• 제목/요약/키워드: Water pump

검색결과 1,495건 처리시간 0.03초

오수/합병정화조의 배출물 제어시스템 연구 (The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;김건호;오지영;임총규;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2001년도 추계학술대회
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

퍼지제어를 통한 오수-합병정화조의 오니 측정 및 제어시스템에 관한 연구 (The Development using Fuzzy Control of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;박윤규;강경식
    • 대한안전경영과학회지
    • /
    • 제3권4호
    • /
    • pp.53-63
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which are the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxyzen demanding amount has to control. Each room mus be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

A Hydraulic Model Stydy of the Water-Intake Structure near River Mile 37 on the Missouri River

  • Byungman-Yoon
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 1992년도 수공학연구발표회논문집
    • /
    • pp.133-141
    • /
    • 1992
  • A three water-intake structure designed to built along the right bank of the Missouri River near Chesterfield, Missouri was model-tested at an undistorted scale of 1:5. Although the discharge capacity of each of six pumps to be installed is only 21,000 gpm, the model indicated strong flow circuation and unstable free-surface conditions as flow entered the two-pump bay through a narrow sluice opening at an angle. Strong free-surface vartices were also observed in the model. The sump modifications developed in the study included an array of baffle bars, a perforated plate, floor splitters, and floor-corner fillets. The solutions developed in this study could be applied to other pump sumps with multiple pump units.

  • PDF

화력발전소 터빈 보조기기 제어 관한 고찰 (A Study on Turbine Auxiliary Devices in a Thermal Power Plant)

  • 정창기;최인규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1667-1668
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Turbine auxiliary devices such as condenser, deaerator, feed water heater, gland steam condenser, pump recirculation equipment, feed water pump, and so on should be operated well so that the steam turbine exert its maximum efficiency. There are many control loop such as hot well level and condenser recirculation, deaerator level, pegging steam pressure, feed water heater level, feed water pump recirculation. In this paper condenser level control and deaerator level control are going to be described.

  • PDF

수도시설을 이용한 지열냉난방시스템의 실증연구 (The Field Test of Heat Pump Cooling & Heating System using the water-purifying device)

  • 황기섭;정우성;안영섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.629-634
    • /
    • 2007
  • The Alternative energy has lately attracted considerable attention due to the high oil price and environment problem. In this study, field test of facility for using the geothermal energy source from water-purifying device was constructed and monitoring devices are installed to estimate the efficiency of this system. Initial installation cost can be saved efficiently by connecting a heat pump system into the existing pumping well in site of water-purifying in Cheongju. One set of monitoring results during summer was presented and analyzed.

  • PDF

SMART 원자로용 냉각재 순환펌프의 온도특성에 관한 연구 (A Study on the Temperature Characteristics of Main Coolant Pump for System-integrated Modular Advanced Reactor)

  • 구대현;방덕제;강도현;김종인;조윤현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.320-326
    • /
    • 2000
  • The canned motor of 3-phase induction is used for main coolant pump(MCP). The type of motor is canned-motor that stator and rotor are welded by sealed can. So, cooling water flows in the air gap of the canned motor as an independent cycling cooling system from the air gap to yoke of the motor to prevent high temperature of stator can and to lubricate bearing. Heat exchange is occurred between cooling water in the air gap and cooling water from the exterior pump to prevent rising of temperature in the motor. I has to analyze the characteristics of can exactly because the loss and the heat in the can are very important to design MCP. Therefore, thermal analysis is studied considering the effect of eddy-current los induced in the can.

  • PDF

열펌프를 이용한 슬러리 돈분뇨 증발건조처리시스템 개발 (Development of Heat Pump Use Slurry Pig Manure Evaporation Drying System)

  • 김현태;최홍림
    • Journal of Biosystems Engineering
    • /
    • 제30권1호
    • /
    • pp.32-37
    • /
    • 2005
  • This study was conducted the slurry pig manure treatment by condensation drying of liquid from the slurry manure with a heat-pump and electric heater combined with air flow channel system. The system was designed as liquid and solid matters separation of slurry manure, and it can doing continuous input of slurry manure from a pig house, and it can operated year round use for pig farms. The separation of liquid and solid matters from slurry manure needed the prevention of solid accumulation in the system. The system was designed as closed space from outside air space for maximized evaporation of liquid and the condensation of liquid from slurry manure. The system can be operated the pig slurry manure treatment regardless of seasons in a yew. The separated evaporation water from the pig slurry manure by the heat-pump was satisfactorily pure water that can be used as washing water in livestock farms. The system can applicate to about 100 heads of pig, and the proper area of evaporation plate system was considered around $10\;m^2$. The input electrical energy of about 15 kWh which the cost equal to 250,000 won per month.

원자력 발전소용 순환수 펌프의 성능해석 (THE PERFORMANCE ANALYSIS OF A CIRCULATING WATER PUMP FOR A NUCLEAR POWER PLANT)

  • 이명수;한병윤;황도연;유성수;박형구
    • 한국전산유체공학회지
    • /
    • 제14권3호
    • /
    • pp.69-75
    • /
    • 2009
  • The objective of this study is to investigate the suitable design for a domestic Circulating water pump(CWP), which is used in cooling-water intakes for the unit 3 and 4 of Yeonggwang nuclear power plant. All the simulations are performed, using CFD method with a commercial code STAR-CCM+ version 3.02. After modeling a present design of the pump, the flow around the rotating blade was calculated by using quasi-static method and sliding mesh method with the almost same condition as an actual state. Based on fundamental simulations with various depth of sea water, the reference pressure for the boundary condition of the present study was decided. To verify the reliability of the calculation results, the suction flow rate of the data was compared with that of the experimental data. As a result of this comparison, it is confirmed that two results are fairly consistent. For the improvement of the suction flow rate, computational analysis was done by changing a flow channel and blade shapes. It is shown that the suction flow rate of the new pump was improved.

자동차용 워터펌프의 스퀼소음 저감을 위한 영향도분석 (Parametric Study for the Squeal Noise Reduction of an Automobile Water Pump)

  • 김보형;정원영;백홍길;강동진;정진태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.492-497
    • /
    • 2013
  • In this study, a parametric study is performed to investigate the squeal noise of an automobile water pump. The squeal noise studied in this paper is generated by the self-excited torsional resonance of the rotating shaft, and this noise is related to the stick-slip phenomenon of the mechanical seal in the water pump. The mechanical seal friction has the characteristics of the negative velocity-gradient. The equations of motion of multiple-degree-of-freedom torsional vibration model is constructed by the Holzer's method and then the equation is transformed to an equivalent single-degree-of-freedom torsional resonance simulation model. A squeal noise criteria is determined by the simulation model to perform the parametric study. The design parameters(the mass moment of inertia of the pulley, the mass moment of inertia of the impeller, the length of the shafts, the radius of the shafts, spinning speed of the shafts, the position of the mechanical seal, radius of the mechanical seal, and normal load of the mechanical seal) are investigated to confirm the stability for the squeal noise.

  • PDF

하수열을 이용한 냉난방시스템에 관한 연구 (Heating and Cooling System using the Sewage Source Absorption Refrigeration and Heat Pump Cycle)

  • 이용화;신현준;윤희철;박현건
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.19-26
    • /
    • 2007
  • This paper concerns the study of absorption refrigeration and heat pump cycle to use sewage. Simulation analysis on the double-effect absorption refrigeration cycle with parallel and two-stage heat pump cycle has been performed. The working fluid is Lithium Bromide and water solution. The absorption refrigeration cycle use sewage as a cooling water for the absorber and condenser, and absorption refrigeration cycle does that as a chilled water for the evaporator of the first stage cycle. And the two-stage cycle consists of coupling double-effect with parallel and single effect cycle so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as a absorber temperature on the coefficient of performance have been studied for absorption refrigeration and heat pump cycle.