• Title/Summary/Keyword: Water-proof

Search Result 185, Processing Time 0.027 seconds

Pro-environmental Maintenance and Management of Tour Cave : The Currents, Problems and Alternatives in Korea (관광동굴의 환경친화적 관리 방안에 관한 연구)

  • 유영준;이경호
    • Journal of the Speleological Society of Korea
    • /
    • v.59
    • /
    • pp.21-36
    • /
    • 1999
  • Most scholars calssify caves into natural resource, but caves possess values of natural and human resource, mix up the features of natural resources and human resources. Now, caves are distributed 260 in Korea. Seongryu Cave is showed in 1967 for the first time, till 1997 12 caves is opened to tourist. But since 1996 the 12 show caves of all is not launched the safety and environment-protection check-up adduced reason for IMF. Then caves must maintain environment of the normal temperature, humidity and dark. But the environment of caves are destroyed by tourism development. Thus to maintain environment of caves, it used to consider the counterplan as follows in restraint of the environmental change. Firstly, in case of development work to open caves, it must keep up with the prototype. Secondly, it must establish a freight depositary to prevent the influence of the caves's stain and damage due to tourist's objects. Thirdly, to maintain the normal temperature and humidity, it must install artificial poultice equipment of the inner parts of caves. Fourthly, in order to prevent the occurrence of $CO_2$, it must assessment of the optimum number of the greatest stayer. Fifthly, the control of closure for a given period of time is useful of the restoration to the cave's original state. Sixthly, by means of make narrow entrance, it should not influence the outer's air on the inner parts on caves. Seventhly, to keep the temperature of the inner part of caves, the lightening should be maintained moderately considering the convenience of a tour. Eightly, when water-proof cables for the lightening bulbs are connected each other, silicon tape is suitable and circuit breakers should be installed at the diverging points of the cables. Ninthly, the direction and angle of the lightening must be changed periodically to prevent green-pollution at the lightening spot. Lastly, when facilities and arrangements are equipped, corrosive materials should be excluded if circumstances allow.

  • PDF

A Design of the Cat's Eye System with Low Power Consumption Using Solar Energy (태양광을 이용한 저전력의 LED 표지병 설계)

  • Kim, Keun-Sik;Kim, Jong-Hoon
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.181-187
    • /
    • 2016
  • Typical Retro-reflectors installed on road have problems such as limiting a driver's visibility at night when it is foggy or rainy. On the other hand, LED illuminated studs, called cat's eye system, extends a driver's visibility under these conditions. In this paper, we present a design of the LED cat's eye system using solar energy that can sustain vehicles with about 30-ton weight and is compliant with the IP68 code for water proof as IEC standard 60529. In addition, we propose a scheme of designing a LED driving circuit consuming low power to take into accounts cold weather or rainy season with limited sunlight. This LED cat's eye studs is currently installed and used on expressway and bike route nationally as well as overseas.

Corrosion Resistance Characteristics of Cold Rolled Steel by Cr-free Green Organic/Inorganic Hybrid Coating Solution (크롬 프리 친환경 유/무기 하이브리드 코팅액에 의한 냉연강판의 내식특성)

  • Nam, Ki Woo;Kim, Jung Ryang;Choi, Chang Min
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.33-38
    • /
    • 2013
  • In the past, a very popular method for reducing the corrosion on zinc involved the use of chemical conversion layer coatings based on $Cr^{+6}$. However, there is an important problem with using chromium salts as a result of restrictive environmental protection legislation. This study investigated the optimum condition for galvanized steel using an organic/inorganic solution with a Ti composition. In the case of a fixed heat treatment time, the corrosion resistance values of LR-0727(1) and LR-0727(2) were improved as the heat treatment temperature increased, and the optimum minimum temperature decreased with the heat treatment time. At the optimum heat treatment condition of two coating solutions, the heat treatment time of the LR-0727(1) solution was shorter than LR-0727(2) for the same heat treatment temperature. LR-0727(1) coated specimens did not show desquamation, and all of the specimens showed a good adhesive property. In contrast, in the case of the LR-0727(2) coated specimens, desquamation arose. Therefore, the adhesive property of LR-0727(1) was superior to that of LR-0727(2). The pencil hardness had a 3H average for all of the coating solutions and heat treatment conditions. In the case of a corrosion resistance test with boiling water, the coated specimens of LR-0727(1) were discolored, but LR-0727(2) was not. Finally, LR-0727(1) was more moisture proof than LR-0727(2).

Characteristics of HFIX Insulated Wire Sheaths Contaminated by Pollutants (오염물질에 따른 HFIX 절연전선 피복의 특성 변화에 관한 연구)

  • Choi, Su-Gil;Nam, Yeong-Jae;Jin, Se-Young;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.8-17
    • /
    • 2020
  • In this study, the characteristics of HFIX insulated wire sheaths contaminated by pollutants were examined. KS C IEC 60811-1-3 standard was followed in performing the water-resistance wire tests. Pollutants were selected, and the specimens were exposed to the pollutants for a maximum duration of four weeks. The maximum tensile load and the elongation rate were measured each week. As the period of pollution exposure increased, the maximum tensile load of the specimens decreased by 6.22% and 6.52% at room temperature and high temperature, respectively, and 19.94% for specimens coated with a rust-proof lubricant. The elongation rate also decreased rapidly, such that the reductions in the properties of the sheath were significant. From the analysis of the surfaces using a scanning microscope, as the contamination period increased, structural changes such as perforation, split, and melting occurred, and the mechanical properties of the specimens decreased. Therefore, it is necessary to develop and follow an inspection cycle and periodically carry out repairs to prevent the deterioration of insulated wires.

A Study on High Strength Concrete of Concrete Filled Steel Tube Column (CFT 기둥용 초고강도 충전콘크리트에 관한 연구)

  • Jung, Keun-Ho;Lim, Nam-Gi;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.127-132
    • /
    • 2004
  • CFT(Concrete Filled Steel Tube) is a structure of circular or squared of steel column filled with concrete. The steel tube holds the concrete inside and that makes this structure to perform superior features on stiffness, proof stress, transformation, fire resistance and construction itself. In this study, by over the 800kgf/$\textrm{cm}^2$ of high strength concrete for CFT column, research has been done on the basic property of matter such as fluidity, resistance on segregation, compressive strength, setting icons of the concrete filled in the steel tube under conditions of standard weather. Physical properties of concrete for CFT that Concrete with silica fume, fly ash of air entraining and high-range water reducing agent, that used to CFT column research purpose to find the most ideal composition, which is achieved by the investigation in the concrete's property of matter like ability of Slump, Slump Flow, Air content, Bleeding, and Settlement. For this study, experiments which are bused on obtained the result through physical test are practiced, with all of the experiment, specimens only for control are produced in each method of curing and analyzed to relations with core strength in mock-up test. In mock-up test, the research is studied compactability of concrete filled in tube and degree of hydration hysteresis, as a basic reference for applying to field of CFT column which is used over 800kgf/$\textrm{cm}^2$ high strength concrete.

IoT based smart reporting and mooring system for vessels (IoT 기반의 선박용 스마트보고 및 계류 시스템)

  • Ahmadhon, Kamolov;Park, Su-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.395-398
    • /
    • 2017
  • The Smart Ship is considered one of the most discussed and novel topics in developing technological period. In this reason, the amount of running researches on it is evolving so fast. As a proof, the faced drawbacks such as the departure of ships, their safety, exchanging data, traffic and data monitoring system are being solved by presenting advanced technologies and innovations like Cloud, BigData, IoT and etc. Expanding the utilization of these technologies in the Marine world emphasizes not only the departure of the ships in the water but also they focus on solving the problems of the ships connected with the communication to the ports. In this paper, we present an IoT based smart reporting and mooring system for vessels and ports. In the proposed system, the ships automatically send all the data about themselves to the port and after getting the data, ports automatically send the information about possible spaces to moor for the ships using the sensors at the port. The intended system gives an amenity to minimize the time, effort and the cost while mooring the vessels.

  • PDF

Bonding Technologies for Chip to Textile Interconnection (칩-섬유 배선을 위한 본딩 기술)

  • Kang, Min-gyu;Kim, Sungdong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.1-10
    • /
    • 2020
  • This paper reviews the recent development of electronic textile technology, mainly focusing on chip-textile bonding. Before the chip-textile bonding, a circuit on the textile should be prepared to supply the electrical power and signal to the chip mounted on the fabrics. Either embroidery with conductive yarn or screen-printing with the conductive paste can be applied to implement the circuit on the fabrics depending on the circuit density and resolution. Next, chip-textile bonding can be performed. There are two choices for chip-textile bonding: fixed connection methods such as soldering, ACF/NCA, embroidery, crimping, and secondly removable connection methods like a hook, magnet, zipper. Following the chip-textile bonding process, the chip on the textile is generally encapsulated using PDMS to ensure reliability like water-proof.

Fabrication of Light-weight Ceramic Insulation Materials by Using Oxide Ceramic Fibers for Reusable Thermal Protection Systems (산화물 세라믹섬유를 이용한 재사용 열보호시스템용 경량 세라믹 단열소재의 제조)

  • Seongwon, Kim;Min-Soo, Nam;Yoon-Suk, Oh;Sahn, Nahm;Jaesung, Shin;Hyeonjun, Kim;Bum-Seok, Oh
    • Journal of Powder Materials
    • /
    • v.29 no.6
    • /
    • pp.477-484
    • /
    • 2022
  • Thermal protection systems (TPS) are a group of materials that are indispensable for protecting spacecraft from the aerodynamic heating occurring during entry into an atmosphere. Among candidate materials for TPS, ceramic insulation materials are usually considered for reusable TPS. In this study, ceramic insulation materials, such as alumina enhanced thermal barrier (AETB), are fabricated via typical ceramic processing from ceramic fiber and additives. Mixtures of silica and alumina fibers are used as raw materials, with the addition of B4C to bind fibers together. Reaction-cured glass is also added on top of AETB to induce water-proof functionality or high emissivity. Some issues, such as the elimination of clumps in the AETB, and processing difficulties in the production of reusable surface insulation are reported as well.

A Study on the Damages of Head Works by the Storm Flood in the Area of Cheong Ju and Boeun -Emphasis onFactors Influenced on the Disasters and their Countermeasures- (淸州 및 報恩地方의 頭首工洪水災害에 關한 調査硏究(II) -災害原因 및 對策方案을 中心으로-)

  • Nam, Seong-Woo;Kim, Choul-Kee
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.2
    • /
    • pp.49-55
    • /
    • 1982
  • The purpose of this study is to classify the factors influenced on the damages of head works suffered from the storm flood occurred on July 22 1980 in both Musim and Bochong rivers and to find out an integral counter measures against the causes influenced on the disaster of head works in the engineering aspect of planning, design, construction and maintenance. In this survey, number of samples was taken 25 head Works, and the counter measures against the causes of their disasters summarized was as follows, 1. In the aspect of planning a. As the flood water level after the establishment of head works is more increased than the level before setting of head works owing to having more gentle slope of river bed between the head works than nature slope of river bed. Number of head works should be reduced for the appropriate annexation of them b. In the place where head works is established on the curved point of levee, the destruction of levee becomes severe by the strong deflective current. Therefore the setting of head works on the curved point should be kept off as long as possible and in case of unavoidable circumstances the construction method such as reinforced concrete wall or stone wall filed with concrete and anchored bank revetments should be considered. 2. In the aspect of design a. As scoring phenomena at up stream is serious around the weir Where the concentration of strong current is present in such a place, up stream apron having impermeability should be designed to resist and prevent scoring. b. As the length of apron and protected bed is too short to prevent scoring as down stream bed, the design length should be taken somewhat more than the calculated value, but in the case the calculated length becomes too long to be profitable, a device of water cushion should be considered. c. The structure of protected river bed should be improved to make stone mesh bags fixed to apron and to have vinyl mattress laid on river bed together with the improvement for increasing the stability of stone mesh bags and preventing the sucked sand from the river bed. d. As the shortage of cut-off length, especialy in case of the cutoffs conneting both shore sides of river makes the cause of destruction of embankment and weir body, the culculation of cut-off length should be taken enough length based on seepage length. 3. In the aspect of design and constructions a. The overturing destruction of weir by piping action was based on the jet water through cracks at the construction and expansion joints. therefore the expansion joint should be designed and constructed with the insertion of water proof plate and asphalt filling, and the construction joint, with concaved shape structure and steel reinforcement. b. As the wrong design and construction of the weep holes on apron will cause water piping and weir destruction, the design and construction of filter based on the rule of filter should be kept for weep holes. c. The wrong design and construction of bank revetment caused the severe destruction of levee and weir body resulting from scoring and impulse by strong current and formation of water route behind the revetment. Therefore bank revetment should be designod and constructed with stone wall filled with concrete and anchored, or reinforced concrete wall to prevent the formation of water flow route behind the wall and to resist against the scoring and impulse of strong stream. 4. In the aspect of maintenance When the damaged parts occurred at head works the authorities and farmers concerned should find and mend them as soon as possible with mutual cooperation, and on the other hand public citizen should be guided for good use of public property.

  • PDF

Color and Carotenoid Changes During Storage of Dried Red Pepper (건조(乾燥) 고추 저장(貯藏) 중(中)의 변색(變色)에 관(關)한 연구(硏究))

  • Kim, Dong-Youn;Rhee, Chong-Ouk
    • Korean Journal of Food Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.53-58
    • /
    • 1980
  • The effects of water activity, oxygen, light and storage temperature on the color degradation of dried red pepper were investigated during storage. Some packing materials were used for improving the storage life of red pepper by minimizing those factors. The results obtained were summarized as follows: 1. The critical water activity to the capsanthin of red pepper was 0.75. 2. Color degradation of dried red pepper was the most severe by U.V. light among 100 watt infra-red lamp, 15 watt U.V. lamp and 200 watt glow lamp. 3. Effect of light was not significant in the presence of nitrogen, Main factor of color degradation of red pepper in storage appeared spontaneous oxidation by the existence of oxygen. 4. The capsanthin content and the lightness as hunter value in powder type storage of red pepper was higher than that in whole pod type during 3 month's storage. 5. The air and damp-proof packing materials showed better results than polyethylene film packing in capsanthin content and lightness during 3 month's storage.

  • PDF