• Title/Summary/Keyword: Wear Microhardness

Search Result 86, Processing Time 0.026 seconds

Correlation between microhardness and wear resistance of dental alloys against monolithic zirconia

  • Cha, Min-Sang;Lee, Sang-Woon;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.127-135
    • /
    • 2021
  • Purpose. The aim of this study is to compare the hardness according to the conditions of metal alloys. Moreover, the correlation between the cast crown hardness before and after wear testing and the degree of wear for each dental alloy was assessed. Materials and Methods. Cast crowns of three metal alloys (Co-Cr, gold, and Ni-Cr alloys) opposing smooth-surface monolithic zirconia were used. The Vickers microhardness of the ingot (which did not undergo wear testing) and the cast crown before and after wear testing were measured for each alloy. Two-way ANOVA and Scheffé tests were used to compare the measured hardness values. Moreover, the Pearson correlation coefficient was used to evaluate the relationship between the surface hardness and the wear of the cast crown (α=.05). Results. There was no significant difference in the hardness before and after wear testing for the gold alloy (P>.05); however, the hardness of the worn surface of the cast crown increased compared to that of the cast crown before the wear tests of Ni-Cr and Co-Cr alloys (P<.05). Furthermore, there was no correlation between the wear and hardness of the cast crown before and after wear testing for all three metal alloys (P>.05). Conclusion. There was a significant difference in hardness between dental alloys under the same conditions. No correlation existed between the surface hardness of the cast crown before and after wear testing and the wear of the cast crown.

Effect of Ultrasound on the Mechanical Properties of Electrodeposited Ni-SiC Nano Composite

  • Gyawali, Gobinda;Cho, Sung-Hun;Woo, Dong-Jin;Lee, Soo-Wohn
    • Korean Journal of Materials Research
    • /
    • v.20 no.8
    • /
    • pp.439-443
    • /
    • 2010
  • Nano sized SiC particles (270 nm) are easily agglomerated in nickel sulfamate electrolytic bath during a composite electrodeposition process. The agglomeration of nano particles in composite coatings can significantly reduce the mechanical properties of the composite coatings. In this study, Ni-SiC nano composite coatings were fabricated using a conventional electrodeposition process with the aid of ultrasound. Nano particles were found to be distributed homogeneously with reduced agglomeration in the ultrasonicated samples. Substantial improvements in mechanical properties were observed in the composite coatings prepared in presence of ultrasound over those without ultrasound. Ni-SiC composite coatings were prepared with variable ultrasonic frequencies ranging from 24 kHz to 78 kHz and ultrasonic powers up to 300 watts. The ultrasonic frequency of 38 kHz with ultrasonic power of 200 watt was revealed to be the best ultrasonic conditions for homogeneous dispersion of nano SiC particles with improved mechanical properties in the composite coatings. The microstructures, phase compositions, and mechanical properties of the composite coatings were observed and evaluated using SEM, XRD, Vickers microhardness, and wear test. The Vickers microhardness of composite coatings under ultrasonic condition was significantly improved as compared to the coatings without ultrasound. The friction coefficient of the composite coating prepared with an ultrasonic condition was also smaller than the pure nickel coatings. A synergistic combination of superior wear resistance and improved microhardness was found in the Ni-SiC composite coatings prepared with ultrasonic conditions.

STUDIES ON THE HIGH TEMPERATURE PROPERTIES OF DUPLEX-TREATED AISI H13 STEEL

  • Chung, J.W.;Lee, S.Y.;Kim, C.W.;Kim, S.S.;Han, J.G.;Lee, S.Y.
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.634-639
    • /
    • 1996
  • In oder to improve the wear resistance as well as oxidation resistance at high temperature a AISI H13 steel was treated by a duplex process of calorizing followed by plasma nitriding. The surface properties of the duplex-treated AISI H13 steel was characterized and compared with those treated by single surface process of calorizing and plasma nitriding, in terms of microstruture, microhardness, wear resistance at $500^{\circ}C$, and the oxidation behaviours at $700^{\circ}C$, Duplex process on H13 steel had created duplex layer of approximately $190\mu\textrm{m}$ on the surface, and surface microhardness was measured to be above 1450Hv(0.1Kgf). There was considerable improvement of the high temperature wear resistance at $500^{\circ}C$ in the duplex-treated steel when both wear volume and weight change due to oxidation were considered. In addition the duplex-treated steel showed an improved high temperature oxidation resistance than the plasma nitrided steel at $700^{\circ}C$.

  • PDF

A Study on the Duplex Treatment of Simultaneous Aluminizing-Chromizing and Plasma Nitriding for Improvement of Surface Properties (Al-Cr의 동시확산과 플라즈마 질화의 복합처리에의한 표면향상에 관한연구)

  • 양준혁;이상률;한전건
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.6
    • /
    • pp.325-333
    • /
    • 1998
  • A duplex surface treatment process of simultaneous aluminizing-chromizing process followed by plasma nitriding was performed on AISI HI3 steel and STS 403 steel. The properties of these duplex-treated steels were investigated and were compared with those of steels treated by single process of either simultaneous aluminizing-chromizing or plasma nilriding, in terms of microstructure, microhardness and high temperature wear resistance. Sim~dtaneous alumizing-chromizing process was done using a 2-step coating cycle and plasma nitriding process was done at $530^{\circ}C$ for 1.5 hour. AISI HI3 steel and STS 403 steel showed a FeA1 compound layer of approximately 350$\mu\textrm{m}$ thickness on the surface after simultaneous diffusion coating and nitrided layer of approximately 70-80$\mu\textrm{m}$ formed after the subsequent plasma nitriding process. The microhardness was improved much more by the duplex surface heatment than only by plasma nitriding. In addition the duplex treated specimens showed an improved high temperature wear resistance.

  • PDF

A Study on the Surface Modification of Polyimide Film by ion Implantation (이온주입법에 의한 폴리이미드 박막의 표면개질에 대한 연구)

  • Kim, J.T.;Yuk, J.H.;Park, J.K.;Hwang, M.H.;Lim, H.C.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1546-1548
    • /
    • 1997
  • We investigated microhardness, friction, wear and wettability of polyimide for finding out the influence of ion implantation on surface properties. For increasing doses microhardness increased. A reduction of the friction coefficient was most cases correlated with a reduction of wear. The contact angles of water for $B^+$, $N^+$ implanted polyimide decreased from $76^{\circ}$ to zero, as the fluences increased energy of 50, 200 keV.

  • PDF

Effects of PTFE and W Addition on the Anti-Wear Properties of Ni-P Coatings (PTFE 및 W 첨가가 Ni-P 도금의 내마모 특성에 미치는 영향)

  • Kim, Myung-Sik;Hong, Jin-Won;Bae, Kyoo-Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.2 s.19
    • /
    • pp.25-28
    • /
    • 2007
  • Electroless Ni-P coating is widely used for chemical, electronic, and semiconductor equipment parts because of its corrosion resistance. The incorporation of chemically-inert PTFE particles into the Ni-P films improves properties such as, non-stick, anti-adhesive and better corrosion resistance. However, soft PTFE particles degrade the hardness, wear and abrasion resistance. In this study, effects of PTFE and W addition to the Ni-P-coatings were compared by the XRD, SEM, sheet resistance, contact angle, and microhardness measurements. The change in sheet resistance was negligible, but contact angle was doubled by the addition of PTFE and W. The microhardness was lower for Ni-P-PTFE, but higher for Ni-P-PTFE-W coatings, compared to that of Ni-P coatings.

  • PDF

Effect of Nano-filled Protective Coating on Microhardness and Wear Resistance of Glass-ionomer Cements (나노필러가 함유된 표면보호재가 글라스 아이오노머 시멘트의 미세경도와 마모저항성에 미치는 효과)

  • Ryu, Wonjeong;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.226-232
    • /
    • 2019
  • The purpose of this study was to investigate the effect of adding a protective coating on the microhardness and wear resistance of glass ionomer cements (GICs). Specimens were prepared from GIC and resin-modified GIC (RMGI), and divided into 3 groups based on surface protection: (1) no coating (NC), (2) Equia coat coating (EC), and (3) un-filled adhesive coating (AD). All specimens were then placed in distilled water for 24 h. Surface hardness (n = 10) was evaluated on a Vickers hardness testing machine. Wear resistance (n = 10) was evaluated after subjecting the specimen to thermocycling for 10,000 cycles using a chewing simulator. Data were analyzed using a one-way ANOVA and the Kruskal-Wallis test. Surface hardness was highest in the NC groups, followed by the EC and AD groups. The wear depth of GI + NC was significantly higher than that of all RMGI groups. EC did not significantly lower the wear depth compared to AD. Based on these results, it was concluded that although EC does not increase the surface microhardness of GIC, it can increase the wear resistance.

Wear Mechanism of Plasma-Sprayed Coating in Mo- and Co-Based Alloy

  • Lee, Soo W.
    • Tribology and Lubricants
    • /
    • v.11 no.5
    • /
    • pp.108-113
    • /
    • 1995
  • Wear and friction behavior of plasma-sprayed coatings in Mo- and Co-based alloy were studied for the application of piston-ring automobile engine. The plasma-sprayed coatings were varied with gun current density, gas flow, and distance. The surface roughness, microhardness, and wear volume were measured depending on the spray distances. The high temperature hardness value were also measured as a function of temperature. Ball-on-disc geometry configuration tribometer was utilized in air. The wear tests were performed in the temperature ranges from room temperature to 825$^{\circ}$C to investigate the tribological trend of the piston-ring materials in the lack of lubricant. The cross sections of wear track were investigated, using microscopy.

Effect of Plating Parameters on the Electrodeposition of Ni-alumina Nanocomposite

  • Gyawalia, Gobinda;Woo, Dong-Jin;Lee, Soo-Wohn
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • $Ni-Al_2O_3$ nanocomposite coatings were fabricated by conventional electrodeposition technique using nickel sulfamate bath. Effect of plating parameters on electrodeposition of $Ni-Al_2O_3$ nanocomposite were studied. The properties of the nano composite were investigated by using SEM, XRD, and Vicker's microhardness test. The results demonstrated that $Al_2O_3$ incorporation in the composite coatings was found to be increased by increasing stir rate and $Al_2O_3$ content in plating bath. Microhardness of the composite coatings was also increased with increasing content of the nano particles in the plating bath. The surface morphologies of the nanocomposite coatings were found to be varied with varying pH, current densities as well as alumina content in the plating bath.

Effect of Post Heat Treatment on Wear Characteristics of Thermally Sprayed Co-based Self-flux Alloy Coating (코발트기 자융성합금 코팅의 마모특성에 미치는 후열처리의 영향)

  • Lee, Jae-Hong;Kim, Yeong-Sik
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.106-111
    • /
    • 2014
  • This article describes effect of post heat treatment on wear characteristics of thermally sprayed Co-based self-flux alloy coating. Co-based self-flux alloy coatings were deposited on steel substrates using a flame spray process. Post heat treatments were carried out at 800, 900, 1000 and $1100^{\circ}C$ for 30min in a vacuum chamber. For analysis of effect of post heat treatment on mechanical properties, wear test and hardness test were performed for post heat-treated coating specimen. Microstructures of heat treated coating layer and wear track were examined using SEM and EDS. Wear loss and hardness became lower with increasing post heat treatment temperature.