• 제목/요약/키워드: Wearable Systems

검색결과 281건 처리시간 0.027초

웨어러블 테크놀로지를 적용한 융합 패션디자인 개발 연구 -빛과 형태변화 표현을 중심으로- (A Study on Convergence Fashion Design Applied Wearable Technology -Focused on the Expression of the Light and Transformation-)

  • 이현승;이재정
    • 한국의류학회지
    • /
    • 제41권4호
    • /
    • pp.709-721
    • /
    • 2017
  • This study researches the application methods of Wearable Technology (WT) realizing the convergence of Design and Electronics that could broaden the fashion expression boundaries to correspond to current convergence trends. For this, students in the Department of Fashion design and the Department of Electronics conducted an oriented convergence-design-workshop. The initial step of the workshop, included a lecture on WT including existing cases and brainstorming. As a result, two types of concepts; 'Light' using the lighting technology and 'Complex' using transforming and lighting technologies together were generated. Designers created garments that did not externally expose digital devices and engineers then configured basic systems with the minimum size of the devices applying. At the development stage, designers constructed internal structures of garments which do not influence the comfort situation and activities of those wearing the garments. Engineers then adjusted and finished the fashion prototypes' whole WT systems drawing on designers' guidelines. As the result of this study's workshop, the fashion prototypes were extracted by collaboration according to WT concepts; therefore, there could be the promising potential to broaden fashion expression boundaries through the application of WT.

A Robust Wearable u-Healthcare Platform in Wireless Sensor Network

  • Lee, Seung-Chul;Chung, Wan-Young
    • Journal of Communications and Networks
    • /
    • 제16권4호
    • /
    • pp.465-474
    • /
    • 2014
  • Wireless sensor network (WSN) is considered to be one of the most important research fields for ubiquitous healthcare (u-healthcare) applications. Healthcare systems combined with WSNs have only been introduced by several pioneering researchers. However, most researchers collect physiological data from medical nodes located at static locations and transmit them within a limited communication range between a base station and the medical nodes. In these healthcare systems, the network link can be easily broken owing to the movement of the object nodes. To overcome this issue, in this study, the fast link exchange minimum cost forwarding (FLE-MCF) routing protocol is proposed. This protocol allows real-time multi-hop communication in a healthcare system based on WSN. The protocol is designed for a multi-hop sensor network to rapidly restore the network link when it is broken. The performance of the proposed FLE-MCF protocol is compared with that of a modified minimum cost forwarding (MMCF) protocol. The FLE-MCF protocol shows a good packet delivery rate from/to a fast moving object in a WSN. The designed wearable platform utilizes an adaptive linear prediction filter to reduce the motion artifacts in the original electrocardiogram (ECG) signal. Two filter algorithms used for baseline drift removal are evaluated to check whether real-time execution is possible on our wearable platform. The experiment results shows that the ECG signal filtered by adaptive linear prediction filter recovers from the distorted ECG signal efficiently.

상지 근력지원용 웨어러블 로봇을 위한 명령신호 생성 기법 개발 (Development of Command Signal Generating Method for Assistive Wearable Robot of the Human Upper Extremity)

  • 이희돈;유승남;이승훈;장재호;한정수;한창수
    • 제어로봇시스템학회논문지
    • /
    • 제15권2호
    • /
    • pp.176-183
    • /
    • 2009
  • This paper proposes command signal generating method for a wearable robot using the force as the input signal. The basic concept of this system pursues the combination of the natural and sophisticated intelligence of human with the powerful motion capability of the robot. We define a task for the command signal generation to operate with the human body simultaneously, paying attention to comfort and ease of wear. In this study, we suggest a basic exoskeleton experimental system to evaluate a HRI(Human Robot Interface), selecting interfaces of arm braces on both wrists and a weight harness on the torso to connect the robot and human. We develop the HRI to provide a command for the robot motion. It connects between the human and the robot with the multi-axis load-cell, and it measures the relative force between the human and the robot. The control system calculates the trajectory of end-effector using this force signal. In this paper, we verify the performance of proposed system through the motion of elbow E/F(Extension/Flexion), the shoulder E/F and the shoulder Ab/Ad (Abduction/Adduction).

Development of an oneM2M-compliant IoT Platform for Wearable Data Collection

  • Ahn, Il Yeup;Sung, Nak-Myoung;Lim, Jae-Hyun;Seo, Jeongwook;Yun, Il Dong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권1호
    • /
    • pp.1-15
    • /
    • 2019
  • Internet of Things (IoT) is commonly referred to as a future internet technology to provide advanced services by interconnecting physical and virtual things, collecting and using many data from them. The IoT platform is a server platform with a common architecture to collect and share the data independent of the IoT devices and services. Recently, oneM2M, the global standards initiative for Machine-to-Machine (M2M) communications and the IoT announced the availability of oneM2M Release 2 specifications. Accordingly, this paper presents a new oneM2M-compliant IoT platform called Mobius 2.0 and proposes its application to collect the biosignal data from wearable IoT devices for emotion recognition. Experimental results show that we can collect various biosignal data seamlessly and extract meaningful features from the biosignal data to recognize two emotions of joy and sadness.

Reliability of joint angle during sit-to-stand movements in persons with stroke using portable gait analysis system based wearable sensors

  • An, Jung-Ae;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권3호
    • /
    • pp.146-151
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the test-retest reliability and concurrent validity of the joint angle of the lower extremities during sit-to-stand movements with wearable sensors based on a portable gait analysis system (PGAS), and the results were compared with a analysis system (MAS) to predict the clinical potential of it. Design: Cross-sectional study. Methods: Sixteen persons with stroke (9 males, 7 females) participated in this study. All subjects had the MAS and designed PGS applied simultaneously and eight sensor units of designed PGAS were placed in a position to avoid overlap with the reflexive markers from MAS. The initial position of the subjects was 90º of hip, knee, and ankle joint flexion while sitting on a chair that was armless and backless. The height of the chair was adjusted to each individual. After each trial, the test administrator checked the quality of data from both systems that measured sit-to-stand for test-retest reliability and concurrent validity. Results: As a result, wearable sensor based designed PGAS and MAS demonstrated reasonable test-retest reliability for the assessment of joint angle in the lower extremities during sit-to-stand performance. The intra-class correlation coefficients (ICCs) for wearable sensor based designed PGAS showed an acceptable test-retest reliability, with ICCs ranging from 0.759 to 0.959. In contrast, the MAS showed good to excellent test-retest reliability, with ICCS ranging from 0.811 to 0.950. In concurrent validity, a significant positive relationship was observed between PGAS and MAS for variation of joint angle during sit-to-stand movements (p<0.01). A moderate to high relationship was found in the affected hip (r=0.665), unaffected hip (r=0.767), affected knee (r=0.876), unaffected knee (r=0.886), affected ankle (r=0.943) and unaffected ankle (r=0.823) respectively. Conclusions: The results of this study indicated that wearable sensor based designed PGAS showed acceptable test-retest reliability and concurrent validity in persons with stroke for sit-to-stand movements and wearable sensors based on developed PGAS may be a useful tool for clinical assessment of functional movement.

Identification of Demand Type Differences and Their Impact on Consumer Behavior: A Case Study Based on Smart Wearable Product Design

  • Jialei Ye;Xiaoyou He;Ziyang Liu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제18권4호
    • /
    • pp.1101-1121
    • /
    • 2024
  • Thorough understanding of user demands and formulation of product development strategies are crucial in product design, and can effectively stimulate consumer behavior. Scientific categorization and classification of demands contribute to accurate design development, design efficiency, and success rates. In recent years, e-commerce has become important consumption platforms for smart wearable products. However, there are few studies on product design and development among those related to promoting platform product services and sales. Meanwhile, design strategies focusing on real consumer needs are scarce among smart wearable product design studies. Therefore, an empirical consumer demand analysis method is proposed and design development strategies are formulated based on a categorized interpretation of demands. Using representative smart bracelets from wearable smart products as a case, this paper classifies consumer demands with three methods: big data semantic analysis, KANO model analysis, and satisfaction analysis. The results reveal that analysis methods proposed herein can effectively classify consumer demands and confirm that differences in consumer demand categories have varying impacts on consumer behavior. On this basis, corresponding design strategies are proposed based on four categories of consumer demands, aiming to make product design the leading factor and promote consumer behavior on e-commerce platforms. This research further enriches demand research on smart wearable products on e-commerce platforms, and optimizes products from a design perspective, thereby promoting consumption. In future research, different data analysis methods will be tried to compare and analyze changes in consumer demands and influencing factors, thus improving research on impact factors of product design in e-commerce.

Heart Rate Variability Analysis for Significance Between Ag/AgCl Electrode and Electric Textile Sensor in Wearable Condition

  • Shin, Hang-Sik;Lee, Chung-Keun;Yun, Yong-Hyeon;Lee, Myoung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.453-456
    • /
    • 2005
  • Significance verification of electric fabric compared with existing electrode is very useful for the wearable and ubiquitous healthcare. In this paper, we verified the significance between Ag/AgCl electrode and electric fabric in dry-normal condition through heart rate variability analysis. We can find 98 % or more similarity about low frequency and high frequency which is important parameter for the heart rate variability analysis between two different electrodes in experiment. From this result, we confirmed that the power spectral density of low frequency, high frequency component from the electric fabric has high similarity compared with the result of heart rate variability from Ag/AgCl electrode in dry-normal condition.

  • PDF

Development of compact wireless communication module for auto-recognition wearable I/O device by using USB interface

  • Park, Kwanghyun;Jeon, Jae-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.37.5-37
    • /
    • 2002
  • $\textbullet$ Wearable I/O Devices relieve the restriction of working space to the worker. $\textbullet$ And They permit very active work achievement to the worker. $\textbullet$ But, current Wearable I/O Devices still have some controversial points. $\textbullet$ The worker needs serie system operations to wear and take off devices. $\textbullet$ Also, it is not easy to change any device which is currently used when the worker uses some devices. $\textbullet$ So, we propose the Compact Wireless Communication Module to solve these problem. $\textbullet$ For that purpose, we implemented the proposed module, and proved the efficiency and convenience.

  • PDF

Triboelectric Nanogenerators for Self-powered Sensors

  • Rubab, Najaf;Kim, Sang-Woo
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.79-84
    • /
    • 2022
  • Self-powered sensors play an important role in everyday life, and they cover a wide range of topics. These sensors are meant to measure the amount of relevant motion and transform the biomechanical activities into electrical signals using triboelectric nanogenerators (TENGs) since they are sensitive to external stimuli such as pressure, temperature, wetness, and motion. The present advancement of TENGs-based self-powered wearable, implantable, and patchable sensors for healthcare monitoring, human body motion, and medication delivery systems was carefully emphasized in this study. The use of TENG technology to generate electrical energy in real-time using self-powered sensors has been the topic of considerable research among various leading scholars. TENGs have been used in a variety of applications, including biomedical and healthcare physical sensors, wearable devices, biomedical, human-machine interface, chemical and environmental monitoring, smart traffic, smart cities, robotics, and fiber and fabric sensors, among others, as efficient mechanical-to-electric energy conversion technologies. In this evaluation, the progress accomplished by TENG in several areas is extensively reviewed. There will be a discussion on the future of self-powered sensors.

웨어러블 센서를 활용한 경량 인공신경망 기반 손동작 인식기술 (A Light-weight ANN-based Hand Motion Recognition Using a Wearable Sensor)

  • 이형규
    • 대한임베디드공학회논문지
    • /
    • 제17권4호
    • /
    • pp.229-237
    • /
    • 2022
  • Motion recognition is very useful for implementing an intuitive HMI (Human-Machine Interface). In particular, hands are the body parts that can move most precisely with relatively small portion of energy. Thus hand motion has been used as an efficient communication interface with other persons or machines. In this paper, we design and implement a light-weight ANN (Artificial Neural Network)-based hand motion recognition using a state-of-the-art flex sensor. The proposed design consists of data collection from a wearable flex sensor, preprocessing filters, and a light-weight NN (Neural Network) classifier. For verifying the performance and functionality of the proposed design, we implement it on a low-end embedded device. Finally, our experiments and prototype implementation demonstrate that the accuracy of the proposed hand motion recognition achieves up to 98.7%.