• Title/Summary/Keyword: Wave Characteristic

Search Result 806, Processing Time 0.032 seconds

A Study on the Measurement of Foreign Material in Dissimilar Metal Contact Using Pulse Laser and Confocal Fabry-Perot Interferometer (펄스 레이저와 CFPI를 이용한 이종금속 접촉부의 이물질 측정에 관한 연구)

  • Hong, Kyung-Min;Kang, Young-June;Park, Nak-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.160-164
    • /
    • 2013
  • A laser ultrasonic inspection system is a non-contact inspection device which generates and measures ultrasonics by using laser beam. A laser ultrasonic inspection system provides a high measurement resolution because the ultrasonic signal generated by a pulse laser beam has a wide-band spectrum and the ultrasonic signal is measured from a small focused spot of a measuring laser beam. In this study, galvanic corrosion phenomenon was measured by non-destructive and non-contact method using the laser. The case of mixed foreign material on the part of corrosion was assumed and laser ultrasonic experiment was conducted. Ultrasonic was generated by pulse laser from the back side of the specimen and ultrasonic signal was acquired from the same location of the front side using continuous wave laser and Confocal Fabry-Perot Interferometer(CFPI). The characteristic of the ultrasonic signal of exist foreign material part was analyzed and the location and size of foreign material was measured.

Modal Analysis of Rectangular MQW Waveguide : A Novel Approach using Scanning Angle Method (직사각형 다중 양자 우물 도파관의 모드특성 분석 : Scanning angle method를 사용한 새로운 접근)

  • Im, Yeon-Seop;Choe, Yeong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.4
    • /
    • pp.45-52
    • /
    • 2000
  • We present a novel method for simple and efficient analysis of the rectangular MQW waveguide. Preferentially two-dimensional structure is transformed into one-dimensional structure by using the effective index method. Then, the characteristic matrix of the resultant planar MQW waveguide is analyzed by scanning angle method. The effective index, modal intensity, and optical confinement factor of rectangular MQW waveguide can be effectively obtained by this method. Our simulation results show excellent agreement with the accurate solutions based on the finite element method. We also introduce the approximation methods for the analysis of rectangular MQW waveguide and investigate their validity. By using perturbation approach, modal power loss of guided wave in rectangular MQW waveguide is newly investigated and compared with the conventional method using the approximation of planar MQW waveguide.

  • PDF

Design of a CP Spiral RFID Reader Antenna in UHF Band (UHF 대역 CP 스파이럴 RFID 리더 안테나 설계)

  • Lee, Chu-Yong;Choo, Ho-Sung;Park, Ik-Mo;Han, Wone-Keun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.5
    • /
    • pp.562-571
    • /
    • 2008
  • In this paper, we propose a novel structure of a spiral antenna with a CP characteristic for RFID reader in UHF band. Since the proposed antenna can be built by printing on a FR-4 substrate, it is appropriate for low-cost mass-production. The antenna is designed to operate in UHF band of $860{\sim}960$ MHz. The CP bandwidth is Increased enough to cover an overall UHF RFID band by using a spiral structure for the antenna arm. The matching bandwidth is broadened by using a quarter-wave transformer between the fred and the antenna body. The proposed antenna has advantages of its easy gain and pattern control with a small antenna size. The measured antenna performance shows the matching bandwidth of 13%, the CP bandwidth of 23%, and the gain of 6.5 dBi. This verifies that the proposed antenna is appropriate for RFID antennas in UHF band.

Clinical Usefulness of Phase-Contrast Cine MRI Evaluation in Patients with Cervical Myelopathy (경추 척수병증 환자에 있어서 Phase-Contrast Cine MRI 평가의 임상적 유용성)

  • Lim, Jeong-Hwan;Song, Jun-Hyeok;Shin, Kyu-Man;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1634-1641
    • /
    • 2000
  • Objective : The cerebrospinal fluid(CSF) pulsates within the craniospinal axis in response to rhythmic cerebral blood volume variation during the cardiac cycle. The aim of this study is to characterize the normal and abnormal CSF flow and its waveforms in the cervical spinal subarachnoid space. Methods : The magnetic resonance(MR) images were obtained with 1.5 T(GE Signa, GE Medical Systems, Milwaukee, USA) unit using the 2 dimensional cine PC(phase contrast) sequence with cardiac gating and gradient recalled echo imaging. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle. Sagittal and axial images of the cervical spinal CSF space were obtained, and target sites were analyzed for characteristic CSF flow (TR=50ms, TE=12.5-15ms). The region of interest(ROI) was 1mm 3 in volume. Twenty six persons were included in this study : 10 healthy volunteers and 16 patients with cervical myelopathy. The post-operative cine MR study were also done in five patients. Results : The normal CSF pulsation dynamics in the cervical spine showed discrete systolic and diastolic components. The CSF flow revealed a sine wave pattern, in which the systolic phase was shorter than the diastolic phase(ratio=2 : 3). The patient group revealed decreased amplitudes of the CSF flow and irregularly distored flow waves. The systolic phase was elongated in the ROI above the stenotic level, whereas the diastolic phase was lengthened below the level. In the postoperative images, the abnormal pattern and amplitude were found to be corrected. Conclusion : From these results, the authors believe that the CSF flow study provides valuable informations regarding the extent of cervical stenosis and may be useful for the surgical planning and post-operative evaluation.

  • PDF

Characteristic Analysis of Poly(4-Vinyl Phenol) Based Organic Memory Device Using CdSe/ZnS Core/Shell Qunatum Dots

  • Kim, Jin-U;Kim, Yeong-Chan;Eom, Se-Won;No, Yong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.289.1-289.1
    • /
    • 2014
  • In this study, we made a organic thin film device in MIS(Metal-Insulator-Semiconductor) structure by using PVP (Poly vinyl phenol) as a insulating layer, and CdSe/ZnS nano particles which have a core/shell structure inside. We dissolved PVP and PMF in PGMEA, organic solvent, then formed a thin film through a spin coating. After that, it was cross-linked by annealing for 1 hour in a vacuum oven at $185^{\circ}C$. We operated FTIR measurement to check this, and discovered the amount of absorption reduced in the wave-length region near 3400 cm-1, so could observe decrease of -OH. Boonton7200 was used to measure a C-V relationship to confirm a properties of the nano particles, and as a result, the width of the memory window increased when device including nano particles. Additionally, we used HP4145B in order to make sure the electrical characteristics of the organic thin film device and analyzed a conduction mechanism of the device by measuring I-V relationship. When the voltage was low, FNT occurred chiefly, but as the voltage increased, Schottky Emission occurred mainly. We synthesized CdSe/ZnS and to confirm this, took a picture of Si substrate including nano particles with SEM. Spherical quantum dots were properly made. Due to this study, we realized there is high possibility of application of next generation memory device using organic thin film device and nano particles, and we expect more researches about this issue would be done.

  • PDF

Characteristic Study of the Pulse Position on CHON, KWAN and CHUCK Using the Ultrasonic Waves (초음파 분석을 이용한 촌관척 위치별 혈관의 특성연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Ryu, Hyun-Hee;Choi, Eun-Ji;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-117
    • /
    • 2007
  • The study aims to measure and analyze the thickness and depth of blood vessel on the pulse diagnosis locations and the blood velocity through the use of ultrasonic waves (LOGIQ5PRO, GE Medical, U.S.) in order to understand the structural difference of pulse diagnosis locations. The subjects included 44 healthy men and women(22.28${\pm}$2.62 age) considered normal in terms of Body Mass Index(BMI). The thickness and depth of the blood vessel and the blood velocity were measured three times on CHON, KWAN and CHUCK to obtain the average value. Results showed there is a statistically significant difference among the variables measured on CHON, KWAN and CHUCK. A difference according to gender was also observed. This explains why an oriental medical doctor can tell the difference in pulses depending on the location of CHON, KWAN and CHUCK. In addition, the difference in pressure between CHON and KWAN was higher than that in pressure between KWAN and CHUCK. The findings explain why oriental medical doctors take pulses by dividing CHON, KWAN and CHUCK in the short length of the three fingers. It can be used to develop a pulse diagnosis device enabling accurate measurement according to the characteristics of blood vessel structure based on where the pulse is taken. Furthermore, the results can be used as basic data for the development of a pulse diagnosis simulator.

  • PDF

Wide-band design of X-cut $LiNbO_{3}$ optcal modulator employing a ridge waveguide (Ridge형 도파로구조 X-cut $LiNbO_3$ 광변조기의 광대역 설계)

  • Huh, Hyun;Kim, Hee-Ju;Pan, Jae-Kyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.1
    • /
    • pp.89-95
    • /
    • 1997
  • X-cut y-propagation $LiNbO_{3}$ optical modulator is analyzed by finite element calculation. the purpose of this trial is the design of wide-bandwidth x-cut $LiNbO_{3}$ optical modulator with ridge wave guide, which was only applied to z-cut $LiNbO_{3}$ optical modulator. the simulation tool is examined by the comparison between our results and Becker's. And we consider the optimum position of optical waveguide to electrodes for decreasing the driving voltage. The calculated driving-voltage, characteristic impedance and microwave effective index at $1.3{\mu}{\textrm{m}}$ optical wavelength are 18 V.cm, $48.13{\Omega}$ and 2.168, respectively.

  • PDF

Study on the Accuracy Improvement for Survey of Estuary Riverbed (하구하상 측량 정밀도 향상에 관한 연구)

  • 박운용;김천영;김용보
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.2
    • /
    • pp.137-145
    • /
    • 2003
  • Currently, the availability of 3-D topographical survey by combination of GPS and Echo Sounder has been increased in the various field like as the construction of structure, the dredging and the reclamation in the ocean and river, and observation of topographic change in seabed or riverbed. In this case, the error of depth sounding can divide in form that is happened by combination of GPS and Echo Sounder, and form that is happened in Echo Sounder itself, In this study, in the case happen by Echo Sounder itself, analyzed error by specially about geological features of the seabed and riverbed that is specular surface of sound wave and wished to present solution way. The sounding error about the echo sounder and characteristic of estuary riverbed was found by understanding the relation of average diameter and residual error and we defined correction formula, Y=-0.00474$^{*}$In(X) -0.0045 by the regression analysis. and then we verified applicability of correction formula. As the result, if measure Preliminary investigation or pre-survey the geological features for the survey area at topographical survey of estuary riverbed, we presented the error correction formula that estimate and can correct of error by Echo Sounderer.

Analysis of Pulse Wave Parameters According to Aging for Arteriosclerosis Evaluation (동맥경화 평가를 위한 연령별 맥파 주요인자 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Soo-Byeong;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.79-89
    • /
    • 2011
  • Objectives : The aim of this study is to propose the W area of pulse (AW) as a new index which can confirm the arteriosclerosis by analyzing parameters of 5-level pressure pulse waveform measurement system for normotensive group according to aging. Methods : We measured radial pulse waveforms of normotensive group (20 to 60 years old) using 3-dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea). And then we analyzed various parameters for sclerosis of the arteries such as Height (h1, h2, h3, h4, h5), Time (t1, t2, t3, t4, t5), AW, AW rate, Total area of pulse (At) and Augmentation Index (AIx). Results : As a result of analyzing parameters according to the aging, h2, h3, AS (systolic area rate to AT), AIx and AW were increased but t2/t, t3/t, t5/t and AD (diastolic area rate to AT) were decreased. Conclusions : We checked blood vessel conditions for normotensive group according to aging and confirmed various parameters. Also, we found that AW was analogous to AIx which has been used for diagnosing arteriosclerosis. Furthermore, we confirmed the usefulness of AW as a new parameter for checking vessel condition and characteristic compared with the AIx.

Evaluation of Aseismic Performance for Reservoir Dams in Korea (국내 저수지 댐의 내진 성능 평가)

  • Park, Innjoon;Kim, Seungwook;Jang, Woonghee;Kim, Hyuntae;Yoo, Chanho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.89-100
    • /
    • 2006
  • Recently, lots of lives and properties have been lost because comparatively large magnitude earthquakes were occurred in relatively safe regions and nations. It has been reported that number of earthquakes was increased rapidly in Korea. Hence, recently civil constructions were ensured against risks about earthquake not only large-scale structures but also comparative small-scale structures such as reservoir dams and life line by systematic aseismic design. Therefore, in this study, the seismic stability was ensured to evaluate aseismic performance for major planned reservoir dams in Korea. The seismic response analyses were conducted using SHAKE program on new reservoir dams under short-period, long-period and artificial seismic wave. The liquefaction potential for reservoir dams was assessed by using results from seismic response analysis (simplified assessment method for liquefaction potential). Also, fully coupled analysis--interaction of pore-pressure and soil--was performed to investigate both the development of excess pore water pressure and the characteristic of dynamic shear strain.

  • PDF