• Title/Summary/Keyword: Wear rate

Search Result 1,077, Processing Time 0.028 seconds

An application plan of NSWC-98/LE1 when predicting the reliability of mechanical components of design and development phase (체계 개발 단계별 기계 부품에 대한 신뢰도 예측 시 NSWC-98-LE1 적용 방안)

  • Kwon, Ki Sang;Park, Eun Sim;Cho, Cha Hyun;Lee, Dong Woo;Lee, Su Jung
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.35-43
    • /
    • 2008
  • Generally, in analysis of reliability of Design and Development Phase, reliability of electrical components is analyzed based on standards such as MIL-HDBK-217F, Bellcore Issue 4,5,6 by analyzing stress of architectural side (Power, Voltage, Current and quality level of components) of weapon system and stress of operational side (operational environment, operational temperature, Operational Profile). But the reliability of mechanical components is analyzed based on the data book of failure history of mechanical parts called NPRD-95(Nonelectronic Parts Reliability Data-95) without any analysis of above stress. However, even if it's the same mechanical parts, it might have different failure rate(fatigue, wear, corrosion) during operation depending on how weary(stress : pressure, vibration, temperature during operation) the parts are. Therefore, analyzing reliability using just data book can cause big difference in reliability instead of analyzing based upon stressfulness that parts might have, operational concept, and other various factors. Thus, This paper will guide the way of predicting reliability by organizing ways of predicting reliability for system organization and adopt ing NSWC-98/LE1(Naval Surface Warfare Center-98/LE1) for mechanical components.

  • PDF

Design a Portable Biomedical Signal Measuring System for U-Health (U-Health를 위한 휴대형 생체신호 측정 시스템 설계)

  • Lee, Han-Wook;Kim, Sung-Hoo;Jeong, Won-Geun;Lee, Ju-Won;Jang, Doo-Bong;Lee, Gun-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.2
    • /
    • pp.51-56
    • /
    • 2008
  • U-Health is abbreviated from ubiquitous Health. Its final aim is "to improve the quality of life. To realize it, it is needed to generalize IT infrastructure such as the development of information-technology and construction of network. It is guaranteed to get medical care benefits unconsciously every time and everywhere based on this system. In this study, the environment of unconscious measurement was set up through ultra-violet instead of the existing Probe to wear with finger to follow this. TFT-LCD was included into module for display. U-Healthcare focused on the minimization and portable characteristic through the designed Zigbee communication module. Handled healthcare device was developed based on the U-Healthcare.

  • PDF

Modeling of the Conditioning Process in Chemical Mechanical Polishing (컨디셔닝 공정의 수학적 모델링)

  • Chang, One-Moon;Park, Ki-Hyun;Lee, Hyun-Seop;Jung, Won-Duck;Park, Sung-Min;Park, Boum-Young;Seo, Heon-Deok;Kim, Hyoung-Jea;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.569-570
    • /
    • 2006
  • The conditioning process is very important process for the CMP (Chemical Mechaning Polishing). This process regenerates the roughness of the polishing pad during the CMP process, increases the MRR (Material Removal Rate) and gives us longer pad life so conditioning process is essential for the CMP, and conditioning process influences the polishing pad shape gradually. Conditining process is related to the Non-Uniformity. In This paper, Kinematic of the conditioning process and mathematic modeling of the pad wear is studied and result shows how the various parameters influence the pad shape and WIWNU[1]. Consequently through these parameter, optimal design of the conditioning process equipment is predicted.

  • PDF

Microstructure and Wear Resistance of Ti-Me-N (Me=V, Nb and Si) Nanofilms Prepared by Hybrid PVD (Hybrid PVD로 제조된 Ti-Me-N (Me=V, Si 및 Nb) 나노 박막의 미세구조와 마모특성)

  • Yang, Young-Hwan;Kwak, Kil-Ho;Lee, Sung-Min;Kim, Seong-Won;Kim, Hyung-Tae;Kim, Kyung-Ja;Lim, Dae-Soon;Oh, Yoon-Suk
    • Journal of Surface Science and Engineering
    • /
    • v.44 no.3
    • /
    • pp.95-104
    • /
    • 2011
  • Ti based nanocomposite films including V, Si and Nb (Ti-Me-N, Me=V, Si and Nb) were fabricated by hybrid physical vapor deposition (PVD) method consisting of unbalanced magnetron (UBM) sputtering and arc ion plating (AIP). The pure Ti target was used for arc ion plating and other metal targets (V, Si and Nb) were used for sputtering process at a gas mixture of Ar/$N_2$ atmosphere. Mostly all of the films were grown with textured TiN (111) plane except the Si doped Ti-Si-N film which has strong (200) peak. The microhardness of each film was measured using the nanoindentation method. The minimum value of removal rate ($0.5{\times}10^{-15}\;m^2/N$) was found at Nb doped Ti-Nb-N film which was composed of Ti-N and Nb-N nanoparticles with small amount of amorphous phases.

Study on Fuel Lubrication Performance of a High Speed Rolling Element Bearing (소형 고속 구름베어링의 연료윤활 특성 연구)

  • Kim, Ki-Tae;Kim, Sung-Kyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.424-426
    • /
    • 2008
  • A parametric study was carried out to find the fuel lubrication performance of high speed small rolling element bearings. Both MIL-PRF-7808 turbine oil and JP-8 aircraft fuel were used as the lubricant to compare the operational characteristics. 17 mm inner diameter deep groove ball bearing and 20 mm cylindrical roller bearing were used. A high speed bearing test rig was developed and the testing was done with varying applied load, cooling air temperature, lubricant flow rate, and speed. Fuel caused more cage wear than oil for ball bearing with increasing axial load and rotational speed. The bearing temperature using fuel was lower than that using oil, and this seems to be the result of the high cooling capacity of fuel. According to various tests, the fuel lubrication is applicable for the lubrication on the main shaft bearings of expendable small gas turbines.

  • PDF

Ultrasonic Cavitation Behavior and its Degradation Mechanism of Epoxy Coatings in 3.5 % NaCl at 15 ℃

  • Jang, I.J.;Jeon, J.M.;Kim, K.T.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.26-36
    • /
    • 2021
  • Pipes operating in the seawater environment faces cavitation degradation and corrosion of the metallic component, as well as a negative synergistic effect. Cavitation degradation shows the mechanism by which materials deteriorate by causing rapid change of pressure or high-frequency vibration in the solution, and introducing the formation and explosion of bubbles. In order to rate the cavitation resistance of materials, constant conditions have been used. However, while a dynamic cavitation condition can be generated in a real system, there has been little reported on the effect of ultrasonic amplitude on the cavitation resistance and mechanism of composites. In this work, 3 kinds of epoxy coatings were used, and the cavitation resistance of the epoxy coatings was evaluated in 3.5% NaCl at 15 ℃ using an indirect ultrasonic cavitation method. Eleven kinds of mechanical properties were obtained, namely compressive strength, flexural strength and modulus, tensile strength and elongation, Shore D hardness, water absorptivity, impact test, wear test for coating only and pull-off strength for epoxy coating/carbon steel or epoxy coating/rubber/carbon steel. The cavitation erosion mechanism of epoxy coatings was discussed on the basis of the mechanical properties and the effect of ultrasonic amplitude on the degradation of coatings.

Effect of Modified High-heels on Metatarsal Stress in Female Workers

  • Kim, Kwantae;Peng, Hsien-Te
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.3
    • /
    • pp.197-204
    • /
    • 2019
  • Objective: The purpose of this study was to identify the effect of high-heels (HH) modification on metatarsal stress in female workers. Method: Seven females who work in clothing stores ($heights=160.4{\pm}3.9cm$; $weights=47.4{\pm}4.1kg$; $age=31.3{\pm}11.1yrs$; $HH\;wear\;career=8{\pm}6.5yrs$) wore two types of HH (original and modified). The modified HH had been grooved with 1.5 cm radius and 0.2 cm depth around the first metatarsal area inside of the shoes using the modified shoe-last. Participants were asked to walk for 15 minutes on a treadmill and to stand for 10 minutes with original and modified HH, respectively. Kinetics data were collected by the F-scan in-shoe system. After each test, participants were asked to rate their perceived exertion using the Borg's 15-grade RPE scale and interviewed about their feeling of HH. Nonparametric Wilcoxon signed-rank test and effect size (Cohen's d) were used to determine the difference of the variables of interest between the original and modified HH. Results: In the present study, modified HH of the peak contact pressure of 1st metatarsal (PCP) left, PCP right, pressure time integral (PTI) left, peak pressure gradient (PPG) left during standing and PPG right during walking are greater than original HH. And even it didn't show statistically significant, the average in all pressure values of modified HH showed bigger than original HH. It surmised to be related to awkward with modified HH. Even though they said to feel the comfortable cause of big space inside of HH in the interview, they seemed to be not enough time to adapt with new HH. So their walking and standing postures were unstable. Conclusion: Modified the fore-medial part of HH can reduce the stress in the first metatarsal head and big toe area during standing and walking.

A Study on the Physical Properties and Coating of Metal Surface Using Traditional Lacquer Technique (전통 옻칠 기법을 이용한 금속표면 코팅 및 물성 연구)

  • Cho, Sung Mo;Oh, Han Seo;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.302-311
    • /
    • 2021
  • This study uses traditional lacquer techniques to coat the metal surface and evaluates its physical properties to check the applicability of the lacquer coating. For this purpose, a total of six specimens were produced by setting the variation conditions for the number of times (1, 2, 3) and the heating temperature (120℃, 150℃) using SS275 metal(60*60 mm) and 'Wonju lacquer'. For analysis, chromaticity measurements, contact angle/surface energy measurements, Chemical Resistance, and cross-cut tests were used. The analysis showed that the corrosivity was improved and the adhesion of lacquer to the metal surface was excellent. There was no significant change in contact angle/surface energy. Also, there was no significant difference in color. Through this study, it was confirmed that lacquer on metal surfaces improves waterproofing and has a anticorrosion effect. We could also check the proper number of lacquer and heating temperature. Additional physical characteristics such as hardness and wear rate should be studied. It is also necessary to study how lacquer can be painted with a certain thickness.

Evaluation on Wear Sensation of Safety Clothing for Current Street Cleaners -Focusing on Publicly Supplied Safety Clothing for Street Cleaners- (현 환경미화원용 안전작업복의 착용감 평가 -공적으로 공급된 환경미화원복을 중심으로-)

  • Park, Soonja;Dempoya, Ayano;Koshiba, Tomoko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.6
    • /
    • pp.1037-1052
    • /
    • 2020
  • This study evaluates the comfort and suitability of safety clothing. We made three safety clothes 'y', 'lg', 'lgH'. Only 'y' made with fluorescence fabric has passed International Standards (ISO 20471). A wearing test investigated the physiological response and subjective sensations at 30℃ and 50% RH, six men participated. Mean skin temperature and tympanic temperature showed significant difference with experimental course (p<.05). The micro-temperature (Tm) showed significant differences between three garments on the thigh (p<.01). When wearing 'lg', Tm was the highest. Micro-humidity indicated the interaction between clothing and the experimental course on the chest with no significant difference; however, there was a low tendency when wearing 'lgH' after the second half of exercise. The sweat rate indicated a significant difference between 'lg' and 'lgH' at 20 minutes of exercise (p<.05). Three sensations showed significant differences with the time (p<.01), there was also a tendency to feel hotter and more humid when wearing 'lg'. Skin sensation showed significant differences between pre-experiment and post-experiment (p<.05), 'y' was the most preferred. The 'lg' with long-sleeved currently worn in Korea tended to feel hotter, more humid and more uncomfortable than 'y'. It indicates that there is room for improvement in Korean safety clothing.

Effects of Wearing COVID-19 Protective Face Masks on Respiratory, Cardiovascular Responses and Wear Comfort During Rest and Exercise (휴식과 운동 중 COVID-19 대응 보건용 마스크 착용이 호흡·심혈관계 반응 및 착용감에 미치는 영향)

  • Jung, Jae-Yeon;Kang, ChanHyeok;Seong, Yuchan;Jang, Se-Hyeok;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.22 no.6
    • /
    • pp.862-872
    • /
    • 2020
  • This study explores the effects of facemasks on respiratory, thermoregulatory, cardiovascular responses during exercise on a treadmill and at rest. Five male subjects (25.8 ± 0.8 y, 171.8 ± 9.2 cm in height, 79.8 ± 28.1 kg in weight) participated in the following five experimental conditions: no mask, KF80, KF94, KF99, and N95. Inhalation resistance was ranked as KF80 < KF94 < N95 < KF99 and dead space inside a mask was ranked as KF80 = KF94 < N95 < KF99. The surface area covered by a mask was on average 1.1% of the total body surface area. The results showed no significant differences in body core temperature, oxygen consumption (VO2), carbon dioxide production (VCO2), heart rate or subjective perception among the five experimental conditions; however, cheek temperature, respiratory ventilation and blood pressure were greater for KF80 or KF94 conditions when compared to KF99 or N95 conditions (p<0.05). The differences among mask conditions are attributed to the dead space or specific designs (cup type vs pleats type) rather than the filtration level. In addition, the results suggest that improving mask design can help mitigate respiratory resistance from increased filtration.