• Title/Summary/Keyword: Water space

Search Result 2,376, Processing Time 0.033 seconds

A fundamental study of slurry management for slurry shield TBM by sea water influence (해수의 영향에 따른 이수식 TBM의 슬러리 관리를 위한 기초적 연구)

  • Kim, Dae-Young;Lee, Jae-won;Jung, Jae-Hoon;Kang, Han-Byul;Jee, Sung-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.463-473
    • /
    • 2017
  • Bentonite swells when it comes into contact with water and makes it a viscous fluid. Thus it is widely used in civil engineering works for waterproofing. Utilizing the properties of bentonite, the slurry shield TBM supports excavated face with pressurized slurry as well as transporting excavated muck. When bentonite is in contact with seawater, due to the change of double layer thickness, its expandability and viscosity are lowered. This may cause problems for excavation stability and muck discharge due to the increase of sea water inflow when Slurry TBM is used under sea water conditions. In this study, the change of slurry condition caused by the inflow of sea water during tunnel excavation with Slurry TBM was investigated and a slurry management guideline was proposed. For this purpose, a laboratory test was carried out based on the slurry management criterions applied in the field, and a method applicable to the field where sea water is affected has been proposed.

Abiotic environment and primary producer of estuarine pelagic ecosystem in the lower water of the Mankyung river and the Dongjin River I. Environmental characteristics and phytop (만경, 동진강 하구 표영생태계의 무생물 환경과 일차생산자 I. 환경 특성과 식물 플랑크톤의 군집 구조)

  • 심재형;신윤근
    • 한국해양학회지
    • /
    • v.26 no.2
    • /
    • pp.155-168
    • /
    • 1991
  • In order to study the community structure and distribution patterns of primary producers and their relations to abiotic environmental factors, phytoplankton and environmental parameter were determined during the five times from October, 1989 to July. 1990. 159 taxa of phytoplankton have been identified and the most important species group is diatom which contributes to 70.4% of the total number of species. Ratios of phytoplankton group (neritic species, fresh water species, oceanic species) clustered by habitats were 52%, 18%, 12%, respectively, suggesting study area be the typical estuarine environment which is strongly affected by both fresh water discharge and sea water penetration. Species composition could be governed by the variations of salinity. the standing stocks of primary producer in the study area vary with space and time, showing close correlation with water transparency, and exhibit relatively larger than those of other coastal regions in the Yellow Sea. Spectransies diversity also showed large variation with space and time. According to the cluster analysis, the study area could be divided into two regions (inner part and outer part): in fall and winter, outer area affected by the oceanic water, but in spring and summer, inner estuarine area heavily influenced by fresh water.

  • PDF

Development of Testing and Analysis Model for Evaluation of Absorbed Water Diffusion into Concrete (콘크리트 흡수 수분확산계수 산정을 위한 실험 및 수치해석 모델 개발)

  • Park, Dong-Cheon;Ahn, Jae-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.371-378
    • /
    • 2011
  • Concrete is affected by various deterioration factors, such as $CO_2$ and chloride ions from the sea, which cause carbonation and salt attack on concrete. These deterioration phenomena cause steel corrosion in RC structures. Although a great deal of research has been carried out in this area thus far, it is difficult to know the point at which corrosion will occur to a reinforced bar. As the diffusion of deterioration factors depends on the water content in concrete, it is imperative to assess the condition of absorbed water content. A mass measuring method was applied to calculate the absorbed water diffusion coefficient, as well as non-linear finite element method(FEM) analysis. As a result, it was found that W/C and unit water content in concrete mixture affect the diffusion coefficient decision.

Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating (온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

Analysis of geological conditions and water bearing zones in front of tunnel face using TSP (TSP탐사를 이용한 터널 굴착면 전방 지질상태 및 함수대 분석)

  • Kyounghak Lim;Yeonjun Park
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.5
    • /
    • pp.373-386
    • /
    • 2023
  • To analyze the prediction of geological conditions and water-bearing zones, TSP was performed in the collapse zone of the fault zone. The results of the TSP were verified by comparing them to the face mapping results of the prediction zone. The rock quality prediction result of the TSP had an error of about 3 to 10 meters compared to the face mapping result, but the overall rock quality change and ground condition were analyzed to be relatively similar. In the water-bearing zones of the face mapping results, the Vp/Vs ratio ranges from 1.79 to 2.37 and the Poisson's ratio ranges from 0.27 to 0.39. In the sections other than the water-bearing zones, the Vp/Vs ratio ranges from 1.61 to 1.89, and the Poisson's ratio ranges from 0.19 to 0.3. As a result of analyzing the Vp/Vs ratio and Poisson's ratio in the water-bearing zones, it is analyzed that the sections with a Vp/Vs ratio of 2.0 or more and a Poisson's ratio of 0.3 or more have a high possibility of being water-bearing zones.

Korean Contribution to All-Sky Near-infrared Spectro-Photometric Survey

  • Jeong, Woong-Seob;Pyo, Jeonghyun;Park, Sung-Joon;Moon, Bongkon;Lee, Dae-Hee;Park, Won-Kee;Lee, Duk-Hang;Ko, Kyeongyeon;Kim, Il-Joong;Kim, Minjin;Yang, Yujin;Ko, Jongwan;Song, Yong-Seon;Yu, Young Sam;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shim, Hyunjin;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.37.3-37.3
    • /
    • 2016
  • The SPEHREx (Spectro-Photometer for the History of the Universe Epoch of Reionization, and Ices Explorer) is one of the candidates for the Astrophysical Small Explore mission of the NASA proposed together with KASI (PI Institute: Caltech). It will perform an all-sky near-infrared spectral survey to probe the origin of the Universe and water in the planetary systems and to explore the evolution of galaxies. The SPHEREx is designed to cover wide field of view of $3.5{\times}7deg$. as well as wide spectral range from 0.7 to $4.8{\mu}m$ by using four linear variable filters. The SPHEREx is under the Phase-A study to finalize the conceptual design and test plan of the instrument. The international partner, KASI will contribute to the SPHEREx in the hardware as well as the major science cases. The final selection will be made in the early 2017. Here, we report the current status of the SPHEREx mission.

  • PDF

A Study on the application of landscape material in commercial space design (상업공간디자인에 있어 자연경관 요소의 적용에 관한 연구)

  • Woo, Ji-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.3
    • /
    • pp.43-50
    • /
    • 2008
  • Commercial space, the types of which have been increasingly various and changing rapidly, has been generating new marketing concepts for space. Especially as the environmentally friendly lifestyle spreads around, the component of natural landscape such as plant, stone, or water has been used as an important part in space design, freshly imprinting the brand image beyond the idea of simple interior property. By combining commercial space design with 'the component of the natural landscape', we can improve the brand image, create the newness in the space, lead customers to stay longer in the space, and reinforce the decorative effect. The parts of the commercial space to which we can apply the element of natural landscape are facades, walls, floors, and show windows. Various examples of real application are found according to the areas of business and goods displayed. This thesis attempts to maximize the effect of commercial space by examining and analyzing various instances of space and provide the ways of applying the space that contains an aesthetic value. For the research, 60 articles, theses, reports that have the keyword related to interior landscape and marketing strategy in commercial space were used as references. From the references, 70 cases were selected and analyzed to find landscape application patterns. Also, 4 store cases that landscape application have been the key to their success were selected for the survey. In doing this, I presented the readers with the packaging technique which improves brand image, the effect of stage direction which helps sensitive communication with users, the application as interior structure and the effect of an object that is useful to aesthetic effect in the commercial space. Finally, I endeavored to provide possible problems to be produced when applying the natural element in the commercial space and matters to be attended to in the management.

Development and Application of a Water Quality Model to Assess Water Purification Techniques for Lakes and Reservoirs (호소수질정화공법의 평가를 위한 수질모형의 개발 및 적용)

  • 박병흔;권순국;장정렬
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.6
    • /
    • pp.174-186
    • /
    • 2001
  • Excessive outflow of pollutant loads resulting from rapid industrialization has unbalanced the water ecosystem, deteriorating the water quality environment severely. Therefore, measures for improving the water quality are necessary to maintain clean reservoir water and restore water-friendly spaces. A water quality model which is capable of simulating daily reservoir water quality was developed. The model had been applied to Masan reservoir and Wanggung reservoir in Korea. The model appeared to be satisfactory in representing the trend of water quality variations by comparing measured and simulated results. The model had been also applied to assess water purification techniques such as dredged pool, floating island and vegetation purification system. The model was considered to assess the effect of water purification techniques on reservoir water quality improvement. The results of water quality simulation for lake water purification techniques showed that a large facility would be needed to meet the targeted water quality of the reservoir when only one technique is applied. To effectively improve the quality of the polluted reservoir water, it is therefore recommended that pollutant sources should first be controlled, and a combination of the water purification techniques applied to make the utmost use of their secondary effects such as conservation of the reservoir volume capacity, establishment of a recreation space, promotion of bio-diversity, and improvement of the lake landscape.

  • PDF

A Study on Hygienic Space Planing of a University Student Restaurant - Focused on the customer space in E University Student Restaurant in Seoul Applying HACCP - (대학 학생 식당의 위생적 공간 계획에 관한 연구 - 서울 E 대학 학생 식당 고객 공간에 HACCP 적용 중심으로 -)

  • Lee, Jong-Ran
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.182-189
    • /
    • 2011
  • This research suggests a way of hygienic space planing of the customer space in the university student restaurant of E University in Seoul. For this study. the behavior observation in the restaurant was conducted in order to analyze the sequence of customer behavior related space planing applying HACCP (Hazard Analysis And Critical Control Point). Also the survey was conducted to analyze opinions of customers about hygiene of the space. The results of the analyses of the observation and the survey were similar in terms of hygiene. In conclusion, for hygienic space planing of the customer space in restaurant, the space circulation should be planned according to the hygienic sequence of customer behavior. The spaces in restaurant should be divided into two areas: the clean area and the contaminated area to prevent cross-contamination. The clean area, such as spaces preparing dishes and food including water and table hall where customers eat, should be separated from the contaminated area such as the spaces where waste is handled and where dirty dishes are kept. In order to prevent cross-contamination, hygiene facility to remove contamination should be located before going to the clean area. More specifically, the hygiene facility should be located between a cash counter and a space preparing dishes so that customers can wash their hands before they touch dishes. Space arrangement with feed-back process to check the possible points of cross-contamination and correct space arrangement until the possibility of cross-contamination is removed in the restaurant.

A Case Study on the Maintenance Activities of the Naturally Favorable Water Space Through the Participation of Residents - A case of Japanese rural areas - (주민참여에 의한 농촌지역 친수공간 유지관리활동 사례분석 - 일본 농촌지역을 사례로 -)

  • Yang, Yong-Seok;Kim, Sun-Joo;Senga, Yutaro
    • Journal of Korean Society of Rural Planning
    • /
    • v.12 no.1 s.30
    • /
    • pp.11-21
    • /
    • 2006
  • The purpose of this study is to verify the result of the previous studies and to clarify the types and activation factors of maintenance activities of the naturally favorable water space through the participation of residents in rural areas, through a further survey of the area proposed as a program in the existing study review and previous study related to the participation of residents. The survey was conducted through the survey of 1,242 households and 1,335 persons intended for Japanese rural areas. The study result is summarized as follows. The types of the maintenance activities in the areas intended for the survey have been classified into 'rural type' and 'combination type' through the analysis results by the references like the comparison analysis, job percentage and main utilization purpose of facilities for each type of maintenance and operation activities. In case of the 'rural type' area, residents were doing maintenance activities centered on the group activities rather than personal maintenance activities. Also, the activities of maintenance & operation group members were more active than non-members, and the water-friendly utilization to the facilities was not directly affecting the maintenance activities of residents. In case of the 'combinational type' area, there was no common characteristic according to each area, and the participation percentage in the maintenance activities was low compared with the 'rural type' area. According to the analysis result based on the participation degree of personal maintenance activities, the repair of facilities as a naturally favorable water space, implementation of projects reflecting the opinions of residents, educational programs conducted in order to motivate the participation of residents, etc. have been analyzed as the factors affecting the activation of maintenance activities of residents. Through the above results, for continuous maintenance activities to be made with residents as a main body in the future, it is necessary to support maintenance groups on an administrative level and procure experts for the production and operation of programs that can increase the participation percentage of residents.