• Title/Summary/Keyword: Waveplate

Search Result 12, Processing Time 0.039 seconds

Improvement of Calibration Method for a Dual-rotating Compensator Type Spectroscopic Ellipsometer

  • Byeong-Kwan Yang;Jin Seung Kim
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.428-434
    • /
    • 2023
  • The compensators used in spectroscopic ellipsometers are usually assumed to be ideal linear waveplates. In reality, however, they are elliptical waveplates, because they are usually made by bonding two or more linear waveplates of different materials with slight misalignment. This induces systematic error when they are modeled as linear waveplates. We propose an improved calibration method based on an optical model that regards an elliptical waveplate as a combination of a circular waveplate (rotator) and a linear waveplate. The method allows elimination of the systematic error, and the residual error of optic axis measurement is reduced to 0.025 degrees in the spectral range of 450-800 nm.

Generation of Radially or Azimuthally Polarized Laser Beams in a Yb:YAG Thin-disc Laser

  • Ye Jin Oh;In Chul Park;Eun Kyoung Park;Jiri Muzik;Yuya Koshiba;Pawel Sikocinski;Martin Smrz;Tomas Mocek;Hoon Jeong;Ji Won Kim
    • Current Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.416-420
    • /
    • 2024
  • A high-power Yb:YAG thin-disc laser with radial or azimuthal polarization incorporating an intracavity S-waveplate is reported. Depending on the rotational angle of the S-waveplate placed in the cavity, a Yb:YAG thin-disc laser yields 10.8 W and 10.2 W of continuous-wave outputs with radial and azimuthal polarization for an incident pump power of 131 W, corresponding to slope efficiencies of 22.9% and 23.7%, respectively. The output characteristics for each polarization state were investigated in detail by analyzing the insertion loss and the mode overlap efficiency due to the S-waveplate. Further prospects for power scaling will be discussed.

Elimination of polarization dependency of fiber-to-planar waveguide couplers using a half-waveplate (반파장판을 이용한 광섬유-평면도파로 결합기의 편광 의존성 제거)

  • Lee, Kyu-Hyo;Kim, Hyo-Kyeom;Kim, Kwang-Taek
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.2
    • /
    • pp.138-142
    • /
    • 2005
  • In this paper, a method to eliminate the polarization dependent properties of fiber-to-planar waveguide couplers using a thin half-waveplate is proposed and demonstrated. The operation principle of the device is explained and the fabrication technology is presented. It is experimentally shown that the resonance wavelengths of the device are independent of the polarization state of input light.

The Theoretical Analysis about the Phase-Shifting Technique of Shearography Using Waveeplates (파장판을 이용한 Shearography의 위상천이기술에 대한 이론적 고찰)

  • Kim, Soo-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.8-13
    • /
    • 2004
  • We presented the method to obtain four speckle interferograms with relative phase shift of $\pi$/2 by passive devices such as waveplate and polarizer, calculate the phase at each point of the speckle interferogram in shearography using Wollaston prism, and theoretically demonstrated the feasibility of the unposed method by Jones matrix.

Theoretical analysis and Phase Error Analysis of the Shearographic System for the Deformation Evaluation of Semiconductor Equipment (반도체 장비의 변형 진단을 위한 shearographic system의 이론적 고찰 및 위상오차해석)

  • Kim, Soo-Gil;Hong, Sun-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.1 s.10
    • /
    • pp.17-21
    • /
    • 2005
  • We presented a new method to obtain four speckle interferograms with relative phase shift of $\pi$/2 by passive devices such as waveplate and polarizer, calculate the phase at each point of the speckle interferogram in shearography using Wollaston prism, which can be applied to the deformation evaluation of semiconductor devices, and theoretically demonstrated the feasibility of the proposed method by Jones matrix.

  • PDF

Real-time Measurement of Full Field Retardation Near Quarter Wavelength

  • Liu, Longhai;Zeng, Aijun;Yuan, Qiao;Zhu, Linglin;Fang, Ruifang;Huang, Huijie
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.457-461
    • /
    • 2012
  • A real-time method to measure full field retardation near quarter wavelength is proposed. The circularly polarized beam passes through a sample with a large aperture. The measuring beam then goes through a quarter-wave plate and is then split by a Wollaston prism. An image with two sub-images is then detected by a high-speed image sensor. The full field retardation near quarter wavelength can be obtained in real time by processing the image. The measured retardation is independent of the fast axis angle of the sample and the fluctuation of the initial intensity. In experiments, a wedge waveplate is measured with different fast axis angle and initial intensity, and the full field retardations are acquired. The maximum and standard deviation of the full field retardation is $1.5^{\circ}$ and $0.4^{\circ}$. The validity of the method is verified.

Developments of the Wide Wavelength Range Polarimeter of the Domeless Solar Telescope at the Hida Observatory

  • Anan, Tetsu;Ichimoto, Kiyoshi;Oi, Akihito;Ueno, Satoru;Kimura, Goichi;Nakatani, Yoshikazu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.86.1-86.1
    • /
    • 2011
  • We are developing a new universal spectropolarimeter on the Domeless Solar Telescope (DST) at the Hida Observatory to realize precise spectropolarimetric observations in a wide range of wavelength in visible and near infrared. The system aims to open a new window of plasma diagnostics by using Zeeman effect, Hanle effect, Stark effect, impact polarization, and atomic polarization for measuring the external magnetic field, electric field, or an anisotropy in the excitation of the atoms. The polarimeter is a successor of formerly developed polarimeter on DST, which make possible to observe a polarization in a photospheric spectral line with polarimetric accuracy of 10-2 (Kiyohara et al. 2004). The new system consists of a 60cm aperture vacuum telescope, a high dispersion vacuum spectrograph, polarization modulator / analyzer composed of a rotating waveplate whose retardation is constant for a wide range of wavelength and Wallaston prism, and a fast and large format CCD camera or IR camera. Spectral images in both orthogonal polarizations are taken simultaneously with a frame rate of ~20Hz while the waveplate rotates continuously in a rate of 1rev./sec. Thus It takes 5 ~ 60 sec to observe polarization with accuracy of 10-3 in a wide wavelength range (400 - 1100nm). We also examined a polarimetric model of the telescope with accuracy of 10-3 to calibrate instrumental polarization on some wavelengths. In this talk, I will focus on the performance of the instrument.

  • PDF

Integrated Optical Wave Plates Fabricated by Incorporating Reactive Mesogen in Polymer Waveguide (반응성 메조겐을 이용한 폴리머 광도파로 편광 변환기)

  • Do, Hyun-Soo;Chu, Woo-Sung;Oh, Min-Cheol
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.5
    • /
    • pp.219-222
    • /
    • 2011
  • Integrated optical waveguide polarization converters are among the essential components for constructing various functional optical integrated circuits. The RM materials have been widely used in liquid crystal displays for fabricating waveplates. In this work, the polarization converters are fabricated by using a solution of Reactive Mesogen(RM) dissolved in liquid crystal(LC). In the middle of the polymer waveguide, a groove is defined by an oxygen plasma etching in a direction perpendicular to the optical waveguide. The solution of RM-LC is inserted to fill up the groove, and then liquid crystal is aligned in a certain direction by applying an electric field. After the alignment, RM materal is crosslinked by UV light so as to form a permanent waveplate. The phase retardation of the waveplate is determined by the width of the groove, and by the birefringence and the degree of alignment of the LC. Polarization conversion efficiency of 90% is obtained for the wavelength of 1550 nm.

Measurement of Aerosols and Ice Clouds Using Ellipsometry Lidar (타원편광 라이다 개발 및 이를 이용한 에어로졸과 구름의 특성 측정)

  • Kim, Dukhyeon;Cheong, Hai Du;Volkov, Sergei N.
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.9-16
    • /
    • 2015
  • We have developed ellipsometry lidar and measured aerosol and ice-cloud characteristics. To measure a full normalized backscattering phase matrix (NBSPM) composed of nine elements, we have designed an optical system with three kinds of transmission and three kinds of reception, composed of ${\lambda}/2$ waveplate, ${\lambda}/4$ waveplate and empty optic. To find systematic optical errors, we used clean day middle-altitude (4-6km) lidar signals for which the aerosol's concentration was small and its orientation chaotic. After calibrating our lidar system, we have calculated NBSPM elements scattered from an aerosol and from an ice cloud. In the case of an aerosol, we found that the off-diagonal values $m_{12},{\ldots},m_{34}$ of the NBSPM are smaller than those for a cirrus cloud. Also, the off-diagonal values of the NBSPM from a cirrus cloud depend on atmospheric conditions.