• Title/Summary/Keyword: Wear

Search Result 7,449, Processing Time 0.03 seconds

Study on the Lubricity Characteristics of Bio-heavy Oil for Power Generation by Various feedstocks (다양한 원료에 따른 발전용 바이오중유의 윤활 특성 연구)

  • Kim, Jae-Kon;Jang, Eun-Jung;Jeon, Cheol-Hwan;Hwang, In-Ha;Na, Byung-Ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.985-994
    • /
    • 2018
  • Bio-heavy oil for power generation is a product made by mixing animal fat, vegetable oil and fatty acid methyl ester or its residues and is being used as steam heavy fuel(B-C) for power generation in Korea. However, if the fuel supply system of the fuel pump, the flow pump, the injector, etc., which is transferred to the boiler of the generator due to the composition of the raw material of the bio-heavy oi, causes abrasive wear, it can cause serious damage. Therefore, this study evaluates the fuel characteristics and lubricity properties of various raw materials of bio-heavy oil for power generation, and suggests fuel composition of biofuel for power generation to reduce frictional wear of generator. The average value of lubricity (HFRR abrasion) for bio-heavy oil feedstocks for power generation is $137{\mu}m$, and it varies from $60{\mu}m$ to $214{\mu}m$ depending on the raw materials. The order of lubricity is Oleo pitch> BD pitch> CNSL> Animal fat> RBDPO> PAO> Dark oil> Food waste oil. The average lubricity for the five bio-heavy oil samples is $151{\mu}m$ and the distribution is $101{\mu}m$ to $185{\mu}m$. The order of lubricity is Fuel 1> Fuel 3> Fuel 4> Fuel 2> Fuel 5. Bio-heavy oil samples (average $151{\mu}m$) show lower lubricity than heavy oil C ($128{\mu}m$). It is believed that bio-heavy oil for power generation is composed of fatty acid material, which is lower in paraffin and aromatics content than heavy oil(B-C) and has a low viscosity and high acid value, resulting in inhibition of the formation of lubricating film by acidic component. Therefore, in order to reduce friction and abrasion, it is expected to increase the lubrication of fuel when it contains more than 60% Oleo pitch and BD pitch as raw materials of bio-heavy oil for power generation.

Synthesis and Lubricating Properties of Succinic Acid Alkyl Ester Derivatives (숙신산 알킬 에스테르 유도체의 합성 및 윤활특성)

  • Baek, Seung-Yeob;Kim, Young-Wun;Chung, Keun-Wo;Yoo, Seung-Hyun;Park, Su-Jin
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.196-202
    • /
    • 2011
  • In this paper, a series of alkyl succinic acid esters for base oil were synthesized by condensation reaction of succinic anhydride and fatty alcohol. The structures of the synthesized esters were confirmed by $^1H-NMR$, FT-IR spectrum and GC analysis. Basic properties of esters such as kinematic viscosity (KV), refractive index (RI), total acid number (TAN) and pour points were measured and lubricating properties such as SRV wear scar diameter (SRV WSD), fraction coefficient (COF) and 4-ball wear (4-ball WSD) were also evaluated. As the results of basic properties, KV, RI and pour point of synthetic esters increased as the carbon chain of the esters increased. Measurement value of total acid number (TAN) was indicated between 0.2~4 mgKOH/g, and that metal working fluids and pressure working oils are acceptable to use as base oil. Also, lubricating properties of the esters showed as follows: 0.391~0.689 mm of SRV WSD, 0.110~0.138 of SRV COF and 0.49~0.55 mm of 4-ball WSD depended on the structure of the esters. In a comparison on the lubrication capacity of the SRV test based on polyester TMPTO, SRV WSD result showed that a better performance caused by the alkyl group. On the other hand, SRV COF test was not influenced of the alkyl group which the capacity of the lubricant was sightly diminished than the comparison material, regardless of the alkyl group.

Physical Characterization of Domestic Aggregate (국내 골재의 물리적 특성 분석)

  • Junyoung Ko;Eungyu Park;Junghae Choi;Jong-Tae Kim
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.169-187
    • /
    • 2023
  • Aggregates from 84 cities and counties in Korea were tested for quality to allow analysis of the physical characteristics of aggregates from river, land, and forest environments. River and land aggregates were analyzed for 18 test items, and forest aggregates for 12 test items. They were classified according to watershed and geology, respectively. The observed physical characteristics of the river aggregates by basin were as follows: aggregates from the Geum River basin passed through 2.5, 1.2, 0.6, 0.3, 0.15, and 0.08 mm sieves; clay lumps constituted the Nakdong River basin material; aggregates from the Seomjin River basin passed through 10, 5, and 2.5 mm sieves; those from the Youngsang River basin passed through 1.2, 0.6, 0.3, 0.15, and 0.08 mm sieves; and aggregates from the Han River basin passed through 10, 5, 2.5, 1.2, 0.6, 0.3, and 0.08 mm sieves, Stability; Standard errors were analyzed for the average amount passing through 10, 0.6, and 0.08 mm silver sieves, and performance rate showed different distribution patterns from other physical characteristics. Analysis of variance found that 16 of the 18 items, excluding the absorption rate and the performance rate, had statistically significant differences in their averages by region. Considering land aggregates by basin, those from the Nakdong River basin excluding the Geum River basin had clay lumps, those from the Seomjin River basin had 10 and 5 mm sieve passage, aggregates from the Youngsang River basin had 0.08 mm sieve passage, and those from the Han River basin had 10, 0.6, and 0.08 mm sieve passage. The standard error of the mean of the quantity showed a different distribution pattern from the other physical characteristics. Analysis of variance found a statistically significant difference in the average of all 18 items by region. Analyzing forest aggregates by geology showed distributions of porosity patterns different from those of other physical characteristics in metamorphic rocks (but not igneous rocks), and distributions of wear rate and porosity were different from those of sedimentary rocks. There were statistically significant differences in the average volume mass, water absorption rate, wear rate, and Sc/Rc items by lipid.

Analysis of Traffic Safety Effectiveness of Vehicle Seat-belt Wearing Detection System (주행차량 안전벨트 착용 검지시스템 교통안전 효과 분석)

  • Ji won Park;Su bin Park;Sang cheol Kang;Cheol Oh
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.5
    • /
    • pp.53-73
    • /
    • 2023
  • Although it is mandatory to wear a seat belt that can minimize human injury when traffic accident occurs, the number of traffic accident casualties not wearing seat belts still accounts for a significant proportion.The seat belt wearing detection system for all seats is a system that identifies whether all seat passengers wear a seat belt and encourages their usage, also it can be a useful technical countermeasure. Firstly, this study established the viability of system implementation by assessing the factors influencing the severity of injuries in traffic accidents through the development of an ordered probit model. Analysis results showed that the use of seat belts has statistically significant effects on the severity of traffic accidents, reducing the probability of death or serious injury by 0.054 times in the event of a traffic accident. Secondly, a meta-analysis was conducted based on prior research related to seat belts and injuries in traffic accidents to estimate the expected reduction in accident severity upon the implementation of the system.The analysis of the effect of accident severity reduction revealed that wearing seat belts would lead to a 63.3% decrease in fatal accidents, with the front seats showing a reduction of 75.7% and the rear seats showing a reduction of 58.1% in fatal accidents. Lastly, Using the results of the meta-analysis and traffic accident statistics, the expected decrease in the number of traffic accident casualties with the implementation of the system was derived to analyze the traffic safety effects of the proposed detection system. The analysis demonstrated that with an increase in the adoption rate of the system, the number of casualties in accidents where seat belts were not worn decreased. Specifically, at a system adoption rate of 60%, it is anticipated that the number of fatalities would decrease by more than three times compared to the current scenario. Based on the analysis results, operational strategies for the system were proposed to increase seat belt usage rates and reduce accident severity.

A Study on Wearable Emotion Monitoring System Under Natural Conditions Applying Noncontact Type Inductive Sensor (자연 상태에서의 인간감성 평가를 위한 비접촉식 인덕티브 센싱 기반의 착용형 센서 연구)

  • Hyun-Seung Cho;Jin-Hee Yang;Sang-Yeob Lee;Jeong-Whan Lee;Joo-Hyeon Lee;Hoon Kim
    • Science of Emotion and Sensibility
    • /
    • v.26 no.3
    • /
    • pp.149-160
    • /
    • 2023
  • This study develops a time-varying system-based noncontact fabric sensor that can measure cerebral blood-flow signals to explore the possibility of brain blood-signal detection and emotional evaluation. The textile sensor was implemented as a coil-type sensor by combining 30 silver threads of 40 deniers and then embroidering it with the computer machine. For the cerebral blood-flow measurement experiment, subjects were asked to attach a coil-type sensor to the carotid artery area, wear an electrocardiogram (ECG) electrode and a respiration (RSP) measurement belt. In addition, Doppler ultrasonography was performed using an ultrasonic diagnostic device to measure the speed of blood flow. The subject was asked to wear Meta Quest 2, measure the blood-flow change signal when viewing the manipulated image visual stimulus, and fill out an emotional-evaluation questionnaire. The measurement results show that the textile-sensor-measured signal also changes with a change in the blood-flow rate signal measured using the Doppler ultrasonography. These findings verify that the cerebral blood-flow signal can be measured using a coil-type textile sensor. In addition, the HRV extracted from ECG and PLL signals (textile sensor signals) are calculated and compared for emotional evaluation. The comparison results show that for the change in the ratio because of the activation of the sympathetic and parasympathetic nervous systems due to visual stimulation, the values calculated using the textile sensor and ECG signals tend to be similar. In conclusion, a the proposed time-varying system-based coil-type textile sensor can be used to study changes in the cerebral blood flow and monitor emotions.

Pain Complaint according to Usage of Standard-Sized Desks and Chairs for Middle and High School Students (중(中)·고등(高等) 학생(學生)들의 책상 및 의자(椅子)의 표준호식(標準號數) 사용여부(使用與否)와 통증(痛症) 호소율(呼訴率))

  • Kang, Kyung Yull;Cha, Byong Jun;Park, Jae Yong
    • Journal of the Korean Society of School Health
    • /
    • v.8 no.2
    • /
    • pp.219-232
    • /
    • 1995
  • This study was conducted to examine both usage rate of standard sized desks and chairs for the middle and high school students and pain complant of students who use standard-size desk & chair in Taegu, Korea, by means of questionnaires with 1,201 students of both male and female middle and high schools in Taegu area from March 20 to April 19, 1995. The result of this study is summarized as follows. It was mostly shown that the desks and chairs used by those middle and high school students were 1-3 higher than their standard sizes, and that they also preferred a little higher size with respect to their desired sizes. The rate of students who use the standard size showed that the desk accounted for 30.5%, and chair for 21.0%, that the size bigger than the standard accounted for 61.3%, respectively, and 65.2, and that the size smaller than the standard accounted for 8.2%, respectively, and 13.8%. The using rate of the standard sized for the middle school students indicated that their desk accounted for 44.1%, and their chair for 26.0% which were higher than 16.1% and 14.7% for the high school students. Then, the rate of the male students indicated that their desk accounted for 31.5% and their chair for 24.5% which were higher than 29.6% and 17.6% of the female students. In addition, the using rate of the standard size for the public schools showed that the desk accounted for 34.2% and chair for 24.5% which were also higher than 27.1% and 17.5% of the private schools. It was shown, however, that the using rate of the standard size for both groups was lower. The most inconvenient factor in the usage of their desks appeared in such orders as their wear, narrow drawers, too low height and uneven face, while the factor in their chairs did in such orders as too hard chair body the surface and back part, wear, lower and higher height and narrow width. Their physical pains resulting from usage of those desks and chairs showed that the male and female middle school students' complaint rate of pains in their neck and shoulder accounted for 32.1%, respectively, and 36.0% which were highest, while those high school students' complaint rate in their waist accounted for 37.9%, respectively, and 44.1% which were hight. It was also shown that the bigger their height, the higher their complaint rate of pain in the waist, and that their complaint rate in the shoulder and neck was totally higher. When using the standard-sized desks and chairs, their complaint rate of pain in the shoulder and neck accounted for 25.4%, respectively, and 23.8%. As compared with them, when using the desks or chairs bigger than the standard size, their complaint rate accounted for 31.5%, respectively, and 31.8% which were high while it did 26.5% and 28.9% when using them smaller than the standard size which were also high, the usage of those standard-sized desks and chairs indicated lower complaint rate of pain in their waist than used the desks and chairs bigger or smaller than the standard size. The rate of the middle and high school students who use their standard size is very low and the size of their desks and chairs are quite different from those they hope to use and many students appeal their discomfort with their desks and chairs. Therefore, the school should try to provide the desks and chairs of the various students' standard sizes in consideration of their physical condition and it also should try to get extra desks and chairs of various sizes according to the students' standard size and their preference.

  • PDF

Comparative analysis of status of safety accidents and importance-performance analysis (IPA) about precautions of safety accidents by employment type of industry foodservices in Jeonbuk area (전북지역 산업체급식소 조리종사자의 고용형태에 따른 안전사고 실태 및 안전사고 예방관리에 대한 중요도와 수행도 분석)

  • So, Hee;Rho, Jeong Ok
    • Journal of Nutrition and Health
    • /
    • v.50 no.4
    • /
    • pp.402-414
    • /
    • 2017
  • Purpose: The purpose of the study was to evaluate the status of safety accidents and importance-performance analysis (IPA) between regular and non-regular employees in industry foodservices. Methods: The participants were regular employees (n = 119) and non-regular employees (n = 163) in industry foodservices in the Jeonbuk area. Demographic characteristics, status of safety accidents, safety education, and importance and performance status were assessed using a self-administered questionnaire. Results: Approximately 66.4% of regular employees and 53.4% of non-regular employees experienced safety accidents (p < 0.05). Types of safety accidents of regular and non-regular employees were mostly burns, and causes were mostly from their own negligence. Approximately 98.3% of regular employees and 95.1% of non-regular employees experienced safety education. Approximately 88.9% of regular employees and 96.8% of non-regular employees received safety education from dietitians. Approximately 41.9% of regular employees and 50.0% of non-regular employees had difficulty applying the contents of safety education due to lack of time during work. As a result of IPA, regular and non-regular employees were aware of the importance of the following and performed them well: 'Clean the floor of the work place', 'Arrange in the work area', 'Wear safety shoes', 'Check for heater cord', and 'Safety cooking when using oil'. On the other hand, they were not aware of the importance of the following and performed them insufficiently: 'Check for the MSDS', 'Aware of chemical signs', 'Wear protection gloves etc.', 'Do stretching exercise', and 'Using ancillary tools'. Conclusion: Therefore, it is necessary to improve the consciousness of dietitians for effective application of safety education contents, development of contents, especially MSDS, and related things.

A Study on the Efficacy and Compliance of Oral Appliances according to the Severity of Apnea in the Treatment of Snoring and Obstructive Sleep Apnea (코골이와 폐쇄성수면무호흡증 환자에서 무호흡 심도에 따른 구강내 장치의 치료효과 및 환자의 적응도에 관한 연구)

  • 안홍균;이광호;정성창
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.4
    • /
    • pp.419-432
    • /
    • 1998
  • The purpose of this Study was to examine the efficacy and compliance of a mandibular advancement device(MAD) according to the severity of sleep apnea in the snorers and obstructive sleep apnea patients. Fifty-four patients (45 males, 9 females, aged 20 - 68years ) who visited Seoul National Uiversity Dental Hospital(SNUDH) to seek for the treatment of snoring and sleep apnea were classified into four groups according to the results of the nocturnal polysomnography and they were instructed to wear MAD regularly which was designed to increase the size of the upper airway by advancing the mandible. The evaluation of the efficacy and compliance of the MAD according to the severity of apnea and the duration after the usage of MAD ( 1week, 1month, 3months, 6months, 12months) was made by using quesionnaires mad in Department of Oral Medicine and Oral diagnosis, SNUDH. The obtained results were as follows : 1. All subjects results were habitual snoreres and 43 patients(79.6%) complained the loudness of snoring that can be heard out of the room. 2. Apnea index(AI) of the total subjects was mean 29.4$\pm$26.9 and respiratory disturbance index(RDI)was mean 37.6$\pm$28.0. And there was nodifference in the efficacy and the compliances of MAD according to the severity of apnea. 3. The severityi of apnea by the questionnaires significantly corresponded with the results of nocturnal polysomnography, and this fact potentiated the diagnostic value of the questionnaire. 4. after the usage of MAD, there was significant improvement in the frequency of snoring, the loudness of snoring, frequency of apnea, daytime sleepiness nad the refreshment after sleep(p<0.001) regardless of the apnea index(AI) and respiratory distrubance index(RDI). 5. The degree of the satisfaction with MAD was mean 74.4$\pm$18.4% and that of the discomfort with the MAD was 31.4$\pm$19.6%. But there was no serious complication in occlusion and temporomandibular joint with the usage of MAD and the duration of the discomfort was mean 3.3$\pm$2.2 weeks. 6. Forty-one patients(75.9%) continued the usage of MAD but thirteen patients(24.1%) stopped the use of MAD because of the discomforts and insufficient results with it.

  • PDF

A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes (기능성 전문테니스화의 족저압력분포 분석)

  • Lee, J.S.;Kim, Y.J.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.

A comparison study for mask plantar pressure measures to the difference of shoes in 20 female (20대 여성의 신발종류에 따른 족저압 영역별 비교 연구)

  • Kim, Y.J.;Ji, J.G.;Kim, J.T.;Hong, J.H.;Lee, J.S.;Lee, H.S.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.83-98
    • /
    • 2004
  • The purpose of this study was to investigate the test-retest of plantar pressures using the F-Scan system over speeds and plantar regions. 6 healthy female subjects in 20's were recruited for the study. Plantar pressure measurements during locomotor activities can provide information concerning foot function, particularly if the timing and magnitude of the loading profile can be related to the location of specific foot structures such as the metatarsal heads. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right. left shoes - sneakers shoes & dress shoes. It was calibrated by the known weight of the test subject standing on one foot. The Tekscan measurements show the insole pressure distribution as a function of the time. This finding has important implications for the development of plantar pressure test protocols where the function of the forefoot is important. According to the result of analysis it is as follows 1) Center of force trajectory in women's dress shoes display direct movement, compare with center of force trajectory in Sneaker shoes displays a little bit curved slow pronation movement. Sneaker shoes in forefoot part display very quick supination movement, therefore, this shoes effects negative effectiveness for ankle's stability Considering center of force trajectory analyzing the more center of force close straight line, the more movement can be quick movement for locomotion. For foot pressure distribution, center of force trajectory in locomotion is better to curved trajectory with pronation movement. So sneaker shoes style is good shoes considering center of pressure distribution trajectory compare with women's dress shoes. 2) Women's dress shoes increased peak pressure in medial, this is effected by high hill's height. The more increased women's dress shoes's height, the more women's peak pressure will increase, pronation can increase compare with before. Supination movement increase, this focused pressure in lateral, also, supination increased more. If the supination movement increased, foot pressure focused in lateral, therefore, it is appeared force distribution in gait direction. This is bad movement in foot's stability. 3) Women's dress shoes in landing phase displayed a long time, this is when women's dress shoes wear, gait movement is unbalance, so, landing phase displayed a long time. For compensation in gait, swing phase quick movement. 4) Women's dress shoes displayed peak pressure distribution in lateral of rearfoot part, Sneakers shoes displayed peak pressure distribution in medial of forefoot part. Its results has good impact absorption compare with women's dress shoes. In forefoot part, sneakers shoes has good propulsive force compare with women's dress shoes.