• Title/Summary/Keyword: Water quality measuring system

Search Result 74, Processing Time 0.024 seconds

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

A Study on the Design of Water Pollution Alarm System using Solar Cell (솔라셀을 적용한 수질오염 경보 시스템의 설계에 관한 연구)

  • Yoon, Seok-Am;Choi, Jang-Gyun;Yoon, Hyung-Sang;Kim, Min;Lee, Gi-Je;Cha, In-Su
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.569-572
    • /
    • 1999
  • As the industry has been growing rapidly, the problem of environmental pollution has been on the rise seriously. In this paper, we used solar cells at the power supply unit of the equipment, which has been sold at present, for measuring the quality of water in order to complement the problem. Also, to get rid of the inconvenience that the examiners must go to the job site, check and collect the polluted water we set the goal at designing the water pollution alarm system which measures the quality of water automatically using one-chip microprocessor and materializing the program.

  • PDF

Implementation of an Automated In-line Water Quality Measurement System of Recirculation Fish Farm with IoT (IoT에 의한 순환여과식 양식장 자동 수질 측정 시스템 구현)

  • Kim, Sun-Woo;Choi, Yeon-Sung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.3
    • /
    • pp.477-484
    • /
    • 2017
  • In the conventional recirculation fish farms, there is a lot of difficulties due to lack of professional manpower and high reliance on imported measurement equipment. In this paper, we implement an automatic water quality measurement system which can measure the pollution degree in a water tank of fish farms using an optical sensor(pH, DO) with the IoT technology. The problem with existing systems is that the fish tank should be checked by means of human, or put the measuring equipment into the water tank of fish farms and measurement directly. But, it has a bad influence on the growth of fish. In this paper, we propose a method of indirect measurement without immersing the measurement equipment in a water tank of fish farm and develop a sustainable measurement system in an environment containing salt and lots of pollutants without affecting the growth of fish within the water tank of fish farms.

The Role of Charge and Retention in Effective Wet end Management

  • Rantala, T.;Nokelainen J.;Ojala, T;Dr. Taina Sopenlehto
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.1-10
    • /
    • 2000
  • The development of paper machines, increasing machine speeds with new, mostly low basis weight and/or high ash content paper grades, as well as the fact that several trends regarding process items have increased the sensitivity of papermaking. At the same time, papermakers are looking for flexibility in the production line. We can say that with all PMs the biggest benefits with the lowest capital spending can be achieved by focusing on improved wet end management. In order to manage wet end chemistry on a paper machine, our goal is to control sub-process through which we can influence the operation of the entire wet end with maximum effect. Key measurements and controls are-white water consistency control which is the most effective way to control retention - charge demand measurement and control which takes care of concentration of the anionic material entering to PM -ash measurements and controls which are deeply related to retention and paper quality This paper presents and concentrates to two of these key controls ; retention and charge. The purpose of charge control is to give the process control the tools to react to changes caused by amount of dissolved and colloida material incoming to wet end system. It is called coagulation or fixing control. Retention control is then taking care of retention aid flow to the process by responding any changes seen in white water consistency. It is called flocculation control. Each of these solutions separately , and even more effectively all together, stabilize the wet end operations and so greatly improve the produced paper quality and machine runnability. Practical results will be presented and they are referring to the latest mill cases. We have developed the first wet end measuring system in the late 1980s and control solutions based on this modern measuring technology were completely updated in 1990s. This paper introduces the principle, operation , and results of our unique wet end analyzers (retention and charge ) which are at the level of automation solutions as a part of paper machine quality control Especially our newest member of the platform , on-line charge analyzer has reached and set new standards to the on-line charge monitoring.

The Role of Charge and Retention in Effective Wet End Management

  • Rantala, T.;Nokelainen, J.;Ojala, T.;Sopenlehto, Taina
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.44-53
    • /
    • 2000
  • The development of paper machines, increasing machine speeds with new, mostly low basis weight and/or high ash content paper grades, as well as the fact that several trends regarding process items have increased the sensitivity of papermaking. At the same time, papermakers are looking for flexibility in the production line. We can say that with all PMs, the biggest benefits with the lowest capital spending can be achieved by focusing on improved wet end management. In order to manage wet end chemistry on a paper machine, our goal is to control subprocesses through which we can influence the operation of the entire wet end with maximum effect. Key measurements and controls are - white water consistency control which is the most effective way to control retention. - charge demand measurement and control which takes care of concentration of the anionic material entering to PM. - ash measurements and controls which are deeply related to retention and paper quality. This paper presents and concentrates to two of these key controls: retention and charge. The purpose of charge control is to give the process control the tools to react to changes caused by amount of dissolved and colloidal material incoming to wet end system. It is called coagulation or fixing control. Retention control is then taking care of retention aid flow to the process by responding any changes seen in white water consistency. It is called flocculation control. Each of these solutions separately, and even more effectively all together, stabilize the wet end operations and so greatly improve the produced paper quality and machine runnability. Practical results will be presented and they are referring to the latest mill cases. We have developed the first wet end measuring system in the late 1980s and control solutions based on this modern measuring technology were completely updated in 1990s. This paper introduces the principle, operation, and results of our unique wet end analyzers (retention and charge) which are at the level of automation solutions as a part of paper machine quality control. Especially our newest member of the platform, on-line charge analyzer has reached and set new standards to the on-line charge monitoring.

  • PDF

A Study on Robot System Development for Environmental monitoring of Reservoirs (저수지 환경 감시를 위한 로봇 시스템 개발을 위한 연구)

  • Shin, Jin-Seob;Lee, Jeong-Ihll
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.163-168
    • /
    • 2016
  • For the quality increase of agricultural and aquatic products, it is necessary to the efficient management system of integrated control and accurate data for improving the water quality of reservoirs. This may be using the USN save time and money. In this paper, the water surface robot was designed and manufactured for measuring and announcing the environment informations, and it's network was constructed. The robot had more excellent durability and was more inexpensive than previous model. The network was designed considering connection with ZigBee, TRS, Wi-Fi or LTE network. Also the exploration function of the robot was confirmed by the simulation and the user interface was programmed.

Development of Experimental Device for Analysis of Hydraulic Oil Characteristics with Dielectric Constant Sensors (유전상수 센서를 이용한 유압 작동유의 분석을 위한 실험장비 개발)

  • Hong, Sung-Ho
    • Tribology and Lubricants
    • /
    • v.37 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • An experimental device was developed for analysis of hydraulic oil characteristics with dielectric constant sensors. Online analysis is the most effective method of the three methods used for analyzing lubricant oils. This is because it can monitor the machine condition effectively using oil sensors in real time without requiring excellent analysis skill and eliminates human errors. Determining the oil quality usually requires complex laboratory equipment for measuring factors such as density, viscosity, base number, acid number, water content, additive, and wear debris. However, the electric constant is another indicator of oil quality that can be measured on-site. The electric constant is the ratio of the capacitance of a capacitor using that material as a dielectric, compared with a similar capacitor that has a vacuum as its dielectric. The electric constant affects the factors such as the base oil, additive, temperature, electric field frequency, water content, and contaminants. In this study, the tendency of the electric constant is investigated with a variation of temperature, water content, and dust weight. The experimental device can control working temperature and mix the contaminants with oil. A machine condition monitoring program developed to analyze hydraulic oil is described. This program provides graph and digital values with variation of time. Moreover, it includes an alarm system for when the oil condition is bad.

A Study on Interferences of Monochloramine in the Measurement of Ammonia by Phenate Method (Phenate 법으로 암모니아 분석시 염화아민의 방해 작용에 관한 연구)

  • Yoon, Je-Yong;Lee, Sang-Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.1
    • /
    • pp.45-51
    • /
    • 1998
  • The determinations of ammonia in water for drinking purpose served as one basis of judging the sanitary quality of water for a great many years. However, presently ammonia regulation varies depending on countries. In USA and Canada, ammonia is added to water for chloramination process. However, for korea, there is ammonia regulation of treated water in Korea which should not exceed 0.5mg/l as $NH_3-N$. There was a report exceeding 0.5mg/l of ammonia in chlorinated water when the famous drinking water contamination episode happened in the downstream of Nadong River, 1994. With lack of sewer distribution system and treatment plants of domestic wastes, many water treatment plants have a difficulty of complying with ammonia regulation in treated water. Breakpoint chlorination is usually performed to get rid of ammonia. The method which is allowed to measure ammonia in Korea is Phenate method. However, it would be undesirable to use Phenate method for measuring ammonia in chlorinated water if Phenate method would not differentiate ammonia from chloramine. A good possibility of interferences in measurement of ammonia exists because Phenate method include the step of the formation of chlorine and would not differentiate chloramine which is formed as a result of reaction between chlorine and ammonia. This study was on inaccuracy of Phenate method for measuring ammonia of chlorinated water when chloramine and ammonia coexist. This study found that Phenate method measured all chlormaine as ammonia. Ammonia measurement by ion chromatography confirmed this results. Finally, the result from this study suggests that ammonia measurement by Phenate method in chlorinated water should be revised accordingly.

  • PDF

Development of CMOS Image Monitoring System for Measurement of Biosensor Activity using Genetic Algorithm (유전자 알고리즘을 이용한 바이오센서 활동량 측정 CMOS 이미지 센서 모니터링 시스템 개발)

  • Park, Se-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.5
    • /
    • pp.930-936
    • /
    • 2008
  • CMOS image monitoring system for optimal measuring the activity of biosensor is developed using genetic algorithm. Most of living organism in water as water flea, fish, etc are frequently used as biological sensor for monitoring the water quality. It is very difficult to measure the activity of biosensor by image sensor because the value of measurement is varied with gathering method of biosensor images. The suggested monitoring system can optimally measures the activity of biosensor by genetic algorithm. The system is implemented with FPGA into the small hardware which is excellent in terms of the price and performance.

Analysis of Applicability by Filter Technique for Water Level Correction of Agricultural Canal (농업용 수로부의 수위 보정을 위한 필터기법별 적용성 분석)

  • Joo, Donghyuk;Na, Ra;Kim, Ha-Young;Choi, Gyu-hoon;Yun, Hyung Chang;Park, Sang-Bin;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.5
    • /
    • pp.51-68
    • /
    • 2023
  • Due to the recent integrated water management policy, it is important to identify a reliable supply amount for establishing an agricultural water supply plan. In order to identify the amount of agricultural water supply, it is essential to calculate the discharge by measuring the water level and flow velocity of reservoirs and canal agricultural water, and quality control to ensure reliability must be preceded. Unlike agricultural reservoirs, canal agricultural water are more sensitive to the surrounding environment and reservoir irrigation methods (continuous, intermittent irrigation, etc.), making it difficult to estimate general water level patterns and at the same time a lot of erroneous data. The Korea Rural Community Corporation is applying a filter technique as a quality control method capable of processing large quantities and real-time processing of canal agricultural water level data, and applicability evaluation is needed. In this study, the types of errors generated by the automatic water level measurement system were first determined. In addition, by using the manual quality control data, a technique with high applicability is derived by comparing and analyzing data calibrated with Gaussian, Savitzky-Golay, Hampel, and Median filter techniques, RMSE, and NSE, and the optimal parameters of the technique range was derived. As a result, the applicability of the Median filter was evaluated the highest, and the optimal parameters were derived in the range of 120min to 240min. Through the results of this study, it is judged that it can be used for quantitative evaluation to establish an agricultural water supply plan.