• Title/Summary/Keyword: Waveforms

Search Result 1,052, Processing Time 0.033 seconds

High Temperature Fatigue Life and Fractography under Asymmetric Waveform in Strain Control (변형률제어 비대칭파형 하의 고온피로수명 및 파면)

  • 허정원;박원조;유재환
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.38-43
    • /
    • 2003
  • In this paper, the low cycle fatigue(LCF) life tests were carried out under waveforms of asymmetric triangle($4{\times}10^{-3}$ and $4{\times}10^{-10}$ strain rate) and hold-time(1min and 10min) in strain control. In triangular waveform, the fatigue lives of fast-slow waveforms were decreased to about 63-73% and them of slow-fast waveforms were down to about 23-24% compared to them of fast-fast waveforms. The shapes of fracture surfaces were transgranular in fast-fast and fast-slow waveforms and intergranular in slow-fast ones. The fatigue lives of slow-fast waveforms were remarkedly shorter than them of hold-time waveforms even though cycle times of hold time waveforms were longer than them of slow-fast ones. The damage mechanisms of frature surfaces were mixed frature with both transgranular and intergranular, but intergranular fratures were r-type cavity in hold-time waveforms and w-type cavity in slow-fast ones.

Properties of Pulse Waveforms by Posture Changes : Standing, Sitting, Supine Posture (측정 자세의 변화에 따른 맥의 변화 특성 : 선 자세, 앉은 자세, 누운 자세)

  • Kown, Sun-Min;Kang, Hee-Jung;Lee, Sang-Hun;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.26 no.4
    • /
    • pp.13-22
    • /
    • 2009
  • Objectives : Informations on pulse diagnosis in literature are based on diagnosing pulse waveforms on supine posture. However, today's pulse waveforms are measured on various postures for the convenience of patients or doctors. For objective measurement, the effect of posture on the pulse waveforms should be considered. The objective of this study was to find posture-related changes in the radial pulse waveforms. Methods : We used an instrument, DMP-3000(DAEYOMEDI Co., Ansan, Korea), measuring radial pulse waveforms noninvasively by tonometric method. 25 male subjects participated in the trial. Before measuring radial pulse waveforms subjects had rest for 5 min. The pulse waveforms were measured on the left wrist. Each subject underwent this course on the supine, sitting, and standing posture. We analyzed pulse waveforms with Height-parameters, Time-parameters, Energy, and Elastic rate. Results : Height-parameters(h1~h5) on the supine posture were bigger than those on the sitting and standing posture. In case of Time-parameters, the parameters making up systolic time decrease in order of on standing, sitting, and supine position. However, systolic time and diastolic time didn't have any changes. Energy of pulse was the biggest on supine posture and Elastic rate on standing posture. Conclusions : In this study we found that posture changes affect radial pulse waveforms. For quantification of the changes, more trials should be done. After analyzing much data we might apply parameters of pulse waveforms changed by posture. Also, we might diagnose special disease with properties of pulse waveforms by posture.

  • PDF

Liner Performance Analysis on the DS/CDMA Communication System using the Approximated Analytical Chip Waveforms (근사화된 해석적 칩파형을 사용한 DS/CDMA 통신 시스템의 선형 성능 분석)

  • 홍현문;김용로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.160-164
    • /
    • 2004
  • In DS/CDMA(direct sequence code division multiple access) system using the approximated analytic chip waveforms are applied. Proposed chip waveforms are classified into 2 types: uniform chip waveforms with uniform envelope and non-uniform chip waveforms with non-uniform envelope. It has confirmed that the similarity of the approximated analytical chip waveforms is compared using chip waveforms, envelope, phase, correlation, and bandwidth properties.

Reciprocal Sustain and Auxiliary Pulse Waveforms Applied to an AC PDP with an Auxiliary Electrode

  • Choi, Kyung-Cheol;Lee, Sung-Min;Choi, Chung-Sock;Jang, Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1543-1546
    • /
    • 2008
  • Modified pulse waveforms were applied to an AC plasma display panel with an auxiliary electrode in order to improve the operation voltage margin. Reciprocal sustain pulse waveforms and modified auxiliary pulse waveforms were applied to the sustain and auxiliary electrode, respectively. During the sustain period, the influence of the address electrode on the luminous efficacy of long-coplanar gap discharges was mitigated by application of reciprocal sustain pulse waveforms. Modified auxiliary pulse waveforms maintained the high efficacy obtained from the AC PDP with an auxiliary electrode. The proposed reciprocal sustain and modified auxiliary pulses waveforms can induce stable discharges in long-coplanar gap discharges and can control wall charges with a wider auxiliary pulse voltage margin, thereby enhancing the luminous efficacy of the AC PDP with an auxiliary electrode.

  • PDF

CSpeech(Version 3.1)

  • Sik, Choe-Hong
    • Proceedings of the KSLP Conference
    • /
    • 1995.11a
    • /
    • pp.141-153
    • /
    • 1995
  • CSpeech is a software package that implements an audio waveform/speech analysis workstation on an IBM Personal Computer or hardware compatible computer. Features include digitizing audio waveforms on single or multiple channels, displaying the digitized waveforms, playing back audio waveforms from selected intervals of sing1e channels, saving and retrieving waveforms from binary format disk files, and analysing audio waveforms for their temporal and spectral properties. The distinguishing characteristics of CSpeech are its support for multiple channels, minimal restrictions on sample rate and waveform duration support fur a variety of hardware configurations, fast graphics display, and its user- extensible menu- based command structure.

  • PDF

The Current and Power Waveform Improvement of a $3{\Phi}$ Induction Motor with LC Filter Driven by a Digital Bridge Inverter (디지탈 브리지형 인버터로 구동되는 3상유도전동기의 LC 필터에 의한 전류 및 전력 파형 개선)

  • Chung, J.Y.;Park, J.G.;Kang, C.N.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.553-555
    • /
    • 1996
  • This paper concerns with a method to improve the current and power waveforms of the variable speed $3{\Phi}$ AC motor system driven by the single-pulse PWM, and the current waveforms and $3{\Phi}$ power waveforms are analyzed by FFT under various running conditions. By the performance analysis through the experiments, the following results have been obtained. AC source of pseudo sine waveform can be obtained from the modulated alternating square voltage by means of the well designed LC filter. It is confirmed that current waveforms and $3{\Phi}$ power waveforms can be improved by utilizing the high order low pass LC filter than that of lower order. Especially, current waveforms and $3{\Phi}$ power waveforms tan be much improved at low frequency domain. $3{\Phi}$ power waveforms have a smatter ripple and bigger power by utilizing the high order low pass LC filter than that of lower order. Also, the running condition of $3{\Phi}$ AC motor is good at low frequency domain.

  • PDF

Pattern Recognition of Monitored Waveforms from Power Supplies Feeding High-Speed Rail Systems

  • Gu, Wei;Zhang, Shuai;Yuan, Xiaodong;Chen, Bing;Bai, Jingjing
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.55-64
    • /
    • 2016
  • The development of high-speed rail (HSR) has had a major impact on the power supply grid. Based on the monitored waveforms of HSR, a pattern recognition approach is proposed for the first time in this paper to identify the operating conditions. To reduce the data dimensions for monitored waveforms, the principal component analysis (PCA) algorithm was used to extract the characteristics and their waveforms from the monitored waveforms data. The dynamic time wrapping (DTW) algorithm was then used to identify the operating conditions of the HSR. Cases studies show that the proposed approach is effective and feasible, and that it is possible to identify the real-time operating conditions based on the monitored waveforms.

Statistical Analysis of Electric Field Waveforms Produced by Lightning Return Stroke (낙뢰에 의해서 발생되는 전장파형의 통계적 분석)

  • Lee, B.H.;Park, S.Y.;Ahn, C.H.;Kil, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1824-1826
    • /
    • 1997
  • In this paper, in order to obtain statistical informations on lightning electromagnetic waveforms, electric field waveforms produced by lightning return strokes were measured and analyzed. The electric field measuring system consists of hemisphere antenna 30[cm] in diameter, integrator and data acquisition. system. The frequency bandwidth of the measuring system is 200[Hz] to 1.56[MHz], and the sensitivity is 0.96[mV/V/m]. The mean value of front time of electric field waveforms produced by positive lightning return strokes is 5.87[${\mu}s$], and that of negative is 4.12[${\mu}s$]. The mean values of zero-crossing time for positive or negative electric field waveforms are 35.00 and 26.61[${\mu}s$], respectively. The mean value of percentage dip-depth for positive electric field waveforms is 33.68[%], and that for negative is 28.36[%].

  • PDF

A Study on Detection Method of Specific Waveform in Distribution Line (배전선로의 특이파형 검출 방법에 관한 연구)

  • Lee, Jin;Park, Chan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.2
    • /
    • pp.151-156
    • /
    • 2019
  • The aim of this investigation is to detect specific waveforms in a distribution line prior to the occurrence of a fault. Conditions were introduced such that a feeder remote terminal unit (FRTU) of the distribution automation system selects and stores fault waveforms from the different waveforms detected in the distribution line. In addition, an algorithm was developed to detect specific waveforms from the fault waveforms stored using the FRTU. This algorithm exploits the duration and periodicity of harmonic changes in voltage and current. The efficacy of the algorithm was confirmed based on the measurements of fault waveforms in an actual distribution line. The results indicated that faults in a distribution line can be predicted via experimental measurements.

Characteristics of the Voltage Waveforms Caused by Human Electrostatic Discharges (인체에 의한 정전기 방전전압 파형의 특성)

  • 이복희;강성만;엄주홍;이태룡
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.113-120
    • /
    • 2002
  • This paper describes characteristics of transient voltage waveforms caused by human electrostatic discharges(ESDs). For purpose of achieving the statistics on the meaningful amplitude and initial slope for transient ESD voltage waveforms, transient voltages due to human ESDs in various conditions were observed. A voltage measuring system with a wide bandwidth from DC to 400[MHz] was employed. ESD voltage waveforms are approximately the same as ESD current waveforms. Also the simulated results, which are calculated by the reposed equivalent circuit, are closely similar to the measured voltage waveforms. ESD voltage waveforms are strongly dependent on the approach speed and material of intruder, a fast approach causes ESD voltage waveform with a steep rise time than for a slow approach. The voltage waveforms from dialect finger ESDs have a relatively long rise time of 10∼30[ns], but their peaks are low. On the other side ESD voltage waveforms causer by screwdriver with insulating handle have a steep slope with a very short, less than 1[ns] rise time, but their initial spikes are extremely high The obtained results in this work would be applied to solve ESD problems for low voltage and small current electronic devices.