• 제목/요약/키워드: Water temperature

검색결과 14,590건 처리시간 0.046초

취나물류의 물질생산과 광합성특성에 관한 연구 II. 수분스트레스하에서 고온 및 저온처리가 취나물류의 광합성속도에 미치는 영향 (Study on Matter Production and Phothsynthetic Characteristics in Wild Vegetable(Chwinamul))

  • 조동하
    • 한국자원식물학회지
    • /
    • 제11권3호
    • /
    • pp.307-314
    • /
    • 1998
  • The response of water stree under high and low temperatures, was shown differently according to the longer the suspension period of water supply. Leaf photosynthetic rate(LPS), leaf water potential(WP), relative leaf water content and relative soil water content were lower. At the higher temperatures, the percentate of reduction in LPS and WP was greater than at low temperatures. It is suggested that evaporation rate should be higher in the high temperature than the lower temperature. Also leaf water potential was lower at high temperature than at low temperature. After the 9 th day of treatment , LSP was remarkably reduced at high temperature, but the reduction of LPS was not significant at low temperature. Solidago virga-aurea var. asiatic that maintained LPS of 3rd day after treatment was more strong than other varieties at low temperatures. The silting and curling of leaves were observed symptoms of stress on the 9th day at the both temperatures. The leaves of aster scaber and Ligularia fischeri turned red on the 9th day after treatment at low temperature.

  • PDF

조간대에서 조위에 따른 기온과 수온 변화 : 여수 오도섬 (Variations in Air Temperature and Water Temperature with Tide at the Intertidal Zone : Odo Island, Yeosu)

  • 조원기;강동환;김병우
    • 한국환경과학회지
    • /
    • 제31권12호
    • /
    • pp.1027-1038
    • /
    • 2022
  • The intertidal zone has both land and marine characteristics and shows complex weather environments. These characteristics are suited for studying climate change, energy balance and ecosystems, and may play an important role in coastal and marine weather prediction and analysis. This study was conducted at Odo Island, approximately 300m from the mainland in Yeosu. We built a weather observation system capable of real-time monitoring on the mud flat in the intertidal zone and measured actual weather and marine data. Weather observation was conducted from April to June 2022. The results showed changes in air temperature and water temperature with changes in the tide level during spring. Correlation analysis revealed characteristic changes in air temperature and water temperature during the day and night, and with inundation and exposure.

MBR 공정에서 수온에 따른 막오염 및 CEB 세정효율 특성 (Characterization of membrane fouling and CEB (Chemical enhanced backwashing) efficiency with temperature in SMBR Process)

  • 박기태;박정훈;최은혜;김형수;김지훈
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.389-395
    • /
    • 2017
  • In this paper, we investigate the characteristics of membrane fouling caused by water temperature in the Membrane bioreactor(MBR) process and try to derive the membrane fouling control by chemical enhanced backwashing(CEB). The extracellular polymeric substances(EPS) concentration was analyzed according to the water temperature in the MBR, and the membrane fouling characteristics were investigated according to the conditions, with sludge & without sludge, through a lab-scale reactor. As shown in the existing literature the fouling resistance rate was increased within sludge with the water temperature was lowered. However, in the lab-scale test using the synthetic wastewater, the fouling resistance increased with the water temperature. This is because that the protein of the EPS was more easily adsorbed on the membrane surface due to the increase of entropy due to the structural rearrangement of the protein inside the protein as the water temperature increases. In order to control membrane fouling, we tried to derive the cleaning characteristics of CEB by using sodium hypochlorite(NaOCl). We selected the condition with the chemicals and the retention time, and the higher the water temperature and the chemical concentration are the higher the efficiencies. It is considered that the increasing temperature accelerated the chemical reaction such as protein peptide binding and hydrolysis, so that the attached proteinaceous structure was dissolved and the frequency of the reaction collision with the protein with the chemical agent becomes higher. These results suggest that the MBRs operation focus on the fouling control of cake layer on membrane surface in low temperatures. On the other hand, the higher the water temperature is the more the operation strategies of fouling control by soluble EPS adsorption are needed.

벼의 냉수피해 감소를 위한 관개수온 조사와 대책수립 (Measurement of Irrigation Water Temperature and Preventive Measure against Cold Watter Damage to Paddy Rice)

  • 정상옥
    • 한국농공학회지
    • /
    • 제41권1호
    • /
    • pp.52-59
    • /
    • 1999
  • Paddy rice is semi-tropical crop and requires warmirrigation water. If mean water temperature at the water source during the growing period is below 18$^{\circ}C$, sime kinds of water warming mechanism should be taken. In this study irrigation water temperature is measured and preventive measures to cold water damage on paddy rice are suggested. Field observations were performed at 100ha field area downtream of the Unmoon reservoir during the growing season of 1997. Land use, canal system, water temperature at irrigation canals. reservoir, and paddy fields were observed. In addition, growth and yield of the rice at selected plots were observed. Accordingly to the record, cold water damage occurred in this area due to the cold irrigation water supply in 1996. It did not occur because of the effective irrigation water management practice in 1997. However, several preventive measures such as pontoon intake system, using existing weir and construting a new warming pond, are suggested to prevent cold water damage in the future. If a new warming pond is construted to raise irrigation water temperature by 2 $^{\circ}C$, a pond area of 2.94 ha is required.

  • PDF

Effect of cooling water temperature on the temperature changes in pulp chamber and at handpiece head during high-speed tooth preparation

  • Farah, Ra'fat I.
    • Restorative Dentistry and Endodontics
    • /
    • 제44권1호
    • /
    • pp.3.1-3.10
    • /
    • 2019
  • Objectives: It was the aim of this study to evaluate the effect of cooling water temperature on the temperature changes in the pulp chamber and at the handpiece head during high-speed tooth preparation using an electric handpiece. Materials and Methods: Twenty-eight intact human molars received a standardized occlusal preparation for 60 seconds using a diamond bur in an electric handpiece, and one of four treatments were applied that varied in the temperature of cooling water applied (control, with no cooling water, $10^{\circ}C$, $23^{\circ}C$, and $35^{\circ}C$). The temperature changes in the pulp chamber and at the handpiece head were recorded using K-type thermocouples connected to a digital thermometer. Results: The average temperature changes within the pulp chamber and at the handpiece head during preparation increased substantially when no cooling water was applied ($6.8^{\circ}C$ and $11.0^{\circ}C$, respectively), but decreased significantly when cooling water was added. The most substantial drop in temperature occurred with $10^{\circ}C$ water ($-16.3^{\circ}C$ and $-10.2^{\circ}C$), but reductions were also seen at $23^{\circ}C$ ($-8.6^{\circ}C$ and $-4.9^{\circ}C$). With $35^{\circ}C$ cooling water, temperatures increased slightly, but still remained lower than the no cooling water group ($1.6^{\circ}C$ and $6.7^{\circ}C$). Conclusions: The temperature changes in the pulp chamber and at the handpiece head were above harmful thresholds when tooth preparation was performed without cooling water. However, cooling water of all temperatures prevented harmful critical temperature changes even though water at $35^{\circ}C$ raised temperatures slightly above baseline.

열원 및 부하조건에 따른 물-공기 히트펌프 시스템의 성능분석 (Performance Analysis of Water-to-Air Heat Pump System under Water Temperature and Load Ratio)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.194.2-194.2
    • /
    • 2011
  • Heating and cooling performance has been analyzed for the water-source heat pump system using raw water from Daechung reservoir. During heating operation from March to May, water temperature is not good condition for a heat source due to the higher atmospheric temperature. Avearged heating load ratio is only 14.3%, and the averaged unit COP and system COP are estimated to be 2.46 and 2.15 respectively. The COP is affected considerably by the water temperature, and the unit COP is increased from 2.16 at $5^{\circ}C$ to 2.95 at $11^{\circ}C$. Cooling performance is analyzed with the measured data from June to August. During cooling operation, raw water has lower temperature by 4. $5^{\circ}C{\sim}4.7^{\circ}C$ than the atmosphere. The load ratio is 39.2%, and the averaged unit COP and system COP are estimated to be 7.25 and 6.13 respectively. The heating COP is affected by the load ratio rather than water temperature. The COP is increased for 20%~40% load ratio, while is decreased for 40%~60% load ratio. It is estimated that the compressor operation combination for 3 (two constant speed and one inverter) compressors is changed for the load ratio.

  • PDF

스펙트럼 분석을 통한 2016년 하계 한국연안의 수온변동 특성에 관한 연구 (A Study on the Characteristics of Summer Water Temperature Fluctuations by Spectral Analysis in Coast of Korea in 2016)

  • 서호산;정용현;김동선
    • 해양환경안전학회지
    • /
    • 제26권2호
    • /
    • pp.186-194
    • /
    • 2020
  • 본 연구에서는 한국의 동해, 서해 및 남해안에서 하계 수온의 단기적인 변화에 영향을 주는 환경 요인을 파악하기 위해 국립해양조사원에서 제공하는 2016년 하계 조위관측소의 수온, 기온, 조위 및 바람자료를 이용하여 스펙트럼 분석을 실시하였다. Power spectrum 분석 결과, 평균조차가 100 cm 이상인 서해안(인천, 평택, 군산 및 목포)과 남해안(완도, 고흥, 여수, 통영 및 마산)에서는 수온, 조위가 동일한 주기에서 peak가 나타났다. 반면에 서해안과 남해안에 비해 평균조차가 상대적으로 작은 동해안(묵호, 포항 및 울산)과 부산에서는 수온의 주기성이 나타나지 않았다. Coherence 분석에서 서해안과 남해안의 3개 정점(완도, 고흥, 통영)은 수온과 조위의 상관성이 높게 나타났다. 특히 완도와 통영에서 수온과 조위의 상관성은 반일주기에서 0.96으로 높았다. 여수는 조석과 담수의 유입이 수온에 영향을 주는 것으로 보인다. 한편 마산의 수온은 남풍의 바람 영향이 가장 크지만 조석과 담수의 영향도 받는 것으로 판단된다. 그리고 동해안은 조차가 작고 해류의 영향이 크기 때문에 수온에 대한 조석의 영향이 작은 것으로 사료된다. 환경 요인의 시계열그래프를 비교한 결과, 수온과 조위가 상관성이 높게 나타난 정점은 창조 시 비교적 저수온의 외해수가 유입되고 낙조 시 빠져나가는 것으로 판단된다. 일주기의 수온 변화는 조석의 영향이 크지만 전체적인 수온의 상승과 하강은 기온의 영향이 큰 것으로 보인다.

프로세스 시뮬레이션에 의한 제 2종 흡수식 열펌프 성능에 관한 연구 (A Study on the Performance of an Absorption Heat Transformer with Process Simulation)

  • 조승연;김영인
    • 대한설비공학회지:설비저널
    • /
    • 제16권3호
    • /
    • pp.295-304
    • /
    • 1987
  • The purpose of this study is to develop a computer model for simulating the water-lit hium bromide absorption heat transformer (AHT) Including all major components and to find the flexibility in operation. The effect of source hot water temperature, cooling water temperature, useful hot water flow rate, cooling water flow rate and evaporator circulation flow rate were investigated. The coefficient of performance (COP), temperature boost $({\Delta}T\;=\;T_A\;-\;Ti)$ and concentration variations can be predicted. The performance study indicates that the performance of AHT increases for the waste hot water temperature increasing and with a decrease of the cooling water temperature. The effect on performances of useful hot water flow rape is significant except on temperature boost. Also the effects on performance of cooling water flow rate and evaporator circulation flow rate are small. It is shown that the computer program is valuable to predict the performance of absorp-tion heat transformer units at various working corditions.

  • PDF

증발억제법에 의한 수온 및 지온상승효과에 관한 연구

  • 김광식
    • 물과 미래
    • /
    • 제5권2호
    • /
    • pp.6-16
    • /
    • 1972
  • It has been well studied and known that the yields from the rice fields irrigated by the cold water such as the water directly flowing in from mountain valleies, underground water and subground water are largely influenced by the water temperature. However, the best method of raising water temperature has not yet been established. This is because there are some essentially difficult problems associated. When we examine the effects of $1^{\circ}C$ rise in the water temperature under natural condition on rice growing, the necessity of this line of study is verified. The results of Mihara's study show that rice bears its fruits at the water temperature above $19^{\circ}C$ and the difference of $1^{\circ}C$ in the range of $19^{\circ}C$ to $22^{\circ}C$ can produce the 20% of difference in yields. Because of these facts, most farmers have made use of water temperature raising ponds, zigzag waterways and shelter belts. But the most important factor in raising water temperature has been found to be the heat loss due to evaporation. Recently, a good deal of experiment on raising water temperature and soil temperature by reducing the evaporation are being carried out all over the world. The reduction of evaporation does not only reduce heat loss, from the surface but also reduce the loss of water. Present study is aimed to determine the efficiency of different chemicals by which monomolecular films are formed over different surfaces such as water surface, soil surface and the surface of plant leaves with a purpose of preventing the transpiration, and aimed to observe the effects of the temperature rise and its influence on growing state as well as the durability of the plants under drought condition.

  • PDF

댐의 심층저온수 취수시 수온 성층화 유지 조건에 대한 CFD를 이용한 분석 (Analysis of the Water Temperature Stratification-Maintaining Conditions Using CFD in Case of Intake of Deep, Low-Temperature Water)

  • 이진성;조수;심경종;장문성;손장열
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.31-38
    • /
    • 2009
  • This study was conducted to forecast inner water temperature strata change by extracting deep water from a dam. For the methodology, the scope wherein the balance between the volume of low-temperature water intake through the virtual water intake opening as installed within the stored water area and the volume of water intake from the surrounding area is not destroyed was calculated through the CFD simulation technique using the computational fluid dynamics(CFD) interpretation method. This study suggested a supplementary method(diffuser) to avoid destroying the water temperature strata, and the effect was reviewed. In case of intake of the same volume, when the velocity of flow of water intake is reduced by increasing the pipe diameter, the destruction of water temperature strata can be minimized. When the area(height) where the intake of water is possible is low, a diffuser for interrupting the vertical direction inflow should be installed to secure favorable water intake conditions in case of water intake on the upper part. This study showed that there was no problem if the intake-enabled, low-temperature area was secured approximately 10m from the bottom when the scope that does not destroy the water temperature strata in case of water intake was forecast using the regression formula.