• 제목/요약/키워드: Weir

검색결과 654건 처리시간 0.024초

저수량 오차에 의한 장찬저수지의 유역외 유입량 추정 (Estimation of Inflows to Jangchan Reservoir from Outside Watershed by Minimizing Reservoir Water Storage Errors)

  • 노재경
    • 한국농공학회논문집
    • /
    • 제52권5호
    • /
    • pp.61-68
    • /
    • 2010
  • Jangchan reservoir is located in Okcheon county, Chungbuk province, of which watershed area is $29.4\;km^2$ from outside, and $5.1\;km^2$ from inside watershed, effective storage capacity is $392{\times}10^4\;m^3$, paddy area to be irrigated is 474 ha. To determine inflows from Keumcheon weir located in outside watershed on an optimum level, a repeated procedure which is composed of simulation of inflows to Keumcheon weir, setting of range of water taking at Keumcheon weir, simulation of inflows to Jangchan reservoir, estimation of paddy water from Jangchan reservoir, and simulation of water storages in Jangchan reservoir was selected. Parameters of DAWAST model for simulating inflows to Jangchan reservoir were determined to UMAX of 315 mm, LMAX of 21 mm, FC of 130 mm, CP of 0.018, and CE of 0.007 with absolute sum of errors in reservoir water storages minimized using unconstrained Simplex method because of no inflows data. Inflows to Keumcheon weir were simulated to $2,132{\times}10^4\;m^3$ on an annual average. Optimal range of water taking at Keumcheon weir to transfer to Jangchan reservoir were $0.81{\sim}50\;mm/km^2/d$, which were summed up to $1,397{\times}10^4\;m^3$ in 66% of total on an annual average. Inflows to Jangchan reservoir were simulated to $1,739{\times}10^4\;m^3$ on an annual average of which were 80 % from Keumcheon weir of outside watershed. Requirements to paddy water from Jangchan reservoir were estimated to $543{\times}10^4\;m^3$ on an annual average.

저층수 배출식 가동보 설치에 따른 흐름특성 (The Flow Characteristic Variation by Installing a Movable Weir having Water Drainage Equipment on the Bottom)

  • 최계운;변성준;김영규;조상욱
    • 한국방재학회 논문집
    • /
    • 제8권3호
    • /
    • pp.117-122
    • /
    • 2008
  • 사람들은 수로 또는 하천에서 취수를 목적으로 하천을 횡단하는 보와 같은 수중 구조물을 설치하여 물을 임시 저류시켜 사용하는 방법을 이용하고 있으나, 구조물에 의하여 하천의 흐름이 정체되어 수질사고 및 홍수 등의 부작용이 발생하기도 한다. 본 연구에서는 다양한 가동보 중 저층수 배출식 공압식 가동보를 실험수로에 설치하여 가동보 설치각도 변화에 따른 흐름 영향을 분석하였으며, 저층수 배출을 위해 설치해 놓은 저층수 유입구에 따라 변화하는 흐름특성을 분석하였다. 분석 결과 보 설치 각도에 따라 저층수 배출장치로만 물을 배제시킬 경우 설치각도의 증가에 따라 유량은 점차 증가하며, 저층수 유입구의 유무 따른 흐름특성 변화는 유속의 경우 최대 21.9배 증가한 것을 확인할 수 있으며, 수위변화에는 크게 영향을 미치지 않는 것으로 나타났으나, 보 상류 부분에서 국부적으로 평균 이상의 수위 감소를 나타내고 있다.

FLOW-3D를 이용한 다양한 곡률에 대한 횡월류 위어의 유량계수 산정 (Discharge Coefficient of Side Weir for Various Curvatures Simulated by FLOW-3D)

  • 정창삼
    • 한국방재안전학회논문집
    • /
    • 제8권1호
    • /
    • pp.5-13
    • /
    • 2015
  • 본 연구는 수치모형을 이용하여 만곡수로 외측에 설치된 횡월류 위어의 곡률반경에 대한 횡월류 유량계수를 분석한 연구이다. 곡률반경의 변화에 따른 만곡부의 중심각이 $180^{\circ}$인 수로모형을 설계하였으며, FLOW-3D모형에 적용하여 유량계수를 산정하고 직선 수로와 비교하는 방법으로 유량계수의 특성을 분석하였다. 모형의 적용성 검증을 위해 기존에 연구되었던 수리실험과 동일한 조건의 수치모의를 수행하였다. 하폭(b)을 고정시키고 곡률반경($R_c$)을 변화시킴으로써 $R_c/b$의 변화에 따른 유량계수($C_M$)의 변화를 분석하고, 만곡수로의 월류량($Q_{wc}$)에 대한 직선수로의 월류량($Q_{wc}$)의 비를 분석하였다. 분석결과 유량계수는 상류수심, 만곡수로의 곡률반경의 변화에 따라 유량계수는 변화하였으며, 직선과 만곡수로에 대해 분석을 수행하였기 때문에 직선수로의 영향인자를 이용하여 만곡수로에 설치된 횡월류 위어의 월류량과 유량계수를 추정 가능 할 것이라 판단된다.

하구언 갑문폐쇄 후 금강하구의 물리, 퇴적학적 특성변화 (Physical and Sedimentological Changes in the Keum Estuary after the Gate-Close of Keum River Weir)

  • 최진용;최현용
    • 한국해양학회지
    • /
    • 제30권4호
    • /
    • pp.262-270
    • /
    • 1995
  • 금강 하구언 갑문의 폐쇄에 따른 금강하구의 물리, 퇴적학적 특성변화를 살펴 보 았다. 갑문쇄 이후 최대조류 유속은 갑문개방 시기에 비하여 약 30-40% 감소하였다. 또한 금강하구의 수괴유동이 둔화되어, 염분 및 수괴투명도의 수직적 성충(vertical stratification)이 형성되었다. 이에 따라 금강하구는 갑문개방기의 완전혼합형 (wellmixed type) 하구로부터 갑문쇄 이후에는 부분혼합형(partially-mixed type) 또 는 염쇄기형(salt-wedge type)하구로 변이하였다. 갑문이후 부유물함량은 표층에서 1 0∼100 mg/l의 범위로 측정되어, 갑문개방기에 비하여 약 1/4∼1/3의 수준으로 뚜렷하 게 감소하였다. 이와 같은 부유물함량의 감소경향은 첫째 조류유속이 감소하여 해저퇴 적물의 저층재부유 현상이 감소하였고, 둘째 수괴의 수직적성층이 형성되어 저층 혼탁 수의 상부확산이 둔화되었기 때문으로 변이하였고, 세립질 부유퇴적물의 퇴적작용이 보다 활발하게 나타날 것으로 예상된다.

  • PDF

어도 생태수리실험에 의한 회유성 어류의 소상능력 평가(II) - 계단식 어도 - (Assessment of Ascending Capacity of Migratory Fish in Fishways by Eco-hydraulic Experiments (II))

  • 박상덕
    • 한국수자원학회논문집
    • /
    • 제34권4호
    • /
    • pp.381-390
    • /
    • 2001
  • 본 연구는 어도 생태수리실험에 의하여 계단식 어도에서 회유성 어류의 소상능력을 평가하기 위한 것으로서 은어와 송어를 대상으로 실험하였으며, 기존 계단식 어도 설치 하천의 회유성 어류 이동생태환경을 분석하였다. 계단식 어도에서 은어의 소상능력은 낙차가 16.0cm미만으로 작을 때는 송어보다 크고, 20.0cm이상으로 낙차가 클 때는 송어의 소상능력이 은어보다 크다. 은어는 송어보다 도약을 선호하며 도약 후의 지구력은 송어가 은어에 비하여 크다. 수계별 기존 설치된 계단식 어도의 낙차가 매우 크기 때문에 은어와 송어의 이동에 관한 생태환경이 매우 불량하다. 본 연구 결과를 통하여 볼 때 고전적인 계단식 어도의 설치는 하천에 서식하는 회유성 어종의 다양성 측면을 고려하여야 하며 설계시 어도내 상류와 하류 웅덩이간 낙차는 20cm 미만으로 하여야 할 것이다.

  • PDF

HEC-6를 이용한 준설 및 보로 인한 낙동강 본류 및 지류 하상변화 분석 (Analysis of the Effect of Dredging and Weirs on Bed Change in the Nakdong River and its Tributary using HEC-6)

  • 안정민;곽성현;류시완
    • 한국수자원학회논문집
    • /
    • 제48권9호
    • /
    • pp.743-756
    • /
    • 2015
  • 효과적인 하천관리를 위해서는 준설과 각종 수리구조물의 영향에 의한 하상변화 양상을 파악하고 평가하는 것이 필수적이다. 특히 대규모 준설과 대형수리구조물의 건설은 본류뿐만 아니라 지류의 하상안정에도 영향을 미칠 수 있다. 본 연구에서는 금호강이 유입하는 낙동강 강정고령보~달성보 구간에 대해 하도준설과 보 건설 및 운영에 따른 본류와 지류에서의 장기하상변동 영향을 살펴보고자 하였다. HEC-6모형을 이용하여 유사이송 및 장기하상변동 양상을 모의하였으며, 그 결과 준설 및 보 운영으로 인해 본류뿐만 아니라 지류에서도 하상변화량이 증가하고 가속화되었다.

물리적 차단시설이 대청호 수질에 미치는 효과 분석 (Analysis the Effects of Physical Blocking Weirs on the Water Quality in Daechung Reservoir)

  • 이흥수;정세웅;박형석;정동환
    • 환경영향평가
    • /
    • 제21권1호
    • /
    • pp.25-39
    • /
    • 2012
  • This study was aimed to assess the effects of additional installation of two different types of weirs, one is a curtain-type weir and another is a submerged-type weir, on the control of algal growth in Daechung Reservoir. A two-dimensional(2D) coupled hydrodynamic and eutrophication model that can accommodate vertical movement of the curtain weir following the water surface variations was verified using field data obtained in two distinctive hydrological years; dry(2008) and wet(2010). The model adequately simulated the temporal and spatial variations of water temperature, nutrients and algal(Chl-a) concentrations during the periods. The effectiveness of curtain weir on the control of algal bloom was evaluated by applying the model to 2001(dry year) and 2010 assuming 6 different scenarios according to installation locations. The curtain weirs that already installed at 3, 5, 7 sites(scenario C-2) showed significant effect on the control of algal growth in the reservoir; the reduction rates of algal concentration were placed in the range of 7.5~31.5% and 9.1~44.9% for 2001 and 2010, respectively. However the simulation results revealed that additional installation of curtain weirs(scenario C-3~C-6) in the bay area (choosori) have marginal effect. The effectiveness of submerged weir was evaluated against 2010 assuming 7 different scenarios according to installation locations, but all scenarios(S-1~S-7) showed neglectable or negative effect on the control of algal growth.

3차원 수치모형에 의한 횡월류위어의 수리학적 평가 (The Hydraulic Assessment of Side Weir using 3D Computational Fluid Dynamics Program)

  • 남기영;한건연;박홍성;김극수;최승용
    • 환경영향평가
    • /
    • 제19권2호
    • /
    • pp.153-168
    • /
    • 2010
  • The objectives of this study are to analyze flow characteristics for a side weir, which is an inlet structure for flow discharge reduction in the main channel through 3 dimensional numerical analysis and to understand the efficiency of the overflow effect at the side weir. In this study over 40 simulations using FLOW-3D, a computational fluid dynamics program were conducted, and the results were analyzed to find the influence of the flow hydraulics, geometry, channel and weir shapes on the coefficient. It is especially considered the relatively high stage in downstream that may cause flow within channel to be backed up along the channel. Additionally by setting up the scale of simulations much larger than the existing test equipment designed by other researchers, it is intended to analyze more accurate hydraulic behavior along with the realistic hydraulic features such as structures and volumes of flow. The results show that for design with subcritical flow only if the Froude number of upstream is sustained below 0.5 and the length of weir is 33-100% of the width of channel, it is expected to improve the efficiency of the overflow over a side weir.

폭이 넓은 개수로에서의 예연횡월류위어 유량계수 산정 (Evaluation of Discharge Coefficients for Sharp Crested Side Weir in Wide Channel)

  • 이동섭;김창완
    • 대한토목학회논문집
    • /
    • 제28권5B호
    • /
    • pp.449-458
    • /
    • 2008
  • 본 연구의 목적은 De Marchi 유량계수 $C_M$의 개념을 이용하여 상대적으로 폭이 넓은 개수로에서 실험적으로 상류 조건의 직사각형 예연횡월류위어 유량계수에 대한 상류 프루드수, 위어 높이, 위어 길이, 본수로 폭의 영향을 확인하는 것이다. 수로 실험과 차원해석을 통하여 도출된 네 가지 중요 영향 변수, $Fr_1$, $h/y_1$, L/B, $L/y_1$의 영향을 관찰하고, 실험 결과를 바탕으로 새로운 예연횡월류위어 유량계수 산정식을 제안하였다. 분석 결과 폭이 넓은 개수로에서 예연횡월류위어 유량계수에 대한 $Fr_1$의 영향은 감소하는 것을 확인하였으며, $h/y_1$, L/B, $L/y_1$의 중요도가 증가하는 것으로 나타났다. 또한 기존 연구자들의 실험 자료와 본 연구의 실험 자료를 비교 분석하여 기존 예연횡월류위어 유량계수 산정식의 적용성을 개선하였다.

취입모의 경제적 계획취입수심 산정방법에 대한 연구 (A Study on a Calculation Method of Economical Intake Water Depth in the Design of Head Works)

  • 김철기
    • 한국농공학회지
    • /
    • 제20권1호
    • /
    • pp.4592-4598
    • /
    • 1978
  • The purpose of this research is to find out mathemetically an economical intake water depth in the design of head works through the derivation of some formulas. For the performance of the purpose the following formulas were found out for the design intake water depth in each flow type of intake sluice, such as overflow type and orifice type. (1) The conditional equations of !he economical intake water depth in .case that weir body is placed on permeable soil layer ; (a) in the overflow type of intake sluice, {{{{ { zp}_{1 } { Lh}_{1 }+ { 1} over {2 } { Cp}_{3 }L(0.67 SQRT { q} -0.61) { ( { d}_{0 }+ { h}_{1 }+ { h}_{0 } )}^{- { 1} over {2 } }- { { { 3Q}_{1 } { p}_{5 } { h}_{1 } }^{- { 5} over {2 } } } over { { 2m}_{1 }(1-s) SQRT { 2gs} }+[ LEFT { b+ { 4C TIMES { 0.61}^{2 } } over {3(r-1) }+z( { d}_{0 }+ { h}_{0 } ) RIGHT } { p}_{1 }L+(1+ SQRT { 1+ { z}^{2 } } ) { p}_{2 }L+ { dcp}_{3 }L+ { nkp}_{5 }+( { 2z}_{0 }+m )(1-s) { L}_{d } { p}_{7 } ] =0}}}} (b) in the orifice type of intake sluice, {{{{ { zp}_{1 } { Lh}_{1 }+ { 1} over {2 } C { p}_{3 }L(0.67 SQRT { q} -0.61)}}}} {{{{ { ({d }_{0 }+ { h}_{1 }+ { h}_{0 } )}^{ - { 1} over {2 } }- { { 3Q}_{1 } { p}_{ 6} { { h}_{1 } }^{- { 5} over {2 } } } over { { 2m}_{ 2}m' SQRT { 2gs} }+[ LEFT { b+ { 4C TIMES { 0.61}^{2 } } over {3(r-1) }+z( { d}_{0 }+ { h}_{0 } ) RIGHT } { p}_{1 }L }}}} {{{{+(1+ SQRT { 1+ { z}^{2 } } ) { p}_{2 } L+dC { p}_{4 }L+(2 { z}_{0 }+m )(1-s) { L}_{d } { p}_{7 }]=0 }}}} where, z=outer slope of weir body (value of cotangent), h1=intake water depth (m), L=total length of weir (m), C=Bligh's creep ratio, q=flood discharge overflowing weir crest per unit length of weir (m3/sec/m), d0=average height to intake sill elevation in weir (m), h0=freeboard of weir (m), Q1=design irrigation requirements (m3/sec), m1=coefficient of head loss (0.9∼0.95) s=(h1-h2)/h1, h2=flow water depth outside intake sluice gate (m), b=width of weir crest (m), r=specific weight of weir materials, d=depth of cutting along seepage length under the weir (m), n=number of side contraction, k=coefficient of side contraction loss (0.02∼0.04), m2=coefficient of discharge (0.7∼0.9) m'=h0/h1, h0=open height of gate (m), p1 and p4=unit price of weir body and of excavation of weir site, respectively (won/㎥), p2 and p3=unit price of construction form and of revetment for protection of downstream riverbed, respectively (won/㎡), p5 and p6=average cost per unit width of intake sluice including cost of intake canal having the same one as width of the sluice in case of overflow type and orifice type respectively (won/m), zo : inner slope of section area in intake canal from its beginning point to its changing point to ordinary flow section, m: coefficient concerning the mean width of intak canal site,a : freeboard of intake canal. (2) The conditional equations of the economical intake water depth in case that weir body is built on the foundation of rock bed ; (a) in the overflow type of intake sluice, {{{{ { zp}_{1 } { Lh}_{1 }- { { { 3Q}_{1 } { p}_{5 } { h}_{1 } }^{- {5 } over {2 } } } over { { 2m}_{1 }(1-s) SQRT { 2gs} }+[ LEFT { b+z( { d}_{0 }+ { h}_{0 } )RIGHT } { p}_{1 }L+(1+ SQRT { 1+ { z}^{2 } } ) { p}_{2 }L+ { nkp}_{5 }}}}} {{{{+( { 2z}_{0 }+m )(1-s) { L}_{d } { p}_{7 } ]=0 }}}} (b) in the orifice type of intake sluice, {{{{ { zp}_{1 } { Lh}_{1 }- { { { 3Q}_{1 } { p}_{6 } { h}_{1 } }^{- {5 } over {2 } } } over { { 2m}_{2 }m' SQRT { 2gs} }+[ LEFT { b+z( { d}_{0 }+ { h}_{0 } )RIGHT } { p}_{1 }L+(1+ SQRT { 1+ { z}^{2 } } ) { p}_{2 }L}}}} {{{{+( { 2z}_{0 }+m )(1-s) { L}_{d } { p}_{7 } ]=0}}}} The construction cost of weir cut-off and revetment on outside slope of leeve, and the damages suffered from inundation in upstream area were not included in the process of deriving the above conditional equations, but it is true that magnitude of intake water depth influences somewhat on the cost and damages. Therefore, in applying the above equations the fact that should not be over looked is that the design value of intake water depth to be adopted should not be more largely determined than the value of h1 satisfying the above formulas.

  • PDF