 보강을 위하여, 교차보, 스터드, U형 타이 등의 상세를 고려하였다. 내진성능의 평가를 위해, 2/3 스케일의 대형내부접합부에 대하여 반복가력실험을 수행하였다. 실험체들은 층간변위비 4.0%를 넘는 우수한 변형능력을 발휘하였으며, 보의 항복과 접합부의 항복이 동시에 발생하였다. 최종적으로는, 접합부의 전단파괴로 하중이 감소하였다. 실험강도는 기존 설계모델과 비교되었다.

Experimental study on seismic behavior of exterior composite beam-to-column joints with large size stiffened angles

  • Wang, Peng;Wang, Zhan;Pan, Jianrong;Li, Bin;Wang, Bo
    • Steel and Composite Structures
    • /
    • 제37권1호
    • /
    • pp.15-26
    • /
    • 2020
  • The top-and-seat angles with double web angles are commonly used in the design of beam-to-column joints in Asian and North American countries. The seismic behavior analysis of these joints with large cross-section size of beam and column (often connected by four or more bolts) is a challenge due to the effects from the relatively larger size of stiffened angles and the composite action from the adjacent concrete slab. This paper presents an experimental investigation on the seismic performance of exterior composite beam-to-column joints with stiffened angles under cyclic loading. Four full-scale composite joints with different configuration (only one specimen contain top angle in concrete slab) were designed and tested. The joint specimens were designed by considering the effects of top angles, longitudinal reinforcement bars and arrangement of bolts. The behavior of the joints was carefully investigated, in terms of the failure modes, slippage, backbone curves, strength degradation, and energy dissipation abilities. It was found that the slippage between top-and-seat angles and beam flange, web angle and beam web led to a notable pinching effect, in addition, the ability of the energy dissipation was significantly reduced. The effect of anchored beams on the behavior of the joints was limited due to premature failure in concrete, the concrete slab that closes to the column flange and upper flange of beam plays an significant role when the joint subjected to the sagging moment. It is demonstrated that the ductility of the joints was significantly improved by the staggered bolts and welded longitudinal reinforcement bars.

비대칭 H형강 슬림플로어 보의 내화 성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Capacity of Asymmetric Slimflor Beam)

  • 박원섭;김흥열;김형준
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.40-45
    • /
    • 2010
  • 비대칭 H형강을 활용한 합성보는 1970년대 후반 이후 스웨덴에서 Thor beam(Hat beam)으로 발표되었으며 British Steel과 SCI는 슬림플로어 보를 개발하였다. 슬림플로어 공법은 1990년대 초반부터 유럽의 주요 선진국에서 많은 관심을 갖고 개발하여 온 건축 구조 부재의 한 형태로 2000년대에 영국에서는 열간압연 형강 그리고 핀란드에서는 비대칭 용접 형강의 관심이 집중되고 있다. 슬림플로어 공법의 가장 큰 장점은 층고 감소를 토대로 도심 건축물의 최대 10% 내외의 연면적 증가 효과와 각종 내 외장재 절감 및 자원의 절약 폐기물 감소효과 등이며 일반 합성보에 비하여 철골보의 노출면이 적어 내화 성능에서도 우수한 장점이 있다. 본 연구는 비대칭 H형강을 사용한 슬림플로어 보의 화재시 구조 성능에 관한 연구로 표준화재조건에서 강재 단면의 형상 변화를 통한 구조물의 내화 거동과 재하 하중비를 변수로 화재시 구조물의 온도 분포와 처짐을 비교 분석하는 것을 목적으로 한다.

600MPa급(SM 570 TMC) 고성능강 기둥-보 용접접합부의 탄소성 거동에 관한 연구 (A Study on Elasto-Plastic Behavior of Column-to-Beam Welded Connection with 600MPa Class High Performance Steel)

  • 김종락;오영석;백기열;장성연
    • 한국강구조학회 논문집
    • /
    • 제20권6호
    • /
    • pp.783-792
    • /
    • 2008
  • 최근 초고층 건축물의 수요에 대응하여 고성능 고강도 강재에 대한 수요가 급증하고 있으며 고층건축물에 대한 지진 피해에 대한 인식이 확산되면서 건축구조용강에 대한 요구 성능이 점차 증가하는 추세이다. 이러한 수요에 의해 600MPa 급 강재가 출현 되었으며 현재 강교량 및 초고층 건축물에 적용하려고 많은 연구가 이루어지고 있다. 새로운 강재를 적용한 골조의 수평력에 대한 거동은 자료가 부족한 실정이다. 특히 인성에 관해서는 일반구조용 강재를 적용한 기둥 보 접합부의 소성변형율과 비교하여 고강도강을 적용한 기둥보 접합부의 소성변형율 관련 설계자료가 절실히 필요하다. 따라서 본 연구에서는 600MPa급(SM570 TMC) 강재를 적용한 기둥-보 접합부의 초기연구로서 논스캘럽과 추천형스 캘럽 상세의 실구조물 규모의 기둥-보 용접접합부 실험체를 제작, 내진성능실험을 통해 구조성능을 평가하였다. 기존의 일반구조용 SM490 강재를 적용한 기존의 연구와 비교 분석하여 초고층 건축물에 적용을 위한 내진설계자료 및 제작상의 주의사항을 제시하였다.