• 제목/요약/키워드: Water-based bolus

검색결과 6건 처리시간 0.023초

사지의 방사선 치료에 사용하는 water bolus의 적용 시 치료부위의 위치 변화에 따른 방사선 선량분포의 민감도 연구 (A Study on Dose Sensitivity according to Position Variance in Extremities Radiation Therapy with Water Bolus)

  • 서정민
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.199-206
    • /
    • 2015
  • The purpose of this study was to investigate radiation dose sensitivity due to displacement of human extremities in the water bolus box on radiation therapy. Water bolus box and human thigh with femur bone were constructed in computerized radiation therapy planning system to verify the absorbed dose. Two 6MV X-ray beams were irradiated bilaterally into water bolus box and then radiation dose were calculated each situation at displacement of middle axis of thigh from the center in water bolus box to right and left direction. Absorbed dose of thigh and femur bone increased by the distance of displacement. The maximum dose of thigh even increased 20% over than prescribed dose. This is in contrast to conventional concept of dose distribution in water bolus box. Based on this result, displacement of body site in the water bolus box have to be averted during radiation therapy.

사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰 (Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients)

  • 안승권;김용배;이익재;송태수;손동민;장영재;조정희;김주호;김동욱;조재호;서창옥
    • Radiation Oncology Journal
    • /
    • 제26권3호
    • /
    • pp.189-194
    • /
    • 2008
  • 목 적: 본 연구팀은 사지에 발병한 카포시육종의 방사선치료를 위하여, 물볼루스를 사용할 수 있는 기구를 고안하였고, 쌀볼루스 사용시와 비교하여 유용성을 평가하고자 하였다. 대상 및 방법: 환자가 앙와위 자세에서 하지를 삽입 할 수 있는 폴리스틸렌 상자를 만들고 비닐 재질의 진공비닐을 집어 넣어 물이 누수 되지 않도록 결합하였으며, 진공비닐안에 하지와 물 사이의 공기를 없애기 위해 진공 밸브와 진공 펌프를 연결하여 공기를 제거하였다. 본 연구에서 제작한 물기반 볼루스의 선량 균질도를 비교 평가하기 위해 진공비닐에 하지 팬텀을 삽입한 후 폴리스틸렌 상자에 직접 쌀을 채운 경우, 비닐봉지에 쌀을 담아서 넣은 경우, 그리고 물을 직접 채운 경우에 대해 전산화단층촬영을 시행하였다. 방사선치료계획시스템을 사용하여 공기층의 부피에 의한 밀도의 변화를 분석하였다. 또한 선형가속기를 사용하여 전산화단층 모의치료기와 동일한 셋업에서 하지 팬텀에 필름을 감고, 열형광선량계 6개를 조사야 안에 균등하게 붙여서, 대향이문 조사하여 선량의 균질도 및 선량 값을 측정하였다. 결 과: 각 세 종류 실험의 밀도 측정결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 14% 감소했으며, 쌀을 비닐 봉지에 나누어 넣은 경우는 18% 감소하였다. 필름의 분석 결과 물볼루스가 쌀볼루스보다 균질도가 $4{\sim}4.4%$ 정도 우수한 것으로 나타났다. 열형광선량계 측정 평균값 분석결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 3.4% 증가했으며, 쌀을 비닐봉지에 나누어 넣은 경우는 4.3% 증가하였다. 결 론: 자체 제작한 물볼루스 기구는 육안으로 치료 조사야를 확인할 수 있어 셋업의 정확성을 높였으며, 진공 밸브와 진공 펌프를 사용하여 공기층을 감소시켜 치료의 정확성을 높이는 동시에 목적 종양에 균질도가 높은 선량을 부여 할 수 있는 좋은 방안이라 할 수 있다.

Assessing Commercial CLEANBOLUS Based on Silicone for Clinical Use

  • Son, Jaeman;Jung, Seongmoon;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.159-164
    • /
    • 2021
  • Purpose: We investigated the properties of CLEANBOLUS based on silicone with suitable characteristics for clinical use. Methods: We evaluated the characteristics of CLEANBOLUS and compared the results with the commercial product (Super-Flex bolus). Also, we conducted physical evaluations, including shore hardness, element composition, and elongation break. Transparency was investigated through the measured absorbance within the visible region (400-700 nm). Also, dosimetric characteristics were investigated with surface dose and beam quality. Finally, the volume of unwanted air gap was investigated based on computed tomography images for breast, chin, and nose using Super-Flex bolus and CELANBOLUS. Results: CLEANBOLUS showed excellent physical properties for a low shore hardness (000-35) and elongation break (>1,000%). Additionally, it was shown that CLEANBOLUS is more transparent than Super-Flex bolus. Dosimetric results obtained through measurement and calculation have an electron density similar to water in CLEANBOLUS. Finally, CLEANBOLUS showed that the volume of unwanted air gap between the phantom and each bolus is smaller than Super-Flex bolus for breast, chin, and nose. Conclusions: The physical properties of CLEANBOLUS, including excellent adhesive strength and lower shore hardness, reduce unwanted air gaps and ensure accurate dose distribution. Therefore, it would be an alternative to other boluses, thus improving clinical use efficiency.

Measurement of Age-Related Changes in Bone Matrix Using 2H2O Labeling

  • Lee, Jeong-Ae;Kim, Yoo-Kyeong
    • Preventive Nutrition and Food Science
    • /
    • 제10권1호
    • /
    • pp.40-45
    • /
    • 2005
  • Age-related changes in bone metabolism are well established by biochemical markers of bone matrix in serum and urine, but analysis of the residual bone matrix, which is still turning over, has not been investigated. In the present study, we measured in vivo rates of bone protein synthesis using a precursor-product method based on the exchange of ²H from ²H₂O into amino acids. Four percent ²H₂O was administered to mice in drinking water after intraperitonial (i.p) bolus injection of 99.9% ²H₂O. Mice were divided into the two groups: growing young mice were administered 4% ²H₂O for 12 weeks after an i.p bolus injection at 5 week of age, whereas weight stable adult mice started drinking 4% ²H₂O 8 weeks later than the growing group and continued 4% ²H₂O drinking for 8 weeks. Mass isotopomer abundance in alanine from bone protein was analyzed by gas chromatography/mass spectrometry. Body ²H₂O enrichments were in the range of 1.88-2.41% over the labeling period. The fractional synthesis rates (ks) of bone protein were 2.000±0.071%/d for growing mice and 0.243±0.014%/d for adult mice. These results demonstrate that the bone protein synthesis rate decreases with age and present direct evidence of age-related changes in bone protein synthesis.

Waveguide Applicator System for Head and Neck Hyperthermia Treatment

  • Fiser, Ondrej;Merunka, Ilja;Vrba, Jan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1744-1753
    • /
    • 2016
  • The main purpose of this article is a complex hyperthermia applicator system design for treatment of head and neck region. The applicator system is composed of four waveguides with a stripline horn aperture and circular water bolus. The specific absorption rate (SAR) and temperature distribution from this applicator in various numerical phantom models was investigated. For used targets, the treatment planning based on the optimization process made through the SEMCAD X software is added to show the steering possibilities of SAR and thereby temperature distribution. Using treatment planning software, we proved that the SAR and temperature distribution can be effectively controlled (by amplitude and phase changing) improving the SAR and temperature target coverage approximately by 20 %. For the proposed applicator system analysis and quantitative evaluation of two parameters 25 % iso-SAR and $41^{\circ}C$ iso-temperature contours in the treatment area with the respect to sensitive structures in treatment area were defined. To verify our simulation results, the real measurement of reflectivity coefficient as well as the temperature distribution in a homogenous phantom were performed.

카르보폴-젤라틴의 상분리법을 이용한 Acyclovir 마이크로캅셀 현탁액의 제조 및 생물학적 평가 (Biological Evaluation of Acyclovir Microcapsule Suspension Prepared by Carbopol-Gelatin Coacervation)

  • 조진호;한양희;이정우;최영욱
    • Journal of Pharmaceutical Investigation
    • /
    • 제23권3호
    • /
    • pp.139-144
    • /
    • 1993
  • Microencapsulation of acyclovir, an effective antiviral agent which acts as a specific inhibitor of herpes DNA polymerase, by carbopol-gelatin complex coacervation has been carried out to develop an oral controlled release preparation, which could improve the absorption characteristics in GI tract. After dissolving carbopol and gelatin separately in distilled water at $40^{\circ}C$, gelatin solution was mixed with carbopol solution while stirring at the same temperature. The pH of the mixture was lowered gradually by dropwise addition of 10% HCI with continuous stirring, and then, at pH 3.5, positively charged gelatin molecules were attracted to negatively charged carbopol. These coacervation processes were observed by optical microscopy during preparation. Plasma concentrations of acyclovir in rats after an oral administration of microcapsule suspension were assayed by HPLC, and pharmacokinetic parameters were calculated based on the model-independent analyses. Two standard formulations, oral solution and intravenous bolus injection, were used as references to compare the bioavailability. It has been revealed that $C_{max}$, $T_{max}$, and MRT of microcapsule suspension were greater than those of oral solution, which results in about two-fold increases in bioavailability. Therefore, in conclusion, the carbopol-gelatin microcapsule of acyclovir might be evaluated as an effective oral controlled release preparation which could increase the bioavailability of acyclovir.

  • PDF