• 제목/요약/키워드: Water switching

검색결과 114건 처리시간 0.025초

Determination of Pesticide Residues in Water using On-line SPE-HPLC Coupling System

  • Lee, Dai Woon;Lee, Sung Kwang;Park, Young Hun;Paeng, Ki-Jung
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.539-543
    • /
    • 1995
  • The on-line SPE-HPLC coupling system was developed for the efficient separation and determination of trace pesticides, such as phenoxyacetic acids and esters, and triazines in aqueous solutions. By using the developed SPE-HPLC on-line system, the band broadening usually observed in single precolumn switching mode was greatly reduced, consequently, the quantitative determination of trace pesticides could be achieved, Besides, since most of the analytes preconcentrated by SPE column could be injected directly into HPLC system, the limit of detection can be improved down to ppt level.

  • PDF

수중 음향 채널에서 적응형 OFDM의 성능 분석 (Performance analysis of an adaptive OFDM over an underwater acoustic channel)

  • 임요웅;강희훈
    • 한국전자통신학회논문지
    • /
    • 제5권5호
    • /
    • pp.509-515
    • /
    • 2010
  • 최근 심해 해난 구조 통신, 해저 탐사와 환경오염에 대한 모니터링과 같은 서비스에서 수중 음향 채널을 통한 데이터의 전송은 고속이 요구되고 있다. 수중 음향 채널은 매우 복잡하고 지속적인 시변 특성을 가지므로 기존의 무선 통신 기술들은 좋은 성능을 나타내지 못한다. 이러한 수중 음향 채널에서 고속 전송을 제공하고 열악한 환경에 대해서 신뢰성이 있고 강건한 통신 서비스를 제공하기 위해서 본 논문에서는 적응형 OFDM 시스템의 성능을 분석한다. 이를 통해서, 음성 통신 서비스를 기준으로 수중 음향 채널에서 적절한 적응 알고리즘의 적응 스위칭을 위한 임계값을 제시한다.

Mycoplasma pneumoniae의 성장과 형태에 미치는 환경요소적 영향 (Effects of environmental factors on growth and morphology of mycoplasma pneumoniae)

  • Kim, Chi-Kyung
    • 미생물학회지
    • /
    • 제16권3호
    • /
    • pp.131-139
    • /
    • 1978
  • Mycoplasma pneumoniae was examined for growth characteristics and morphology when cultivated in several media supplemented with a variety of sera and under different atmospheric conditions. different formula of the medium as well as different sources of lot numbers of the serum in the same medium exhibited varying effects on growth rate and adherence. When the organisms were cultivated in SSR-2 medium in a normal atmospheric environment or under a facultative anaerobic condition provided with carbon dioxide, they developed filamentous cells with heavy growth, whereas mainly round-shaped cells were produced under strict anaerobic conditions of hydrogen and carbon dioxide. Both morphologies of the organism were transformed by switching the incubation environments. An inverted phasecontrast microscopy using modified petri dishes was excellent to observe single cells and useful to follow the development of the cells. Growth, turbidity, and pneumoniae colonies developed on a solid medium and produced clear when overlaid with sheep blood agar.

  • PDF

견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가 (Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis)

  • 왕종배;김명룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF

수분함유량에 따른 토양의 저항률 및 비유전율의 주파수의존성 (Frequency-Dependent Resistivity and Relative Dielectric Constant of Soil on Water Content)

  • 최종혁;차응석;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.98-104
    • /
    • 2010
  • 고주파수성분을 포함하는 뇌격전류나 또는 고장전류에 대한 접지시스템의 성능을 평가하기 위해 접지저항보다는 접지임피던스에 대한 고려가 필요하다. 접지임피던스를 평가하기 위해서는 토양의 저항률과 비유전율의 주파수의존성이 규명되어야 한다. 본 논문은 3가지 다른 토양에 대하여 수분함유량에 따른 저항률과 비유전율의 주파수의존성을 나타낸다. 결론적으로 토양의 저항률은 수분함유량이 증가함에 따라서 작아지게 되고, 1[MHz]보다 낮은 주파수에서 거의 변화하지 않으며 1[MHz]이상의 주파수에서는 감소한다. 반면에 비유전율은 1[MHz]이하의 주파수에서 매우 급격하게 감소하며, 1[MHz]이상의 주파수에서는 거의 변화하지 않는 것으로 나타났다. 본 실험 결과로 부터 낙뢰 또는 개폐서지에 대한 보호를 목적으로하는 접지시스템의 설계시 토양의 저항률과 비유전율을 고려하는 것이 바람직한 것으로 밝혀졌다.

단위 인버터 병렬운전에 의한 발전소 해수펌크 적용 (Studies on the Application of Unit-inverter Parallel Operation to Sea-water Lift Pump in Power Plant)

  • 김수열;류홍우
    • 전력전자학회논문지
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 1998
  • 발전설비의 대형화로 인하여 전력절감 문제가 크게 대두되었고, 팬이나 펌프를 부하 변화에 따라 속도제어하므로써 전기 에너지를 절약 할 수 있다. 1MVA급 단위 인버터 2대를 병렬 운전하여 대용량 2MVA GTO 인버터를 구현하였으며, 단위 인버터의 병렬 운전은 2대의 출력변압기 2차측 결선을 직렬 연결하여 구현하였다. 개발된 시스템은 제어반, 정류기반, 2대의 인버터반으로 구성되어 있으며, 이 시스템은 한국전력공사 성인천복합화력발전처 해수펌프 구동 유도전동기(6.6KV 1500KW)에 적용되어 전력절감에 기여하고 있다. 또 단위 인버터가 상호 180$^{\circ}$위상차를 갖도록 병렬 운전하므로써 고조파 성분을 저감시키면서 대용량을 구현하였다.

소유역에서 홍수조절용 펌프 및 유수지 규모의 결정에 관한 연구 (A Study on Determination of Capacity for Pump and Detention Pond in Small Basins for Flood Control)

  • 안태진;박종윤;류희정;김중훈
    • 한국수자원학회논문집
    • /
    • 제36권3호
    • /
    • pp.385-398
    • /
    • 2003
  • 내배수시설계획시 최대저류비에 의한 유수지 규모의 결정 방법은 이전 연구자에 의하여 제시된 바 있다. 본 연구에서는 동두천시 11개 소규모 내배수시설을 선정하여 분석한 결과, 배수면적이 작고 펌프기능이 강화된 내배수 시설에서는 강우지속기간별 우수지의 저류비의 차이는 미미하므로 최대저류비에 의한 조정지 규모의 결정은 무리가 있음을 알 수 있었다. 또한 최대저류비에 의하여 결정된 조정지 용량을 펌프에 의하여 배제되는 시간은 펌프의 허용시동간격보다 짧은 경우도 있어 펌프의 빈번한 작동을 초래한다. 그러므로 조정지는 펌프의 빈번한 작동에 의한 펌프 고장의 가능성을 피할 수 있는 규모로 결정되어야 한다. 다양한 펌프용량을 적용하여 분석한 결과, 소유역에서도 조정지의 기능이 강화된 내수배제시설에서는 최대저류비를 기준으로 한 조정지 용량의 결정은 펌프운영 측면에서 타당함을 알 수 있었다. 따라서 본 연구에서는 소규모 배수구역에서 조정지용량의 결정시 펌프의 계획배수량과 유수지의 용량에 따른 펌프의 시동빈도를 반영하여 기존의 최대저류비에 의한 방법을 개선한 방안을 제시하였다. 또한 유수지 규모와 펌프용량의 관계를 간단한 선형계획모형으로 분석한 결과, 종래의 유수지 홍수추적에 의한 유수지 용량 결정은 도시지역의 내배수시설 계획에만 타당함을 알 수 있었다.

Directions towards sustainable agricultural systems in Korea

  • Kim, Chang-Gil
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.3-3
    • /
    • 2017
  • The question of how to establish sustainable agricultural systems has become as prominent as questions related to water, energy and climate change. High input/high output agriculture has brought with it many adverse effects; the massive deterioration of soil and water in both quantity and quality, increased greenhouse gas emissions and an increased prevalence of unsafe foods. Additionally, urbanization and climate change has worsened the shortage of farmland and reduced the supply of agricultural water. Given these challenges, maintaining, conserving and efficiently using agri-environmental resources, through fostering of sustainable agriculture, have emerged as key tasks in solving these problems. What is needed therefore is research, based on systematic and comprehensive empirical analyses, that can propose plans and methods for establishing an appropriate sustainable agricultural system. The empirical analysis of sustainable agricultural system is approached separately from economic, environmental and social aspects. An analysis of environment effect reveals that the available phosphate level is 1.3~2.1 times greater than the optimal amount in rice paddies, upland fields and orchards. Further examination has revealed that the excess nutrient is polluting both ground water and surface water. Analytical results for economic feasibility show that factors of production have been invested heavily in the rice crop. Under these conditions, sustainable agriculture, including low-input agriculture, appears to be a possible alternative that will facilitate simultaneous improvements in both economic feasibility and environment effects. Analysis results for sociality reveal that social factors include the value of producer, association and interior networks. Social conditions are comprised of leadership, consumers' awareness, education and conflict solutions. In addition, analysis as to the degree investments contribute to improving agricultural value added has revealed that the direct payment program is the most effective instrument. Experts confirm that economic feasibility can be improved by scientific and well-reasoned nutrient management on the basis of soil testing. Farmers pointed to 'economic factors' as being the largest obstacle to switching to the practice of sustainable agriculture. They also indicate 'uncertainty with regards to sustainable agriculture technology' as an impediment to practicing sustainable agriculture. Even so, farmers who believe environmental and regional issues to be the most pressing problems have expanded their practice of sustainable agriculture. The keys to establishing sustainable agriculture system are classified into the following four aspects. Firstly, from an economic aspect, the research indicates that agricultural policy needs to be integrated with environmental policy and that the function of market making based on the value chain needs to be revitalized. Secondly, from an environmental aspect, there is a need for an optimal resource management system to be established in the agricultural sector. In addition, sustainable agriculture practice will need to be extended with attendant environmentally-friendly and sustainable intensive technology also requiring further development. Thirdly, from a social aspect, green agriculture management needs to be fostered, technology and education extended, and social conflict mediated. Lastly, from a governance aspect, it will be necessary to strengthen good governance, assign and share suitable roles and responsibilities, build a cooperation system and utilize community supported agriculture.

  • PDF

저출력 및 과도상태시 원전 증기발생기 수위제어에 관한 연구 (A Study on Water Level Control of PWR Steam Generator at Low Power Operation and Transient States)

  • 나난주;권기춘;변증남
    • 한국지능시스템학회논문지
    • /
    • 제3권2호
    • /
    • pp.18-35
    • /
    • 1993
  • 가압경수로형 원자력발전소 수위제어시스템과 특히 저출력시 수위제어상의 문제점들이 분석 및 고찰되었으며 저출력으로 운전시의 여러 과도특성에서도 안정된 제어를 하고 급수펌프고장과 같은 큰 수위변동 발생시에는 신속한 수위응답을 얻기 위한 방법이 주로 연구되었다. 제어기의 기본 알고리즘으로 퍼지제어기법을 적용하였으며 여기에 필요한 제어규칙 및 알고리즘은 운전원의 지식과 한국원자력연구소에 설치된 교육훈련용 모의제어반에서의 수동운전경험을 바탕으로 설정되었다. 실제 시스템 구현관점에서 제어변수 및 적용규칙은 보다 간편한 튜닝과 입출력변수간의 영향을 고려하여 세워졌다. 저유량일 때 측정이 불량한 유량신호에 대해, 중기발생기를 압력제어모드로 운전할 때에는 유량차의 퍼지변수로서 우회급수밸브의 개도를 이용한 대체정보를 채용하였으며 수위오차의 크기에 따라 유량차의 소속함수를 달리하는 동적인 튜닝방법을 사용하였다. 또한 우회급수와 주급수밸브간 간단한 전환알고리즘의 적용으로 밸브절환시의 수위요동을 억제하고자 하였다. 시뮬레이션 결과 저출력구간에서 원자로출력변동에 대해 기존에 설치된 방법보다 안정된 제어를 하고 동적 튜닝의 적용으로 미세제어동작과 수위오차가 큰 영역의 제어에 대해 신속한 응답과 함께 제어성능이 개선되었음을 보였다.

  • PDF

시화호의 중금속 오염과 산화-환원 상태의 공간적 차이 (Heavy Metal Contamination and Spatial Differences in Redox Condition of the Artificial Shihwa lake, Korea)

  • 현상민;김은수;팽우현
    • 한국환경과학회지
    • /
    • 제13권5호
    • /
    • pp.479-488
    • /
    • 2004
  • Five sediment cores from the tidal flat of artificial Lake Shihwa are analyzed in terms of sedimentology and geochemistry to evaluate the heavy metal contamination and redox condition of surficial sediment following the Shihwa seawall construction. The variability of concentrations of various elements depends on the depositional environment, and reflects the various redox conditions and sediment provenances. The amounts of Ti and Al and their ratio of Ti/ Al with respect to Li clearly indicate that there is an anthropogenic contribution to the surficial sediment. The high concentrations of heavy metals suggest an anthropogenic contribution at ST. 34 and ST. 22. Concentrations of most elements (Cr, Cu, Zn and Pb) are higher near the Shihwa-Banwol industrial complex than in the central part of Lake Shihwa. Concentrations of heavy metal in surficial sediment near the Shihwa-Banwol industrial complex are two to eight times higher than in the center of Lake Shihwa. Enrichment factors (EF), which are normalized by the unpolluted shale, suggests a significant metallic contamination near the Shihwa-Banwol industrial complex (SBIC). The redox condition is divided into two anoxic and mixed oxi $c_oxic zones based on the carbon:sulfur (C/S) ratios of organic matter and elemental relationships. Correlations among geochemical elements Mn, U and Mo are significantly different from site to site, and may therefore be an indicator of the spatial redox condition. Controlling factors for switching anoxic/oxic conditions are thought to be water depth and the differences in industrial effluent supply. The variations of the Cu/Mn ratio in the sediments confirms above mentioned spatial differences of a redox condition in part, and therefore shows a location-dependence redox condition in sediments at four other sites. The redox condition of the surficial sediment characteristics of the Shihwa Lake are controlled by its geographic location and water depth.th.