• Title/Summary/Keyword: Water supply & sewage system

Search Result 61, Processing Time 0.027 seconds

A Study on the Rational Planning of Water Supply and Sewage System for Rural Village Development Projects (농촌마을종합개발사업에서 상하수도시설의 합리적 계획방향에 관한 기초적 연구)

  • Kim, Hwan-Yong
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.8 no.2
    • /
    • pp.62-71
    • /
    • 2006
  • This study on the rational planning of water supply and sewage system for rural village development projects. Present, when establishment and standard about maintenance of water supply and sewage system were not presented in rural village synthesis development projects, it is real condition that service industry is depending on presenting simple plan in basis planning phase and business enforcement step. This study wishes to present basic data so that can be planned more rationally and enforce and contribute in rural village synthesis development projects water supply and sewage system that is enforced as part of rural village synthesis development projects.

  • PDF

A study on Determination Method of the Compliance Concentration of Effluent Limitation from Public Sewage Treatment Works in the Jinwee-stream Watershed Sewer System (유역하수도 공공하수처리시설의 방류수 수질 준수농도 설정방안 연구: 진위천 수계를 중심으로)

  • Jeong, Dong-Hwan;Cho, Yangseok;Kim, Youngseok;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.493-502
    • /
    • 2015
  • In accordance with the Watershed Sewer System Maintenance Plan enforced on February 2, 2013, the different compliance concentration of effluent limit be applied to effluent discharged from public sewage treatment works(PSTWs) in each watershed on the basis of water quality thereof. With the introduction of watershed sewer system, it is necessary to set the compliance concentration of effluent limit for PSTWs situated in the watershed, by region and PSTW size, to achieve water quality criteria for regional watersheds or target water quality under TMDL program. Watershed Environmental Agencies establish the Watershed Sewer System Maintenance Plan and set the compliance concentrations of effluent limit for PSTWs under the plan. The agencies plan to apply tougher effluent BOD concentration limits in Class I to IV areas. Effluent BOD concentration limits will be toughened from 5~10 mg/L to 3 mg/L in class II~III areas, from 10mg/L to 5mg/L in class IV areas. Uniform application of effluent BOD concentration limits to PSTWs in the watershed sewer system need to be complemented considering type of sewage treatment technology employed and watershed characteristics. Therefore, this study presents method to determine the compliance concentration of effluent limit from PSTWs in the watershed.

The System Improvement of the Individual Sewage Treatment System (개인하수처리시설의 제도개선에 관한 연구)

  • Jang, Hyo-Ju;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2010
  • Individual sewage treatment system is classified into a sewage treatment system which treats all the domestic sewage and a water-purifier tank which treats only effluent flushing from the toilet. The number of registered manufacturers has increased rapidly since 2001. As a result, price competition has increased among the manufacturers and has caused the problems such as the inappropriate production of individual sewage treatment system, the unreasonable permit for building completion and the shortage of the professional technology of the community's public officials in charge. This study collected the problem cases that are related with existing individual sewage treatment system and operation. Efficient improvement plan for the stable supply, installation, maintenance of individual sewage treatment system were suggested.

A mini-review on discharge characteristics and management of microplastics in sewage treatment plants (국내·외 연구사례를 통해 본 하수처리시설 미세플라스틱 배출특성 및 관리방안 고찰)

  • Jeong, Dong-Hwan;Ju, Byoungkyu;Lee, Wonseok;Chung, Hyenmi;Park, Junwon;Kim, Changsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.4
    • /
    • pp.337-348
    • /
    • 2018
  • As the issue of microplastics (MPs) detection in tap water was raised in other countries in 2017, monitoring of MPs in drinking and source water, and sewage treatment plant (STP) effluents was initiated. This study intends to look into other studies on MPs in STPs at home and abroad, and review the characteristics of MPs and their removal efficiencies in the STPs, the risk and effect of MPs on watersheds, and management practices in order to help better understand MPs in STPs. To manage MPs effectively in STPs, it is necessary to investigate the detection of MPs discharged from STPs, do research on human health risk and control measures, and build a monitoring system including standardized analytical methods.

Reconstruction of North Korean Water Infrastructure: Present Status and Future Challenge (북한 상하수도 인프라 재구축: 현황과 전망)

  • Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.641-650
    • /
    • 2008
  • This paper reviews the infrastructure of the water supply and sewerage system in North Korea. North Korean has similar legal protection to preserve water environment that can be seen in Republic of Korea, but North Korean regulations seemed lack of detailed measures. The critical pollution problems of rivers and lakes in the northern part of peninsula is mainly due to the lack of sewage collection system and poor treatment works. It has been estimated that less than 20% of sewers are connected to the wastewater treatment plants. Although the availability of water resources seemed sufficient, North Koreans suffer the lack of the drinking water supply which needs an urgent attention. Based on the analysis, it has been suggested that the reconstruction of North Korean water and sewage infrastructure needs at least 17.5 trillion Korean Won.

A study on the Effect of SOB(Sulfur-Oxidizing Bacteria) Media on the Removal of Hydrogen Sulfide in Water of Septic Tank (SOB(Sulfur Oxidizing Bacteria) Media가 정화조의 수중황화수소 제거에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil;Kim, Taeksoo;Kwon, Sucheol;Yu, Hyeongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.59-67
    • /
    • 2013
  • The odor occurring in the sewage system induces the displeasure, the disgust such as the headache, the vomit, etc. and increases the spiritual stress and disturbs the pleasant life of residents. These odors occur mainly in the area of combined sewage system treatment, being created in the personal sewage treatment plant such as septic tank and are incoming to sewage pipes and emitted to the outside through the manhole and the receiver, etc.; and this causes odors to the people. The Hydrogen Sulfide, the Methyl Mercaptan, the Ammonia, etc. are materials causing the odor, the more serious issue of odor is occurring since the septic tank of degradation process is being applied. The primary cause of odor is the decomposition of human feces in the septic tanks and sewage disposal facilities. The purpose of this study is reduction of hydrogen sulfide using air supplying and SOB(Sulfur-Oxidizing Bacteria). As a result of this study of the air supply system and the SOB media equipment by air supply, in case the air is injected to SOB media compared to the injection of air only, the removal efficiency the hydrogen sulfide was average 3.4 times higher.

Research on Managing Underground Facilities for an Intelligent City

  • Kim, Jung-Hoon;Lee, Jae-Yong
    • Spatial Information Research
    • /
    • v.16 no.4
    • /
    • pp.421-439
    • /
    • 2008
  • The objective of this project is to construct the intelligent underground facility management system based on UFSN (Underground Facility Sensor Network). Total project duration is 6-year. And first two years' project has been finished. First two years' project focused on water supply and sewage facilities among 7 underground facilities and investigated the fundamental construction technology for the underground facilities management system. To contribute the development of systematic and scientific management of underground facilities, KRIHS implemented 3 researches for 'Underground facilities management system for an intelligent city' like followings: (1) to investigate an integration plan for current water supply and sewage management systems, (2) to derivate of water supply and sewage monitoring items for the monitoring technology development, and (3) to implement a basic research for sensor installation plans on different types of current and new underground facility systems. This research paper contains the first two years' outcome of researches from KRIHS (Korea Research Institute for Human Settlements).

  • PDF

Improvement on Sewerage Effluent Standard of Public Sewerage Treatment Plants (공공하수처리시설 수질기준 선진화 방안)

  • Yu, Soon-Ju;Park, Sang-Min;Kwon, Oh-Sang;Park, Su-Jeong;Yeom, Ick-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.276-287
    • /
    • 2013
  • Domestic sewage contains increasingly more pharmaceuticals and personal care products (PPCPs), due to rising use of medicines, health supplement food and daily necessities. And various types of industrial wastewater from pollution sources in treatment areas could flow into the public sewerage treatment plants (PSTPs) in metropolitan areas. The conventional PSTPs are designed to treat suspended solids, biodegradable organics, nitrogen and phosphorous from residential and industrial areas and public facilities. However, toxic, conventional, and non-coventional pollutants from non-domestic sources that discharge into sewer system as well as domestic source with various chemicals could not be treated in the conventional PSTPs and discharged untreated to public basin. In this paper we aim to consider the establishment system of effluent standard of PSTPs in comparison with water quality standard of water environment and wastewater discharge regulation. And also we suggest the necessity of regulations on the pretreatment of industrial wastewater as part of efforts to improve water quality in sewerage systems and to protect public basin.

A study on the device introduction of wastewater reclamation system a treated sewage (하수처리수를 활용한 중수도의 도입방안 연구)

  • Park, Rho-Sam;Park, Sang-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.23-33
    • /
    • 1999
  • After studying several methods of the application a device of a treated sewage in anticipation of the future shortage of the duty of water, we could have some conclusion as the following : Advanced treatment systems arc essential prerequisites in reusing a treated sewage. And in a short term, the application of reusing a treated sewage should go first to new building areas near the sewage but for the long run, it should cover the whole area of Taegu, it is desirable that the pipe line networks which include dual water systems as well as water supply should be spread throughout the whole city. The city authorities have to make every effort to step up publicity activities on this plan to all the citizens and building owners to steadily carry out this project and encourage private constructors to participate with the help of SOC. And for the long run, it is desirable that the application of reusing a treated sewage should be obligatory.

  • PDF

A Study on The Operation Characteristics of 2-Stage Compression Heat Pump using Treated sewage (하수처리수를 이용한 2단 압축 열펌프 시스템의 운전특성에 관한 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Lee, Young-Soo;Chang, Ki-Chang;Ra, Ho-sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.299-303
    • /
    • 2008
  • The treated sewage temperature is about $5^{\circ}C$ lower in summer and $5{\sim}10^{\circ}C$ higher in winter than ambient air. It can be used heat pump heat source and is good heat source on high performance of heat pump. In this study, to develop 100RT 2-stage compression heat pump use treated sewage water heat source and system applies to sewage disposal plant. Although heat pump is better performance, the large temperature difference between load and source makes the performance degradation of a heat pump. To solve this problem screw 2-stage compression is considered. The experiment was focused on the system operating performance variations over supply water and treated sewage water a temperature in the field. The results show that system of heating performance is higher then general heat pump and is enough to supply a hot water of $70^{\circ}C$.

  • PDF