• Title/Summary/Keyword: Water sources

Search Result 2,220, Processing Time 0.026 seconds

Sustainable Management of Irrigation Water Withdrawal in Major River Basins by Implementing the Irrigation Module of Community Land Model

  • Manas Ranjan Panda;Yeonjoo Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.185-185
    • /
    • 2023
  • Agricultural water demand is considered as the major sector of water withdrawal due to irrigation. The majority part of the global agricultural field depends on various irrigation techniques. Therefore, a timely and sufficient supply of water is the most important requirement for agriculture. Irrigation is implemented in different ways in various land surface models, it can be modeled empirically based on observed irrigation rates or by calculating water supply and demand. Certain models can also calculate the irrigation demand as per the soil water deficit. In these implementations, irrigation is typically applied uniformly over the irrigated land regardless of crop types or irrigation techniques. Whereas, the latest version of Community Land Model (CLM) in the Community Terrestrial Systems Model (CTSM) uses a global distribution map of irrigation with 64 crop functional types (CFTs) to simulate the irrigation water demand. It can estimate irrigation water withdrawal from different sources and the amount or the areas irrigated with different irrigation techniques. Hence, we set up the model for the simulation period of 16 years from 2000 to 2015 to analyze the global irrigation demand at a spatial resolution of 1.9° × 2.5°. The simulated irrigation water demand is evaluated with the available observation data from FAO AQUASTAT database at the country scale. With the evaluated model, this study aims to suggest new sustainable scenarios for the ratios of irrigation water withdrawal, high depending on the withdrawal sources e.g. surface water and groundwater. With such scenarios, the CFT maps are considered as the determining factor for selecting the areas where the crop pattern can be altered for a sustainable irrigation water management depending on the available withdrawal sources. Overall, our study demonstrate that the scenarios for the future sustainable water resources management in terms of irrigation water withdrawal from the both the surface water and groundwater sources may overcome the excessive stress on exploiting the groundwater in major river basins globally.

  • PDF

A Study on Water Quality and Amount of Flowing at Nonpoint Source of Nairin Stream (내린천수계 비점오염원 오염물질 유출량조사)

  • Huh, In-Ryang;Park, Sung-Bin;Oh, Heung-Seok;Kim, Yeong-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.220-225
    • /
    • 2009
  • This study evaluates the water quality of the river near the alpine farmland in the upper Naerin stream, which is a typical stream of the upper Bukhan River with muddy water generation, by the flow examination, it aims to estimate the characteristics of nonpoint sources flowing out from the investigated area and figure out effective methods to reduce them. According to the result of water quality examination, the average BOD of the area not affected by the cultivated land among the areas of the upper Naerin River was 0.47mg/l, and total phosphorous was 0.007mg/l; thus, it maintained the cleanliness level of Ia. The average BOD of the area with the alpine farmland was 0.52mg/l, which was similar to the one of the non-cultivated land. But total phosphorous concentration was 0.023mg/l, which was more than three times higher than the area belonging to level II due to the effect of fertilizer ingredients discharged from the cultivated land. About the loadings of the investigated area generated from each of the pollution sources, BOD was 878.5kg/day and total phosphorous was 79.7kg/day. Moreover, for the load density, BOD was $2.22kg/day.km^2$ and total phosphorous was shown as $0.20kg/day.km^2$. Regarding the rates generated from nonpoint sources like land among the loadings per pollution sources, BOD was 54%, total nitrogen was 91%, and total phosphorous was 73.4%. Therefore, it was shown that most of the nutrients were produced from the nonpoint sources. The level of BOD runoff loading in the Jaun River area, where nonpoint sources were mainly generated, was 37.1kg/day and total phosphorous was 1.33kg/day. The flow rates to the generated amount were estimated as 10.5% and 4.7% each.

Database and User Interface for Pollutant Source and Load Management of Yeungsan Estuarine Lake Watershed Using GIS (GIS를 활용한 영산호 수계 오염원 데이터베이스 구축과 오염원관리 사용자 인터페이스)

  • 양홍모
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.6
    • /
    • pp.114-126
    • /
    • 2001
  • The purpose of this study is to establish the databases of pollutant sources and water quality measurement data by utilizing GIS, and making the user interface for the management of pollutant sources. Yeongsan Estuarine Lake was formed of a huge levee of 4.35 km constructed by an agricultural reclamation project. Water quality of the reservoir has been degraded gradually, which mainly attributes to increase of point and non-point source pollutant loads from the lake's watershed of 33,374.3 $\textrm{km}^2$ into it. Application of GIS to establishment of the database was researched of pint source such as domestic sewage, industrial wastewater, farm wastes, and fishery wastes, and non-pont source such as residence, rice and upland field, and forest runoffs of the watershed of the lake. NT Acr/Info and ArcView were mainly utilized for the database formation. Land use of the watershed using LANDSAT image data was analyzed for non-point source pollutant load estimation. Pollutant loads from the watershed into the reservoir were calculated using the GIS database and BOD, TN, TP load units of point and non-point sources. Total BOD, TN, TP loads into it reached approximately to 141, 715, 2,094 and 4,743 kg/day respectively. The loads can be used as input parameters for water quality predicting model of it. A user-friendly interface program was developed using Dialog Designer and Avenue Script of AcrView, which can perform spatial analysis of point and non-point sources, calculate pollutant inputs from the sources, update attribute data of them, delete and add point sources, identify locations and volumes of water treatment facilities, and examine water quality data of water sampling points.

  • PDF

A Study on the Performance Evaluation of Combined Heat Pump System according to the Ratio of Ground Heat Source and Water Heat Source (지열원 및 수열원 비율에 따른 복합열원 히트펌프시스템 성능 평가 연구)

  • Park, Sihun;Ko, Yujin;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.2
    • /
    • pp.11-19
    • /
    • 2021
  • In this study, combined heat source heat pump system was implemented with 4 single heat source heat pumps each applied with a geothermal source and a water source. Five cases (Case1~Case5) were configured to conduct a performance comparison and analysis of the combined heat source heat pump system. First of all, as a result of analyzing the heat source, the case when 4 ground heat sources were applied (Case1) showed a uniform EST(Entering Source Temperature) distribution throughout the year since it is less affected by outside air compared to the case when 4 water heat sources were applied (Case5). In both winter and summer, the ground heat source maintained higher EST than the water heat source. Therefore, the system with high ratio of geothermal sources is advantageous for heating, and with high ratio of water heat sources is advantageous for cooling.

Characteristics of Pollutant Loads according to Types of Sources for the Chungju Dam Watershed (충주댐 유역의 오염원에 따른 오염부하량 발생 특성)

  • Kim, Chul-Gyum;Kim, Nam-Won
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.465-472
    • /
    • 2008
  • Soil and Water Assessment Tool (SWAT) model was selected as a tool for assessing the effect of pollutant sources on the total loads from the Chungju Dam upstream watershed. The model was constructed through calibration of parameters related to nitrogen (N) and phosphorus (P), which was based on the runoff and sediment modeling performed in the previous research. Using this, the spatial and temporal pollutant loadings by source type were investigated. Results of this study indicated that in most forested upstream sub-watersheds, pollutant loadings from point sources were very low, and total loadings by point and non-point sources were also insignificant. On the other hand, in #14 sub-watershed including Jecheon city, the loadings by point source were relatively considerable. For the whole watershed, non-point sources accounted for 99% of sediment, 97% of N, and 93% of P loads. And monthly non-point source loadings were concentrated on rainy summer season, while point source loadings of N and P kept nearly constant throughout the year and were high on dry winter season relative to non-point source.

Evaluation of Pollution Level Attributed to Nonpoint Sources in Nakdonggang Basin, Korea (낙동강수계 권역별 비점오염원 오염도 평가)

  • Lee, Jaewoon;Kwon, Heongak;Choi, Hanyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.393-405
    • /
    • 2014
  • In this study, the nonpoint sources were evaluated by calculating the Nadonggang basin regional water quality and nonpoint source pollution load discharged. And were selected the banks of first administration based on the results and the direction of the next administration. As a results of estimating the water quality about BOD concentration in the mid influence area in the Nakdonggang basin, it was founded that 10 sites for 'Ia' water quality level, 6 sites for 'lb' water quality level, 5 sites for 'II' water quality level, 1 sites for 'I' water quality level. The estimation of COD concentration in the mid influence area, It showed that 9 sites for 'Ib' water quality level, 6 sites for 'II' water quality level, 6 sites for 'III' water quality level, 1 site for 'IV' water quality level. The assessment of water quality made Mid influence area of Gumhogang, Nakdong Goryung, Nakdong Milyang and Namgang selected as the mid influence area of high pollution. And delivery loads of nonpoint sources were calculated for mid influence area in Nakdonggang basin(max delivery load : 17,706.7 kg/day for Gumhogang influence area). As the result of calculating NPS(nonpoint sources) delivery load and water quality at influence area in Nakdonggang basin, Gumhogang influence area was selected as an area for management priority among nonpoint sources.

Development of Optimal Network Model for Conjunctive Operation of Water Supply System with Multiple Sources (다수원 상수도시스템 연계운영을 위한 최적 네트워크 모형 구축)

  • Ryu, Tae-Sang;Ha, Sung-Ryong;Cheong, Tae-Sung
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.12
    • /
    • pp.1001-1013
    • /
    • 2011
  • Development of an optimal water supply system considering water quantity, quality, and economical efficiency is needed to decide optimal available area by combine water supply systems in overlapped area where are more than 2 water sources. The EPAnet and the KModSim were coupled to develop optimal network model. The developed network model was calibrated by measured data from water supply system in Geoje City, Korea in 2007 which have three water sources such as Sadeong booster pumping station, Guchun dam reservoir and Yoncho dam reservoir. The optimum network model was validated by operating results of 2011 to assess the economically optimized service area and optimal pump combination under the given hydraulic operating rules developed in this study. The developed model can be applied into designing water supply systems and operating rules for the conjunctive operation since the model can give the optimal solution satisfied with water quantity, economical efficiency and quality.

Research on How to Set 3rd Phase Target Water Quality on the Boundary between Metropolitan Cities/Dos Specified in Nakdong River Basin (낙동강수계 3단계 광역시·도 경계지점 목표수질 설정 방법 연구)

  • Hwang, Ha Sun;Park, Ji Hyung;Kim, Yong Seok;Rhew, Doug Hee;Choi, Yu Jin;Lee, Sung Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.70-77
    • /
    • 2017
  • Total Pollution Load Control (TPLC) is a system for managing the discharge load assigned by satisfying the Target Water Quality (TWQ) in Standard Flow Conditions (SFC). TWQ for a between Metropolitan Cities/Dos Specified (Cites/Dos TWQ) is very important to be the basis of each Unit Watershed TWQ. The purpose of this study was to establish a rational and scientific 'Calculation Metohd of Cites/Dos TWQ'. A methodology for the 3rd phase 'Cites/Dos TWQ' was proposed in this study based on review of the past phase (1rd and 2rd) 'Cites/Dos TWQ' in nakdong river. And utilized water quality model to estimate 3rd phase 'Cites/Dos TWQ' The allocation method of individual discharge sources are important for estimating 'Cites/Dos TWQ' In this case, the key point of the method of calculating the total allowable individual sources is the balance of the equity and the efficiency between individual sources of reduced pollutants. Thus, water quality shall be determined with regard to the current emission levels, the reduction capacity and the technical possibilities of individual sources. We estimate 3rd phase 'Cites/Dos TWQ' according to the 'Calculation Method of Cites/Dos TWQ'.

Detection of Noise Sources in a Cavitation Tunnel by using Beam-Forming Method (빔형성 기법을 이용한 공동수조 내부의 소음원 탐지)

  • 이정학;서종수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.749-754
    • /
    • 2003
  • In this paper, we introduce the measurement of the underwater noise with 32channel hydrophone array of Samsung CAvitation Tunnel (SCAT) and the detection technique of noise sources by using the beam-forming method. Measurement and way signal Processing under fluid flow are essential works for the underwater acoustics, especially for the detection of noise sources. As the acoustic impedance of the water is relatively high and the tunnel is an enclosed system, we have to consider the interaction between tunnel and water together with the reflection of noise in the beam-forming technique. Also, for a hydrophone array system that is fixed on one side of tunnel wall as done in SCAT is liable to suffer from some limitations in the detection of the noise sources with the array, we discuss these limitations particularly on the frequency range and spacing of noise sources.

  • PDF

Isolation of Environmental Mycobacteria from Diverse Water Samples Using Cetylpyridinium Chloride

  • Choi, Yeon-Im;Jin, Hyun-Woo;Lee, Gyu-Sang;Kim, Jong-Bae;Song, In-Kenn;Kim, Young-Joon;Lee, Hye-Young
    • Biomedical Science Letters
    • /
    • v.16 no.3
    • /
    • pp.133-138
    • /
    • 2010
  • Despite of the increasing importance of environmental mycobacteria, detection and identification of mycobacteria from environmental sources including water have been fraught with technical difficulties. Although, several protocols to optiruize isolation of mycobacteria from water sources have been reported, standard method has not yet been established. In this study, usefulness of cetylpyridinium chloride (CPC), a cationic quaternary ammonium compound, for the isolation of environmental mycobacteria from diverse water samples was evaluated. For this, water samples from diverse water sources such as effluent water, lake water, and underground water were collected, treated with diverse concentrations of CPC, and plated on the solid agar plates. Subsequently individual colonies grown on the plates were sequence analyzed for identification of each colony. In brief, the results from this study showed that the growth of mycobacteria was enhanced by use of CPC as a pre-treatment reagent to water samples by inhibiting growth of other non-mycobacteria in water. In fact, the effect of CPC to decontaminate non-mycobacteria for isolation of mycobacteria was better than 1~4% of NaOH, which is a routinely used decontaminating reagent widely employed for culturing mycobactera from sputum specimens. Therefore, the results from this study seems to support that the CPC pre-treatment may be useful for isolation of mycobacteria from diverse sources including clinical specimens which are often contaminated with other bacteria.