• 제목/요약/키워드: Water treatment System

검색결과 2,437건 처리시간 0.031초

A Study of the Technical Treatment within an Environmental Appetency for the Ballast Water

  • Nam, Chung-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권8호
    • /
    • pp.1313-1323
    • /
    • 2004
  • In accordance with adoption of new convention for the control of ship's ballast water at the diplomatic conference held in London Feb, 2004, every country has to regulate the ballast water and deposit matters. When this Resolution comes into effect in 2009, all vessels engaged in international voyage must have ballast water control program, ballast water records, equipments which are suitable to the standard of exchange and performance for the ballast water. This study estimates objectively their performances, merits and demerits of the ballast water treatment technique and exchanging techniques for safe operation of ships. It is desirable to design an equipment to control the ballast water using the brush-type vacuum suction nonstop reverse cleaning system to overcome the clogging phenomenon and the direct disc filtering to maximize filtering area for the optimum process considering biological availabilities. It will be expected to protect against marine pollution and to maintain clean sea if it is secured to develop new ballast water treatment techniques. And it will also be expected to cope with the Resolution and each regulation of the developed countries from the ballast water.

수돗물 수질개선을 위한 배수관망시스템 관리 정책 - 수질모니터링을 중심으로 - (Monitoring of Distribution System to Improve Tap Water Quality)

  • 전제상;김자겸
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.411-420
    • /
    • 2005
  • Maintaining a good quality of drinking water produced through appropriate water treatment processes to the tap is as important as improving water quality in a water treatment plant (WTP). The quality of most tap water, however, does not have the same quality as that of the water produced in a WTP due to the contamination in the distribution system while they are delivered through pipes and water tanks. It is very important to maintain water quality in distribution system to water suppliers for consumer's health and safety. Furthermore, it is not possible to investigate the water quality of all points in the distribution system because the system has a wide area and very complex hydraulic characteristics. One economic solution to prevent water quality in distribution system from being deteriorated is monitoring several points that might have the least water quality in the distribution system. If the quality of water of the monitoring points selected by proper ways is better than the quality index of Drinking Water Quality Guidelines suggested by Korean Ministry of Environment, all other points in the distribution system would be safe to drink.

수돗물 신뢰도 향상을 위한 품질 인증 제도 도입 (Introduction of Water Quality Certification System for Confidence Improvement of Tap Water)

  • 김진근
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.155-163
    • /
    • 2015
  • Many advanced treatment processes have been introduced to WTPs, however, the consumer confidence on tap water is still low and the percentage of drinking water directly from the tap is less than 2 %. One of the methods to improve the credibility of tap water is to introduce a drinking water certification system. By introducing the system, water treatment processes can be optimized, which in turn, can significantly improve drinking water quality. In this paper, 6 water quality parameters(i.e., turbidity, CT, residual chlorine, geosmin, 2-MIB, Mn) which have significant influences on tap water quality and consumer confidence were identified, and their recommended guidelines were proposed. 3-Star or 5-Star certification can be awarded to the WTPs which have met the certification criteria. The drinking water certification system can be carried out as a voluntary program among drinking water suppliers.

마을단위 소규모 하·폐수처리 공정의 효율적 유지관리를 위한 전문가 시스템에 관한 연구 (An Innovative Expert System for the Maintenance of On-site Wastewater Treatment Process for Small-scale Residential and Commercial Sites)

  • 김승준;최용수;홍석원;권기한;정익재
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.132-140
    • /
    • 2005
  • The pilot test of a new alternative for small wastewater treatment system has been conducted for two years. It consists of a hybrid bioreactor and the expert system including the process control logic, PLC system, and HMI for the process automation. In order to monitor and remote control its status, the real-time data was transferred from the on-site control center to the central station via a wireless local area network. More efficient and stable performances were observed at automatic operating mode compared with the manual. On an average, COD, SS, T-N and T-P concentrations in the effluent from the hybrid bioreactor were less than 14, 7, 12 and 0.9 mg/L, respectively. According to the result from pilot tests, the quality of treated wastewater with sand filtration was enough to be utilized again.

DOF 공정에 의한 정수처리 효과 (Effect of Drinking Water Treatment by DOF(Dissolved Ozone Flotation) System)

  • 이병호;송원철
    • 대한환경공학회지
    • /
    • 제30권7호
    • /
    • pp.743-750
    • /
    • 2008
  • 본 연구에서는 용존오존부상법(Dissolved Ozone Flotation; DOF)을 이용한 정수처리 효과를 파악하기 위하여 적정 오존 주입 농도와 오존 주입 농도별 처리 특성에 대해서 연구하였으며, 또한 용존공기부상법(Dissolved Air Flotation; DAF) 및 중력식 침전법(Conventional Gravity Sedimentation; CGS)과 DOF의 처리 성능을 비교하였다. 최적 오존 주입 농도를 산정하기 위한 실험에서 최적 오존 주입농도는 2.7 mg/L로 나타났으며, 오존 주입 농도가 증가할수록 탁도 및 KMnO$_4$ 소모량, UV$_{254}$ 흡수도, TOC 등과 같은 제거효율이 낮아지는 것으로 나타났다. DOF와 DAF, CGS의 처리성능을 비교한 결과 오존 주입 농도 2.7 mg/L로 운전한 DOF시스템의 탁도 제거효율은 88.9%, 유기물질 항목의 경우 KMnO$_4$ 소모량은 62.9%, TOC 47%, 그리고 UV$_{254}$ 흡수도 77.3% 그리고 THMFP 제거율의 경우 51.6%로 다른 두 공정보다 높거나 비슷하게 나타났다. 따라서 응집 부상 공정과 오존 산화 공정이 하나의 반응기에서 일어나는 DOF 시스템은 정수처리시설의 소유부지 감소와 기존 CGS 시스템에서 처리가 어려운 조류 및 용존성 유기물질의 제거를 통해 소독부산물의 생성을 감소시킴으로 향후 고도정수처리시스템으로 적용 가능성이 충분한 것으로 판단된다.

콘크리트 표면처리방법에 따른 금속용사 피막의 투수성 평가에 관한 실험적 연구 (An Experimental Study on the Permeability Evaluation of Metal Spray System by Concrete Surface Treatment)

  • 박진호;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.34-35
    • /
    • 2015
  • Recently, introduction of Advanced water treatment facilities has been increasing due to serious domestic water pollution. Ozone is a strong oxidizing materials in the advanced water treatment facilities. However, due to such a strong oxidation, Ozone eroded waterproofing/corrosion on the concrete surface and caused performance degradation. Therefore, in this study, permeability experiment of metal spraying system by concrete surface treatment was conducted.

  • PDF

Life Cycle Assessment (LCA)를 적용한 오니집약처리(汚泥集約處理)의 평가(評價) (Life Cycle Assessment (LCA) on Intensive Sludge Treatment System)

  • 황용우;권봉기;서성원
    • 상하수도학회지
    • /
    • 제12권3호
    • /
    • pp.65-74
    • /
    • 1998
  • Life cycle assessment (LCA) on two different sludge treatment systems, on-site treatment and pipe-collected intensive treatment was performed to estimate the environmental impact in the aspect of global warming effect. As a main parameter of the estimation, $CO_2$ was chosen and quantified through the whole life cycle of the treatment systems including construction, operation and dismantlement. In this study, the changes of $CO_2$ production unit (CPU) by up-scaling n currently used sludge treatment processes were also calculated. As the result, a larger amount of $CO_2$ was exhausted from the construction step of intensive treatment system than that of on-site treatment system, because an additional pipe-collection system was needed in intensive treatment system. However, the total amount of $CO_2$ exhausted from whole life cycle including not only construction and dismantlement but also 15 year-operation and maintenance was reduced by appling intensive treatment.

  • PDF

Water Treatment of High Turbid Source by Tubular Ceramic Microfiltration with Periodic Water-back-flushing System

  • Lee, Hyuk-Chan;Park, Jin-Yong
    • Korean Membrane Journal
    • /
    • 제9권1호
    • /
    • pp.12-17
    • /
    • 2007
  • We performed periodic water-back-flushing using permeate water to minimize membrane fouling to enhance permeate flux in tubular ceramic microfiltration system for water treatment of high turbid source. The filtration time (FT) = 2 min with periodic 6 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume $(V_T)\;=\;6.805L$. Also in the result of BT effect at fixed FT = 10 min and BT (back-flushing time) = 20 sec showed the lowest value of $R_f$ and the highest value of $J/J_o$, and we could obtain the highest $V_T\;=\;6.660\;L$. Consequently, FT = 2 min and BT = 6 sec could be the optimal condition in water treatment of high turbid source above 10 NTU. However, FT = 10 min and BT = 20 sec was superior to reduce operating costs because of lower back-flushing frequency. Then the average quality of water treated by our tubular ceramic MF system was turbidity of 0.07 NTU, $COD_{Mn}$ of 1.86 mg/L and $NH_3-N$ of 0.007 mg/L.

토양/대수층 처리를 이용한 깨끗하고 안전한 도심하천 유지용수 확보 기술 (Application of soil aquifer treatment to secure clean and safe river water in urban watershed)

  • 김정우;차성민;최희철
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.409-411
    • /
    • 2008
  • Water conveyance from waste water treatment plant can play a role in securing river water quantitatively in urban watershed, but it can also cause more severe contamination of river water due to lack of water quality management. Soil aquifer treatment(SAT) has been introduced to overcome the worsening water quality in the water conveyance system considering the characteristics of Korean urban watershed. The application of SAT to the water conveyance system not only improve water quality of ordinarily discharged water but also prevent accidential water pollution to the urban watershed. Since most domestic urban watersheds are consist of narrow terrace lands and surrounded by roads, SAT is estimated not to be appropriate to the urban watershed with respect to the quantitative efficiency. However, since the upstream of urban watershed in which discharge ports are located usually consists of agricultural lands, SAT can be applied near discharge ports. Therefore, combination of water conveyance and SAT is expected to supply clean and safe river water in urban watershed.

  • PDF

Towards a novel approach to improve drinking water quality at Dhaka, Bangladesh

  • Serajuddin, Md.;Chowdhury, Md. Aktarul Islam
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.136-142
    • /
    • 2018
  • The river water source of Saidabad Surface Water Treatment Plant at Dhaka, Bangladesh, is deteriorated too much to be treated by conventional treatment process due to excessive ammonia pollution. In order to improve the raw water quality before it enters into the main treatment chain, a pilot study was conducted for pre-treatment of the raw water. The objective is to investigate the rate of reduction of ammonia using the Meteor pilot, a biological pretreatment system, which is a laboratory scale Moving Bed Biofilm Reactor with a nominal volume of hundred liters, filled with 50 L of Meteor 660 media. The reduction of ammonia was quite significant on average 73%, while the reduction of COD was in a range from 20 to 60%. The Meteor pilot was able to treat and nitrify the raw water and produce an effluent that respects the guarantee of ammonia < $4.0mg\;NH_3-N/L$ when the raw water ammonia concentration was < $15mg\;NH_3-N/L$. The study identified operating parameters necessary to achieve the desired goal of adequate ammonia removal. The study results would benefit a range of systems across the country by providing guidance on the design and operation of a biological pre-treatment system for ammonia removal.