• Title/Summary/Keyword: Water quality criteria

Search Result 424, Processing Time 0.028 seconds

Application of Subsurface Flow Wetland using the Phragmites australis for Water Quality Improvement of the Agricultural Reservoi (농업용 저수지 수질개선을 위한 지하흐름 갈대 인공습지의 적용)

  • Nam, Gui Sook;Pae, Yo Sop;Kim, Hyung Joong;Lee, Sang Joon;Lee, Gwang Sik
    • Journal of Wetlands Research
    • /
    • v.6 no.4
    • /
    • pp.59-69
    • /
    • 2004
  • Constructed wetlands are regarded as an important water treatment system for agricultural water quality improvement and management. The purpose of this study is to evaluate the application of subsurface flow wetland(SFW), using the Pharagmites australis as macrophytes, and to clarify the basic and essential factors to be considered in the construction and management of constructed wetlands. This study was carried out relatively short hydraulic residence time(HRT), 6hr ~ 72hr (3days), using eutrophic reservoir water with relatively low concentrations of influent and large quantity to be treated. The effluent satisfied the criteria of agricultural water quality. Removal efficiencies of Biochemical oxygen demand(BOD), Chemical oxygen demand(COD), Suspended solids(SS) and Chlorophyll a(Chl-a) were high in HRT 24hr, not any more significant increasement of removal efficiencies in HRT 48hr and 72hr. However, removal efficiencies of nitrogen and phosphorus increased as HRT increased, showing the highest efficiency at the 72hr of HRT in nitrogen, and 48hr in phosphorous. The SFW was very effective system for reservoir water quality improvement, and had the advantages of the reduction of purchasing cost to land required, lack of odors, and harmful insects, especially mosquito, the improvement of the scenic beauty and minimal risk of public exposure. Therefore, it was evaluated that the SFW was very available water treatment system for the water quality improvement of agricultural reservoir. However, it was need to consider with application of the SFW in high cost of construction and troublesome of management.

  • PDF

Applicability of UV and UV/$H_2O_2$ Processes in the Control of Pharmaceuticals and Personal Care Products and Microbiological Safety for Water Reuse (잔류 의약품류의 제거 및 미생물학적 안전성을 고려한 하수 재이용 기술로서의 UV 및 UV/$H_2O_2$ 공정의 적용성)

  • Kim, Il-Ho;Tanaka, Hiroaki
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.7
    • /
    • pp.722-729
    • /
    • 2010
  • Over the last decades, much consideration has been given to microbiological and chemical risks, especially when wastewater was reclaimed as water resources for urban water, irrigation water and recreational water etc. We investigated the performance of UV-based processes such as UV and UV/$H_2O_2$ for both the removal of pharmaceuticals and personal care products (PPCPs) as an emerging chemical and the inactivation of pathogen with bench-scale experimental study. 38 kinds of PPCPs including antibiotics and analgesics were detected from secondary effluent used as tested water. Bench-scale experimental study showed that UV process would require considerable UV dose for the effective PPCPs removal. Contrarily, PPCPs removal efficiency significantly improved by the combination of $H_2O_2$ with UV even at a lower UV dose and, moreover, their removal efficiency increased with the increased initial $H_2O_2$ concentration. Besides naproxen (>89%), concentrations of all the investigated PPCPs decreased by more than 90% of their initial concentrations under $923\;mJ/cm^3$ of UV dose and 6.2 mg/L of $H_2O_2$. Previous studies showed that this operational condition could get 4~5 log inactivation for Total coliform, indicating that UV/$H_2O_2$ process will be appropriate to comply with the criteria of California Title 22 for Total coliform.

A Study on the Planning Criteria for Thalassotherapy Facility (해양치유시설 계획기준에 관한 연구)

  • Lee, Han-Seok;Kang, Young-Hun;Seong, Hai-Min
    • Journal of Navigation and Port Research
    • /
    • v.44 no.1
    • /
    • pp.20-31
    • /
    • 2020
  • The purpose of this study was to provide planning criteria for the thalassotherapy facility. Among the various contents of the planning criteria, the crucial parts of the thalassotherapy facility planning are the location, facility environment, and room space. To do this, we first examined the characteristics of the thalassotherapy facility and inquired about the thalassotherapy resources and treatments that are the basis of the thalassotherapy facility planning. And then, the overseas qualification criteria related to thalassotherapy facility were analyzed. Based on the above research results, the criteria for the thalassotherapy facility planning on location, facility environment, and spaces of rooms are presented. The location is within 1km of the coastline, where there is no pollutant emission facility, and the climate conditions are maintained more than 80% throughout the year below 'caution' level of the thermal sensation index and sensory temperature. The water quality of the facility environment meets the stricter criteria among the domestic standards or ISO 17680 standards, and the air quality is 60% of the atmospheric environment standard of the 「Framework Act on Environmental Policy」 and SO2, NO2, O3 and PM10 concentration shall ensure that the annual number of exceeding standards meets the EU standard, and noise is less than 50dB per daytime, 40dB per night. Therapy spaces have to meet the standards of the 「Building Act」, the working standards of architectural planning and international standards according to their function and use.

Evaluation for Contents of Contaminants and Leaching Characteristics of Bottom Ash (바텀애쉬의 유해물질 함량 측정 및 용출특성 평가연구)

  • Koh, Taehoon;Lee, Sungjin;Shin, Minho;Kim, Byongsuk;Lee, Jeakeun;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we tried to determine any detrimental effects on water quality when bottom ash obtained from a coal-fired power plant intended to be used as a fill material in construction sites. Physical-chemical properties of bottom ash were determined using proximate analysis, elemental analysis, XRD, and XRF. Classification of bottom ash as a waste material and soil contamination due to the use of bottom ash were performed by Korea waste standard leaching test and soil toxicity test, respectively. Results of leaching tests were compared to the regulations for water quality and groundwater quality and no harmful effects on water quality were found. Most of heavy metals in leachate were below detection limits but trace amount of $Cr^{6+}$ was found. However, concentration of $Cr^{6+}$ was below the regulation criteria. Column leaching tests indicated that concentrations of Pb and Zn were slightly higher than regulations but below regulations within 1 PVE, but concentrations of sulfate were 10 times higher than regulation and thus, the required time to reach regulation was almost 8 PVE.

Bacteriological Quality of Sea Water in Deukryang Bay, Korea (득량만 해수의 세균학적 수질)

  • CHANG Dong-Suck;JEONG Eun-Tak;YU Hong-Sik;LEE Eun-Woo;LIM Sung-Mee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.1
    • /
    • pp.77-81
    • /
    • 1998
  • A bacteriological study of sea water in Deukryang Bay was conducted to evaluate sanitary conditions of the bay and compliance of waters with the recommended bacteriological criteria for the designated area of shellfish cultivation. Sea water samples were collected at the established sampling stations (fig. 1) from May 1995 to November 1996. During the study period, coliform group, fecal coliform, classification of coliform group with IMViC reactions and pathogenic vibrios were analyzed. Coliform group and feral coliform MPN's were ranged from $<\;3.0\~4600/100m{\ell}\;and\;<\;30\~1,100/100m{\ell}$, respectively. The bacteriological criteria of sea water in shellfish growing area should be less than 70 per l00ml of sea water for median value of coliform MPN, and below $10\%$ of the samples which contain over than 230 for coliform MPN or over than 43 for fecal coliform MPN, Most of the waters from 26 sampling stations were complied water coliform criteria recommended for designated shellfish growing area. Then, the ratios of the samples with move than 230/10ml of coliform group MPN and more than 43/100ml of fecal coliform MPN were $7.4\%$ and $8.5\%$, respectively. The bacterial density of the sea water was deeply affected by rainfall amount. For example, coliform bacterial counts of sea watery after 48 hours from 93 mm rainfall were $6\~7$ times higher than those of without rainfall. During the study period, infectious bacteria such as Vibrio cholerae, Salmonella sp. an d Shigella sp. were not detected from the samples, but detection ratios of Vibrio parahaemolyticus and Vibrio vulnificus were $15\~20\%$ in summer months.

  • PDF

Evaluation of Bacteriological Safety for the Shellfish growing Sea waters in Seocheon Area, Korea (충남 서천 패류생산해역에서의 세균학적 위생안전성 평가)

  • Byun, Han-Seok;Song, Ki-Cheol;Lee, Doo-Seog;Shim, Kil-Bo;Lim, Chi-Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • A Sanitary survey in an Important shellfish-growing area of Biin Bay in Seocheon-gun Korea, was conducted to evaluate bay conditions and compliance with the bacteriological criteria for areas designated for the production of shellfish for export. Seawater samples were collected monthly at 55 sampling stations established in the survey area from January 2006 to December 2008. Bacteriological water quality did not change in response to a small rainfall (10.0 mm), but it increased abruptly in response to rainfall to 62.5 mm The most probable number (MPN) value for total coliforms and fecal coliforms in 1, 980 seawater samples ranged from <1.8 to >1, 600 MPN/100mL and from <1.8 to 330 MPN/100mL, respectively. The geometric mean and estimated $90^{th}$ percentile value for total coliforms ranged from 2.0 to 10.3 MPN/100mL and from 7.0 to 42.6 MPN/100mL respectively. The geometric mean and estimated percentile value for fecal coliforms ranged from 1.8 to 4.0 MPN/100mL and from 1.9 to 18.3 MPN/100mL, respectively. Accordingly, the bacteriological water quality of Biin Bay met the National Shellfish Sanitation Program (NSSP) and Korea Shel1fish Sanitation Program(KSSP) criteria for areas designated for shellfish production for export in Korea.

A Study on the Wild and Scenic Rivers System(I) -American Experience, and Suggestions for System Building in Korea- (自然景觀水系의 體系樹立을 위한 基礎硏究(I) -美國의 自然景觀水系制度 紹介 및 國內適用 事例硏究-)

  • Ahn, Tong-Mahn;Ahn, Seong-Ro;Jin, Young-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.18 no.3 s.39
    • /
    • pp.57-70
    • /
    • 1990
  • This study is on system building and model case study to establish a new framework of "The Wild and Scenic Rivers System" and to apply this to Korean rivers. The Wild and Scenic Rivers System of the U. S. , which had become law in 1968 for establishing wild scenic and recreational river areas, was investigated. The techniques of two American case studies about the National Wild and Scenic Rivers System designation were investigated and synthesized, and study process was adjusted to Korean river system. Additionally, pilot study was carried out by the method and results were as follows : 1) In the American Wild and Scenic Rivers System, each river was evaluated based on eligibility criteria for designation, such as remarkable scenic, recreational, fish and wildlife, cultural or other ecological values. Segmented river areas were classified into three or four grades and management plans were prepared accordingly. 2) The management of rivers in Korea has emphasized on the flood control and water resources management up to the present, and now takes a growing interest in water quality. But it has been concerned very little with wild and scenic resources conservation of river corridors. It is strongly recommended to build Wild and Scenic Rivers System in Korea for rational management and conservation of the valuable natural resource. 3) Suggested evaluation criteria for the Korean Wild and Scenic Rivers System were wildness, wildlife and plants, hydrology, scenic quality, and historical and cultural resources. The river areas may be graded into four : Positive conservation area(I), Negative conservation area(II), Negative development area(III), Positive development area(IV). Management guidelines were proposed for each grade. 4) To test the applicability of the approach, one of the major tributary of the Han-River was selected for pilot study. The result showed that the evaluation and grading system worked well. Finally, it is recommended to incorporate the Wild and Scenic Rivers System into Korean national park system, and to amend the Korean National Park Act to enable this.

  • PDF

Estimation of Rock Erodibility due to Energy Dissipation of Inflow Passing through the Sluice Gate of Seadike (배수갑문 유입수류의 에너지 감쇠에 따른 암석 침식 가능성 추정)

  • Jo, Jin-Hun;Park, Yeong-Jin;Park, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.2
    • /
    • pp.237-245
    • /
    • 2000
  • Sihwa seadike is originally designed to control the water level In lake Sihwa. However the sluice gate is being operated everyday to preserve the water quality of lake. Due to the frequent operation of gates the bottom of drainage canal which is composed of weathered rock and soft rock is being scoured. Recently the bottom in the front area of apron was protected by putting underwater concrete. This study is carried out to understand the hydraulic situation for protection, and to estimate the trend of scouring by comparing between energy dissipation and registance of bottom rock. Annandale(1995) introduced the erodibility index theory, and suggested a criteria to judge the erodibility of rock through the relation between the erodibility index and energy dissipation. Determenation of erodibility index of rock is based on the results of sample core analysis, and the energy dissipation of flow is calculated from the estimation of total head on the scale model. These two values are plotted on the criteria, and the erodibility of rock is determined.

  • PDF

Estimation of River Instream Flow Considering Fish Habitat Conditions (어류의 서식처 조건을 고려한 하천의 필요유량 산정에 관한 연구)

  • Kang, Jeong-Hoon;Lee, Eun-Tae;Lee, Joo-Heon;Lee, Do-Hun
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.11
    • /
    • pp.915-927
    • /
    • 2004
  • The purpose of this paper is to estimate the instream flow of the South Han River Basin to ensure an adequate supply of suitable quality of water for preservation and enhancement of aquatic ecosystems. Proposed methods is Physical Habitant Simulation System of Instream Flow Incremental Methodology. Accurate estimation on a water depth and a velocity distribution was acquired by applying a two dimensional hydrodynamic model for a simulation of a hydraulic parameter necessary for the habitat evaluation to be used in a physical habitat simulation system. The Habitat Suitability Criteria with the application of univariate curve on zacco platypus as a representative fish was able to be established by conducting a field investigation. The establishment of a hydrological materialistic balance between upper and lower streams was confirmed by conducting a simulation simultaneously together with a mainstream section, which was excluded from the considered sections for the inhabitation evaluation of fish.

Financial Resources allocation criteria for Integrated River Basin Management (유역통합관리를 위한 재원분담방안 연구)

  • Kim, Chong-Won;Kim, Chang-Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.1 s.174
    • /
    • pp.63-72
    • /
    • 2007
  • The main purpose of this study is that financial resources allocation criteria are examined closely between central government and local government as well as among local government in a river basin. Financial resources allocation principles reflecting water use, flood control, and water quality improvement are reviewed and derived two categories such as common factors and individual factors. The weights of each factor are assigned by analytical hierarchy process. The results of applying four river basins (Han river, Geum river, Nakdong river, Yeongsan-seumjin river) show that rational raising of financial resources are different according to the characteristics of each river basin. Findings are as follows: In case of Han river and Yeongsan Seumjin river, benefit principle and polluter pay principle by individual factors are more attractive than other Principles. Solvency principle by common factor is more acceptable than the other principles in Nakdong-river and Geum-river.