Study on Fatigue Property of Material for Oil Hydraulic Piston Pump (유압 피스톤 펌프 소재의 피로특성 연구)

  • Kim, Nam-Seok;Nam, Ki-Woo;Kim, Hyun-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.555-559
    • /
    • 2011
  • Oil hydraulic piston pumps are extensively used worldwide because of their simple design, light weight, and cost effectiveness. However, an oil hydraulic pump is likely to have high leakage, friction, and low energy efficiency after long-term use. In oil hydraulic piston pumps the clearance between the valve block and the piston plays an important role in the volumetric and overall efficiency. We studied the wear property of the SACM645 material used in hydraulic piston pumps via experiments with different heat treatments. We prepared three different specimens. The maximum tensile strengths of the QT and QT-nitration specimens are similar (about 820 MPa), but the strains are significantly different. However, the fatigue characteristic depended on the heat treatment.

A Study on Image Quality and Exposure Dose of Hard-radiation Radiography of the Chest (흉부(胸部) 경선질촬영(硬線質撮影)에 있어서 피폭선양(被曝線量)의 저감(低減)에 관(關)한 연구(硏究))

  • Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakurai, Tatsuya;Kim, Chung-Woon;Hwang, Jong-Sun
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.15-21
    • /
    • 1991
  • Experiment was conducted on the image quality and exposure dose following replacement of $CaWO_4$ system screen BH-III and BX-III which have so far been used for high-voltage hard-radiation quality radiography, with rare earth system screen KO750, combined with high contrast film SRH, while additional filter was altered, Cu 0.8 mm+Al 1.4 mm(HVL : Al 8.8 mm), Cu 1.3 mm+Al 1.0 mm(HVL : Al 10.6 mm) and Cu 1.8 mm+Al 1.5 mm(HVL : Al 11.4 mm). AS a result, visual evaluation did not detect extreme changes in image quality under the respective condition(HVL : $Al\;8.8\;mm{\sim}Al\;11.4\;mm$). It was noted, however, that surface exposure dose declined with an increase in the thickness of the additional filter, as it was $18.9\;{\mu}Gy$ at HVL Al 8.8 mm, $17.5\;{\mu}Gy$ at Al 10.6 mm and $15.7\;{\mu}Gy$ at Al 11.4 mm. Considering the limited rating of X-ray equipment and wear of machinery, however, the range of $Cu\;1.3\;mm{\sim}1.8\;mm+Al\;1.0\;mm{\sim}1.5\;mm(1/16\;VL{\sim}1/32\;VL)$ seemed to be a limit.

  • PDF

Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

  • Yoon, Ki-Joon;Park, Young-Bum;Choi, Hyunmin;Cho, Youngsung;Lee, Jae-Hoon;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.465-471
    • /
    • 2016
  • PURPOSE. The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of $1.0{\times}10^6$cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.

Automatic Pattern Setting System Reacting to Customer Design

  • Yuan, Ying;Huh, Jun-Ho
    • Journal of Information Processing Systems
    • /
    • v.15 no.6
    • /
    • pp.1277-1295
    • /
    • 2019
  • With its technical development, digital printing is being universally introduced to the mass production of clothing factories. At the same time, many fashion platforms have been made for customers' participation using digital printing, and a tool is provided in platforms for customers to make designs. However, there is no sufficient solution in the production stage for automatically converting a customer's design into a file before printing other than designating a square area for the pattern designed by the customer. That is, if 30 different designs come in from customers for one shirt, designers have to do the work of reproducing the design on the clothing pattern in the same location and in the same angle, and this work requires a great deal of manpower. Therefore, it is necessary to develop a technology which can let the customer make the design and, at the same time, reflect it in the clothing pattern. This is defined in relation to the existing clothing pattern with digital printing. This study yields a clothing pattern for digital printing which reflects a customer's design in real time by matching the diagram area where a customer designs on a given clothing model and the area where a standard pattern reflects the customer's actual design information. Designers can substitute the complex mapping operation of programmers with a simple area-matching operation. As there is no limit to clothing designs, the variousfashion design creations of designers and the diverse customizing demands of customers can be satisfied at low cost with high efficiency. This is not restricted to T-shirts or eco-bags but can be applied to all woven wear, including men's, women's, and children's clothing, except knitwear.

Characteristics of Coating Films on Hot-Dipped Aluminized Steel Formed by Plasma Electrolytic Oxidation Process at Different Current Densities (PEO 전류밀도 조건에 따른 알루미늄도금 강재상 산화코팅막의 특성)

  • Choi, In-Hye;Lee, Hoon-Seung;Lee, Myeong-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.50 no.5
    • /
    • pp.366-372
    • /
    • 2017
  • Plasma electrolytic oxidation(PEO) has attracted attention as a surface treatment which has high wear resistance and corrosion resistance. PEO is generally considered as cost-effective, environmentally friendly and superior in terms of coating performance. Most of studies about the PEO processes have been applied to light metals such as Al and Mg. Because the strength of Al and Mg is weaker than that of steel, there is a limit to the application. In this study, PEO process was used to form oxide coatings on Hot dipped aluminized(HDA) steel and the characteristics of the coating film according to the PEO current density were studied. The morphology was observed by SEM and component was analyzed by using EDS. The corrosion behaviors of PEO coating films were estimated by exposing salt spray test at 5 wt.% NaCl solution and measuring polarization curves in deaerated 3 wt.% NaCl solution. With the increase of PEO process current density, the pore size of the coating surface and the thickness of coating increased. It was confirmed that no Fe component was present on the coating surface. PEO coating films obviously showed good corrosion resistance compared with HDA. It is considered that the PEO coating acts as a barrier to protect the base material from external factors causing corrosion.

A Study on the Dynamic Component of Cutting Force in Turning[1] -Recognition of Chip Flow by the Dynamic Cutting Force Component- (선삭가공에 있어서 절삭저항의 동적성분에 관한 연구 [I] -동적성분에 의한 Chip배출상태의 인식-)

  • Chung, Eui-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.5 no.1
    • /
    • pp.84-93
    • /
    • 1988
  • The on-line detection of the chip flow is one of the most important technologies in com- pletly automatic operation of machine tool, such as FMS and Unmanned Factories. This problem has been studied by many researchers, however, it is not solved as yet. For the recognition of chip flow in this study, the dynamic cutting force components due to the chip breaking were measured by dynamometer of piezo-electric type, and the frequency components of cutting force were also analyzed. From the measured results, the effect of cutting conditions and tool geometry on the dynamic cutting force component and chip formation were investigated in addition to the relationships between frequency of chip breaking (fB) and side serrated crack (fC) of chip. As a result, the following conclusions were obtaianed. 1) The chip formations have a large effect on the dynamic cutting force components. When chip breaking takes place, the dynamic cutting force component greatly increases, and the peridoic components appear, which correspond to maximum peak- frequency. 2) The crater wear of tool has a good effect on the chip control causing the chiup to be formed as upward-curl shape. In this case, the dymamic cutting force component greatly increases also 3) fB and fC of chip are closely corelated, and fC of chips has a large effect on the change of the situation of chip flow and dynamic cutting force component. 4) Under wide cutting conditions, the limit value (1.0 kgf) of dynamic cutting force component exists between the broken and continuous chips. Accordingly, this value is suitable for recognition of chip flow in on-line control of the cutting process.

  • PDF

Characterization of Summertime Aerosol Particles Collected at Subway Stations in Seoul, Korea Using Low-Z Particle Electron Probe X-ray Microanalysis

  • Kim, Bo-Wha;Jung, Hae-Jin;Song, Young-Chul;Lee, Mi-Jung;Kim, Hye-Kyeong;Kim, Jo-Chun;Sohn, Jong-Ryeul;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • A quantitative single particle analytical technique, denoted low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize particulate matters collected at two underground subway stations, Jegidong and Yangje stations, in Seoul, Korea. To clearly identify the source of the indoor aerosols in the subway stations, four sets of samples were collected at four different locations within the subway stations: in the tunnel; at the platform; near the ticket office; nearby outdoors. Aerosol samples collected on stages 2 and 3 ($D_p$: $10-2.5\;{\mu}m$ and $2.5-1.0\;{\mu}m$, respectively) in a 3-stage Dekati $PM_{10}$ impactor were investigated. Samples were collected during summertime in 2009. The major chemical species observed in the subway particle samples were Fe-containing, carbonaceous, and soil-derived particles, and secondary aerosols such as nitrates and sulfates. Among them, Fe-containing particles were the most popular. The tunnel samples contained 85-88% of Fe-containing particles, with the abundance of Fe-containing particles decreasing as the distances of sampling locations from the tunnel increased. The Fe-containing subway particles were generated mainly from mechanical wear and friction processes at rail-wheel-brake interfaces. Carbonaceous, soil-derived, and secondary nitrate and/or sulfate particles observed in the underground subway particles likely flowed in from the outdoor environment by human activities and the air-exchange between the subway system and the outdoors. In addition, since the platform screen doors (PSDs) limit air-mixing between the tunnel and the platform, samples collected at the platform at the Yangjae station (with PSDs) showed a marked decrease in the relative abundances of Fe-containing particles compared to the Jegidong station (without PSDs).

The Effect of Dynamic Balance on Cyber Motion Sickness of Full Immersion Virtual Reality (완전 몰입형 가상현실로 인한 사이버 멀미가 동적 균형에 미치는 영향)

  • Kim, Na-Eun;Kim, Yu-lim;Moon, Sang-cheol;Lee, Dong-hung;Lim, Ho-jeong;Jang, Eun-kyung;Hung, Ji-eun;Kang, Jong-ho
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.131-138
    • /
    • 2018
  • The purpose of the study was to explore whether the Cyber Motion sickness used VR causes a change in the dynamic balance and fall. For 39 people who voluntarily participated in this study, this study measured the motion sickness questionnaires, the heart rate and stability of limit test in BioRescue. The study used Samsung Gear VR and applied the games to the To the homeland. The game proceeded 20minutes. Although the value of the stability after a VR application is slightly reduced, it did not reach statistical significance. The motion sickness questionnaires increased, and it had a statistical significant impact. Also Heart rate increased and it had a statistically significant impact. A virtual reality game affect for getting motion sickness but it did not affect the dynamic balance. So, cyber motion sickness caused by virtual reality wear does not result in decreased balance and falls.

Field Study of Emission Characteristics of Ammonia and Hydrogen Sulfide by Pig Building Types (돈사 작업장 유형에 따른 암모니아와 황화수소의 실내농도 및 발생량에 관한 현장 조사)

  • Kim, Ki Youn;Park, Jae Beom;Kim, Chi-Nyon;Lee, Kyung Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.36-43
    • /
    • 2006
  • The principal aim of this field study was to determine the concentrations and emissions of gaseous contaminants such as ammonia and hydrogen sulfide in the different types of pig buildings in Korea and allow objective comparison between Korea and the other countries in terms of pig housing types. This field study was performed from May to June and from September to October in 2002. Pig buildings investigated in this research were selected in terms of three criteria; manure removal system, ventilation mode and growth stage of pig. Measurements of concentration and emission of ammonia and hydrogen sulfide in the pig buildings were done in 5 housing types and the visited farms were 15 sites per each housing type. Concentrations of ammonia and hydrogen sulfide were measured at three locations of the central alley in the pig building and emission rates of them were estimated by multiplying the average concentration($mg/m^3$) measured near the air outlet by the mean ventilation rate($m^3/h$) and expressed either per pig of liveweight 75kg(mg/h/pig) or per area($mg/h/m^2$). Concentrations of ammonia and hydrogen sulfide in the pig buildings were averaged to 7.5 ppm and 286.5 ppb and ranged from 0.8 to 21.4 ppm and from 45.8 to 1,235 ppb, respectively. The highest concentrations of ammonia and hydrogen sulfide were found in the mechanically ventilated buildings with slats; 12.1 ppm and 612.8 ppb, while the lowest concentrations of ammonia and hydrogen sulfide were found in the pig buildings with deep-litter bed system(2.2 ppm) and the naturally ventilated pig buildings with manure removal system by scraper(115.2 ppb), respectively(p<0.05). All the pig buildings were investigated not to exceed the threshold limit values(TLVs) of ammonia(25 ppm) and hydrogen sulfide(10 ppm). The mean emissions of ammonia and hydrogen sulfide per pig(75kg in terms of liveweight) and area($m^2$) from pig buildings were 250.2 mg/h/pig and 37.8 mg/h/pig and $336.3mg/h/m^2$ and $50.9mg/h/m^2$, respectively. The pig buildings with deep-litter bed system showed the lowest emissions of ammonia and hydrogen sulfide(p<0.05). However, the emissions of ammonia and hydrogen sulfide from the other pig buildings were not significantly different(p>0.05). Concentrations and emissions of ammonia and hydrogen sulfide were relatively higher in the pig buildings managed with deep-pit manure system with slats and mechanical ventilation mode than the different pig housing types. In order to prevent pig farm workers from adverse health effect caused by exposure to ammonia and hydrogen sulfide in pig buildings, they should wear the respirators during shift and be educated sustainably for the guideline related to occupational safety.

A Study on Hazards Assessment of Electrostatic Firing Explosion of Working Wears at LPG Stations in Korea (한국의 LPG 충전소에 있어서 작업복의 정전기에 의한 화재 및 폭발 위험성에 관한 연구)

  • Cho young doo;Koo Ja Hyeuk;Choi Kwang Seo;Seo Dae Won;Joung Jae Hee;Takeuchi Manabu
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.20-24
    • /
    • 2000
  • The electrostatic safety consciousness of safety manager were investigated through questionnaires sent to liquid petroleum gas stations in Korea. In addition, hazards of fire and explosion due to electrostatic on synthetic-polymer-wears and cotton-wears were estimated experimentally. The results of questionnaires indicate most workers wear their working clothes indiscreetly owing to lack of knowledge of preventing electrostatic hazards. The amounts of electrostatic charge generated in synthetic-polymer-wears were 1.79, 1.44 and 1.02 $\mu$C in winter, spring and autumn and summer, respectively. All these values exceed the limit of working wears of 0.60$\mu$C requested by Korea Standard(KS K-7807) for preventing electrostatic hazards, which means hazards may occur. While, the charge in cotton-wears were in the range of 0.42 to 0.52$\mu$C, which suggests that the cotton-wears investigated in this study have no problem of hazards. Therefore workers, visual and experiential education are necessary for elevating the standard of on electrostatics. It is also necessary to establish standards of wearing for preventing electrostatic hazards.

  • PDF