• 제목/요약/키워드: Water treatment

검색결과 12,071건 처리시간 0.044초

목질바이오매스의 초임계수 처리에 의한 리그닌의 화학적 변환 (The effect of supercritical water treatment on the chemical variations of lignin)

  • 이수민;이오규;최석환;최준원;최돈하
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.206-209
    • /
    • 2008
  • The modified supercritical water treatment method is adopted for hydrolysis of wood powder, Populus alba$\times$glandulosa. This modified method is containing 0.05% HCl or $HNO_3$ as acid catalyst. The supercritical water treatment(SCW) was performed for 1 min. with $350^{\circ}C$, $380^{\circ}C$, $400^{\circ}C$ and $425^{\circ}C$, respectively, under 230 $\pm$ 10 atm using continuous flow system. When acid was added to powder prepared for SCW treatment, the yields of monomeric sugars were significantly increased. The lignin remained after supercritical treatment was applied to gel permeation chromatography(GPC) for molecular weight distribution analysis. Compared to the lignin produced from SCW treatment without acid catalyst, the average molecular weight of lignin compounds treated with acid was clearly decreased. Particularly, Mn/Mw ratio is decreased. This result shows supercritical water treatment of wood powder can change the molecular weight of lignin to small size. However, it is necessary to be further studied for exactly characterizing the lignin produced from supercritical water treatment.

  • PDF

낙동강 수계 페놀처리를 위한 정수처리시스템 평가 (Evaluation of Water Treament System for Phenol Removal in the Nakdong River Basin)

  • 강병재;채선하;이경혁;전항배
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.609-618
    • /
    • 2009
  • Repeated phenol spill in the Nakdong River has been a big issue in Korea since 1991. In this study, treatment of phenol in each water treatment process and total water treatment system is evaluated. Phenol was highly volatile, easily oxidized by ozone, and readily absorbed onto GAC. When there was phenol of 0.3mg/L in water, by ozonation of 1mg/L or by GAC adsorption with EBCT of 10minutes or longer, it could be treated to lower than 0.005mg/L, the national drinking water standard of phenol. Even when a sufficient contact time(70minutes) was allowed, only 35 to 40% of phenol could be removed by powdered activated carbon(PAC). Based on the test results, it can be concluded that 1.0mg/L or less concentration of phenol can be treated at the plants adopting the combination process of ozone and GAC down to the safe level. In this study, removal characteristics for phenol were evaluated with the existing pilot plant and demo plant in different advanced water treatment processes(AWTPs). In the future, studies on changes in oxidation and adsorption characteristics caused by competitive matters such as DOC and removal characteristics by other various AWTPs including ozone/filter adsorber need to be performed.

부유식 수처리시스템용 축류펌프의 성능 및 내부유동 (Performance and Internal Flow Characteristics of an Axial Flow Pump for a Floating Type Water Treatment System)

  • 패트릭마크싱;최영도
    • 한국유체기계학회 논문집
    • /
    • 제17권3호
    • /
    • pp.52-58
    • /
    • 2014
  • The development of efficient systems for water quality improvement for water sources such as lakes, dams and reservoirs has become a necessity to provide not only a cleaner and safer water to the urban society, but also to provide a cleaner and safer environment for the aquatic organisms living in lakes, dams and reservoirs. This study concentrates on the outlet design and internal flow analysis of an axial flow pump used in a floating type water treatment system completely powered by renewable energy source. The treatment system is designed to raise water from depths of about 3~5m up to the water surface where it is naturally mixed with air as it is released back to the reservoir. The outlet of a typical axial flow pump is modified to suit the floating type water mixer. The performance of the axial flow pump is studied by investigating the internal flow of the system. Results show that the change in outlet shape does not alter the performance of the original pump at the maximum efficiency point as long as the cross sectional area of inlet is the same as the outlet. The axial pump for floating type water treatment system has good cavitation performance in the whole flow passage.

Design of In-situ Self-diagnosable Smart Controller for Integrated Algae Monitoring System

  • Lee, Sung Hwa;Mariappan, Vinayagam;Won, Dong Chan;Shin, Jaekwon;Yang, Seungyoun
    • International Journal of Advanced Culture Technology
    • /
    • 제5권1호
    • /
    • pp.64-69
    • /
    • 2017
  • The rapid growth of algae occurs can induce the algae bloom when nutrients are supplied from anthropogenic sources such as fertilizer, animal waste or sewage in runoff the water currents or upwelling naturally. The algae blooms creates the human health problem in the environment as well as in the water resource managers including hypoxic dead zones and harmful toxins and pose challenges to water treatment systems. The algal blooms in the source water in water treatment systems affects the drinking water taste & odor while clogging or damaging filtration systems and putting a strain on the systems designed to remove algal toxins from the source water. This paper propose the emerging In-Situ self-diagnosable smart algae sensing device with wireless connectivity for smart remote monitoring and control. In this research, we developed the In-Site Algae diagnosable sensing device with wireless sensor network (WSN) connectivity with Optical Biological Sensor and environmental sensor to monitor the water treatment systems. The proposed system emulated in real-time on the water treatment plant and functional evaluation parameters are presented as part of the conceptual proof to the proposed research.

Recirculating Aquaculture System Design and Water Treatment Analysis based on CFD Simulation

  • Juhyoung Sung;Sungyoon Cho;Wongi Jeon;Yangseob Kim;Kiwon Kwon;Deuk-young Jeong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권11호
    • /
    • pp.3083-3098
    • /
    • 2023
  • As demands for efficient and echo-friendly production of marine products increase, smart aquaculture based on information and communication technology (ICT) has become a promising trend. The smart aquaculture is expected to control fundamental farm environment variables including water temperature and dissolved oxygen (DO) levels with less human intervention. A recirculating aquaculture system (RAS) is required for the smart aquaculture which utilizes a purification tank to reuse water drained from the water tank while blocking the external environment. Elaborate water treatment should be considered to properly operate RAS. However, analyzing the water treatment performance is a challenging issue because fish farm circumstance continuously changes and recursively affects water fluidity. To handle this issue, we introduce computational fluid dynamics (CFD) aided water treatment analysis including water fluidity and the solid particles removal efficiency. We adopt RAS parameters widely used in the real aquaculture field to better reflect the real situation. The simulation results provide several indicators for users to check performance metrics when planning to select appropriate RAS without actually using it which costs a lot to operate.

상하수처리용 교반기의 설계 방법 연구 (A Study on the Design Method of Mixers for Water&Sewage water treatment)

  • 이혜영;주윤식;강문후
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.427-430
    • /
    • 2003
  • The Mixers is used for the Mixing which is the most important process in the Water&Sewage water treatment. To choose proper mixer required much career and knowledge, to check many elements which are purpose, time and condition of mixing. Thus, the design method of mixers is to be utilized for the structural design of the water & Sewage water treatment.

  • PDF

갈수기 정수장운영관리 사례 - 갈수기 pH저감제(황산)투입에 의한 정수처리효율 향상 (Improvement of Water Treatment Efficiency by pH Decreasing Agent (H2SO4) for Droughty Seasons)

  • 가길현;김윤용;이준호;안치화;한인섭;민병대
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.415-422
    • /
    • 2008
  • Drinking water treatment is enhanced by coagulant dosages and chlorine injection because of pH increase in raw water in droughty seasons such as spring and fall. But water quality deterioration is occurred by increase in residual aluminium and disinfection by-products. Coagulation process can be used to control natural organic matter (NOM) during water treatment. The effect of coagulation process appeared to depend on the pH of water rather than coagulant dosages. In this study, for water treatment in high pH season $H_2SO_4$ was applied for pH adjustment at full scale. Before and after pH adjustment by $H_2SO_4$ injection, water quality of drinking water was evaluate. In the result of investigation of total organic carbon (TOC) removal in high pH season, TOC was removed approximately 30~40%, which showed decrease in water treatment efficiency. Also, it is increased both particle numbers and residual Al concentration in the water. After $H_2SO_4$ injection for adjustment to pH<7.5 in settled water, treated water turbidity decreased in 0.047 NTU from 0.059 NTU, and particle numbers of filtered water decreased in 20/mL from 90/mL. On the other side, TOC removal efficiency increased in approximately 10% after adjustment of pH. In the result of decrease in pH in raw water through more coagulants and prechlorine without $H_2SO_4$ injection, trihalomethanes (THMs) concentration increased in $16{\mu}g/L$ from $8{\mu}g/L$.

하천수 및 상하수도처리공정에서의 니트로사민류 조사 (Investigating of Nitrosamines in Small tributary rivers, Sewage Tretment Plants and Drinking Water Treatment Plants)

  • 김경아;노재순;빈재훈;김창원
    • 한국물환경학회지
    • /
    • 제26권3호
    • /
    • pp.446-453
    • /
    • 2010
  • This study was investigated nine nitrosamines in small tributary rivers, sewage treatment plants (STPs) and drinking water treatment plants. They are N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosopyrrolidine (NPYR), N-nitrosodi-n-propylamine (NDPA), N-nitrosomorpholine (NMOR), N-nitrosopiperidine (NPIP), N-nitrosodi-n-butylamine (NDBA) and N-nitrosodiphenylamine (NDPHA). The nine nitrosamines were analyzed by gas chromatography mass spectrometry (GC/MS) using solid phase extraction (SPE) with a coconut charcoal cartridge. Among the nine nitrosamines, NDMA, NMEA, NDEA, NDPA NDBA and NDPHA were detected in small tributary rivers and sewage tretment plants. In small tributary rivers, NDMA, NMEA, NDEA, NDPA, NDBA and NDPHA were obtained as ND~16.4 ng/L, ND~17.7 ng/L, ND~102.4 ng/L, ND~455.4 ng/L, ND~330.1 ng/L and ND~161.0 ng/L, respectively. Also NDMA, NMEA, NDEA, NDPA and NDBA were investigated ND~821.4 ng/L, 22.5~55.4 ng/L, 53.2~588.5 ng/L, ND~56.6 ng/L and ND~527.9 ng/L in STPs, respectively. In drinking water treatment plants, NMEA and NDEA concentration were increased to as high as 38.8 ng/L after ozonation process. However nitrosamines were decreased subsequent biological activated carbon (BAC) treatment process. It was supposed that nitrosamines were formed by $O_3$ oxidation and were removed by biodegradation of BAC.

A study on membrane technology for surface water treatment: Synthesis, characterization and performance test

  • Haan, Teow Yeit;Shah, Mubassir;Chun, Ho Kah;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.69-77
    • /
    • 2018
  • The use of membrane as an innovative technology for water treatment process has now widely been accepted and adopted to replace the conventional water treatment process in increasing fresh water production for various domestic and industrial purposes. In this study, ultrafiltration (UF) membranes with different formulation were fabricated via phase inversion method. The membranes were fabricated by varying the polymer concentration (16 wt%, 18 wt%, 20 wt%, and 21 wt%). A series of tests, such as field emission scanning electron microscope (FESEM), pore size and porosity, contact angle, and zeta potential were performed to characterize the membranes. The membrane performance in terms of permeation flux and rejection were evaluated using a laboratory bench-scale test unit with mine water, lake water and tube well as model feed solution. Long hour filtration study of the membranes provides the information on its fouling property. Few pore blocking mechanism models were proposed to examine the behaviour of flux reduction and to estimate the fouling parameters based on different degree of fouling. 21 wt% PVDF membrane with smaller membrane pore size showed an excellent performance for surface water treatment in which the treated water complied with NWQS class II standard.

새만금 담수 활용을 위한 요구수질별 최적의 수처리 방안 연구 (Design of Optimal Water Treatment Processes based on Required Water Quality for Utilization of the Saemanguem Lake Water)

  • 최경숙;이광야
    • 농업생명과학연구
    • /
    • 제46권2호
    • /
    • pp.169-178
    • /
    • 2012
  • 새만금 지역의 담수수자원의 활용과 고부가가치 창출을 위해 새만금 담수호를 활용한 요구수질별 용수공급을 위한 최적의 수처리 시스템을 선정하고 이에 대한 비용분석을 통해 요구수질별 담수수자원의 활용방안을 제시하고자 하였다. 다양한 수처리 기법들의 종류, 주요 특성 및 오염인자 제거효율, 공법의 장단점 등의 비교분석을 통해 수질오염인자별 유리한 처리공법을 제시하였으며, 최적의 수처리시스템을 도출하여 새만금 지역 내 요구수질별 수처리 비용을 분석하였다. 연구결과를 통해 SS(Suspended Solid), BOD(Biochemical Oxygen Demand), 탁도 제거를 위해 FDA(Filter Disinfection Adsorption)여과기, 대장균 제거를 위한 UV(Ultra-Violet)처리공정, T-P(Total Phosphorus), T-N(Total Nitrogen) 제거를 위한 FNR(Ferrous Nutrient Removal)공법, 그리고 저농도 염처리 공정을 위해 전기투석법이 유리한 공법으로 조사되어 최적의 수처리시스템의 요소기술로 각각 선정되었다. 각 요구수질별 선정된 수처리공정에 따른 비용분석과 적용사례를 제시하여 새만금지역 담수 활용도를 높이고 부족한 상수원 해결의 대안으로 적용할 수 있을 것으로 사료된다.