• 제목/요약/키워드: Weight calibration

검색결과 169건 처리시간 0.027초

LiDAR 센서 신호 보정 및 노이즈 필터링 기술 개발 (Signal Compensation of LiDAR Sensors and Noise Filtering)

  • 박홍순;최준호
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.334-339
    • /
    • 2019
  • In this study, we propose a compensation method of raw LiDAR data with noise and noise filtering for signal processing of LiDAR sensors during the development phase. The raw LiDAR data include constant errors generated by delays in transmitting and receiving signals, which can be resolved by LiDAR signal compensation. The signal compensation consists of two stage. First one is LiDAR sensor calibration for a compensation of geometric distortion. Second is walk error compensation. LiDAR data also include fluctuation and outlier noise, the latter of which is removed by data filtering. In this study, we compensate for the fluctuation by using the Kalman filter method, and we remove the outlier noise by applying a Gaussian weight function.

곡관의 하류에 설치된 전자기유량계의 유량신호 특성에 관한 실험적 연구(난류 유동) (An Experimental Study on Installation Effects of Pipe Elbow on the Electromagnetic Flowmeter Characteristics (Turbulent Flow))

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1613-1621
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) essentially averages the velocity distribution over the pipe cross- sectional area, and the measured value is dependent on the velocity profiles. In this study, installation effects of 90$^{\circ}$long elbow(KS B 1522, ISO 3419) on the EMF characteristics was investigated. A commercial EMF was adopted and the distribution of magnetic field in the electrodes cross section was measured. In the experiment, the national flow standard system, of which measurement uncertainty was evaluated in accordance with ISO 17025 recommendation, was used fur characterization of EMF. The leading line has 150D long straight pipe to established a fully developed flow before entering into the elbow and the elbow was installed downstream of it. then the flowmeter was tested within 50 D from the elbow. The installation effects of the flowmeter were investigated by varying the mean velocity(Reynolds No.)in pipe section, the locations and the direction of electrodes plane.($\phi$) From the experimental results, we find the optimal conditions to get most accurate measurements. Generally, the deviations from the calibration value were less than 0.5 % in farther than 10D distance from the elbow and the direction of electrode plane. $\phi$ = 90$^{\circ}$yielded the smallest measurement deviation. These characteristics were shown consistently in turbulent region regardless of the mean Reynolds number.

LC/ESI-MS를 이용한 Acrylamide의 정성확인 및 정량분석 (Quantitative Analysis and Qualification of Acrylamide Using LC/ESI-MS)

  • 박찬구;조성자;조남준;김민영;손종렬;문경화
    • 환경위생공학
    • /
    • 제19권4호
    • /
    • pp.25-33
    • /
    • 2004
  • Acrylamide, difficult to analyze by GC and GC/MS due to the polarity and low volatility, was analyzed by LC/ESI/MS in the study. Acrylamide its(molecular weight 71amu) showed m/z=72 $(M+H)^+$ and high peak intensity at 22V in SIR mode. The mass spectrum ratios of acrylamide for qualitative identification had m/z=72 in precursor ion and m/z=55 in products ion, respectively. Those ratios at 30V in SIR mode ranged from 1: 1.4 to 1:1.17 despite various acrylamide concentrations. The ion intensity ratios of acrylamide $(m/z=72,\; [M+H]^+)$ to acrylamide isotopes $(m/z=73,\;[M+H]^+)$ ranged from 100 : 3.57 to 100 : 3.92. The results verified theoretical mass spectrum ratio that was 100:3.82. The linearity of standard calibration curve was y : 520.584x + 1815.26 with $r^2=0.99.$ In quality assurance and quality control, the recovery rate ranged from 81.64 percent to 90.97 percent and relative standard deviation was less than $10\%$ with 5 repeated injections at individual standard calibration solutions. The method was applied to analyze acrylamide in food at grocery stores. Snacks made of potatoes showed the highest acrylamide concentration followed by products made of French fries, wheat, and corn.

Weigh-in-Motion load effects and statistical approaches for development of live load factors

  • Yanik, Arcan;Higgins, Christopher
    • Structural Engineering and Mechanics
    • /
    • 제76권1호
    • /
    • pp.1-15
    • /
    • 2020
  • The aim of this paper is to simply present live load factor calculation methodology formulation with the addition of a simple new future load projection procedure to previously proposed two methods. For this purpose, Oregon Weigh-in-Motion (WIM) data were used to calculate live load factors by using WIM data. These factors were calculated with two different approaches and by presenting new simple modifications in these methods. A very simple future load projection method is presented in this paper. Using four different WIM sites with different average daily truck traffic (ADTT) volume, and all year data, live load factors were obtained. The live load factors, were proposed as a function of ADTT. ADTT values of these sites correspond to three different levels which are approximately ADTT= 5,000, ADTT = 1,500 and ADTT ≤ 500 cases. WIM data for a full year were used from each site in the calibration procedure. Load effects were projected into the future for the different span lengths considering five-year evaluation period and seventy-five-years design life. The live load factor for ADTT=5,000, AASHTO HS20 loading case and five-year evaluation period was obtained as 1.8. In the second approach, the methodology established in the Manual for Bridge Evaluation (MBE) was used to calibrate the live load factors. It was obtained that the calculated live load factors were smaller than those in the MBE specifications, and smaller than those used in the initial calibration which did not convert to the gross vehicle weight (GVW) into truck type 3S2 defined by AASHTO equivalents.

객체지향 지리 데이터 모델에 의한 지하수의 오취약성 분석을 위한 관리시스템 구현 (Implementation of Management System for Contamination Vulnerability Calibration of the Ground Water by an Object-oriented Geographic Data Model)

  • 이홍로
    • 한국지리정보학회지
    • /
    • 제6권2호
    • /
    • pp.101-112
    • /
    • 2003
  • 이 논문은 객체지향 데이터 모델을 이용하여 지하수 오염 취약성 평가를 위한 시스템을 설계 구현하는 것이다. 응용 지리영역에서 지형지물을 추출하여 지리-객체로 규정하고, 관정으로부터 추출된 화학적 요소들로부터 지리-필드를 규정한다. 또한 이 지리-객체와 지리-필드 사이의 위상 관계를 보여주기 위해서 토지 이용도와 지하수에 표현된 화학 성분에 등급과 가중치를 부여한다. 지형 클래스, 행정 경계 클래스, 토지 이용 클래스와 관정 클래스는 관정 객체들 사이에 공간 관계성을 가지는 클래스합성계층구조를 이루며, 이 클래스 계층구조는 편리한 오염취약성 평가를 위한 기반이 된다. 이 연구를 통해 구현된 지하수 오염 취약성 평가를 위한 효율적인 관리시스템은 다른 자연환경의 오염 취약성 평가에도 기여할 수 있다.

  • PDF

인공신경망 기반 CFRP 복합재료 충돌 해석의 신뢰성 향상을 위한 파라미터 역추정 및 검증 (Inverse Estimation and Verification of Parameters for Improving Reliability of Impact Analysis of CFRP Composite Based on Artificial Neural Networks)

  • 박지예;김정
    • Composites Research
    • /
    • 제36권1호
    • /
    • pp.59-67
    • /
    • 2023
  • 항공우주산업에서 경량화를 위해 사용되는 CFRP 복합재료로 구성된 차체의 충격에 따른 파손은 탑승자의 안전과 직결된다. 따라서 충돌 상황에서 육안으로 확인하기 힘든 재료의 손상거동을 파악하는 것이 중요하며, 이를 구현할 수 있는 유한요소모델을 통한 연구가 필요하다. 본 연구에서는 일방향 적층 복합재료의 충돌 해석에 대해 파손 거동 예측에 적합한 유한요소모델을 구축하였다. 인공신경망 모델을 통해 LS-DYNA에서 제공하는 MAT_54 Enhanced Composite Damage 재료 모델의 교정 파라미터를 역추정하여 획득하였다. 획득한 파라미터에 대한 인공신경망 모델의 결과를 실험결과와 비교하여 신뢰성을 검증하였다. 그 결과, 교정 파라미터의 최적화를 통해 실험에 대한 정확도를 향상시킨 유한요소모델을 구축할 수 있음을 확인하였다.

The formation of Paper and the Measurement of Formation

  • Komppa, Olavi
    • 펄프종이기술
    • /
    • 제29권2호
    • /
    • pp.76-82
    • /
    • 1997
  • In paper the evenness of planar distribution of mass in a small scale is called formation (orbetter:mass formation). Traditionally formation has been assessed visually, by looking the sheet of paper against transmitted light. Different kinds of optieal testers are being usd to obtain quantitative rankings htat would be independent of the observer but would well correspond to the visual assessment. However, various raw-material and process factors do influence light trans-mittance in paper and do impair the correspondence between basis weight and the optical formation measurement (or visual assessment). As the optical formation test methods do not incorporate an efficient calib ration routine, the formation of the sophisticated paper grades of today the is rather difficult to measure optically and may lead to erroneous results. It may be concluded that the optical measurement is not suitable for paper grades with high filler content. coating, heavy calendering or that are made of heavily beaten pulp, nordoes it apply for dyed or printed papers. For this reason, visual assessment and optical evaluation shoild be replaced with a measurement that gives reliable results independent on paper grode and manufacturing process. Formation measuremend based on beta radiation is suitable for all paper grades regardless to the material contents or process treatment. It is possible to measure even dyed or printed samples. Thonks to a sim ple and relioble calibration, the results are converted to real basis weight balues that remain reliable even with time. The only beta tester commercially available is the AMBERTEC Beta Formation Tester. Formation of paper does vary locally in the web. Typically there exists a formation profile, too similarly to other properties of paper. Therefore, formation should ? ays be expressed as a mean of a sufficient amount of parallel determinations. All formation measurements should be calibrated against basis weight.

  • PDF

Using Chlorophyll(SPAD) Meter Reading and Shoot Fresh Weight for Recommending Nitrogen Topdressing Rate at Panicle Initiation Stage of Rice

  • Nguyen, Hung The;Nguyen, Lan The;Yan, Yong-Feng;Lee, Kyu-Jong;Lee, Byun-Woo
    • Journal of Crop Science and Biotechnology
    • /
    • 제10권1호
    • /
    • pp.33-38
    • /
    • 2007
  • Nitrogen management at the panicle initiation stage(PI) should be fine-tuned for securing a concurrent high yield and high quality rice production. For calibration and testing of the recommendation models of N topdressing rates at PI for target grain yield and protein content of rice, three split-split-plot design experiments including five rice cultivars and various N rates were conducted at the experimental farm of Seoul National University, Korea from 2003 to 2005. Data from the first two years of experiments were used to calibrate models to predict grain yield and milled-rice protein content using shoot fresh weight(FW), chlorophyll meter value(SPAD), and the N topdressing rate(Npi) at PI by stepwise multiple regression. The calibrated models explained 85 and 87% of the variation in grain yield and protein content, respectively. The calibrated models were used to recommend Npi for the target protein content of 6.8%, with FW and SPAD measured for each plot in 2005. The recommended N rate treatment was characterized by an average protein content of 6.74%(similar to the target protein content), reduced the coefficient of variation in protein content to 2.5%(compared to 4.6% of the fixed rate treatment), and increased grain yield. In the recommended N rate treatments for the target protein content of 6.8%, grain yield was highly dependent on FW and SPAD at PI. In conclusion, the models for N topdressing rate recommendation at PI were successful under present experimental conditions. However, additional testing under more variable environmental conditions should be performed before universal application of such models.

  • PDF

DETERMINATION OF MOISTURE AND NITROGEN ON UNDRIED FORAGES BY NEAR INFRARED REFLECTANCE SPECTROSCOPY(NIRS)

  • Cozzolino, D.;Labandera, M.;Inia La Estanzuela
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1620-1620
    • /
    • 2001
  • Forages, both grazed and conserved, provide the basis of ruminant production systems throughout the world. More than 90 per cent of the feed energy consumed by herbivorous animals world - wide were provided by forages. With such world - wide dependence on forages, the economic and nutritional necessity of been able to characterize them in a meaningful way is vital. The characterization of forages for productive animals is becoming important for several reasons. Relative to conventional laboratory procedures, Near Infrared Reflectance Spectroscopy (NIRS) offers advantages of simplicity, speed, reduced chemical waste, and more cost-effective prediction of product functionality. NIR spectroscopy represents a radical departure from conventional analytical methods, in that entire sample of forage is characterized in terms of its absorption properties in the near infrared region, rather than separate subsamples being treated with various chemicals to isolate specific components. This forces the analyst to abandon his/her traditional narrow focus on the sample (one analyte at a time) and to take a broader view of the relationship between components within the sample and between the sample and the population from which it comes. forage is usually analysed by NIRS in dry and ground presentation. Initial success of NIRS analysis of coarse forages suggest a need to better understand the potential for analysis of minimally processed samples. Preparation costs and possible compositional alterations could be reduced by samples presented to the instrument in undried and unground conditions. NIRS has gained widespread acceptance for the analysis of forage quality constituents on dry material, however little attention has been given to the use of NIRS for chemical determinations on undried and unground forages. Relatively few works reported the use of NIRS to determine quality parameters on undried materials, most of them on both grass and corn silage. Only two works have been found on the determination of quality parameters on fresh forages. The objectives of this paper were (1) to evaluate the use of NIRS for determination of nitrogen and moisture on undried and unground forage samples and (2) to explore two mathematical treatments and two NIR regions to predict chemical parameters on fresh forage. Four hundred forage samples (n: 400) were analysed in a NIRS 6500 instrument (NIR Systems, PA, USA) in reflectance mode. Two mathematical treatments were applied: 1,4,4,1 and 2,5,5,2. Predictive equations were developed using modified partial least squares (MPLS) with internal cross - validation. Coefficient of determination in calibration (${R^2}_{CAL}$) and standard error in cross-validation (SECV) for moisture were 0.92 (12.4) and 0.92 (12.4) for 1,4,4,1 and 2,5,5,2 respectively, on g $kg^{-1}$ dry weight. For crude protein NIRS calibration statistics yield a (${R^2}_{CAL}$) and (SECV) of 0.85 (19.8) and 0.85 (19.6) for 1,4,4,1 and 2,5,5,2 respectively, on a dry weight. It was concluded that NIRS is a suitable method to predict moisture and nitrogen on fresh forage without samples preparation.

  • PDF

밀에서 HPLC에 의한 데옥시니발레놀 분석의 측정불확도 산정 (Estimation of Measurement Uncertainty for the HPLC Analysis of Deoxynivalenol in Wheat)

  • 옥현이;장현주;안장혁;조재용;전향숙
    • 한국식품과학회지
    • /
    • 제41권3호
    • /
    • pp.258-264
    • /
    • 2009
  • 본 연구에서는 밀 시료에서 면역친화컬럼을 이용한 HPLC분석법으로 데옥시니발레놀을 분석함에 있어서 발생될 수 있는 측정 불확도를 GUM 지침에 따라 산정하였다. 분석과정에서의 불확도 요인은 시료량 측정, 최종 시료부피, 보관표준용액, 작업표준용액, 표준용액, 기기, 매질, 검량선 작성으로 구분하였다. 불확도 요인의 구성요인은 저울의 안정성, 분해능, 재현성, 표준물질의 순도, 분자량, 농도, 표준용액 희석, 검량선, 회수율 및 분석기기의 재현성 등이 작용하였다. 공시료에 데옥시니발레놀 300 ${\mu}g/kg$을 첨가하여 분석한 결과 $255.29{\pm}71.62$ ${\mu}g/kg$으로 측정되었다. 확장불확도는 합성표준불확도 35.81 ${\mu}g/kg$에 포함인자(k=2, 신뢰수준 95%)를 곱하여 산출하였다. 밀에서 데옥시니발레놀을 분석함에 있어 불확도에 영향을 주는 주요인자는 시료의 회수율과 검량선 작성인 것으로 파악되었다. 따라서 밀 시료에서 데옥시니발레놀 분석의 정밀성을 높이기 위해서는 회수율과 검량선 작성에 영향을 끼칠 수 있는 면역친화컬럼에 의한 시료의 정제과정과 표준물질의 희석과정에 주의를 기울이고 주기적으로 마이크로피펫을 교정하는 등 세심한 관리가 필요할 것으로 판단된다.