It is important to measure the excavator's work productivity that estimates the bucket's payloads on a process. If the bucket isn't filled at every working cycle, the excavator's operator has to drive the machine more to achieve his work quota. If bucket is filled over with the load, the other way around, the transferred object has to spread out on the workplace. That causes additional work to clean the site. This paper proposes a method that can estimate the bucket's payload to improve the excavator's work productivity. This method assumes that the excavator is a lumped mass system. And it uses a 3 points angle (boom link, arm link, swing) and 2 points pressure (boom cylinder's input port and output port) of measurable data. Depending on assumptions, the bucket's payload can be calculated by the payload's motion equation. And this suggested method can be verified by simple experiments.
The objective of this research was to design and construct an image processing system to measure easily and accurately cow's weight. The image processing system was built for a dairy cattle to be measured and estimated it's weight using camera and personal computer. The pixel numbers, which was derived from the image processing system, were counted to estimate the weight of a dairy cattle. They were utilized various was for finding the relationships between pixel numbers and it's real weight. Based on the results of this research the following conclusions were made: 1. It's weight could be estimated by using pixel numbers, which was captured from top and side cameras to measure it. The correlations with tea-view pixel numbers, side-view pixel numbers, superficial area pixel numbers and the volume pixel numbers were 0.909, 0.939, 0.944 and 0.965. 2. 50 cattle was used to execute an experiment with the image processing system, but average errors were big to make out the good relationship between cow's weight and pixel numbers. In order measure accurately a cattle weight, cattle weight, cattle groups would be divided by the age of cattle and further study should be carried out to be based on the results of this research. 3. The average time it took to perform the image processing to be measure it was 10 seconds, but it took 10 minutes for cattle to enter for measuring it's weight into the weighting system.
Kim, Joon-Tae;Kim, Young-Suk;Seo, Seung-Won;Kim, Young-Hyun;Chang, Young-Keun
International Journal of Aeronautical and Space Sciences
/
v.3
no.1
/
pp.61-73
/
2002
This paper addresses the conceptual design results of the HAUSAT-1 (Hankuk Aviation University SATellite-1), developed by Space System Research Lab. of Hankuk Aviation Univ., which is a new generation picosatellite. This project has been funded by Korean Government for the purpose of developing the space core technology. This is the first attempt at the level of university in Korea to develop the satellite weighing less than 1kg and accelerates opportunities with low construction, low launch cost space experiment platforms. The purpose of the HAUSAT-1 project is to offer graduate and undergraduate students great opportunities to be able to understand the design process of satellite development as a team member. Its mission objectives are to track its position by the GPS receiver system, to deploy the thin film solar cell panel to generate extra power, and to measure plasma density and temperature with the plasma sensor. The HAUSAT-1 will orbit at the altitude of 650 km with 65 degree inclination angle with 12 months of design mission life. It is planned to be launched on November 2003 by Russian launch vehicle "Dnepr".
The purpose of this study was to investigate the effects of catechin on the changes of microsomal mixed function oxidase(MFO) system and oxidative damage in rat liver exposed to microwave. Sprague-Dawley male rats weighing 200$\pm$10g body weight were randomly assigned to one normal and microwave exposed groups: microwave exposed groups were divided three groups: catechin free diet(MW) group, 0.25% catechin(MW+0.25C) group and 0.5% catechin(MW+0.5C) group to the levels of dietary catechin supplementation. The rats were irradiated with microwave at frequency 2.45GHz for 15 min and then the changes pattern of mixed function oxidase system and oxidative damage were investigated for 16 days. The activity of XOD in MW group was increased from 4 day to 8 days after irradiation, compared to normal group and decreased to the level of normal group 16 days. But catechin supplementation group were maintained to the normal level. The contents of cytochrome P(sub)450 and NADPH cytochrome P(sub)450 reductase activities in liver of MW group was increased from 4 day to 8 day after irradiation, compared to normal group and decreased to the level of normal group at 16 day. But catechin supplementation group were recovered to the normal level. The contents of superoxide radical in liver of MW group was increased 1.28, 1.25, 1.17 fold of normal group at 4,6 and 8 days days after irradiation. respectively, but catechin supplementation group were maintained the normal level. The contents of lipifuscin in liver have a same tendency in superoxide radical contents. These result suggested that the supplementation of catechin have control the mixed function oxidase system and oxidative damage and that may help to recover tissues from microwave damage. (Korean J Nutrition 34(3) : 299~305, 2001)
After the SI system of units was adopted as an international system of units, Korea made a lot of efforts such as administrative and educational guidance on the traditional units that had been used so far. In addition, from July 1, 2007, the government has cracked down on the denotation of non-statutory units of measurement as standard units or auxiliary units in commercial transactions. However, non-statutory weighing units are still used in other forms. It is believed that this is because non-statutory units (= our traditional units) are permeated in our lives and are convenient to use. The general public still finds it difficult to use and mark the SI system of units correctly. This is not a problem unique to Korea. However, if you look at the books that are currently used as university physics textbooks, the SI system of units and the non-legal units of other countries are marked in such a way that they can be accurately converted. Only the traditional units of our country are disappearing under the pretext of unit unification. Accordingly, we propose that our units should not be neglected in university education, but should be labeled together. The purpose of this study is to raise the necessity of reorganizing the unit conversion between the SI unit system and the traditional life improvement unit, which continues to be the convenience of life, and applying it in university physics education to enable the conversion with our traditional unit, and to educate the importance of the meaning and function of our traditional unit.
Journal of the Korea Academia-Industrial cooperation Society
/
v.21
no.5
/
pp.543-550
/
2020
Interest in food recipe retrieval systems has been increasing recently. Most computer-based recipe retrieval systems are searched by cooking name or ingredient name. Since each recipe provides information in different weighing units, recalculations to the desired amount are necessary and inconvenient. This paper introduces a computer system that addresses these inconveniences. The system is a chatbot system, based on web-based recipe recommendations, for users familiar with the use of messenger conversation systems. After selecting the most popular recipes by their names, and pre-processing to extract only information required for the recipes, the system recommends recipes based on the 100,000 data. Recipes are then searched by the names of food ingredients (included and excluded). Recalculations are performed based on the number of servings entered by the user. A satisfaction rate for the systems' recommendations was 90.5%.
The purpose of this study was to investigate the effects of vitamin E on microsomal mixed function oxidase system of kidney in streptozotocin(STZ) induced diabetic rats. Sprague-Dawley male rats weighing 140$\pm$10g were randomly assigned to one control and three STZ-diabetic groups which were subdivided into vitamin E free diet(DM-0E group) 40mg vitamin E per kg diet(DM-40E group) and 400mg vitamin E per kg diet(DM-400E group). Vitamin E level of normal group was 40 mg per kg diet. Diabetes was experimentally induced by intravenous administration of 55 mg/kg B.W of STZ in citrate buffer(pH4.3) after 4 weeks feeding of experimental diets. Animals were sacrificed at the 6th day of diabetic state. The contents of cytochrome P450 in kidney were increased by 82, 54, 41% in DM-0E, DM-40E and DM-400E groups respectively when compared with normal group. The contents of cytochrome b5 in kidney were increased by 28% in DM-0E when compared with normal group but those of DM-40E and DM-400E groups were similar to that of normal group. The activities of NADPH-cytochrome P450 reductase in kidney that were increased by 35% in DM-0E group. Levels of TBARS(thiobarbituric acid reactive substance) in kidney were increased by 207, 129% and 72% in DM-0E and DM-400E groups respectively when compared with normal group but those of DM-40E and DM-400E groups were 26,44% lower than that of DM-0E groups. It is know that the activities of MFO system and lipid peroxidation were inhibited in kidney of STZ-induced diabetic rat by administeration of high doses of vitamin E.(Korean J Nutrition 33(6) : 619~624, 2000)
To develop a microcomputer-based data acquisition system for measurement of variables such as temperature and weight in food process, a low-cost data acquisition system was developed using an Apple II microcomputer. The system consisted of a microcomputer, a temperature sensor made of pt-100, a strain gauge load cell for weighing, a preamplifier for signal conditionings and an interface device. Interface device was built with programmable interface chip MC 6821, tristate buffer 74244 and analog-to-digital converter ADC 0809. The analog signals of temperature and weight were serially acquisited upon the program. The BASIC language was used for operating the data acquisition and data handling programs. The system successfully measured the variables such as temperature and weight with various sampling intervals in food dehydration process.
Proceedings of the Korea Water Resources Association Conference
/
2022.05a
/
pp.334-334
/
2022
Improvement of old-fashioned rain gauge systems for automatic, timely, continuous, and accurate precipitation observation is highly essential for weather/climate prediction and natural hazards early warning, since the occurrence frequency and intensity of heavy and extreme precipitation events (especially floods) are recently getting more increase and severe worldwide due to climate change. Although rain gauge accuracy of 0.1 mm is recommended by the World Meteorological Organization (WMO), the traditional rain gauges in both weighting and tipping bucket types are often unable to meet that demand due to several existing technical limitations together with higher production and maintenance costs. Therefore, we aim to introduce a newly developed and cost-effective hybrid rain gauge system at 0.1 mm accuracy that combines advantages of weighting and tipping bucket types for continuous, automatic, and accurate precipitation observation, where the errors from long-term load cells and external environmental sources (e.g., winds) can be removed via an automatic drainage system and artificial intelligence-based data quality control procedure. Our rain gauge system consists of an instrument unit for measuring precipitation, a communication unit for transmitting and receiving measured precipitation signals, and a database unit for storing, processing, and analyzing precipitation data. This newly developed rain gauge was designed according to the weather instrument criteria, where precipitation amounts filled into the tipping bucket are measured considering the receiver's diameter, the maximum measurement of precipitation, drainage time, and the conductivity marking. Moreover, it is also designed to transmit the measured precipitation data stored in the PCB through RS232, RS485, and TCP/IP, together with connecting to the data logger to enable data collection and analysis based on user needs. Preliminary results from a comparison with an existing 1.0-mm tipping bucket rain gauge indicated that our developed rain gauge has an excellent performance in continuous precipitation observation with higher measurement accuracy, more correct precipitation days observed (120 days), and a lower error of roughly 27 mm occurred during the measurement period.
This study was conducted to investigate the antioxidative effects of Paeonia lactiflora (PL) seeds on antioxidative defense system and lipid peroxidation of liver in rats fed high-cholesterol diet. Sprague-Dawley male rats weighing 100 $\pm$10g were randomly assigned into five experimental groups fed 0.5% cholesterol ; HC group which was not supplemented PL seeds extract, 0.1% methanol extract diet group (MP1 group), 0.2% methanol extract diet group (MP2 group), 0.05% ether-souble fraction diet group (EP1 group) and 0.1 % ether-souble fraction diet group (EP2 group). Experimental diets were fed ad libitum to the rats for 3 weeks. The activity of hepatic superoxide dismutase (SOD) was not significantly different among all the high cholesterol diet groups. The hepatic glutathione peroxidase (GSHpx) activity in MP2 group was increased to 27% compared to HC group. The activity of hepatic catalase (CAT) was not significantly different among the all high cholesterol diet groups. The hepatic glutathione S-transferase (GST) activity in the EP1 and EP2 groups were increased to 12% and 13%, respectively, as compared to HC group. The levels of hepatic TBARS in the MP1, MP2, EP1 and EP2 groups were reduced by 18%, 21%, 20% and 23%, respectively, as compared with HC group. The contents of lipofuscin in liver was not significantly different among all the experimental groups. The results indicated that PL seeds extract may be reduced oxidative damage by activating antioxidative defense system of hepatic in rats fed high-cholesterol diets. (Korean J Nutrition 36(8): 793∼800, 2003)
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.