• Title/Summary/Keyword: Water supply & sewage system

Search Result 61, Processing Time 0.028 seconds

Pulsed Power System for Leachate Treatment Application (침출수 처리 응용 펄스전원 시스템)

  • Jang, S.R.;Ahn, S.H.;Ryoo, H.J.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.246-247
    • /
    • 2010
  • This paper deals with the water treatment of the leachate from sewage filled ground by a pulsed power technology. Leachate from sewage filled ground should be treated below regulation level of COD in order to prevent environmental pollution and usually treated by a chemical method. Among the pollutants mixed in the leachate, chemical compounds of benzene series are known to be difficult to break down, and need to use high cost treat methods. The treatment of the benzene compounds by high power pulsed power supply was studied. For the high-rate, cost-effective treatment of leachate, pulsed power supply should have high repetition rates and require switching devices of long lifetime. In order to meet the demands of the above condition, pulsed power generator based on semiconductor switches using IGBTs as primary switches were developed. The experimental results verified that benzene compounds can be treated effectively by high voltage electric pulses, and this fact indicates that the treatment method by pulsed power source is a promising substitute.

  • PDF

A Study on Securing Instream Flow for Restoring Ecosystems and Riverine Aesthetics of a Degraded Urban Stream - Applied to the Mugeo Stream in the Ulsan Metropolitan Area - (하천생태계와 경관복원을 위한 도시소하천의 유지유량확보에 관한 연구 - 울산 무거천을 중심으로 -)

  • Lee, Soo-Sik
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.649-655
    • /
    • 2007
  • This study was focused on estimating instream flow, and its optimal alternative for securing the required total amount of instream flow was also researched in order to restore ecosystems and riverine aesthetics of the Mugeo Stream. the first tributary of the Taewha River flowing through the center of Ulsan. In this study the hydraulic and hydrologic conditions and water quality were investigated at specific channel reaches and representative stations of the Mugeo Stream to determine a proper estimate of instream flow. And riverine functions, such as the minimum flow, water duality conservation, fish habitat, and recreation, were considered to restore the environmental functions of the stream, As a result, the total amount of $11,500m^3/day$ was set as the target instream flow for the Mugeo Stream. It was chosen as the optimal alternative for securing the total external supply of $10,000m^3/day$ which have to be transfered from the riverbed flow diverted through the Taewha Main river at upstream of Samho bridge. The water duality throughout the Mugeo Stream channels will be improved considerably to 3-4 mg/l of BOD standard if the target instream flow is supplied and sewage is intercepted by the sanitary sewage system.

Problems of lake water management in Korea (한국의 호수 수질관리의 문제점)

  • 김범철;전만식;김윤희
    • Proceedings of the Korean Society of Environment and Ecology Conference
    • /
    • 2003.10a
    • /
    • pp.105-126
    • /
    • 2003
  • In Korea most of annual rainfall is concentrated in several episodic heavy rains during the season of summer monsoon and typhoon. Because of uneven rainfall distribution many dams have been constructed in order to secure water supply in dry seasons. The Han River system has the most dams among Korean rivers, and the river is a series of dams now. Reservoirs need different strategy of water quality control from river water. Autochthonous organic matter and phosphorus should be the major target to be controlled in lakes. In this Paper some problems are discussed that makes efforts of water quality improvement ineffective in lakes of Korea, even after the substantial investment to wastewater treatment facilities.1) Phosphorus is the key factor controlling eutrophication of lakes and the reduction ofphosphors should be the major target of water treatment. However, water quality management strategy in Korea is still stream-oriented, and focused on BOD removal from sewage. Phosphorus removal efficiency remains as low as 10-30%, because biological treatment is adopted for both secondary treatment and advanced treatment. The standard for TP concentration of the sewage treatment plant effluent is 6 mgP/l in most of regions, and 2 mg/l in enforced region near metropolitan water intake point. TP in the effluents of sewage treatment plants are usually 1-2 mg/1, and most of plants meet the effluent regulation without a further phosphorus removal process. The generous TP standard for effluents discourages further efforts to improve phosphorus removal efficiency of sewage treatment. Considering that TP standard for the effluent is below 0.1 mg/l in some countries, it should be amended to below 0.1 mg/l in Korea, especially in the watershed of large lakes.2) Urban runoff and combined sewer overflow are not treated, even though their total loading into lakes can be comparable to municipal sewage discharges on dry days. Chemical coagulation and rapid settling might be the solution to urban runoff in regard of intermittent operation on only rainy days.3) Aggregated precipitation in Korea that is concentrated on several episodic heavyrains per year causes a large amount of nonpoint source pollution loading into lakes. It makes the treatment of nonpoint source discharge by methods of other countries of even rain pattern, such as retention pond or artificial wetland, impractical in Korea.4) The application rate of fertilizers in Korea is ten times as high as the average ofOECD countries. The total manure discharge from animal farming is thought to be over the capacity of soil treatment in Korea. Even though large portion of manure is composted for organic fertilizer, a lot of nutrients and organic matter emanates from organic compost. The reduction of application rate and discharge rate of phosphorus from agricultural fields should be encouraged by incentives and regulations.5) There is a lot of vegetable fields with high slopes in the upstream region of the HanRiver. Soil erosion is severe due to high slopes, and fertilizer is discharged in the form of adsorbed phosphorus on clay surface. The reduction of soil erosion in the upland area should be the major preventive policy for eutrophication. Uplands of high slope must be recovered to forest, and eroded gullies should be reformed into grass-buffered natural streams which are wider and resistant to bank erosion.

  • PDF

The Propose of Optimal Flow Data Acquisition by Error Rate Analysis of Flow Data (유량 데이터 오차율 분석을 통한 최적의 유량데이터 취득방안 제안)

  • Kim, Yunha;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.249-256
    • /
    • 2017
  • Recently, application areas based on M2M (Machine-to-Machine communications) and IoT (Internet of Things) technologies are expanding rapidly. Accordingly, water flow and water quality management improvements are being pursued by applying this technology to water and sewage facilities. Especially, water management will collect and store accurate data based on various ICT technologies, and then will expand its service range to remote meter-reading service using smart metering system. For this, the error in flow rate data transmitting should be minimized to obtain credibility on related additional service system such as real time water flow rate analysis and billing. In this study, we have identified the structural problems in transmitting process and protocol to minimize errors in flow rate data transmission and its handling process which is essential to water supply pipeline management. The result confirmed that data acquisition via communication system is better than via analogue current values and pulse, and for communication method case, applying the industrial standard protocol is better for minimizing errors during data acquisition versus applying user assigned method.

Groundwater system Investigation of the Cheonggyecheon watershed Area

  • Choi, Doo-Hyung;Yang, Jae-Ha;Jun, Seong-Chun;Lee, Kang-Keun;Kim, Yoon-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.326-329
    • /
    • 2004
  • The groundwater system of the Cheonggyecheon watershed is very complicated because it is influenced by many factors such as pumping out, groundwater leakages into subway stations, civil use of groundwater, and leaking water from water supply and sewage lines. So the characterization and evaluation of the groundwater flow and contaminant transport in the Cheonggyecheon water system is quite a difficult task. The purpose of this study is to analyze the influence on the‘groundwater’ below the Cheonggyecheon watershed by the‘maintenance water’on the Cheonggyecheon stream after the restoration. We have so far collected groundwater quality data, hydrogeologic aquifer parameters, and the amount of leakages into subway stations and its influence on the groundwater system. Results show that groundwater level was influenced by the direction and depth of subway tunnel. This study will continue to monitor groundwater quality, a water level fluctuation relation between rainfall and groundwater recharge for further investigation of the groundwater flow system in the Cheonggyecheon watershed.

  • PDF

Analysis of RCSTP And MWTP Pollutants Treatment Efficiency in Bong-Hwa Gun (봉화군 마을하수도 및 하수처리장의 오염물질 처리 효율 분석)

  • Park, Minsoo;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.69-79
    • /
    • 2017
  • Protected area of water for supply source is located mostly of rural area in Korea. Normally, sewage treatment system is poor to manage in rural, because low population and density. Rural area need sewage treatment system to supervise supply source of water. In this study, analysis on operation result of 4 RCSTP and MWTP is located at the rural area. Higher concentration of pollutant were inflows to MWTP than RCSTP, and effluent quality standard is satisfaction. However, RCSTP effluent pollutant concentrations was researched higher than MWTP. The organic matter(BOD, COD) were about 5% of a high treatment efficiency to a median. The nutrient(T-N, T-P) were detected Up to high 30%. Also, we analyzed to effect reactor operational parameters on the pollutant treatment efficiency like mixed liquer suspended solid(MLSS), dissolved oxygen(DO) and sludge retention time(SRT). As a result, pollutant treatment efficiency showed fluctuation in accordance with operating condition. Thus, it is necessary to manage the reactor operation condition for management of rural area sewage treatment.

Groundwater Investigation of the Cheonggyecheon Watershed Area

  • Choi, Doo-Hyung;Yang, Jea-Ha;Jun, Sung-Chun;Lee, Kang-Keun;Kim, Yoon-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.323-327
    • /
    • 2004
  • The groundwater system of the Cheonggyecheon watershed is very complicated because it is influenced by many factors such as pumping out, groundwater leakages into subway stations, civil use of groundwater, and leaking water from water supply and sewage lines. So the characterization and evaluation of tile groundwater flow and contaminant transport in the Cheonggyecheon water system is quite a difficult task. The purpose of this study is to analyze of the influence to the 'groundwater' below the Cheonggyecheon watershed by the 'surface water' on the Cheonggyecheon stream after the restoration. We have so far collected groundwater quality data, hydrogeologic aquifer parameters, and tile amount of leakages into subway stations and its influence on the groundwater system of the Cheonggyecheon. Results show that groundwater level was influenced by the direction and depth of a 녀bway station. This study will continue to monitor groundwater quality, a water level fluctuation relation between rainfall and groundwater recharge for further investigation of the groundwater flow system in Cheonggyecheon.

  • PDF

Development of a Data-Driven Model for Forecasting Outflow to Establish a Reasonable River Water Management System (합리적인 하천수 관리체계 구축을 위한 자료기반 방류량 예측모형 개발)

  • Yoo, Hyung Ju;Lee, Seung Oh;Choi, Seo Hye;Park, Moon Hyung
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.4
    • /
    • pp.75-92
    • /
    • 2020
  • In most cases of the water balance analysis, the return flow ratio for each water supply was uniformly determined and applied, so it has been contained a problem that the volume of available water would be incorrectly calculated. Therefore, sewage and wastewater among the return water were focused in this study and the data-driven model was developed to forecast the outflow from the sewage treatment plant. The forecasting results of LSTM (Long Short-Term Memory), GRU (Gated Recurrent Units), and SVR (Support Vector Regression) models, which are mainly used for forecasting the time series data in most fields, were compared with the observed data to determine the optimal model parameters for forecasting outflow. As a result of applying the model, the root mean square error (RMSE) of the GRU model was smaller than those of the LSTM and SVR models, and the Nash-Sutcliffe coefficient (NSE) was higher than those of others. Thus, it was judged that the GRU model could be the optimal model for forecasting the outflow in sewage treatment plants. However, the forecasting outflow tends to be underestimated and overestimated in extreme sections. Therefore, the additional data for extreme events and reducing the minimum time unit of input data were necessary to enhance the accuracy of forecasting. If the water use of the target site was reviewed and the additional parameters that could reflect seasonal effects were considered, more accurate outflow could be forecasted to be ready for climate variability in near future. And it is expected to use as fundamental resources for establishing a reasonable river water management system based on the forecasting results.

Recycling of a discarded septic tank as a rainwater management system and it's economic feasibility analysis (폐정화조를 재활용한 다목적 빗물관리시스템 구상 및 경제성 분석)

  • Kim, Mikyeong;Kwak, Donggeun;Han, Mooyoung;Yang, Jichung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.647-654
    • /
    • 2009
  • Since the end of the 1990s, sewer pipe improvement works have been going on: most septic tanks have been thrown away and discarded. These discarded septic tanks amounts up to 370,000 based on the project plan 2005-2008: it is a serious squander of nation's resources, a contaminating means that buries toxins under soil, and a cause of a expensive waste. Research on recycling of discarded septic tank as a new resource is in urgent need. This research suggests plans to recycle discarded septic tank as a rainwater management facility, solutions to water cycle recovery in the limelight, and economic analysis of the plan. In the case of a recycling discarded septic tank as a rainwater management facility will socially benefit to support economical adequacy, discard cost saving of septic tank and water supply and sewage cost reduction will come out. Consequently a rainwater management facility converted from a discarded septic tank leads to decentralization of the rainwater management system, which anticipates a positive effect on recovery of urban water cycle.

Analysis of project-level elements of a smart city: A case study

  • Kisi, Krishna P.;Bhattarai, Sushmit Sharma
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1001-1008
    • /
    • 2022
  • As a part of the Smart Cities Mission, the Government of India in 2015 embarked upon the development of 100 existing cities as smart cities. In this study, the authors selected Ahmedabad city as the smart city development in India and presented project-level elements of the city based on the secondary data availability. At first, the authors focused on peer-reviewed articles, policy documents, and technical reports. Next, the authors collected the secondary data of project-level elements of the Ahmedabad city from the years 2015 to 2019. The findings show no significant improvement in the sewage system and waste collection as compared to the level of investment made in these sectors. The study showed that the water supply system outperformed revenue generation based on the government investment made in that sector. As a lesson learned, these findings indicate that significant improvement should be addressed in sewage management and waste collection. These study findings could help government officials, investors, developers, and city planners in making the appropriate decision before and during smart city execution. The lesson learned from this study could be used as a reference to improve revenue during the future smart city implication.

  • PDF