• Title/Summary/Keyword: Wearable Robot

Search Result 129, Processing Time 0.035 seconds

Redundant Design of Wearable Robot Mechanism for Upper Arm (여자유도를 이용한 상지 착용형 로봇의 메커니즘 설계)

  • Lee, Young-Su;Hong, Sung-Jun;Jang, Hye-Yeon;Jang, Jae-Ho;Han, Chang-Su;Han, Jung-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.134-141
    • /
    • 2009
  • Recently, many researchers have tried to develop wearable robots for various fields such as medical and military purposes. We have been studying robotic exoskeletons to assist the motion of persons who have problems with their muscle function in daily activities and rehabilitation. The upper-limb motions (shoulder, elbow and wrist motion) are especially important for such persons to perform daily activities. Generally for shoulder motion 300F is needed to describe its motion(extension/flexion, abduction/adduction, internal/external rotation) but we have used a redundant actuator thus making a 4 DOF system. In this paper, we proposed the mechanism design of the exoskeleton which consists of 4-DOF for shoulder and 1-DOF for elbow robotic exoskeleton to assist upper-limb motion. Then we compared the new mechanism design and prototype mechanism design. Here we also analyze the proposed system kinematically to find out and to avoid the singular point. This research will ensure that the proposed wearable robot system make human's motion more powerfully and more easily.

Effect of Robot-Assisted Wearable Exoskeleton on Gait Speed of Post-Stroke Patients: A Systematic Review and Meta-Analysis of a Randomized Controlled Trials

  • Chankyu Kim;Hyun-Joong Kim
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.471-477
    • /
    • 2022
  • Objective: The greatest motor impairment after stroke is a decreased ability to walk. Most stroke patients achieve independent gait, but approximately 70% do not reach normal speed, making it difficult to reach a standard of daily living. Therefore, a wearable exoskeleton is recommended for optimal independent gait because different residual disorders hinder motor function after stroke. This review synthesized the effect on gait speed in randomized controlled trials (RCTs) in which gait training using a wearable exoskeleton was performed on post-stroke patients for qualitative and quantitative analysis. Design: A systematic review and meta-analysis of a randomized controlled trials Methods: RCTs using wearable exoskeletons in robotic rehabilitation of post-stroke patients were extracted from an international electronic database. For quality assessment and quantitative analysis, RevMan 5.4 was used. Quantitative analysis was calculated as the standardized mean difference (SMD) and presented as a random effect model. Results: Five studies involving 197 post-stroke patients were included in this review. As a result of the analysis using a random effect model, gait training using a wearable exoskeleton in post-stroke patients showed a significant improvement in gait speed compared to the non-wearing exoskeleton (SMD=1.15, 95% confidence interval: 0.52 to 1.78). Conclusions: This study concluded that a wearable exoskeleton was more effective than conventional gait training in improving the gait speed in post-stroke patients.

Chattering Free Sliding Mode Control of Upper-limb Rehabilitation Robot with Handling Subject and Model Uncertainties (환자와 로봇의 모델 불확도를 고려한 상지재활로봇의 채터링 없는 슬라이딩 모드 제어)

  • Khan, Abdul Manan;Yun, Deok-Won;Han, Changsoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.5
    • /
    • pp.421-426
    • /
    • 2015
  • Need to develop human body's posture supervised robots, gave the push to researchers to think over dexterous design of exoskeleton robots. It requires to develop quantitative techniques to assess human motor function and generate the command to assist in compliance with complex human motion. Upper limb rehabilitation robots, are one of those robots. These robots are used for the rehabilitation of patients having movement disorder due to spinal or brain injuries. One aspect that must be fulfilled by these robots, is to cope with uncertainties due to different patients, without significantly degrading the performance. In this paper, we propose chattering free sliding mode control technique for this purpose. This control technique is not only able to handle matched uncertainties due to different patients but also for unmatched as well. Using this technique, patients feel active assistance as they deviate from the desired trajectory. Proposed methodology is implemented on seven degrees of freedom (DOF) upper limb rehabilitation robot. In this robot, shoulder and elbow joints are powered by electric motors while rest of the joints are kept passive. Due to these active joints, robot is able to move in sagittal plane only while abduction and adduction motion in shoulder joint is kept passive. Exoskeleton performance is evaluated experimentally by a neurologically intact subjects while varying the mass properties. Results show effectiveness of proposed control methodology for the given scenario even having 20 % uncertain parameters in system modeling.

A Study on the Controller Design of 3D Printed Robot Hand using TPU Material (TPU 소재를 이용한 3D 프린팅 로봇 손의 제어기 설계에 관한 연구)

  • Young-Rim Choi;Ye-Eun Park;Jong-Wook Kim;Sunhee Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.2
    • /
    • pp.312-327
    • /
    • 2024
  • In this study, a rehabilitation 3D printed wearable device was developed by combining an assembly-type robot hand and an integral-type robot hand through fused deposition 3D printing manufacturing with various hardness TPU (Thermoplastic Polyurethane) filaments. The hardware configuration of the robot hand includes a controller designed with four motors, one small servo motor, and a circuit board. In the case of the assembly-type robot hand model, a 3D printed robot hand was assembled using samples printed with TPU of hardness 87A and 95A. It was observed that TPU with a hardness of 95A was suitable for use due to shape stability. For the integrated-type robot hand model, the external sample using TPU of hardness 95A could be modified through a cutting method, and the hardware configuration is the same as the assembly-type. The system structure of the 3D printed robot hand was improved from an individual control method to a simultaneous transmission method.Furthermore, the system architecture of an integrated 3D printed robotic hand rehabilitation device and the application of the rehabilitation device were developed.

Autonomous Mobile Robot Control using the Wearable Devices Based on EMG Signal for detecting fire (EMG 신호 기반의 웨어러블 기기를 통한 화재감지 자율 주행 로봇 제어)

  • Kim, Jin-Woo;Lee, Woo-Young;Yu, Je-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.3
    • /
    • pp.176-181
    • /
    • 2016
  • In this paper, the autonomous mobile robot control system for detecting fire was proposed using the wearable device based on EMG(Electromyogram) signal. Myo armband is used for detecting the user's EMG signal. The gesture was classified after sending the data of EMG signal to a computer using Bluetooth communication. Then the robot named 'uBrain' was implemented to move by received data from Bluetooth communication in our experiment. 'Move front', 'Turn right', 'Turn left', and 'Stop' are controllable commands for the robot. And if the robot cannot receive the Bluetooth signal from a user or if a user wants to change manual mode to autonomous mode, the robot was implemented to be in the autonomous mode. The robot flashes the LED when IR sensor detects the fire during moving.

Design of Assistive Wearable System for Walking (보행 보조 웨어러블 시스템 설계)

  • Choi, Seong-Dae;Lee, Sang-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.111-116
    • /
    • 2019
  • With the recent acceleration of industrial technologies and active research, wearable robot technologies have been applied to various fields. To study the utility of wearable robots, basic research on kinetic mechanisms of the human body, bio-signal analysis, and system control are essential. In this study, we investigated the basic structure of a wearable system and the operating principles of a driving mechanism. The control system and supporting structure, which comprise the driving mechanism, were designed and manufactured. Motion and load analyses were performed simultaneously for the design of the kinematic drive, and the driving mechanism was constructed by analyzing walking motion. The operating conditions of the cylinder were verified by stride via driving experiments. Further, the accuracy and responsiveness of the system were confirmed by comparison with actual motion, and the system safety was validated by applying loads.