• Title/Summary/Keyword: Weighing System

Search Result 260, Processing Time 0.035 seconds

A Study of a Hydraulic Excavator's Test to Verify of Payload Estimation by Bucket's Motion Equation (유압 굴착기 실험을 통한 작업량 추정법 확인에 관한 연구)

  • Jeong, Hwang Hun;Lee, Min Su;Shin, Young Il
    • Journal of Drive and Control
    • /
    • v.19 no.2
    • /
    • pp.11-16
    • /
    • 2022
  • It is important to measure the excavator's work productivity that estimates the bucket's payloads on a process. If the bucket isn't filled at every working cycle, the excavator's operator has to drive the machine more to achieve his work quota. If bucket is filled over with the load, the other way around, the transferred object has to spread out on the workplace. That causes additional work to clean the site. This paper proposes a method that can estimate the bucket's payload to improve the excavator's work productivity. This method assumes that the excavator is a lumped mass system. And it uses a 3 points angle (boom link, arm link, swing) and 2 points pressure (boom cylinder's input port and output port) of measurable data. Depending on assumptions, the bucket's payload can be calculated by the payload's motion equation. And this suggested method can be verified by simple experiments.

An Image Processing System for Measuring the Weight of A Dairy Cattle (젖소 체중측정을 위한 영상처리 시스템)

  • 이대원;김현태
    • Journal of Animal Environmental Science
    • /
    • v.7 no.3
    • /
    • pp.183-190
    • /
    • 2001
  • The objective of this research was to design and construct an image processing system to measure easily and accurately cow's weight. The image processing system was built for a dairy cattle to be measured and estimated it's weight using camera and personal computer. The pixel numbers, which was derived from the image processing system, were counted to estimate the weight of a dairy cattle. They were utilized various was for finding the relationships between pixel numbers and it's real weight. Based on the results of this research the following conclusions were made: 1. It's weight could be estimated by using pixel numbers, which was captured from top and side cameras to measure it. The correlations with tea-view pixel numbers, side-view pixel numbers, superficial area pixel numbers and the volume pixel numbers were 0.909, 0.939, 0.944 and 0.965. 2. 50 cattle was used to execute an experiment with the image processing system, but average errors were big to make out the good relationship between cow's weight and pixel numbers. In order measure accurately a cattle weight, cattle weight, cattle groups would be divided by the age of cattle and further study should be carried out to be based on the results of this research. 3. The average time it took to perform the image processing to be measure it was 10 seconds, but it took 10 minutes for cattle to enter for measuring it's weight into the weighting system.

  • PDF

A Conceptual Design of HAUSAT-1(CubeSat) Satellite

  • Kim, Joon-Tae;Kim, Young-Suk;Seo, Seung-Won;Kim, Young-Hyun;Chang, Young-Keun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.61-73
    • /
    • 2002
  • This paper addresses the conceptual design results of the HAUSAT-1 (Hankuk Aviation University SATellite-1), developed by Space System Research Lab. of Hankuk Aviation Univ., which is a new generation picosatellite. This project has been funded by Korean Government for the purpose of developing the space core technology. This is the first attempt at the level of university in Korea to develop the satellite weighing less than 1kg and accelerates opportunities with low construction, low launch cost space experiment platforms. The purpose of the HAUSAT-1 project is to offer graduate and undergraduate students great opportunities to be able to understand the design process of satellite development as a team member. Its mission objectives are to track its position by the GPS receiver system, to deploy the thin film solar cell panel to generate extra power, and to measure plasma density and temperature with the plasma sensor. The HAUSAT-1 will orbit at the altitude of 650 km with 65 degree inclination angle with 12 months of design mission life. It is planned to be launched on November 2003 by Russian launch vehicle "Dnepr".

Effects of Catechin on Mixed Function Oxidase System and Oxidative Damage in Rat Liver Exposed to Microwave (전자파 조사 흰쥐 간조직의 Mixed Function Oxidase System과 산화적 손상에 미치는 Catechin의 영향)

  • 김미지;이준하;이순재
    • Journal of Nutrition and Health
    • /
    • v.34 no.3
    • /
    • pp.299-305
    • /
    • 2001
  • The purpose of this study was to investigate the effects of catechin on the changes of microsomal mixed function oxidase(MFO) system and oxidative damage in rat liver exposed to microwave. Sprague-Dawley male rats weighing 200$\pm$10g body weight were randomly assigned to one normal and microwave exposed groups: microwave exposed groups were divided three groups: catechin free diet(MW) group, 0.25% catechin(MW+0.25C) group and 0.5% catechin(MW+0.5C) group to the levels of dietary catechin supplementation. The rats were irradiated with microwave at frequency 2.45GHz for 15 min and then the changes pattern of mixed function oxidase system and oxidative damage were investigated for 16 days. The activity of XOD in MW group was increased from 4 day to 8 days after irradiation, compared to normal group and decreased to the level of normal group 16 days. But catechin supplementation group were maintained to the normal level. The contents of cytochrome P(sub)450 and NADPH cytochrome P(sub)450 reductase activities in liver of MW group was increased from 4 day to 8 day after irradiation, compared to normal group and decreased to the level of normal group at 16 day. But catechin supplementation group were recovered to the normal level. The contents of superoxide radical in liver of MW group was increased 1.28, 1.25, 1.17 fold of normal group at 4,6 and 8 days days after irradiation. respectively, but catechin supplementation group were maintained the normal level. The contents of lipifuscin in liver have a same tendency in superoxide radical contents. These result suggested that the supplementation of catechin have control the mixed function oxidase system and oxidative damage and that may help to recover tissues from microwave damage. (Korean J Nutrition 34(3) : 299~305, 2001)

  • PDF

A Guide to Education on Unit Transformation in University Liberal Arts Education (대학 교양교육에서 단위변환에 대한 교육 방향 제시)

  • kyung a jeong;hye jeong kim
    • Journal of Integrative Natural Science
    • /
    • v.16 no.4
    • /
    • pp.133-138
    • /
    • 2023
  • After the SI system of units was adopted as an international system of units, Korea made a lot of efforts such as administrative and educational guidance on the traditional units that had been used so far. In addition, from July 1, 2007, the government has cracked down on the denotation of non-statutory units of measurement as standard units or auxiliary units in commercial transactions. However, non-statutory weighing units are still used in other forms. It is believed that this is because non-statutory units (= our traditional units) are permeated in our lives and are convenient to use. The general public still finds it difficult to use and mark the SI system of units correctly. This is not a problem unique to Korea. However, if you look at the books that are currently used as university physics textbooks, the SI system of units and the non-legal units of other countries are marked in such a way that they can be accurately converted. Only the traditional units of our country are disappearing under the pretext of unit unification. Accordingly, we propose that our units should not be neglected in university education, but should be labeled together. The purpose of this study is to raise the necessity of reorganizing the unit conversion between the SI unit system and the traditional life improvement unit, which continues to be the convenience of life, and applying it in university physics education to enable the conversion with our traditional unit, and to educate the importance of the meaning and function of our traditional unit.

Customized Recipe Recommendation System Implemented in the form of a Chatbot (챗봇 형태로 구현한 사용자 맞춤형 레시피 추천 시스템)

  • Ahn, Ye-Jin;Cho, Ha-Young;Kang, Shin-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.543-550
    • /
    • 2020
  • Interest in food recipe retrieval systems has been increasing recently. Most computer-based recipe retrieval systems are searched by cooking name or ingredient name. Since each recipe provides information in different weighing units, recalculations to the desired amount are necessary and inconvenient. This paper introduces a computer system that addresses these inconveniences. The system is a chatbot system, based on web-based recipe recommendations, for users familiar with the use of messenger conversation systems. After selecting the most popular recipes by their names, and pre-processing to extract only information required for the recipes, the system recommends recipes based on the 100,000 data. Recipes are then searched by the names of food ingredients (included and excluded). Recalculations are performed based on the number of servings entered by the user. A satisfaction rate for the systems' recommendations was 90.5%.

Effects of Vitamin E on the Microsomal Mixed Function Oxidase System of Kidney in Streptozotocin-induced Diabetic Rats (식이 Vitamin E가 Streptozotocin 유발 당뇨쥐 신장조직에서의 Microsomal Mixed Function Oxidase System에 미치는 영향)

  • 신주영
    • Journal of Nutrition and Health
    • /
    • v.33 no.6
    • /
    • pp.619-624
    • /
    • 2000
  • The purpose of this study was to investigate the effects of vitamin E on microsomal mixed function oxidase system of kidney in streptozotocin(STZ) induced diabetic rats. Sprague-Dawley male rats weighing 140$\pm$10g were randomly assigned to one control and three STZ-diabetic groups which were subdivided into vitamin E free diet(DM-0E group) 40mg vitamin E per kg diet(DM-40E group) and 400mg vitamin E per kg diet(DM-400E group). Vitamin E level of normal group was 40 mg per kg diet. Diabetes was experimentally induced by intravenous administration of 55 mg/kg B.W of STZ in citrate buffer(pH4.3) after 4 weeks feeding of experimental diets. Animals were sacrificed at the 6th day of diabetic state. The contents of cytochrome P450 in kidney were increased by 82, 54, 41% in DM-0E, DM-40E and DM-400E groups respectively when compared with normal group. The contents of cytochrome b5 in kidney were increased by 28% in DM-0E when compared with normal group but those of DM-40E and DM-400E groups were similar to that of normal group. The activities of NADPH-cytochrome P450 reductase in kidney that were increased by 35% in DM-0E group. Levels of TBARS(thiobarbituric acid reactive substance) in kidney were increased by 207, 129% and 72% in DM-0E and DM-400E groups respectively when compared with normal group but those of DM-40E and DM-400E groups were 26,44% lower than that of DM-0E groups. It is know that the activities of MFO system and lipid peroxidation were inhibited in kidney of STZ-induced diabetic rat by administeration of high doses of vitamin E.(Korean J Nutrition 33(6) : 619~624, 2000)

  • PDF

Microcomputer-based Data Acquisition System for the Measurements of Temperature and Weight in Food Processing (마이크로 컴퓨터를 이용한 식품가공(食品加工) 공정중(工程中)의 온도및 무게 측정용(測定用) Analog-digital 변환(變換)및 접속(接續) 시스템의 제작(製作))

  • Choi, Boo-Dol;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.129-133
    • /
    • 1987
  • To develop a microcomputer-based data acquisition system for measurement of variables such as temperature and weight in food process, a low-cost data acquisition system was developed using an Apple II microcomputer. The system consisted of a microcomputer, a temperature sensor made of pt-100, a strain gauge load cell for weighing, a preamplifier for signal conditionings and an interface device. Interface device was built with programmable interface chip MC 6821, tristate buffer 74244 and analog-to-digital converter ADC 0809. The analog signals of temperature and weight were serially acquisited upon the program. The BASIC language was used for operating the data acquisition and data handling programs. The system successfully measured the variables such as temperature and weight with various sampling intervals in food dehydration process.

  • PDF

Development of a smart rain gauge system for continuous and accurate observations of light and heavy rainfall

  • Han, Byungjoo;Oh, Yeontaek;Nguyen, Hoang Hai;Jung, Woosung;Shin, Daeyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.334-334
    • /
    • 2022
  • Improvement of old-fashioned rain gauge systems for automatic, timely, continuous, and accurate precipitation observation is highly essential for weather/climate prediction and natural hazards early warning, since the occurrence frequency and intensity of heavy and extreme precipitation events (especially floods) are recently getting more increase and severe worldwide due to climate change. Although rain gauge accuracy of 0.1 mm is recommended by the World Meteorological Organization (WMO), the traditional rain gauges in both weighting and tipping bucket types are often unable to meet that demand due to several existing technical limitations together with higher production and maintenance costs. Therefore, we aim to introduce a newly developed and cost-effective hybrid rain gauge system at 0.1 mm accuracy that combines advantages of weighting and tipping bucket types for continuous, automatic, and accurate precipitation observation, where the errors from long-term load cells and external environmental sources (e.g., winds) can be removed via an automatic drainage system and artificial intelligence-based data quality control procedure. Our rain gauge system consists of an instrument unit for measuring precipitation, a communication unit for transmitting and receiving measured precipitation signals, and a database unit for storing, processing, and analyzing precipitation data. This newly developed rain gauge was designed according to the weather instrument criteria, where precipitation amounts filled into the tipping bucket are measured considering the receiver's diameter, the maximum measurement of precipitation, drainage time, and the conductivity marking. Moreover, it is also designed to transmit the measured precipitation data stored in the PCB through RS232, RS485, and TCP/IP, together with connecting to the data logger to enable data collection and analysis based on user needs. Preliminary results from a comparison with an existing 1.0-mm tipping bucket rain gauge indicated that our developed rain gauge has an excellent performance in continuous precipitation observation with higher measurement accuracy, more correct precipitation days observed (120 days), and a lower error of roughly 27 mm occurred during the measurement period.

  • PDF

Effect of Seeds Extract of Paeonia Lactiflora on Antioxidative System and Lipid Peroxidation of Liver in Rats Fed High-Cholesterol Diet (작약(Paeonia Lactiflora Pall.)씨 추출물이 고콜레스테롤 식이 흰쥐 간조직의 항상화계와 지질과산화에 미치는 영향)

  • 이정민;최상원;조성희;이순재
    • Journal of Nutrition and Health
    • /
    • v.36 no.8
    • /
    • pp.793-800
    • /
    • 2003
  • This study was conducted to investigate the antioxidative effects of Paeonia lactiflora (PL) seeds on antioxidative defense system and lipid peroxidation of liver in rats fed high-cholesterol diet. Sprague-Dawley male rats weighing 100 $\pm$10g were randomly assigned into five experimental groups fed 0.5% cholesterol ; HC group which was not supplemented PL seeds extract, 0.1% methanol extract diet group (MP1 group), 0.2% methanol extract diet group (MP2 group), 0.05% ether-souble fraction diet group (EP1 group) and 0.1 % ether-souble fraction diet group (EP2 group). Experimental diets were fed ad libitum to the rats for 3 weeks. The activity of hepatic superoxide dismutase (SOD) was not significantly different among all the high cholesterol diet groups. The hepatic glutathione peroxidase (GSHpx) activity in MP2 group was increased to 27% compared to HC group. The activity of hepatic catalase (CAT) was not significantly different among the all high cholesterol diet groups. The hepatic glutathione S-transferase (GST) activity in the EP1 and EP2 groups were increased to 12% and 13%, respectively, as compared to HC group. The levels of hepatic TBARS in the MP1, MP2, EP1 and EP2 groups were reduced by 18%, 21%, 20% and 23%, respectively, as compared with HC group. The contents of lipofuscin in liver was not significantly different among all the experimental groups. The results indicated that PL seeds extract may be reduced oxidative damage by activating antioxidative defense system of hepatic in rats fed high-cholesterol diets. (Korean J Nutrition 36(8): 793∼800, 2003)