• Title/Summary/Keyword: Wearing effect

Search Result 540, Processing Time 0.025 seconds

A STUDY ON PROFILE CHANGE AND STABILITY OF TREATMENT AFTER WEARING FACE MASK (상악골 전방견인 장치 사용후 측모 변화 및 안정성에 대한 연구)

  • Park, Young-Chel;Shin, Ja-Young;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.1-20
    • /
    • 1997
  • Skeletal Class III malocclusions are growth-related discrepancies, and the problems are more severe until growth is complete. Causes of skeletal Class III malocclusion are classified into mandibular overgrowth, maxillary deficiency, and combination of the two. Face mask has been recommended for treatment of Class III malocclusion with maxillary deficiency in the early time of growth. Numerous experiments were performed and clinical studies have been reported on face mask ; nevertheless, studies on profile changes and stability after treatment of face mask are considered to be somewhat insufficient. The author selected 50 patients who can be checked for follow-up. They had been diagnosed as skeletal Class III malocclusion with maxillary deficiency and then treated with face mask ; the sample group was divided according to sex, treatment beginning age, palatal suture opening (intraoral appliance). For each group, changing pattern of facial profile and stability of treatment observed, and comparison with 20 Korean normal children(Angle's Class I). The following results were obtained. 1. skeletal, dental, and soft tissue measurements indicated more changes in the amounts of maxillary forward movement during face mask treatment. 2. R.P.E. group showed more significant maxillofacial changes and La-Li group showed more dental changes. 3. Growth changes of maxilla induced in the treatment group during wearing face mask were much more than those of normal group. 4. Growth changes of maxilla in the treatment group after treatment of face mask were less than those of normal group. From the obtained aata, it can be concluded that there was a stimulative effect on forward growth of maxilla during the use of face mask ; however, on removal of face mask, the stimulative effect was eliminated and undergrowth tendency of maxilla resumed.

  • PDF

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

Verification of the Protective Effect of Functional Shielding Cream for the Prevention of X-ray Low-dose Exposure (X-ray 저선량 피폭방지를 위한 기능성 차폐크림의 방어 효과 검증)

  • Seon-Chil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.497-506
    • /
    • 2023
  • In the case of radiation workers in medical institutions, radiation exposure is made for patient protection and accurate procedures, so they have a problem of low dose exposure. Low-dose radiation exposure occurs mainly in parts of the body other than the Apron area, and the most frequent place is the skin of the back of the hand. In particular, since the medical personnel's hands require senses and fine movements during the procedure, they are defenseless in the radiation exposure area and are at risk of exposure. It can solve the problem of shielding such as lead gloves, and it is difficult to use by suggesting the activity of the hand during the procedure. To solve this problem, a shielding cream capable of obtaining a functional radiation protection effect was developed and its shielding performance was compared with lead equivalent of 0.1 mmPb. In the process of manufacturing shielding cream, the shielding performance was improved by adding a defoaming process to reduce air holes to increase the density of the cream. Therefore, the shielding cream using barium sulfate as the main material has a lower shielding rate than the lead plate, and in the realm of effective energy, it is 59%, At high effective energy, a difference of about 37% was shown, indicating that there is a functional radiation protection effect. The advantage is that it can be used directly on the skin, and it is considered that it can be used before wearing surgical gloves and has a permanent protective effect.

The Effect of Prism Adaptation Following Traumatic Brain Injury: A case report

  • Jeong, Eun-Hwa;Min, Yoo-Seon
    • Therapeutic Science for Rehabilitation
    • /
    • v.6 no.2
    • /
    • pp.37-45
    • /
    • 2017
  • Background: The presence of visuospatial impairment can make patients slow functional recovery and impede the rehabilitation process in TBI patients. Objective: The aim of this study is to investigate effects of prism adaptation treatment for functional outcomes in patients following traumatic brain injury. Methods: The subject received prism adaptation treatment for 2 weeks additionally during traditional rehabilitation for 4 weeks. The Patient has prism adaptation treatment while wearing wedge prisms that shift the external environment about $12^{\circ}$ leftward. The patient received 10 sessions, 15-20min each session. Outcome measures were visuospatial deficit(line bisection, latter cancellation), Visual and spatial perception(LOTCA-visual perception and spatial perception), motor function of upper extremity(FMA U/E; Fugl-Meyer motor assessment upper extremity, ARAT; Action research arm test), balance(BBS; Berg Balance Scale), mobility(FAC; Functional ambulation classification) and functional level(FIM; Functional independent measure). All Assessments took place on study entry and post-treatment assessments were performed at discharge from the hospital. Results: After prism adaptation, the visuospatial impairment scores improved as indicated in the line bisection(-15.2 to -6.02), latter cancellation(2 to 0) and LOTCA- spatial perception scores(7 to 9). The upper motor function improved as indicated in the scores of affected FMA U/E(21 to 40) and ARAT(4 to 22). Ambulation and balance improved as indicated in the BBS scores(25 to 38) and FAC scores(0 to 4). ADL function improved as indicated in the FIM total scores 54 to 70(motor 34 to 61, cognition 20 to 29). Conclusion: Prism adaptation did improve functional level such as motor functions and ADL abilities in TBI patient. Further research is recommended.

A Preliminary Study of MPEG-V Scent effects on Virtual Reality Content (가상현실 콘텐츠 용 MPEG-V 후각효과 기초 연구)

  • Lim, Yong-Chul;Kim, Sang-Kyun;Lee, YoungMi
    • Journal of Broadcast Engineering
    • /
    • v.22 no.5
    • /
    • pp.589-599
    • /
    • 2017
  • This paper introduces a system to reproduce the olfactory effect using the MPEG-V (ISO / IEC 23005) standard to verify the reliability of the fragrance used in the olfactory experiment Using the implemented system, with experiment participant wearing HMD(Head Mounted Display), we carried out one-to-one matching of aroma and scent object images, matching images of aroma and many scent objects, matching of aroma and fragrance object images, and analyzing distance preference. The results of the experiment showed that aroma of coffee, cocoa, banana, and peach aroma is suitable scent for testing. In case of coffee aroma with high matching accuracy, 10 ~ 20cm distance between smell and participant was more effective in image matching than 30cm. In the future, we can conduct the olfactory research for enhancing the sense of immersion and presence of virtual reality contents using the selected fragrance.

Effects for Running Shoes with Resilience of Midsole on Biomechanical Properties (미드솔의 반발탄성이 러닝화의 생체역학적 특성에 미치는 영향)

  • Yoo, Chan-Il;Won, Yonggwan;Kim, Jung-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.103-111
    • /
    • 2015
  • Objective : The purpose of this study was to evaluate the effect for running shoes with resilience of midsole on biomechanical properties. Methods : 10 healthy males who had no history of injury in the lower extremity with an average age of 26.5 year(SD=1.84), height of 172.22 cm(SD=4.44) and weight of 67.51 kg(SD=6.17) participated in this study. All subjects ran on the treadmill wearing three different running shoes. Foot pressure data was collected using Pedar-X system(Novel Gmbh, Germany) operating at 100 Hz. Surface EMG signals for biceps femoris, rectus femoris, vastus lateralis, medial lateralis, tibialis anterior, medial gastrocnemius, soleus and peroneus longus were acquired at 1000 Hz using Bignoli 8 System(Delsys Inc., USA). To normalize the difference of the magnitude of muscle contractions, it was expressed as a percentage relative to the maximum voluntary contraction (MVC). The impact resilience of the midsole data was collected using Fastcam SA5 system(Photron Inc., USA). Collected data was analyzed using One-way ANOVA in order to investigate the effects of each running shoes. Results : TPU midsole was significantly wider in contact area than EVA, TPE midsole in midfoot and higher in EMG activity than EVA midsole at biceps femoris. TPE midsole was significantly wider in contact area than EVA midsole in rearfoot and higher in peak pressure than EVA midsole in forefoot. EVA midsole was significantly higher in EMG activity than TPU midsole at tibia anterior. In medial resilience of midsoles, TPE midsole was significantly higher than EVA, TPU midsole. Conclusion : TPU midsole can reduce the load on the midfoot effectively and activate tibialis anterior, biceps femoris to give help to running.

An Evaluation of Factors Influencing the Thermal Insulation and Evaporative Resistance of a Waterproof and Breathable Garment System (투습방수의류의 보온력 및 증발저항 평가와 관련 변인)

  • Shim, Huen sup
    • The Korean Journal of Community Living Science
    • /
    • v.25 no.4
    • /
    • pp.549-556
    • /
    • 2014
  • This study evaluates the thermal insulation and evaporative resistance of a waterproof and breathable garment system and determines the factors influencing its thermal performance. The experimental garments were composed of underwear (shirts with 100% wool and 100% polyester) and outerwear (jackets and pants with a vapor-permeable membrane and a vapor-impermeable membrane). Data on clothing insulation in a dry condition ($10^{\circ}C$) and a wet condition ($10^{\circ}C$, 40% R.H.), evaporative resistance ($34^{\circ}C$, 40% R.H., and $10^{\circ}C$, 40% R.H.), and microclimate vapor pressure were collected and analyzed. According to the results, the thermal insulation of the experimental garment system ranged 1.27~1.40 in the dry condition and 0.40~0.89 in the wet condition at $10^{\circ}C$. Evaporative resistance ranged $41{\sim}525m^2Pa/W$. A decrease in thermal insulation by wetting underwear ranged 31~67% in the cold condition ($10^{\circ}C$). The breathability of the outer garment influenced the decrease in thermal insulation by wetting. The type of underwear fiber influenced the decrease in thermal insulation only when it was used with breathable outerwear. The vapor-permeable outerwear sample with polyester underwear (P_Perm) showed a larger decrease in insulation than that with wool (W_Perm). The evaporative resistance of the vapor-permeable ensemble showed no effect of underwear in the warm condition ($34^{\circ}C$), but polyester underwear showed lower evaporative resistance than wool in the cold condition ($10^{\circ}C$). The vapor-impermeable ensemble showed no difference in evaporative resistance between polyester underwear and wool underwear in both conditions. Future research should consider various clothing ensemble combinations and environmental conditions and evaluate wear comfort by using human subjects.

Immediate Effects of Abdominal Pressure Belt on Limited of Stability and Gait Parameter in Patients after Chronic Stroke: one-group pretest-posttest design (복부압박벨트가 만성 뇌졸중 환자의 균형 및 보행에 즉각적으로 미치는 융복합적 영향)

  • Park, Shin-Jun;Cho, Kyun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.63-69
    • /
    • 2020
  • This study was conducted to investigate the immediate effects of abdominal pressure blet on limited of stability and gait parameter in patients after stroke. Thirty stroke patients were recruited to measured pre and post wearing the abdominal pressure belt. The assessment measured limited of stability and spatiotemporal gait parameter. This study result were significantly increase in paretic side area, non-paretic side area, forward side area, backward side area (p<.05) and cadence, gait velocity, stride length (p<.05). This study found that abdominal pressure belt had an immediate effect on improving balance and gait function in stroke patients. Future studies require studies of efficient abdominal pressure levels and intervention periods to improve the balance and walking function of stroke patient.

The Effect of Wheelchair Propulsion on Carpal Tunnel Syndrome of Wrist Joint

  • Kong, Jin-Yong;Kwon, Hyuk-Cheol;Chang, Ki-Yeon;Jeong, Dong-Hoon
    • Physical Therapy Korea
    • /
    • v.11 no.4
    • /
    • pp.7-17
    • /
    • 2004
  • Individuals who propel wheelchairs have a high prevalence of upper extremity injuries (i.e., carpal tunnel syndrome, elbow/shoulder tendonitis, impingement syndrome). Musculoskeletal injuries can result from overuse or incorrect use of manual wheelchairs, and can hinder rehabilitation efforts. To better understand the mechanisms of upper extremity injuries, this study investigates the motion of the wrist during wheelchair propulsion. This study also examines changes in the variables that occur with fatiguing wheelchair propulsion to determine how the time parameters of wheelchair propulsion and the state of fatigue influence the risk of injury. A two dimensional (2-D) analysis of wrist movement during the wheelchair stroke was performed. Twenty subjects propelled a wheelchair handrim on a motor-driven treadmill at two different velocities (50, 70 m/min). The results of this study were as follows; The difference in time parameters of wheelchair propulsion (cadence, cycle time, push time, recovery time, and PSP ratio) at two different velocities was statistically significant. The wrist kinematic characteristics had statistically significant differences at two different velocities, but wrist radial deviation and elbow flexion/extension had no statistically significant differences. There were statistically significant differences in relation to fatigue in the time parameter of wheelchair propulsion (70 m/min) between initial 1 minute and final 1 minute. The wrist kinematic characteristics between the initial 1 minute and final 1 minute in relation to fatigue had statistically significant differences but the wrist flexion-extension (50 m/min) had no statistically significant differences. According to the results, the risk of musculoskeletal injuries is increased by fatigue from wheelchair propulsion. To prevent musculoskeletal injuries, wheelchair users should train in a muscle endurance program and consider wearing a splinting/grove. Moreover, wheelchair users need education on propulsion posture, suitable joint position, and proper recovery patterns of propulsion.

  • PDF

Influences of Mobile Phone Electromagnetic Wave on Human Body According to Holding Method by the Hand and Wearing Accessories (손과 액세서리에 의한 휴대폰 전자파의 인체 노출 특성)

  • Choi Myung-Sun;Jang Young-Ho;Gimm Youn-Myoung;Park Han-Kyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.652-660
    • /
    • 2005
  • In this paper, we compared the spatial peak SAR values measured with and without holding the hand-held phones to check the present recommended spatial peak SAR. To better understand the analysis of the SAR effect values, SAR is measured with hand phantoms, made and recommended for the use of Bar-type and Folder-type hand-held phones. The measured results have shown that use of the hand considerably reduces the spatial peak SAR value in a head phantom. We compared the spatial peak SAR values measured with and without accessories. To better understand the analysis of the effects of SAR values with accessories, SAR is measured with accessories composed of three kinds of earrings and glasses. The measured results proved in study that the spatial peak SAR value in a head phantom is not affected by the earrings but by the glasses. The glasses considerably increases the spatial peak SAR value in a head phantom while using Bar-type phones, although the effects are modest with Folder-type phones.