• 제목/요약/키워드: Weighing

검색결과 1,663건 처리시간 0.031초

개에서 골판을 이용한 비개방성 양측성 하악골절의 수복 (Repair of Closed Bilateral Mandibular Fractures Using Bone Plate and Screw in Dogs)

  • 정순욱;한현정;김지선;김준영;정만복
    • 한국임상수의학회지
    • /
    • 제20권1호
    • /
    • pp.138-141
    • /
    • 2003
  • First case, a one-year-old female Shih Tzu weighing 3 kg with closed transverse fractures of bilateral mandibular body between 2nd and 3rd premolar teeth were treated surgically with bone plates and screws, and cranial luxation of temporomandibular joints were reduced to closed method. Second case, a 8.4 years old male Yorkshire terrier weighing 2.6 kg with closed transverse/oblique fractures of bilateral mandibular body between premolar and molar teeth were treated surgically with bone plates and screws. Radiographic examination revealed that the fractures in two cases fixed well and temporomandibular joint was stabilized. One month after operation, jaw activity was excellent and malocclusion wasn't observed.

사물인터넷을 이용한 식이섭취 조사방법 개발 시나리오 (Development Scenario of Dietary Intake Survey Using Internet of Things (IoT))

  • 이자연;장은재
    • 대한영양사협회학술지
    • /
    • 제22권3호
    • /
    • pp.225-231
    • /
    • 2016
  • The study suggests the possibility of using internet of things for a dietary intake survey. The development scenario of the dietary intake survey was composed of a weighing sensor for measuring food weight, bluetooth module for communicating through smart-phones, and smart-phone application. The weighing sensor attached to the bottom of utensils was designed to measure the weight of initial food & food eaten, and the results were transmitted to the smart-phone through the bluetooth module. The exclusive application in the smart-phone displayed the results of the amount of food intake, calorie intake, and eating rate. Through this system, subjects could continuously monitor their dietary intake & eating rate and recognize their actual eating environment, which leads to prevent overconsumption of food intake & form balanced eating habits. Based on this system, we need to consolidate and develop a weight control program.

액체용 유량계 교정시스템의 Diverter 불확도 특성 연구 (Uncertainty Characteristics of Diverter for Flowmeter Calibration System)

  • 이동근;박종호
    • 한국유체기계학회 논문집
    • /
    • 제11권3호
    • /
    • pp.50-55
    • /
    • 2008
  • The diverter system is a key component in achieving a high accuracy liquid flow rate standard using a static gravimetric system with a flying start and stop method. The diverter is a moving device used to direct flow alternately along its normal course(by pass) or towards the weighing tank. The time needed for collection into the weighing tank is measured using a timer. So it is important to the diversion period is sufficiently fast and triggering point of timer which is determined the filling time. On this studies show that uncertainty of diverter system for changing diversion speed and triggering point was estimated in accordance with Guide to The Expression of Uncertainty in Measurement(ISO).

Load cell 중량센서의 FEM simulation (FEM simulations of load cell weighing sensor)

  • 박찬원
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권3호
    • /
    • pp.200-205
    • /
    • 1994
  • The FEM technique was applied to simulate the change of stress characteristics for various structural parameters and loading positions of the load cell. The output voltage of the load cell was then computed to compare with the manufactured load cell. The tendency of the stress variations of the load cell was well agreed with the basic formula of the single fixed. beam. Also, the stress characteristics according to the change of loading positions showed respective featured results as different structure. The calculated output voltages of the load cell were very close to those of the real manufactured ones.

  • PDF

개에서 편측성 난소낭종의 방사선학적 및 초음파학적 진단 2례 (Radiographic and Ultrasonographic Diagnosis of Unilateral Ovarian Cysts)

  • 이기창;최민철
    • 한국임상수의학회지
    • /
    • 제19권3호
    • /
    • pp.367-370
    • /
    • 2002
  • A female, 14-year-old mixed dog weighing 4 kg and a female,8-year-old schnauzer dog weighing 6 kg showing vaginal discharges and vomiting for a few weeks were examined for the preoperative check of anterior cruciate ligament rupture and the recheck after the surgery of nephrectomy. There were no distinct abnormal signs except for the increased CBC at schnauzer dog on blood chemistry analysis. Radiographic and ultrasonographic findings were a large abdominal mass and a cyst-like hypoechogenic or anechogenic cavitary lesion on the ovary region. These findings were consistent with an ovarian cyst. Thereafter highly suspected ovarian cysts by diagnostic imaging were supported by high estrogen concentration on hormonal assay and the results of Pathologic examination as the unilateral ovarian cysts with secondary pyometra.

개에서 신우신염의 방사선학적 및 초음파학적 진단 2례 (Radiogyaphic and Ultrasonographic Diagnosis of Pyelonephritis in 2 dogs)

  • 이기창;최민철
    • 한국임상수의학회지
    • /
    • 제19권3호
    • /
    • pp.371-374
    • /
    • 2002
  • A female 8-year-old Pug weighing 7.3 kg and a female 10-year-old Maltese dog weighing 3.5 kg showing anorexia and vomiting for a few weeks were referred to Veterinary Medical leaching Hospital, Seoul National University. Radiographic findings were an enlarged right kidney in a pug dog and a radiopaque material on the right ureteral region lateral to the third lumbar vertebrae with indefinite right kidney contour in a Maltese dog, repectively. Excretory urography performed in a Pug dog revealed a poor opacified enlarged right kidney with absent of pelvic recesses and pelvic dilation with proximal ureteral dilation on contralateral kidney. Ultrasonographic findings were enlarged kidney with dilated pelvis and echogenic sediment within the medulla in both dogs and especially an engorged proximal ureter and a thin rim of functional renal tissue remains in a Maltese dog. Those diagnostic findings indicated high possibility of pyelonephritis and these were confirmed by pathologic examination. Radiography and ultrasonography, although not giving final diagnosis for pyelonephritis, are useful for assessment and diagnosis of pyelonephritis.

Prompt neutron lifetime calculations for the NIRR-1 reactor

  • Ibrahim, Yakubu V.;Adeleye, Micheal O.;Njinga, Raymond L.;Odoi, Henry C.;Jonah, Sunday A.
    • Advances in Energy Research
    • /
    • 제3권2호
    • /
    • pp.125-131
    • /
    • 2015
  • Prompt neutron lifetime calculations have been performed for the NIRR-1 reactor HEU and LEU cores using the 1/v insertion and the Adjoint flux weighing methods. Results of calculations obtained for the HEU and LEU cores are respectively $57.3{\pm}0.8$ and $47.5{\pm}0.7$ for the 1/v insertion and $56.9{\pm}0.3$ and $46.3{\pm}0.5$ for the Adjoint flux. There is a good agreement seen between the two methods for both cores. The prompt neutron lifetime was observed to be shorter in the LEU than for the HEU as expected. However, the Adjoint flux weighing method seemed to be the easiest method in calculating the prompt neutron lifetime for NIRR-1.

VCA(Voice Coil Actuator) 구동 평형저울에서 VCA 자기 감쇠 특성이 측정 속도에 미치는 영향 (Effect of Magnetic Damping on Measurement Speed in a VCA-driven Balancing Scale)

  • 안지윤;안중환
    • 센서학회지
    • /
    • 제28권4호
    • /
    • pp.246-250
    • /
    • 2019
  • In this study, in conjunction with a SIMULINK program based on system modeling of a voice-coil-actuator (VCA)-driven balancing scale, a proportional-integral-derivative control algorithm is implemented, and weighing characteristics are investigated through experiments and simulations. The extent to which the back electromotive force induced in the VCA-driven circuit and the magnetic damping induced by the coil wound bobbin of VCA affect the weighing speed is also investigated.

이송 물체의 질령 측정 속도 및 정밀도 향상 모사 연구 (Development of Speed and Precision in the Mass Measurement of Moving Object)

  • 이우갑;정진완;김광표
    • 한국정밀공학회지
    • /
    • 제11권6호
    • /
    • pp.136-142
    • /
    • 1994
  • This study presents an algorithm and related techniques which could satisfy the important properties of check weighers and conveyor scales. The algorithm of Recursive Least Squares Regression is described for te weighing system simulated as a dynamic model of the second order. Using the model and the algorithm, model parameters and then the mass being weighed can be determined from the step input. The performance of the algorithm is illustrated in digital simulation. Discussions are extended to the development of fast converging algorithm. It turns out that the algorithm shows several desirable features suitable for microcomputer assisted real-time signal processing, which are high precision and stability in noisy environment.

  • PDF