• Title/Summary/Keyword: Water space

Search Result 2,364, Processing Time 0.029 seconds

Model Design for Water Wheel Control System of Heumgyeonggaknu

  • Kim, Sang Hyuk;Ham, Seon Young;Lee, Yong Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • Heumgyeonggaknu (欽敬閣漏) is powered by a water-hammering-type water wheel. The technique that maintains the constant speed of the water wheel is assumed to be the one used in the Cheonhyeong (天衡) apparatus in Shui Yun Yi Xiang Tai (水運儀象臺) made by the Northern Song (北宋) dynasty in the 11th century. We investigated the history of the development and characteristics of the Cheonhyeong apparatus, and we analyzed ways to transmit the power of Heumgyeonggaknu. In addition, we carried out a conceptual design to systematically examine the power control system. Based on the conceptual design, we built a model for a water wheel control system that could be used in experiments by drawing a 3D model and a basic design.

Establishment of Design Standard and Analysis of Insulation Property for Underground Space in Architecture (건축물의 지하공간을 위한 단열재의 특성 분석 및 설계 기준 수립)

  • Hwang, Min-Kyu;Cho, Woo-Jin;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • The purpose of this study is to analyze an insulation property and to establish a design standard for the underground space in architecture. Insulation materials for this study are 12 kinds of Insulation which qualified KS standards(3 classes of EPS type 1, 3 classes of EPS type 2(Neopor), 3 classes of XPS and 3 classes of PU Boards). For insulation materials of underground space, insulating and water tightening property are desired. So conductivity for insulating and water absorption for water tightening are measured in this study. Temperature, insulation is exposed to in the underground space, is different from temperature above the ground. Conductivity is measured in a temperature of $17^{\circ}C$, $20^{\circ}C$, $23^{\circ}C$ and $26^{\circ}C$. In KS standards, water absorption are measure after 24 hours, but insulation is exposed to water for a long time in the underground. So after 110 days, water absorption are measured. As time goes by, increasing of water absorption means decreasing of water tightening and insulating. So after water absorption had measured for 110 days, conductivity has measured again. As a result, XPS is selected as optimized insulation for underground. And Conductivity of XPS insulation with water should be added by 20%.

A Study on the Transition of Water Spaces (수공간 변천에 관한 연구)

  • Min, Young-Gi;Lee, Jae-Kook
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.7 no.2
    • /
    • pp.67-72
    • /
    • 2007
  • Water plays significant roles in constructing architectural structures. This is because a comfortable human life is impossible without proper distribution of water. Here the notion of water space is introduced in the field of the modern architecture. This study examines the typological variations of water space in the outdoor space of architectural structures and concludes the contents discussed. Unlike the traditional architecture, the modern architecture takes the types of water into account. And in the modern architecture the multiple considerations of water space are being made for the public, not for the specific customers.

  • PDF

A Study on Attribute of Water and Exhibition Composition - Focused on Four-major River Water Culture Pavilion in Korea - (물의 속성과 전시연출에 관한 연구 - 4대강 물문화관을 중심으로 -)

  • Song, Hyeon-Ji;Kim, Nam-Hyo
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.5
    • /
    • pp.355-362
    • /
    • 2012
  • Water Culture Pavilion was constructed as a part of dam construction and Four-major rivers restoration projects, which have the purpose to prevent damage of natural disaster, localized heavy rain and drought, and has several functions; promotion, education and region culture community. Exhibition space in this culture pavilion should have the excellent connection of various media, contents, and exhibition space because of limited space. The purpose of this study is to analyze flows, continuation and connection of exhibit space with the perspectives of the attribute of water and to suggest various content things, technical, spatial types. This study targets Four-major rivers Water Culture Pavilion in Korea and suggests exhibition presentation methods as analyzing contents, media and constituent of exhibition space for each pavilion exhibition. The result of this study is as follows : First, the circulation is common expressed attribute of water in these four water culture pavilion. The reason is that there is a connection between Four-major rivers restoration projects and the physical attribute of water circulating the steps of evaporation, condensation and precipitation. Second, each pavilion presents circulative solid exhibit, circulative background exhibit, circulative reflective exhibit based on circulation. These three types of exhibition is related the floor separation. Third, each pavilion exhibit zone shows the most circulation, solid, background, reflexibility through educational contents and promoting contents by using graphic, video, sound media.

  • PDF

Thermal Performance of Solar Hot Water and Space Heating in a Combi - Storage Tank (태양열 급탕 난방 복합 축열조 열성능)

  • Kwak, Hee-Youl;Joo, Hong-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.266-269
    • /
    • 2009
  • The Purpose of this study was thermal performance of solar hot water and space heating thermal storage tank. The combi storage tank was designed Tank in Tank type. The tank volume for space heating was 700 $\ell $ and tank volume for hot water was 150 $\ell $. Tank in Tank type storage tank was to replace heat exchange to hot water tank. The result showed that the Heating value was 67.25MJ and domestic hot water value was 51.93MJ. Supply to the hot water volume was 521 $\ell $ more than about 3 times as that of the hot water tank volume.

  • PDF

Water Mist Fire Suppression for Raised Subfloor Spaces

  • Kim, Woon-Hyung;Kim, James A. Milke
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.617-624
    • /
    • 1997
  • Over 100 experiments have been conducted at the University of Maryland to evaluate the performance of a water mist fire suppression system for protection of an interstitial space below a raised subfloor. Experiments are conducted as part of an ongoing research effort to compare the fire suppression capabilities of various water mist system designs in a raised subfloor space. Water mist system design parameters considered in the investigation include means of actuation, concentration of water mist required for extinguishment of fires, and delivery mechanisms of water mist within close proximity to the fire. Delivery of the required concentration of water mist within close proximity to the fire is a principal factor governing the adequacy of water mist systems. Two sets of experiments have been conducted to document the performance of water mist system designs. One set is involved in documenting the concentration of water mist as a function of position within the space. The second set of experiments is concerned with the ability of water mist system designs to control fires in the space. One result of the research is the assessment of the ability of a water mist system to control fires at particular locations as a function of water mist density at that location.

  • PDF

PRECIPITABLE WATER VAPOR CONDITIONS FOR INFRARED OBSERVATIONS AT KOREAN ASTRONOMICAL OBSERVATORIES (국내 천문대 상공의 수증기량 조건과 적외선 관측)

  • Lee, Sung-Ho;Baek, Jeong-Ho;Moon, Bong-Kon;Jin, Ho;Cho, Jung-Ho;Cha, Sang-Mok;Cho, Seoung-Hyun;Park, Yung-Sik;Yuk, In-Soo;Nam, Uk-Won;Pak, Soo-Jong
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.339-348
    • /
    • 2007
  • KASINICS (Korea Astronomy and Space Science Institute Near Infrared Camera System) is equipped with a InSb array which can observe $1-5\;{\mu}m$ bands in near-infrared. The absorption and emission by telluric water vapor becomes serious in the bands longer than $3\;{\mu}m$. We measured PWV (precipitable Water Vapor) levels above Bohyusan Optical Astronomy Observatory and Sobaeksan Optical Astronomy Observatory from July 2006 to August 2007 using the GPS PWV measurement system of KASI. We found that monthly averaged PWVs are lower than the prediction using dew-point temperature and as low as above Kitt Peak from September to February.

The evaluation of background sound satisfaction when interior sound source and landscape are provided in various types of space (공간 유형별 실내조경에서의 배경음 만족도 연구)

  • Kim, Ho-Gon;Kook, Chan;Baek, Geon-Jong
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.83-88
    • /
    • 2012
  • As for the generally preferred sound sources used in the test, the sound of water and the birds chirping were highly valued. And they have found that preference of the subject is increased if background music which mixed well with the sound sources were provided together. On the other hand, the sound sources of low satisfaction were judged at be church bells, bell of Emile, and fulling cloth, which not mix well with interior landscaping. If the physical elements of interior landscaping were equally composed, it has found that the larger were a of water space is, the higher satisfaction more than other sound sources. Average satisfaction of background sound in interior landscaping classified according to the characteristics of space has found that satisfaction of the birds chirping and music in working space and satisfaction of water sound and music in commercial space were high. Women judged that satisfaction of the birds chirping and music in working space and satisfaction of water sound and music in commercial space whose values were the same with the average ones were high, while men judged that satisfaction of the song of birds and music in working and commercial space is high.

Analysis on Characteristics of Radiosonde Bias Using GPS Precipitable Water Vapor

  • Park, Chang-Geun;Baek, Jeong-Ho;Cho, Jung-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.3
    • /
    • pp.213-220
    • /
    • 2010
  • As an observation instrument of the longest record of tropospheric water vapor, radiosonde data provide upper-air pressure (geopotential height), temperature, humidity and wind. However, the data have some well-known elements related to inaccuracy. In this article, radiosonde precipitable water vapor (PWV) at Sokcho observatory was compared with global positioning system (GPS) PWV during each summertime of year 2007 and 2008 and the biases were calculated. As a result, the mean bias showed negative values regardless of the rainfall occurrence. In addition, on the basis of GPS PWV, the maximum root mean square error (RMSE) was 5.67 mm over the radiosonde PWV.

Analysis on the Mitigation Effects of Urban Heat Island through Creation of Water Space - A case study of Yeol-Mae village Apt in Daejeon's Noeun District - (수공간 조성을 통한 도시의 열섬현상 저감효과 분석 - 대전시 노은지구 열매마을아파트를 중심으로 -)

  • Park, Ki-Yong;Lee, Sun-Woo;Shim, Young-Ju;Hwang, Hee-Yun
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.13-18
    • /
    • 2011
  • The overall aim of this study is to mitigate urban environmental problems. In particular, to reduce the effects of urban heat island phenomenon which is one of the urban planning perspective. This study focused on the analysis of the relationship between the urban heat island effect and the thermal and wind properties. To do this analysis, water space was virtually made at Yeol_Mae village Apt. Because it is very difficult to set up water space for the existing apartment complexes due to realistic constraints. This study, therefore has a strong sort of guidelines to create water space for newly formed city. It was based on the concept of virtual city through an in-depth analysis on reduction of urban heat island effects for the existing apartment along with creation of water space. To analysis site, Envi-Met Model developed by Michael Bruse was used. The results are as follows. The temperature went from 298.9K to 297.82K and The wind speed went from 1.42m/s to 1.43m/s. The results are slight in this study because creation of water space is planned to a small area of an apartment complex. But if the water space would be applied to a whole city, the mitigation effect of urban heat island would be bigger.