• 제목/요약/키워드: Wave Shaping

검색결과 58건 처리시간 0.032초

플라즈마 디스플레이 채널을 위한 단일 소프트-스위칭 다단계 에너지 회수 회로 드라이버 (Single Soft-Switching Multi-Level Energy Recovery Circuit Driver for Plasma Display Panel)

  • 하꼬보 아기용;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.413-416
    • /
    • 2006
  • The power source of an AC-PDP fur sustainer circuit is operated in high-voltage and high frequency switching during the process required to achieve the gas discharge current to generate light in a PDP panel. Since PDP has the characteristics of a pure capacitive load, the displacement current that occurs during charge and discharge generates considerable reactive power. An auxiliary circuitry called Energy Recovery Circuit (ERC) reduces the capacitive displacement current. However, this auxiliary topology also bears high stress in its components. In this paper, a multilevel voltage wave shaping sustainer circuit with auxiliary ERC characteristics for an AC-PDP driver is proposed. A comparative analysis and experimental results are presented.

  • PDF

Digital-Controlled Single-Phase Unified Power Quality Conditioner for Non-linear and Voltage Sensitive Loads

  • Ryoo Hong-Je;Kim Jong-Soo;Kisck Dragos Ovidiu
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.374-381
    • /
    • 2005
  • The ability to provide quality power has become a significant issue in power systems. The main causes of poor power quality are harmonic currents, poor power factor, supply-voltage variations, etc. A technique of achieving both active current distortion compensation, power factor correction and also mitigating the supply-voltage variation (sag or swell) at the load side is presented in this paper. The operation and rating issues of the proposed Single-phase Unified Power Quality Conditioner are also highlighted. To reduce the total cost while simultaneously increasing the performance, the system is fully digitally controlled using the fixed-point TMS320F240 digital signal processor. The performances of the UPQC, which is composed by shunt and series PWM controlled-converters, have been verified on a laboratory prototype.

TIME-DOMAIN TECHNIQUE FOR FRONT-END NOISE SIMULATION IN NUCLEAR SPECTROSCOPY

  • Neamintara, Hudsaleark;Mangclaviraj, Virul;Punnachaiya, Suvit
    • Nuclear Engineering and Technology
    • /
    • 제39권6호
    • /
    • pp.717-724
    • /
    • 2007
  • A measurement-based time-domain noise simulation of radiation detector-preamplifier (front-end) noise in nuclear spectroscopy is described. The time-domain noise simulation was performed by generating "noise random numbers" using Monte Carlo's inverse method. The probability of unpredictable noise was derived from the empirical cumulative distribution function via the sampled noise, which was measured from a preamplifier output. Results of the simulated noise were investigated as functions of time, frequency, and statistical domains. Noise behavior was evaluated using the signal wave-shaping function, and was compared with the actual noise. Similarities between the response characteristics of the simulated and the actual preamplifier output noises were found. The simulated noise and the computed nuclear pulse signal were also combined to generate a simulated preamplifier output signal. Such simulated output signals could be used in nuclear spectroscopy to determine energy resolution degradation from front-end noise effect.

제약산업의 분말 주사제 공정에서의 경제적 충진량 결정에 관한 연구 (A Study on Determination of Economic Filling Weight in the Powder Injection Process of the Pharmaceutical Industry)

  • 신일환;이영해
    • 산업경영시스템학회지
    • /
    • 제22권52호
    • /
    • pp.9-20
    • /
    • 1999
  • The standard deviation is constant in the progress of Powder Injection Filling, The setting value of the filling amount can modify the numerical rate. Since high level of the numerical rate can get the effect of reducing the material cost, it improves the productivity by permitting the possibility of the economical production. Consequently, this thesis analyzed and suggests the numerical model which consider the economical factors of the Powder Injection Shaping progress, and I try to reinforce the competitive powder of the domestic medicine manufacture industry which face the wave of globalism and evolutionism.

  • PDF

전류조형기법의 대용량 DCM 역률 보상 컨버터 (High-Power DCM PFC Converter with Current Wave-shaping)

  • 채형준;김경동;문형태;이준영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.387-388
    • /
    • 2012
  • 본 논문은 7kW급의 DCM PFC 회로를 제안한다. DCM 제어방식은 제어기의 복잡성이 단순하여 디지털 제어기 적용이 용이하며 인덕터 사이즈가 다른 방식에 비해 작게 설계됨으로 전력밀도를 높일 수 있지만 입력전압이 높아짐에 따라 역률은 상대적으로 낮아지는 단점이 있다. 본 논문에서는 7kW급 DCM 방식의 Boost PFC 컨버터를 구현하고 전류조형기법을 적용하여 넓은 입력 전압 범위에도 역률이 0.99이상이 되는 것을 실험을 통해 확인한다.

  • PDF

Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구 (Efficiency of the nickel-titanium rotary instruments for glide path preparation: in-vitro preliminary study)

  • 김현철;곽상원;하정홍
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.688-694
    • /
    • 2017
  • Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.

  • PDF

BF 컨버터의 고조파 감쇠에 관한 연구 (A study on the haromnic attenuation of the BF Converter)

  • 최태섭;안인수;임승하;사공석진
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.8-15
    • /
    • 2000
  • 본 논문에서는 F 컨버터의 능동형 PFC 시스템을 구성하고, 진력 변환시 입력 전류를 전원 전압과 동장연 정현파로 제이하는 동시에 출력 전압에 포함되는 고조파 등의 잡음을 제거하고 직류 출력 전압을 제어하기 위한 PWM-PFM 제어 기법을 제시하였다. 부하단에서 필요한 전압과 높은 전력 효율을 얻기 위하여 인버터 단계애서 전류 성형 제어를 실행한 후, 순방­향(forward) 컨버터에 의해 다시 직류 전압으로 변환시켜 부하단으로 출력한다. 입력 전압이 30[V]이교 승압 (boost) 인덕터가 1.1[mH]일 때 정격 출력은 전압 50[V], 전류1[A], 듀티비 0.5 이상으로 하여 부하 처항에 따른 전압 변화를 PWM-PFM 제어 기법을 이용하며 제어하였고, 전류 성형 기법을 이용하여 0.93획 역률로 고조파를 감쇠 및 개선하였다.

  • PDF

Several systems for 1Giga bit Modem

  • Park, Jin-Sung;Kang, Seong-Ho;Eom, Ki-Whan;Sosuke, Onodera;Yoichi, Sato
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1749-1753
    • /
    • 2003
  • We proposed several systems for 1Giga bit Modem. The first, Binary ASK(Amplitude Shift Keying) system has a high speed shutter transmitter and no IF(Intermediate Frequency) receiver only by symbol synchronization. The advantage of proposed system is that circuitry is very simple without IF process. The disadvantage of proposed system are that line spectrum occurs interference to other channels, and enhancement to 4-level system is impossible due to its large SNR degradation. The second, Binary phase modulation system has a high speed shutter transmitter and IF-VCO(IF-Voltage Controlled Oscillator) control by base-band phase rotation. Polarity of shutter window is changed by the binary data. The window should be narrow same as above ASK. The advantage of proposed system is which error rate performance is superior. The disadvantage of proposed system are that Circuitry is more complex, narrow pull-in range of receiver caused by VCO and spectrum divergence by the non-linear amplifier. The third, 4-QAM(Quadrature Amplitude Modulation)system has a nyquist pulse transmitter and IF-VCO control by symbol clock. The advantage of proposed system are that signal frequency band is a half of 1GHz, reliable pull-in of VCO and possibility of double speed transmission(2Gbps) by keeping 1GHz frequency-band. The disadvantage of proposed system are that circuit complexity of pulse shaping and spectrum divergence by the non-linear amplifier.

  • PDF

Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교 (COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE)

  • 이상진;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제32권6호
    • /
    • pp.491-497
    • /
    • 2007
  • 이 연구의 목적은 continuous wave of obturation technique으로 근관 충전을 할 때, 다양한 heat source plugger의 깊이에 따른 근단부 근관 폐쇄능력을 비교하는 것이었다. 직선 형태 발거 소구치를 #35/.06 크기까지 니켈티타늄 파일을 사용하여 성형 및 세정하였다. 성형과 세정이 완료된 치아를 heat source plugger의 적용 깊이에 따라 15개씩 5군으로 분류하였다. 3 mm, 4 mm, 5 mm, 6 mm, 7 mm, 양성 대조군을 제외한 모든 근관은 E&Q plus(Meta Biomed Co., Chungju, Korea)를 사용하여 #35/.06 gutta-percha cone으로 충전하였다. 모든 치아의 근첨공 주변 1 mm를 제외하고 nail varnish를 도포하였고 음성 대조군은 근첨공을 포함하여 전체 면을 도포하였다. 모든 시편을 1% 메틸렌블루 용액에 72시간 동안 보관한 다음 치근첨으로부터 1, 2, 3 mm 높이에서 수평으로 절단하였다. 각 단면을 $12.5{\times}2.5$배 현미경하에서 관찰하고 디지털 카메라로 촬영하였다. 염색제 누출 평가를 위해 aye-degree scoring system을 사용하였다. 각 절단면에서의 점수를 모두 합하여 한 시편의 점수로 사용하고 통계학적 분석을 하였다. 이 실험 조건하에서, 3-7 mm까지의 heat source plugger의 적용 깊이는 근단부 폐쇄에서 유의한 차이를 나타내지 않았다. 5-7 mm의 Buchanan's protocol을 포함한 3-7 mm를 모두 임상 적용에서 받아들여질 만하다고 보인다.

Comparison of vibration characteristics of file systems for root canal shaping according to file length

  • Seong-Jun Park;Se-Hee Park ;Kyung-Mo Cho ;Hyo-Jin Ji ;Eun-Hye Lee ;Jin-Woo Kim
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.51.1-51.10
    • /
    • 2020
  • Objectives: No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems. Materials and Methods: A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%. Results: In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups. Conclusions: In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.