• 제목/요약/키워드: Water-Oil-Air Flow

검색결과 36건 처리시간 0.027초

코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구 (An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter)

  • 임기원;이완규
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.

폴리카보실란 에멀젼의 동결건조를 이용한 다공체 SiC 제조 (Preparation of Porous SiC by Freeze Drying of Polycarbosilane Emulsion)

  • 황연
    • 한국재료학회지
    • /
    • 제26권6호
    • /
    • pp.320-324
    • /
    • 2016
  • Porous SiC beads were prepared by freeze-drying a polycarbosilane (PCS) emulsion. The water-in-oil (w/o) emulsion, which was composed of water, PCS dissolved p-xylene, and sodium xylenesulfonate (SXS) as an emulsifier, was frozen by dropping it onto a liquid $N_2$ bath; this process resulted in 1~2 mm sized beads. Beads were cured at $200^{\circ}C$ for 1 h in air and heat-treated at $800^{\circ}C$ and $1400^{\circ}C$ for 1 h in an Ar gas flow. Two types of pores, lamella-shaped and spherical pores, were observed. Lamellar-shaped pores were found to develop during the freezing of the xylene solvent. Water droplets in the w/o emulsion were changed into spherical pores under freeze-drying. At $1400^{\circ}C$ of heat-treatment, porous SiC was synthesized with a low level of impurities.

고온호기발효장치를 이용한 조류 분해 및 가스 발생특성 (The properties of algal degradation and gas emission by thermophilic oxic process)

  • 강창민
    • 유기물자원화
    • /
    • 제7권2호
    • /
    • pp.57-64
    • /
    • 1999
  • 본 연구는 고온호기발효법에 의해 미세조류(부영양화호에서 회수한)를 처리할 경우, 처리조건의 변화에 따른 지구온난화가스의 발생특성을 살펴, 가스억제를 위한 효과적 처리조건을 검토하는 것이다. 회분 및 연속실험을 실시하여, 이하의 결과가 얻어졌다. 회분실험에서는 폐식용유의 첨가유무 및 공기주입량에 따른 발효효과를 검토했다. 폐식용유 첨가의 경우, 발열량의 증가에 따라 처리물질의 수분증발에 효과적 이었다. 또 공기주입량의 변화에 따라, 유기물제거는 공기량이 100ml/min일 때 가장 효과적이었고, 발생가스중 $CO_2$는 실험초기에만 영향을 받았고, $N_2O$는 실험중 전혀 영향을 받지 않았다. 또 $CH_4$는 공기공급이 부족한 초기에 검지 되었으나, 그 후 발생되지 않았다. 연속실험에서 공기량을 100ml/min에 고정한 후,고분자응집제의 첨가유무 및 수분조정제의 종류에 따른 가스발생특성을 비교 검토했다. $N_2O$는 고분자응집제(PAC) 첨가 및 수분조정제의 종류에 의해 가스발생량에 영향을 받지 않았으나, $CO_2$의 경우는 약간의 영향을 받았다. $CH_4$는 검출되지 않았다.

  • PDF

저온에서 정방형 공간내 성층화된 유체의 열적거동에 관한 실험적 연구 (An Experimental Study on the Low-Temperature Behavior of Stratified Fluids in the Square Cavity)

  • 강한용;이동석;김병철
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.381-387
    • /
    • 2000
  • An experimental study on the stratified fluids was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in the square cavity. The same volume of water and silicon oil was filled in it. The experiments were performed with the variations of initial temperatures and cooling surface temperatures. And the effect of vertical or horizontal cooling surface positions in the square cavity was investigated. When the cooling surface temperatures were $-4^{\circ}C$ , the supercooling phenomena were observed for both cases of cooling surface positions in the full region regardless of the initial temperature of fluid. In the square cavity with horizontal cooling surfaces, the lower the initial temperatures were, the longer the supercooling durations were, and with vertical cooling surface the lower the initial temperatures were, the shorter the supercooling durations were.

  • PDF

Slim hole 경사 환형관내 고-액 혼합유동 특성에 관한 연구 (Solid-liquid mixture flow characteristics in an inclined slim hole annulus)

  • 서병택;한상목;우남섭;김영주;황영규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1315-1320
    • /
    • 2008
  • An experimental study was carried out to study the solid-liquid mixture upward flow in a vertical and inclined annulus with rotating inner cylinder. Lift forces acting on a fluidized particle plays a central role in many importance applications, such as the removal of drill cuttings in horizontal drill holes, sand transport in fractured reservoirs, sediment transport and cleaning of particles from surfaces, etc. Field measurements have revealed that the pressure drop over a borehole during drilling of a slim oil well or a well with a long reach can depend significantly on the rotation speed of the drill pipe. An accurate prediction of the annular frictional pressure drop is therefore important for conditions where the annular clearance is small. Effect of annulus inclination and drill pipe rotation on the carrying capacity of drilling fluid, particle rising velocity, and pressure drop in the slim hole annulus have been measured for fully developed flows of water and of aqueous solutions.

  • PDF

오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석 (Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor)

  • 김우영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성 (Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

수직 상향유동 배관에서 비뉴톤유체에 의한 2상류의 유동특성 (The Characteristics of Two Phase Flow by Non-Newtonian Fluid for Vertical Up-ward in a Tube)

  • 차경옥;김재근;최경석
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.53-59
    • /
    • 1998
  • 기-액 2상유동장에서 유동양식은 압력강하, 보이드율분포, 유동장의 기하학적 형상과 밀접한 관계가 있다. 한편 원유수송, 비등이 발생하는 유동, 펌프에서 발생하는 케비테션 현상, 그리고 화학 반응로와 같은 상변화 장치 등의 2상유동에서 고분자물질에 의한 저항감소 현상의 적용이 가능할 것으로 예상된다. 그러나 2상유동장에서 고분자물질에 의한 저항감소에 관한 연구는 매우 미비하다. 그래서 본 연구는 2상유동장에 합성고분자물질(A611p)에 의한 저항감 소율을 실험을 통하여 계측 및 분석하였다. 본 연구에서는 고분자물질의 농도를 증가시킬수록 국부보이드율의 최고치가 관의 중심에서 관의 벽쪽으로 이동하며 2상유동의 유동양식이 변화됨을 규명하였다. 그래서 저항감소율과 유동양식과 밀접한 관계가 있음을 예측할 수 있었다.

  • PDF

ERCO에 특수혼화제 첨가가 보통강도 모르타르의 품질에 미치는 영향 (Effect of Addition of Special Admixture to ERCO, on the Quality of Normal Strength Mortar)

  • 김태우;백철;이제현;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.75-76
    • /
    • 2017
  • In this study, it is speculated that the special admixture can be mixed with ERCO beforehand to prevent adsorption of cement and AE at the time of contamination together with water, and the change in the amount of special admixture preliminarily added to ERCO We will try to analyze the influence on normal strength mortar. As a result, the flow quantity, the air quantity, the compressive strength and the flexural strength were improved as the added amount of the special admixture was increased, and When the special admixture with the addition amount of ERCO 3% was added, the strength was rather lowered. Therefore, it was found that the optimum amount of special admixture added to ERCO was 2%.

  • PDF

초임계 $CO_2$의 헬리컬 코일관 내 열선단과 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of Supercritical $CO_2$ in a Helically Coiled Tube)

  • 유태근;김대희;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.353-358
    • /
    • 2005
  • The heat transfer and pressure drop of supercritical $CO_2$ cooled in a helically coiled tube was investigated experimentally. The experiments were conducted without oil in the refrigerant loop. The experimental apparatus of the refrigerant loop consist of receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section is a helically coiled tube in tube counter flow heat exchanger with $CO_2$ flowed inside the inner tube and coolant( water) flowed along the outside annular passage, It was made of it copper tube with the inner diameter of 4.55[mm]. the outer diameter of 6.35 [mm] and length of 10000 [mm]. The refrigerant mass fluxes were $200^{\sim}600$ [kg/m2s] and the inlet pressure of gas cooler varied from 7.5 [MPa] to 10.0 [MPa]. The main results are summarized as follows : The heat transfer coefficient of supercritical $CO_2$ increases, as the cooling pressure of gas cooler decreases. And the heat transfer coefficient increases with the increase of the refrigerant mass flux. The pressure drop decreases in increase of the gas cooler pressure and increases with increase the refrigerant mass flux.

  • PDF