• Title/Summary/Keyword: Water spray system

Search Result 271, Processing Time 0.032 seconds

Analysis of Hydrogen Fuel for Existing Domestic Boilers and New Heat Recovery Boilers with Water Spray (기존 가정용 보일러 및 신형 물분사 폐열회수 보일러에 대한 수소 연료의 평가)

  • LEE, CHANG-EON;KIM, DAEHOON;PARK, TAEJOON;MOON, SEOKSU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.2
    • /
    • pp.210-222
    • /
    • 2020
  • Hydrogen is evaluated as one of new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is free from CO2, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. This study investigates the differences in operating characteristics and its problems to be modified when the hydrogen is used as fuel for existing domestic boilers and new heat recover boilers with water spray. When the hydrogen is used in domestic boilers, the efficiency is about 6-7% lower than methane due to higher partial vapor pressure in the exhaust gas at usual operating conditions above 60℃ in combustion chamber outlet temperature. On the other hand, the heat recovery boiler with water spray (HR-B/WS-X) is expected to achieve up to 95% efficiency, which is 12% more efficient than conventional boilers. It can also significantly reduce NOx emission by lowering the flame temperature.

Development of for Mineral Salt Manufacturing System using Deep Sea Water (해양 심층수를 이용한 미네랄소금 제염장치 개발)

  • Kim H. J.;Shin P. K.;Moon D. H.;Jung D. H.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.183-189
    • /
    • 2004
  • Deep ocean water is located in the sea deeper than 200m. At such depth the solar light does not reach, photosynthesis is not performed and nutrition salt is not consumed. Therefore, campared with surface water, Deep Sea Water contains more nutrition salt, such as nitrogen and phosphor. Moreover, it has the good balance of minerals. This Research is primary attempt for apply deep sea water to food industry. New type of mineral salt manufacturing system was developed and high levels of Ca, K, Mg detected from the salt analysis.

  • PDF

A Study on the Fire Suppression Characteristics of a Flame Arrester with Water Mist System (미분무 시스템이 장착된 화염방지장치의 화재 진화 특성에 관한 연구)

  • Kim, Hae-Ji;Lee, Kyung-Ro
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.117-124
    • /
    • 2016
  • In this paper, we developed a breather valve with a water mist system for use near an oil storage tank. Our process applied a water mist system to the flame arrester to evaluate the fire suppression characteristics. For the fire suppression evaluation of the water mist system, we evaluated the angle of the nozzle, fire suppression, spray particle size, flashback, fire suppression time, and fire suppression test of antifreeze. Through the fire suppression test, the best fire suppression nozzle used an angle of $140^{\circ}$, and the flashback phenomenon of flame arrester did not occur. The fire suppression time of water mist system time was within three seconds, and the antifreeze was no problem with the fire suppression.

Extinguishing of Oil Fire by Water Mist Suppression System Using Compressed Inert Gas (불활성 압축가스를 이용한 미세물분무 소화시스템의 유류화재 소화특성)

  • Shin, Chang-Sub;Jeon, Go-Un;Kim, Ki-Whan
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.109-114
    • /
    • 2010
  • Water mist fire suppression system is environmental system and needs a flange pump to jet water. In this research, high pressure Nitrogen cylinder is used as a pressurizing source instead of flange pump, and also we tried to find the possibility of using compressed Nitrogen as a fire suppression agent. As a result, it was possible to design water mist fire suppression system with Nitrogen cylinder and suppress oil fire effectively. With DK1.58 nozzle, the optimum Nitrogen pressure was 80bar and the pressure was stable during water mist spray. However, jet of Nitrogen was not effective fire suppression agent when it was dually used with water mist because water mist has blown away, and it is efficient way to use compressed Nitrogen as a pressurizing source only.

A Study on the Various Characteristics of Ultrasonic-Energy-Added W/O Type Emulsified Fuel ( I ) - attaching importance to stability and spray characteristics - (초음파에너지 조사 W/O type 유화연료의 제반특성에 관한 연구(I) - 안정성 및 분무특성을 중심으로 -)

  • Kim, Yong-Cheol;Song, Yong-Sik;Ryu, Jeong-In
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.22-28
    • /
    • 2004
  • This study is concerned about the characteristics of ultrasonic-energy-added W/O type emulsified fuel. The distilled water was mixed with diesel oil by using ultrasonic energy fuel feeding system and then the SMD of sprayed droplets was measured to find out atomization characteristics of emulsified fuel by using the Malvern 2600 system. The capacitance value was measured to verify stability of the same specimen by using the digital LCR meter, EDC1630 additionally. The main results are as follows; 1) The more measuring distance increases between one hole nozzle tip and analyser bearm, the more SMD increases. 2) The more water content increases, the more capacitance value increases depending on the time. Main Parameters of the study are the amount of water content $0{\sim}30%$ by 5% in emulsified fuel, and the measurement distance, $20{\sim}140mm$ by 10mm or 20mm between nozzle tip and analyser beam.

  • PDF

Effect of Spray System on Fission Product Distribution in Containment During a Severe Accident in a Two-Loop Pressurized Water Reactor

  • Dehjourian, Mehdi;Rahgoshay, Mohammad;Sayareh, Reza;Jahanfarnia, Gholamreza;Shirani, Amir Saied
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.975-981
    • /
    • 2016
  • The containment response during the first 24 hours of a low-pressure severe accident scenario in a nuclear power plant with a two-loop Westinghouse-type pressurized water reactor was simulated with the CONTAIN 2.0 computer code. The accident considered in this study is a large-break loss-of-coolant accident, which is not successfully mitigated by the action of safety systems. The analysis includes pressure and temperature responses, as well as investigation into the influence of spray on the retention of fission products and the prevention of hydrogen combustion in the containment.

Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater (축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.

Spray and Depositional Characteristics of Electrostatic Nozzles for Orchard Sprayers (과수 방제기용 정전대전 노즐의 분무 및 부착특성)

  • 강태경;이동현;이채식;이공인;최완규;노수영
    • Journal of Biosystems Engineering
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2004
  • Spraying is one of the most efficient methods for pesticide and insecticide control. Generally, orchard sprayers(aircarrier sprayer) are used for such applications. However, when an orchard sprayer is used, only 20% of total amount of spray deposits on the target. The rest of spray are not only wasted but are also potential sources of environmental pollution. The research far the development of electrostatic spraying system for orchard sprayer was conducted to develop the new pesticide application technology for the reduction of environmental pollution and f3r the production of safe agricultural products. The spray characteristics for nozzles with the different charging methods were tested and the effect of electrostatic charge was analyzed, in the laboratory experiments. The results of this study indicate that the capacitive type of electrostatic spraying nozzle exhibits a large current deposition of water sprays on the sample target. The covering area ratio by conventional spraying system was 10.2%, while that of electrostatic sprays with pulse induction charging method gave the increased covering area ratio by 4.3 times.

Removal Efficiency of Some Odorants against Water as Sorptive Media: A Case Study on Trimethylamine and Reduced Sulfur Compounds (물을 흡수매체로 이용한 트리메틸아민과 환원황화합물의 제거효율 비교 연구)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Ok, Joon-Seok;Kim, Yong-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.512-522
    • /
    • 2009
  • In this study, the removal efficiency of trimethylamine (TMA) and four reduced sulfur compounds (RSC) of $H_2S$, $CH_3SH$, DMS, and DMDS was investigated using deionized water as absorbent. To this end, two types of experiments were conducted which include: (1) by passing both RSC and TMA standard gases through water contained in an impinger system and (2) by passing TMA gases through a water spray system. In the former method, TMA standard gases were effectively removed (below detection limit) in all experiments. Likewise, minor fractions of some RSC ($CH_3SH$, DMS, and DMDS) were removed by water in line with theoretical expectations. In addition, the first type of our experiment was extended further to test some commercially available odor treatment products. The results of this test showed that removal efficiencies of RSC $(8.2\pm13.7\sim43.7\pm2.48%)$ were different significantly among 4 kinds of absorbent, while the removal of TMA was consistently good as water. In the second phase of experiment, removal efficiency of TMA was tested by passing its standard gas through a water spray system. The overall results of our study showed that the actual removal efficiency of odorants by water (as sorptive media) approached the values that can be predicted theoretically (by Henry's law).