• 제목/요약/키워드: Water pressure management

검색결과 279건 처리시간 0.032초

Sequential optimization for pressure management in water distribution networks

  • Malvin S. Marlim;Doosun Kang
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.169-169
    • /
    • 2023
  • Most distributed water is not used effectively due to water loss occurring in pipe networks. These water losses are caused by leakage, typically due to high water pressure to ensure adequate water supply. High water pressure can cause the pipe to burst or develop leaks over time, particularly in an aging network. In order to reduce the amount of leakage and ensure proper water distribution, it is important to apply pressure management. Pressure management aims to maintain a steady and uniform pressure level throughout the network, which can be achieved through various operational schemes. The schemes include: (1) installing a variable speed pump (VSP), (2) introducing district metered area (DMA), and (3) operating pressure-reducing valves (PRV). Applying these approaches requires consideration of various hydraulic, economic, and environmental aspects. Due to the different functions of these approaches and related components, an all-together optimization of these schemes is a complicated task. In order to reduce the optimization complexity, this study recommends a sequential optimization method. With three network operation schemes considered (i.e., VSP, DMA, and PRV), the method explores all the possible combinations of pressure management paths. Through sequential optimization, the best pressure management path can be determined using a multiple-criteria decision analysis (MCDA) to weigh in factors of cost savings, investment, pressure uniformity, and CO2 emissions. Additionally, the contribution of each scheme to pressure management was also described in the application results.

  • PDF

도·송수관로의 실시간 운영효율화를 위한 수압계 설치위치 선정 방안 (Pressure sensor placement method for real-time operation efficiency of water transmission mains)

  • 김성한;최두용;김경필;이상철
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.491-500
    • /
    • 2016
  • Pressure monitoring is expected to be expanded in a water distribution system according to accelerated development of smart water network management technologies caused by appearances of affordable digital infrastructures like computing, storage and bandwidth. However, the placement of pressure sensors has been determined by engineer's technical decisions since there is no well-defined criteria for deciding a suitable location of pressure sensor. This study presents a placement method of pressure sensors based on the consideration of allowable error in calibrating water network analysis modeling. The proposed method is to find a minimum set of pressure sensors for achieving a reliable management of water transmissions main and increasing the efficiency of their real-time operation. In the case study in Y area's transmission main, the proposed method shows equally distributed pressure sensors in terms of hydraulics. It is expected that the proposed method can be used to manage transmission mains stably and construct a robust real-time network analysis system as a minimal criteria.

통계적 기법을 이용한 배·급수 관망 내 감압 밸브 성능 평가에 관한 사례 연구 (Evaluation of Pressure Reducing Valves performance using Statistical Approach in Water Distribution System : Case Study)

  • 박노석;최두용;이영주;윤석민
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.519-531
    • /
    • 2015
  • It has been widely accepted that the pressure management of water distribution systems using pressure reducing valves(PRVs) would be an effective method for controlling leakages. A pressure reducing valve (PRV) regulates outlet pressure regardless of fluctuating flow and varying inlet pressure, thereby reducing leakage and mitigating the stress on the water distribution system. However, the operation of a PRV is vulnerable to its mechanical condition and hydraulic operability. In this research, the effect of PRVs installed in water distribution system are evaluated in terms of hydraulic pressure reduction and mechanical performance by analyzing measured pressure data with statistical approach. A statistical approach using the moving average filter and frequency analysis based on fourier transform is presented to detect abnormally operated PRVs that have been densely installed in water distribution system. The result shows that the proposed approach can be a good performance evaluation method by simply measuring pressures for the PRVs.

상수관로 압력계 최적 위치선정을 위한 데이터기반 시험분석 (Data-based Analysis for Pressure Gauge Optimal Positioning in Water Supply Pipeline)

  • 이호현;홍성택
    • 한국정보통신학회논문지
    • /
    • 제25권6호
    • /
    • pp.834-840
    • /
    • 2021
  • 먹는 물을 생산하여 공급하는 상수도 관로에 있어서 압력계에 대한 설치와 관리 방안이 미비함에 따라 압력데이터 신뢰성의 확보 및 운영관리의 어려움을 겪고 있는 실정이다. 관망 및 펌프 등 운영관리 효율화 및 SWM(Smart Water Management)을 구현하기 위해서는 하부 계측 센서의 정확한 데이터 취득을 통하여 의사결정이 이루어져야 한다. 따라서, 본 연구에서는 게이트 밸브와 버터플라이 밸브를 중심으로 관로의 직경(D)을 기준으로 전단 -3D에서부터 후단 7D까지 압력계를 설치하여 밸브의 개도율을 조절하며 데이터를 취득하는 직관 거리 시험을 실시하였으며, 관로에 수직으로 상단(180°)부터 하단(0°)까지 45° 각도 간격으로 압력계를 설치한 후 수직 위치 시험을 실시하였으며, 이 결과들을 바탕으로 압력계의 최적 위치선정 방안을 제시하고자 한다.

GIS를 이용한 상수관망 소블록 최적설계기법 개발 (Optimal design methodology of district metered area utilizing Geographic Information System)

  • 김경필;박용균;구자용
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.223-231
    • /
    • 2015
  • District Metered Area (DMA) construction is one of the most cost effective alternatives for management of water loss (i.e., water leakage) and energy consumption (i.e., water pressure) in water distribution systems. Therefore, it's being implemented to numerous new and existing water distribution systems worldwide. However, due to the complexity of water distribution systems, especially large-scale and highly looped systems, it is still very difficult to define the optimal boundary of DMAs considering all the aspects of water distribution system management requirements. In this study, a DMA design methodology (or a DMA design model) was developed with Geographic Information Systems (GIS) and hydraulic distribution system model to determine the optimal DMA boundary.

Simulation study on porosity disturbance of ultra-large-diameter jet borehole excavation based on water jet coal wetting and softening model

  • Guo, Yan L.;Liu, Hai B.;Chen, Jian;Guo, Li W.;Li, Hao M.
    • Geomechanics and Engineering
    • /
    • 제30권2호
    • /
    • pp.153-167
    • /
    • 2022
  • This study proposes a method to analyze the distribution of coal porosity disturbances after the excavation of ultra-large-diameter water jet boreholes using a coal wetting and softening model. The high-pressure jet is regarded as a short-term high-pressure water injection process. The water injection range is the coal softening range. The time when the reference point of the borehole wall is shocked by the high-pressure water column is equivalent to the time of high-pressure water injection of the coal wall. The influence of roadway excavation with support and borehole diameter on the ultra-large-diameter jet drilling excavation is also studied. The coal core around the borehole is used to measure the gas permeability for determining the porosity disturbance distribution of the coal in the sampling plane to verify the correctness of the simulation results. Results show that the excavation borehole is beneficial to the expansion of the roadway excavation disturbance, and the expansion distance of the roadway excavation disturbance has a quadratic relationship with the borehole diameter. Wetting and softening of the coal around the borehole wall will promote the uniform distribution of the overall porosity disturbance and reduce the amplitude of disturbance fluctuations.

상수관망에서 누수탐지를 위한 역추적계산법 (Back Tracing Calculation Method for the Leakage Detection in Water Distribution System)

  • 권혁재
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.611-619
    • /
    • 2013
  • In this study, Back Tracing Calculation Method was developed to determine the leakage location and leakage amount. Previously developed determination method of monitoring location and newly developed Back Tracing Calculation Method were applied to the sample pipe network and real size pilot plant. After leakage was assumed in the pilot plant, leakage location and leakage amount could be traced by Back Tracing Calculation Method. From the results, it was found that Back Tracing Calculation Method can be applied for the leakage detection in water distribution system. Furthermore, this method can be applied for the pressure management or leakage detection as a pressure control method in water distribution system.

Development of an automated system for water-hydraulic and leakage test of pressure vessels

  • Kim, Dong-Soo;Lee, Won-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권1호
    • /
    • pp.55-59
    • /
    • 2004
  • This study developed a fully automated test system for pressure vessels, containing such as oxygen, nitrogen, which is widely used in many industries. The pressure vessel test has three major parts including weight measurement test, water-hydraulic test and leakage test followed by cleaning and drying. The control system for these tests consists of three parts: a PLC, a monitoring system and a database management system. The PLC oversees overall control of test machines, while the monitoring system measures and displays weight, pressure, flow etc. for every situations, and the database management system stores test data. These three modules are designed to communicate with one another at 1 Hz frequency alerting problematic situations to the operator. The system has gone through actual field tests for verification of performances.

터널 유지관리계측의 압력 관리기준치 설정에 관한 연구 (A study on the establishment of pressure limit values of management monitoring in tunnel)

  • 우종태
    • 한국터널지하공간학회 논문집
    • /
    • 제18권1호
    • /
    • pp.53-60
    • /
    • 2016
  • 본 논문은 터널 유지관리계측의 압력 관리기준치 설정에 대한 연구로 계측 초기에 설정된 지하철계측 초기 관리기준치를 토대로 서울지하철 6,7,9호선 8개 대표단면의 터널 콘크리트라이닝의 토압과 간극수압에 대하여 약 5년에 걸친 계측 실적을 분석하고, 국외 계측관리기준을 비교하여 향후 터널 유지관리계측에 적용할 압력 계측관리기준치 설정에 대한 연구를 수행하였다. 연구결과 향후에 터널에 적용할 유지관리계측의 압력 관리기준치는 국내적용 계측관리기준치와 국외적용 계측관리기준치 분석결과를 비교하여 안전단계는 허용압력의 60%, 주의단계는 허용압력의 80%, 정밀분석단계는 허용압력의 100%로 실무에서 쉽게 적용할 수 있는 절대치에 의한 계측관리방법을 제안하였다.

지하수위에 따른 철도사면의 안정성 변화 (The Variation of Slope Stability by Ground Water Level in Railway Lines)

  • 김현기;신민호;신지수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.789-795
    • /
    • 2008
  • Slope stability is affected by various factors. For safety management of slopes, monitoring systems have been widely constructed along railway lines. The representative data from the systems are variations of ground profile such like ground water level and pore water pressure etc. and direct displacement measured by ground clinometer and tension wire sensor. Slopes are mainly effected by rainfall and rainfall causes the decrease of factor of safety(FOS). Because FOS varies linearly by the variation of ground water level and pore pressure, it has a weak point that could not define the time and proper warning sign to secure the safety of the train. In this study, alternative of FOS such as reliability index and probability of failure is applied to slope stability analysis introducing the reliability concept. FOS, reliability index, probability of failure and velocity of probability of failure of the slopes by variation of ground water level are investigated for setting up the specification of safety management of slopes. By executing case study of a slope(ILLO-IMSUNGLI), it is showed to be applied to specification of safety management.

  • PDF