• Title/Summary/Keyword: Waterproofing system

Search Result 133, Processing Time 0.02 seconds

Correction of the Ground Subsidence Risk Ratings during Open Cut Excavation (개착식 굴착공사 중 지반함몰 위험등급 분류시트의 등급 보정에 관한 연구)

  • Shin, Sang-Sik;Kim, Hak Joon
    • The Journal of Engineering Geology
    • /
    • v.31 no.2
    • /
    • pp.135-148
    • /
    • 2021
  • Ground subsidence risk ratings obtained from the site investigation during pre-excavation stages could be changed depending on the parameters revealed during construction activities. A method of correcting the pre-excavation ground subsidence risk ratings based on the site conditions observed in the field is suggested in this study. The elevation of groundwater table during the excavation may be different from the predicted value depending on the application of waterproofing methods and construction conditions. The drastic drawdown of groundwater table during the excavation could cause ground subsidence due to soil volume decrease related to consolidation or compression of the ground, whereas the rising of groundwater table caused by the intense rainfall may result in a high potential for ground subsidence due to heaving or boiling of the excavation bottom. Excessive displacements of retaining walls or ground settlements may cause ground subsidence, which also results in a high risk of ground subsidence caused by the destruction of buried pipelines. Reevaluation of ground subsidence risk ratings is suggested considering the fluctuation of groundwater table, condition of groundwater leakage, measured ground displacements, and soil types. Finally, the ground subsidence risk rating system is improved for better evaluation by using 12 factors in 5 categories.

A Study on the Compositional Characteristics of Water Systems and Landscapes in Traditional Chinese Seowons (중국 전통서원의 수체계와 수경관의 구성적 특성)

  • MA, Shuxiao;RHO, Jaehyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.3
    • /
    • pp.74-100
    • /
    • 2022
  • The purpose of this study was to investigate the characteristics of Chinese seowons and to obtain data based on the characteristics of waterscapes unique to Korean seowons. The conclusion of this study from the results of investigation and analysis of the location, water system, and design characteristics of 10 representative traditional seowons in China including Yuelu Seowon(嶽麓書院) conducted based on literature research and field observation is as follows. The water system of Chinese seowons is dualized into an inner and an outer water system, and in general, two and a maximum of three water bodies are superimposed on the outside. The locations of seowons are classified into five types: Four double-sided round water type sites, three converted face water type sites, one three-sided round water type site, a four-sided round water type, and a waterproofing type(依山傍水型). Therefore, compared to the typical Korean seowon facing water in the front and a mountain in the back(背山面水型), the Chinese seowons showed a highly hydrophilic property. The water shapes of the external water system were meandering(46.0%), mooring(36.0%), and broad and irregular(9.0%). In addition, water conception(水態) were streams(31.8%), rivers(27.3%), springs(13.6%), falls(9.1%), lakes(4.5%) and ponds(4.5%), in that order. As for waterscapes of the water system inside the seowon, there were seven in Akrok Seowon and four in Mansong Seowon, indicating a comparatively higher number of waterscapes. Since the 27 detailed waterscapes in 10 seowons that were the subject of the study were classified into six types including ponds and half-moon ponds, they appeared to be more diverse than the Korean seowon. It is noteworthy that in the interior waterscape of the traditional Chinese seowon, the ritualistic order, where at least one half-moon pond or square pond(方池) was arranged, is well displayed. In particular, the half-moon pond(伴池), which is difficult to find in Korean seowon, was found to be a representative waterscape element, accounting for 42.8%. If the square pond of Nanxi Seowon based on Zhu Xi's poem 「Gwanseoyugam(觀書有感)」 is also treated as a square-shaped half-moon pond, the proportion of half-moon ponds in the waterscape will be as high as 50%. The pond shapes consisted of 28% square, 24% each for free curve and round shape, 20% for semi-moon shape, and 3.8% for mountain stream type. This seems to differ greatly from the square-shaped Korean seowon. On the other hand, there were a total of 10 types of structures related to the waterscape inside the Chinese seowon: 11(26.8%) pavilion and bridge sites, five gate room sites(牌坊: 16.5%), four gate and tower sites(樓, 1.4%), two Jae sites(齋, 6.2%), and one site each(3.1%) of Heon(軒), Sa(祠), Dae(臺), and Gak(閣). In particular, the pavilions inside seowon were classified into three types: landscape pavilion(景觀亭 27.2%), tombstone pavilion(碑亭, 18.2%), and banquet pavilion(宴集亭, 54.5%). In general, it was confirmed that the half-moon pond with a pedestal bridge, and the pavilion were the major components with a high degree of connection that dominate the waterscape inside the Chinese seowon.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF